Projecta ICB1000 is a 12V power management system ideal for vehicles like Ute canopies, 4WDs, and Caravans. It features a DC/DC charger with solar and alternator inputs, switches, and sockets to manage power. The system also includes a Bluetooth-enabled LCD display to monitor auxiliary battery status and a pure sine wave inverter to run 240V appliances off-grid. With easy installation and accessible fuse holders, the Projecta ICB1000 offers a convenient and reliable power solution for various applications.

Projecta ICB1000 is a 12V power management system ideal for vehicles like Ute canopies, 4WDs, and Caravans. It features a DC/DC charger with solar and alternator inputs, switches, and sockets to manage power. The system also includes a Bluetooth-enabled LCD display to monitor auxiliary battery status and a pure sine wave inverter to run 240V appliances off-grid. With easy installation and accessible fuse holders, the Projecta ICB1000 offers a convenient and reliable power solution for various applications.

12V DC POWER
MANAGEMENT BOARD
P/No ICB1000, ICB1500, ICB2000, ICB3000
2
SYSTEM INTRODUCTION
Projecta’s range of 12V power management systems are ideal for Ute canopies, 4WD’s and Caravans. Choose
from a range of pre-built models to suit your vehicles needs. Each model includes a DC/DC charger with solar
and alternator inputs along with an array of switches and sockets to manage your power needs. The boards
also feature a convenient easy to read Bluetooth enabled LCD display to check the status of your auxiliary
battery. Lastly, it offers a powerful pure sine wave inverter to run all your 240V appliances off grid.
SYSTEM COMPONENTS
LCD Battery Monitor with Bluetooth enabled APP
500A Current Shunt
DC-DC Charger with MPPT Solar Controller
5 x 20A Switches
Dual USB Socket (total 3.1A)
2 x 50A Heavy Duty Connectors
Accessory and Merit Socket
1KW/1.5KW/2KW/3KW Inverter
Easily accessible fuse holders for each component
Low Voltage Disconnect
493mm
190mm
828mm
3
KEY FEATURES
DC-DC CHARGER (IDC25X)
Providing up to 5 stage charge simultaneously from both solar and alternator inputs, this dual battery
management system is ideal for many applications
PURE SINE WAVE INVERTER (IP1000, IP1500, IP2000 or IP3000)
Converts 12V power to 240V to allow the use of devices such as laptops and fridges on the go
BATTERY MONITOR (BM500-BT)
An intelligent and compact Bluetooth battery meter ideal for monitoring SOC% and general status. Check your
battery status via the on-board LCD display or via phone APP
SOCKETS & SWITCH PANEL
Power and charge 12V devices with 2 USB sockets (total 3.1A), a merit socket and a cigarette lighter socket. 5
switches are included to control all your connections
LOW VOLTAGE DISCONNECT (LVD50)
A robust and compact unit that protects expensive deep cycle batteries from damage caused by over-
discharge. The switch loads on the board are protected by this unit
Note: Manuals for IDC25X, BM500-BT, IP1000, IP1500, IP2000, IP3000 and LVD50 can be found on the
Projecta website: https://www.projecta.com.au
493mm
190mm
828mm
4
SAFETY WARNING
Projecta Power Boards require installation into a vehicle, canopy or trailer. If you are unsure or
not confident in 12V systems, then it recommended that a qualified auto electrician is used.
Always disconnect car batteries before working on 12V systems. Never work with a live 12V system
as this can cause injury, damage to the product or damage to the vehicle’s electrical system.
Always use appropriate PPE when using power tools.
Keep children & pets away from the Projecta Power Board.
Use suitable gauge wiring when installing . If unsure then contact a qualified auto electrician.
Do not insert any body parts or tooling in the 12V components.
Install in a cool, dry, well-ventilated area.
Ensure any exposed wires are covered.
Ensure any input wiring is sufficiently insulated and protected from abrasion.
Ensure input cables are adequately fused. Follow the instructions in this manual or contact a
qualified auto electrician for correct fuse sizing.
Figure 1
+
-
To battery positive and
negative terminals
Note: It is recommended to
install a circuit breaker or high
current fuse and fuse holder in
the positive line as close to the
battery as possible.
5
INSTALLATION INSTRUCTIONS
Step 1:
Remove Power Board from Box and dispose of packaging.
Step 2:
Remove the M5 bolts from the perimeter of the board.
Step 3:
Lift the front panel and secure the base bracket to the desired mounting location using bolts.
It is recommended to use 6 x M10 vibration resistant fasteners. See figure 2.
Wiring instructions:
Step 1:
Connecting to battery (battery and cable not supplied)
Loosen the nuts on the positive (red) and negative (black) posts located on the inside of the board. Select the
appropriate cable guage and attach the positive and negative cable (not supplied) from the battery to the
positive (red) and negative (black) posts on the rear of the board. Ensure to add appropriate fusing. Feed the
cable through the open grommet located on the side of the board. Tighten the connections securely.
See Figure 1.
Step 2:
Connecting Solar and Alternator input
Ensure the input and solar connections are fitted with HD connectors that match those located on the right
side of the board, then plug them into matching connection. Note the solar input should be unregulated and
externally fused.
Step 3:
Connecting the Switches
The power board features 5 switches to control your output connections. Feed the open positive cable (see
wire B in wiring diagram below) from the back of the switch through the closed grommet on the top or left
side of the base bracket by cutting an opening in the grommet first. Wire to the positive side of the desired
load (e.g light) and earth as necessary.
Note maximum load per switch is 20A
Figure 2
6
WIRING DIAGRAMS
20A
8 B&S
Battery
Negative
7
1
7
8 B&S
20A
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
63254BL SWITCH
5mm
6
LVD50
3
+B1
10A
IDC25X
4
81143BL
+B1
63254BL
10 WAY FUSE BLOCK
+B2
2
3
20A
TEMP
9
150A
20A
(+) POST
OUT
8
+B2
SWITCH
Load/Charger
Negative
54480
54380BL
20A
8 B&S
IN
2 B&S
63254BL SWITCH63254BL SWITCH
(-) POST
PM SHUNT(500A)
2
56285BL
8
3
20A
3
63218BL
5mm
63254BL
SWITCH
7
7
8
54472 DUAL FUSE HOLDER 2
2
20A
B-
DISPLAY SCREEN (BM500-BT)
S-
56285BL
8 B&S
2
8
POSITIVE (+) BUS BAR
TRG
NEGATIVE (-) BUS BAR
3
5mm
52305
ANL FUSE HOLDER
5mm
3
81110BL
54445BL
81110BL
8
2 B&S
6
2
GRD
6
54472 DUAL FUSE HOLDER 1 (50A EACH)
7
54380BL
DUAL USB
ALT INPUT
8
INVERTER (IP1000)
DISPLAY
6
SOLAR INPUT
6
5A
2
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
7
6
81147BL
20A
DATESIGNATURE
APPROVAL
CUSTOMER
PRODUCT
MANAGER
G
F
E
D
C
B
A
B
C
D
F
G
H
Brown & Watson International Pty Ltd
1500 Ferntree Gully Road
Knoxfield VIC
3180
Australia ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
TOLERANCES UNLESS OTHERWISE STATED:
DO NOT SCALE DRAWING
0-50mm
50-1000mm
1000-2000mm
E
2000+mm
± 0.5
± 1.0
A
± 1.5
± 2.0
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
500-1000mm
HARNESSES
H
3
1000-5000mm
5000-10000mm
10000-15000mm
15000-20000mm
4
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12
5 6 7 8 9 10 11 12
1110987654321 12
11
FINAL
E
--GP
GP
BWI
E2
ICB1000 WIRING DIAGRAM
25.08.2023
V
IGNITION
SOLAR
AUX
GROUND
ALT
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
53836
W
7
20A
8 B&S
Battery
Negative
7
1
7
8 B&S
20A
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
63254BL SWITCH
5mm
6
LVD50
3
+B1
10A
IDC25X
4
81143BL
+B1
63254BL
10 WAY FUSE BLOCK
+B2
2
3
20A
TEMP
9
150A
20A
(+) POST
OUT
8
+B2
SWITCH
Load/Charger
Negative
54480
54380BL
20A
8 B&S
IN
2 B&S
63254BL SWITCH63254BL SWITCH
(-) POST
PM SHUNT(500A)
2
56285BL
8
3
20A
3
63218BL
5mm
63254BL
SWITCH
7
7
8
54472 DUAL FUSE HOLDER 2
2
20A
B-
DISPLAY SCREEN (BM500-BT)
S-
56285BL
8 B&S
2
8
POSITIVE (+) BUS BAR
TRG
NEGATIVE (-) BUS BAR
3
5mm
52305
ANL FUSE HOLDER
5mm
3
81110BL
54445BL
81110BL
8
2 B&S
6
2
GRD
6
54472 DUAL FUSE HOLDER 1 (50A EACH)
7
54380BL
DUAL USB
ALT INPUT
8
INVERTER (IP1000)
DISPLAY
6
SOLAR INPUT
6
5A
2
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
7
6
81147BL
20A
DATESIGNATURE
APPROVAL
CUSTOMER
PRODUCT
MANAGER
G
F
E
D
C
B
A
B
C
D
F
G
H
Brown & Watson International Pty Ltd
1500 Ferntree Gully Road
Knoxfield VIC
3180
Australia ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
TOLERANCES UNLESS OTHERWISE STATED:
DO NOT SCALE DRAWING
0-50mm
50-1000mm
1000-2000mm
E
2000+mm
± 0.5
± 1.0
A
± 1.5
± 2.0
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
500-1000mm
HARNESSES
H
3
1000-5000mm
5000-10000mm
10000-15000mm
15000-20000mm
4
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12 5 6 7 8 9 10 11 12
1110987654321 12
11
FINAL
E
--GP
GP
BWI
E2
ICB1000 WIRING DIAGRAM
25.08.2023
V
IGNITION
SOLAR
AUX
GROUND
ALT
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
53836
W
8
63254BL
SWITCH
+B1
20A
8
63218BL
6
3
IDC25X
54480
2 B&S
2
(+) POST
20A
LVD50
2 B&S
4
2
8 B&S
200A
5mm
3
6
S-
OUT
+B1
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
20A
DISPLAY SCREEN (BM500-BT)
63254BL
54472 DUAL FUSE HOLDER 1 (50A EACH)
20A
1
8 B&S
Load/Charger
Negative
IN
20A
63254BL SWITCH
DISPLAY
81110BL
56285BL
6
81110BL
6
6
8
DUAL USB
5mm
INVERTER (IP1500)
ANL FUSE HOLDER
2
3
3
8 B&S
+B2
2
81143BL
63254BL SWITCH
8
+B2
56285BL
NEGATIVE (-) BUS BAR
(-) POST
20A
7
54445BL
54380BL
81147BL
3
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
GRD
SWITCH
6
TEMP
54380BL
POSITIVE (+) BUS BAR
Battery
Negative
7
5mm
3
TRG
7
20A
52305
9
10A
10 WAY FUSE BLOCK
8
63254BL SWITCH
B-
20A
54472 DUAL FUSE HOLDER 2
7
5mm
8 B&S
PM SHUNT(500A)
2
5A
7
SOLAR INPUT
7
ALT INPUT
2
8
8
DATE
CUSTOMER
APPROVAL
SIGNATURE
PRODUCT
MANAGER
H
G
F
D
C
B
A
A
B
C
E
F
G
DO NOT SCALE DRAWING
Brown & Watson International Pty Ltd
1500 Ferntree Gully Road
3180
Australia ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
TOLERANCES UNLESS OTHERWISE STATED:
Knoxfield VIC
0-50mm
50-1000mm
1000-2000mm
H
2000+mm
3
± 0.5
D
± 1.0
± 1.5
± 2.0
4
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
E
500-1000mm
HARNESSES
1000-5000mm
5000-10000mm
10000-15000mm
15000-20000mm
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12 56789101112
1110987
654321
12
11
FINAL 25.08.2023
ICB1500 WIRING DIAGRAM
--
E
GP
GP
BWI
E2
IGNITION
SOLAR
AUX
GROUND
ALT
53840
WV
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
9
63254BL
SWITCH
+B1
20A
8
63218BL
6
3
IDC25X
54480
2 B&S
2
(+) POST
20A
LVD50
2 B&S
4
2
8 B&S
200A
5mm
3
6
S-
OUT
+B1
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
20A
DISPLAY SCREEN (BM500-BT)
63254BL
54472 DUAL FUSE HOLDER 1 (50A EACH)
20A
1
8 B&S
Load/Charger
Negative
IN
20A
63254BL SWITCH
DISPLAY
81110BL
56285BL
6
81110BL
6
6
8
DUAL USB
5mm
INVERTER (IP1500)
ANL FUSE HOLDER
2
3
3
8 B&S
+B2
2
81143BL
63254BL SWITCH
8
+B2
56285BL
NEGATIVE (-) BUS BAR
(-) POST
20A
7
54445BL
54380BL
81147BL
3
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
GRD
SWITCH
6
TEMP
54380BL
POSITIVE (+) BUS BAR
Battery
Negative
7
5mm
3
TRG
7
20A
52305
9
10A
10 WAY FUSE BLOCK
8
63254BL SWITCH
B-
20A
54472 DUAL FUSE HOLDER 2
7
5mm
8 B&S
PM SHUNT(500A)
2
5A
7
SOLAR INPUT
7
ALT INPUT
2
8
8
DATE
CUSTOMER
APPROVAL
SIGNATURE
PRODUCT
MANAGER
H
G
F
D
C
B
A
A
B
C
E
F
G
DO NOT SCALE DRAWING
Brown & Watson International Pty Ltd
1500 Ferntree Gully Road
3180
Australia ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
TOLERANCES UNLESS OTHERWISE STATED:
Knoxfield VIC
0-50mm
50-1000mm
1000-2000mm
H
2000+mm
3
± 0.5
D
± 1.0
± 1.5
± 2.0
4
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
E
500-1000mm
HARNESSES
1000-5000mm
5000-10000mm
10000-15000mm
15000-20000mm
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12 56789101112
1110987
654321
12
11
FINAL 25.08.2023
ICB1500 WIRING DIAGRAM
--
E
GP
GP
BWI
E2
IGNITION
SOLAR
AUX
GROUND
ALT
53840
WV
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
10
8 B&S
54380BL
LVD50
(+) POST
2
20A
8
63218BL
POSITIVE (+) BUS BAR
20A
IN
20A
10A
(-) POST
00 B&S
DISPLAY
+B2
5mm
250A
1
5mm
7
4
20A
5mm
20A
10 WAY FUSE BLOCK
8 B&S
2
8
3
DUAL USB
6
81147BL
3
5A
81110BL
5mm
56285BL
56285BL
54480
Battery
Negative
8
66
SOLAR INPUT
IDC25X
Load/Charger
Negative
3
GRD
S-
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
52305
81110BL
B-
8
ALT INPUT
2
+B2
OUT
TRG
63254BL
81143BL
63254BL
SWITCH
9
3
ANL FUSE HOLDER
8 B&S
INVERTER (IP2000)
SWITCH63254BL SWITCH
20A
54472 DUAL FUSE HOLDER 2
+B1
63254BL SWITCH
54445BL
54472 DUAL FUSE HOLDER 1 (50A EACH)
20A
2
DISPLAY SCREEN (BM500-BT)
8
20A
7
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
7
8 B&S
8
3
63254BL SWITCH
7
NEGATIVE (-) BUS BAR
PM SHUNT(500A)
00 B&S
7
+B1
6
6
2
54380BL
2
36
7
TEMP
CUSTOMER
PRODUCT
MANAGER
SIGNATURE
APPROVAL
DATE
H
G
E
D
C
A
A
B
C
D
E
F
H
DO NOT SCALE DRAWING
Brown & Watson International Pty Ltd
Knoxfield VIC
3180
Australia
3
ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
4
TOLERANCES UNLESS OTHERWISE STATED:
0-50mm
50-1000mm
1500 Ferntree Gully Road 1000-2000mm
2000+mm
± 0.5
G
± 1.0
± 1.5
± 2.0
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
500-1000mm
B
HARNESSES
1000-5000mm
5000-10000mm
F
10000-15000mm
15000-20000mm
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12
5 6 7 8 9 10 11 12
1110987
654321
12
2 --GP
GP
BWI
25.08.2023
E
ICB2000 WIRING DIAGRAM
E
11
FINAL
IGNITION
SOLAR
AUX
GROUND
ALT
WV
53842
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
11
8 B&S
54380BL
LVD50
(+) POST
2
20A
8
63218BL
POSITIVE (+) BUS BAR
20A
IN
20A
10A
(-) POST
00 B&S
DISPLAY
+B2
5mm
250A
1
5mm
7
4
20A
5mm
20A
10 WAY FUSE BLOCK
8 B&S
2
8
3
DUAL USB
6
81147BL
3
5A
81110BL
5mm
56285BL
56285BL
54480
Battery
Negative
8
66
SOLAR INPUT
IDC25X
Load/Charger
Negative
3
GRD
S-
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
52305
81110BL
B-
8
ALT INPUT
2
+B2
OUT
TRG
63254BL
81143BL
63254BL
SWITCH
9
3
ANL FUSE HOLDER
8 B&S
INVERTER (IP2000)
SWITCH63254BL SWITCH
20A
54472 DUAL FUSE HOLDER 2
+B1
63254BL SWITCH
54445BL
54472 DUAL FUSE HOLDER 1 (50A EACH)
20A
2
DISPLAY SCREEN (BM500-BT)
8
20A
7
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
7
8 B&S
8
3
63254BL SWITCH
7
NEGATIVE (-) BUS BAR
PM SHUNT(500A)
00 B&S
7
+B1
6
6
2
54380BL
2
36
7
TEMP
CUSTOMER
PRODUCT
MANAGER
SIGNATURE
APPROVAL
DATE
H
G
E
D
C
A
A
B
C
D
E
F
H
DO NOT SCALE DRAWING
Brown & Watson International Pty Ltd
Knoxfield VIC
3180
Australia
3
ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
4
TOLERANCES UNLESS OTHERWISE STATED:
0-50mm
50-1000mm
1500 Ferntree Gully Road 1000-2000mm
2000+mm
± 0.5
G
± 1.0
± 1.5
± 2.0
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
500-1000mm
B
HARNESSES
1000-5000mm
5000-10000mm
F
10000-15000mm
15000-20000mm
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12 5 6 7 8 9 10 11 12
1110987
654321
12
2 --GP
GP
BWI
25.08.2023
E
ICB2000 WIRING DIAGRAM
E
11
FINAL
IGNITION
SOLAR
AUX
GROUND
ALT
WV
53842
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
12
8 B&S
54380BL
LVD50
(+) POST
2
20A
8
63218BL
POSITIVE (+) BUS BAR
20A
IN
20A
10A
(-) POST
63254BL
SWITCH
DISPLAY
+B2
5mm
INVERTER (IP3000)
1
5mm
7
4
20A
5mm
20A
10 WAY FUSE BLOCK
8 B&S
2
8
3
DUAL USB
6
81147BL
3
5A
81110BL
5mm
56285BL
56285BL
54480
Battery
Negative
8
66
2
IDC25X
Load/Charger
Negative
3
GRD
S-
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
52305
81110BL
B-
8
00 B&S
2
+B2
OUT
TRG
63254BL
81143BL
SOLAR INPUT
9
3
ANL FUSE HOLDER
8 B&S
00 B&S
SWITCH63254BL SWITCH
20A
54472 DUAL FUSE HOLDER 2
+B1
63254BL SWITCH
54445BL
54472 DUAL FUSE HOLDER 1 (50A EACH)
20A
2
DISPLAY SCREEN (BM500-BT)
8
20A
7
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
7
8 B&S
8
3
63254BL SWITCH
7
NEGATIVE (-) BUS BAR
PM SHUNT(500A)
350A
7
+B1
6
6
2
54380BL
ALT INPUT
36
7
TEMP
CUSTOMER
PRODUCT
MANAGER
SIGNATURE
APPROVAL
DATE
H
G
E
D
C
A
A
B
C
D
E
F
H
DO NOT SCALE DRAWING
Brown & Watson International Pty Ltd
Knoxfield VIC
3180
Australia
3
ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
4
TOLERANCES UNLESS OTHERWISE STATED:
0-50mm
50-1000mm
1500 Ferntree Gully Road 1000-2000mm
2000+mm
± 0.5
G
± 1.0
± 1.5
± 2.0
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
500-1000mm
B
HARNESSES
1000-5000mm
5000-10000mm
F
10000-15000mm
15000-20000mm
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12 5 6 7 8 9 10 11 12
1110987
654321
12
2 --GP
GP
BWI
25.08.2023
E
ICB3000 WIRING DIAGRAM
E
11
FINAL
IGNITION
SOLAR
AUX
GROUND
ALT
WV
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
53846
13
8 B&S
54380BL
LVD50
(+) POST
2
20A
8
63218BL
POSITIVE (+) BUS BAR
20A
IN
20A
10A
(-) POST
63254BL
SWITCH
DISPLAY
+B2
5mm
INVERTER (IP3000)
1
5mm
7
4
20A
5mm
20A
10 WAY FUSE BLOCK
8 B&S
2
8
3
DUAL USB
6
81147BL
3
5A
81110BL
5mm
56285BL
56285BL
54480
Battery
Negative
8
66
2
IDC25X
Load/Charger
Negative
3
GRD
S-
RJ45 CABLE
(SUPPLIED WITH DISPLAY)
52305
81110BL
B-
8
00 B&S
2
+B2
OUT
TRG
63254BL
81143BL
SOLAR INPUT
9
3
ANL FUSE HOLDER
8 B&S
00 B&S
SWITCH63254BL SWITCH
20A
54472 DUAL FUSE HOLDER 2
+B1
63254BL SWITCH
54445BL
54472 DUAL FUSE HOLDER 1 (50A EACH)
20A
2
DISPLAY SCREEN (BM500-BT)
8
20A
7
NOTE: CABLES MARKED
IN GREEN
ARE SUPPLIED
& MAY NEED
TO BE EXTENDED
& LUGS ADDED TO MATCH
CONNECTION POINT
LVD TO BE SET AT 10.5V
7
8 B&S
8
3
63254BL SWITCH
7
NEGATIVE (-) BUS BAR
PM SHUNT(500A)
350A
7
+B1
6
6
2
54380BL
ALT INPUT
36
7
TEMP
CUSTOMER
PRODUCT
MANAGER
SIGNATURE
APPROVAL
DATE
H
G
E
D
C
A
A
B
C
D
E
F
H
DO NOT SCALE DRAWING
Brown & Watson International Pty Ltd
Knoxfield VIC
3180
Australia
3
ABN 29 004 250 748THIRD ANGLE PROJECTION
DIMENSION UNITS = mm
LINEAR FABRICATION
4
TOLERANCES UNLESS OTHERWISE STATED:
0-50mm
50-1000mm
1500 Ferntree Gully Road 1000-2000mm
2000+mm
± 0.5
G
± 1.0
± 1.5
± 2.0
RADIAL = ± 0.5
ANGULAR = ± 1°
0-500mm
500-1000mm
B
HARNESSES
1000-5000mm
5000-10000mm
F
10000-15000mm
15000-20000mm
± 10
± 15
± 20
± 30
± 40
± 50
BWI ENGINEER:
MATERIAL:
FINISH:
COLOUR:
SHEET OF
P/No
DESC
REV
DRG REF
CUSTOMER:
REV DATE
CHG DETAILS DRN CHKD
SCALE: A3
12 5 6 7 8 9 10 11 12
1110987
654321
12
2 --GP
GP
BWI
25.08.2023
E
ICB3000 WIRING DIAGRAM
E
11
FINAL
IGNITION
SOLAR
AUX
GROUND
ALT
WV
UPDATES:
M-4 and ACC-9 position switched
63254BL and 63218BL position switched
Battery posts position swapped
Letters removed
Temp and display cable repositioned BM500-BT
M-4
ACC-9
8
7
6
3
2
1
53846
IS545
Issue 2: 25.08.23
WARRANTY STATEMENT
Applicable only to product sold in Australia
Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03) 9730 6000,
fax (03) 9730 6050, warrants that all products described in its current catalogue (save and except for all
bulbs and lenses whether made of glass or some other substance) will under normal use and service be free
of failures in material and workmanship for a period of five (5) years (unless this period has been extended
as indicated elsewhere) from the date of the original purchase by the consumer as marked on the invoice.
This warranty does not cover ordinary wear and tear, abuse, alteration of products or damage caused by the
consumer. Projecta solar panels are covered by a 1 year warranty for materials and workmanship and a 20
year warranty for at least 80% power output.
To make a warranty claim the consumer must deliver the product at their cost to the original place
of purchase or to any other place which may be nominated by either BWI or the retailer from where
the product was bought in order that a warranty assessment may be performed. The consumer must
also deliver the original invoice evidencing the date and place of purchase together with an explanation
in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the product then BWI reserves the
right to repair or replace it at its discretion. In the event that a major failure is determined the consumer
will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable
loss or damage.
This warranty is in addition to any other rights or remedies that the consumer may have under State or
Federal legislation.
IMPORTANT NOTE
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You
are entitled to a replacement or refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods
fail to be of acceptable quality and the failure does not amount to a major failure.
Distributed by
AUSTRALIA
Brown & Watson International Pty. Ltd.
Knoxfield Victoria 3180
Phone: (03) 9730 6000
Fax: (03) 9730 6050
National Toll Free: 1800 113 443
NEW ZEALAND OFFICE
Griffiths Equipment Ltd.
19 Bell Avenue,
Mount Wellington,
Auckland 1060, New Zealand
Phone: (09) 525 4575
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Projecta ICB1000 Operating instructions

Type
Operating instructions

Projecta ICB1000 is a 12V power management system ideal for vehicles like Ute canopies, 4WDs, and Caravans. It features a DC/DC charger with solar and alternator inputs, switches, and sockets to manage power. The system also includes a Bluetooth-enabled LCD display to monitor auxiliary battery status and a pure sine wave inverter to run 240V appliances off-grid. With easy installation and accessible fuse holders, the Projecta ICB1000 offers a convenient and reliable power solution for various applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI