  • Hello! I've reviewed the installation manual for the Clearfield Field Installable FlexConnector. This document provides detailed instructions on how to properly prepare the cable, apply heat shrink for water tight sealing, and securely attach the clips. I'm ready to help you with any questions you have about the installation process or the device itself.
  • What is the recommended cable preparation for a Field Installable FlexConnector?
    What heat shrink should be used for a water tight seal on standard FLATdrop cable?
    What heat shrink should be used for a water tight seal on SFF cable?
    What is the purpose of the clips on the Field Installable FlexConnector?
1
Field Installable FlexConnector
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019320 REV B - Aug 2022
Step 4: Pass breakout 3mm/900 mi-
cron cable through FlexConnector.
Step 1: Prep cable to YOURx length
(12 inches) cutting strength members
ush with black, outer cable sheath.
Installing the Field Installable FlexConnector
Figure 1
Figure 2
Step 5: Stop short of cable sheath.
Figure 5
Step 7: Attach clips to top and bottom of cable, teeth
in, even at cable sheath opening. A groove on the clip
allows for proper alignment.
Step 6: Align nose of clips to end of
black cable and sandwich together.
Figure 6
Figure 7
Nose
Teeth
Figure 4
(1) 3/4” x 3” long (004719)
Step 2: For water tight seal on standard
FLATdrop, feed the following length of
heat shrink onto cable for later use:
Step 3: For water tight seal on SFF,
feed the following lengths of heat
shrink onto cable for later use:
(1) 3/4” x 3” long (004719)
(1) 5/16” x 3” long (004458)
Figure 3
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
2
Field Installable FlexConnector
Installation Manual _________________________________________________________
Manual 019320 REV B - Aug 2022
Step 9: Pull FlexConnector (added in
Step 4) back over clips to snap into
FlexConnector holes, as shown. Push
until you hear a snap.
Step 8: Use pliers (as shown) to pinch
teeth to hold jacket.
DO NOT use needle nose pliers.
Figure 8 Figure 9
FlexConnector
Hole
Step 11: Slide the 3” piece (004719)
heat shrink tubing, covering the holes
on the FlexConnector and heat to
shrink.
Figure 11
Step 12 This will create a water tight
seal.
Figure 12
Step 13: Terminate ber to connector
per instructions (if applicable).
Figure 13
Step 10: For SFF cable only, slide the
smallest heatshrink, placing one end
just inside the back end of the Flex-
Connector. Shrink using a heat gun.
Figure 10
Cleareld College Product Training
www.seecleareld.com/training/cleareld-college/
certied-partnership-training.html