General Overview
Congratulations on your purchase of the Toledo Bluetooth
®
Vernier Caliper. This precision instrument
features the most modern technology with in-built Bluetooth
®
4.0 transmitter.
This Digital Vernier Caliper can be used in conjunction with the Toledo Bluetooth
®
software and
receiving dongle or app to enable complete wireless connectivity with PC, Android and iOS systems.
Additional Information
Maintenance
Always keep the Vernier Caliper in a dry
environment and locked in its designated
storage case when not in use. To protect
against rust.
Do not close the measuring spindle with the
anvil when not in use. Keep an open distance of
1-2 mm
Do not use aggressive products (alcohol,
trichloroethylene or others) to clean the
plastic parts
Do not keep the micrometer in places exposed
to sun, heat or humidity.
Important: Dry the instrument thoroughly after
exposure to moisture. This will guarantee
correct performance and operation
SWISS MADE
C
A
L
I
B
R
A
T
E
D
C
e
r
t
i
c
a
t
e
I
n
c
l
u
d
e
d
U
N
I
T
U
N
I
T
Precision instrument with built-in Bluetooth
®
wireless technology to enable direct data output to synchronised
devices E.g. PC, Smart Phone, Tablet
Water protected for heavy-duty work with coolants and lubricants, protection rating IP67 according to IEC 60529
Extra-large and bright digital display
Auto wake up and Auto off functions
Wireless transmission range up to 15m
Maximum error: 20µm
Powered by standard CR2032 button cell battery (3 years life per battery)
Supplied in heavy duty storage case with foam insert and firm locking clip
Bluetooth
®
software sold separately
Made in Switzerland
TOLEDO IS A REGISTERED
TRIDON BRAND
Battery Infromation
The display of the symbol indicates low
battery power and battery replacement is
required.
To replace battery:
322400
Battery (CR2032) Data/Favourite Button
Mode Button Set Button
Thumbwheel
Bluetooth
®
Specifications
Measuring Range 150mm/6"
Resolution 0.01mm/0.0005"
Maximum Error
100mm: 20µm
100-300mm: 30µm (DIN862)
Repeatability 10µm/0.0005"
Maximum Slider
Speed
2.5m per Sec/100" per Sec
Display Refresh Rate > 10 Seconds
Data Output Bluetooth
®
4.0 2.4Ghz
Mean Power
Consumption
45µA
Battery Life
Bluetooth® OFF: 8000h
Bluetooth® ON: See Autonomy
Working Temperature +5°C to +40°C
Storage Temperature -10°C to +60°C
Weight 175g
IP Specification IP 67 (IEC60529)
Radio Frequency 2.4 Ghz
Robustness FHSS
Latency < 6ms
Bluetooth
®
Specifications
Range:
Open Space: 15m
Industrial
Environment:
1 - 5m
Autonomy:
Continuous
Up to 2 months (always connected
with 4 values)
Saver
Up to 5 months (this instrument
sends value only when the
position has changed)
Blind/Push
Up to 7 months (value is sent
from the instrument (button) or
requested from the computer)
For further technical information please contact Tridon Customer Service on 1300 362 263
[MODE] Button
Enables the selection of the different menus (each key stroke activates the next menu)
[SET] Button
Enables the activation of a function assigned to the corresponding selected menu
[DATA] Button
Enables the transmission of data to connected devices via Bluetooth
®
4.0 transmitter
Start/Switching ON
• To start, press [MODE] or [SET]
Switching OFF
The instrument can be switched off completely for a long period of non-use, but this
will result in zero reset and all data will be lost. To fully switch off the instrument
press and hold [SET] untill «OFF» appears
Standby Mode
Standby mode is activated automatically after 20 minutes of inactivity
(unless automatic switch-off mode has been turned off)
Standby mode is a state of reduced consumption without loss of the reference
position. It can also be activated by pressing the [SET] button until the display
disappears
The instrument awakes automatically when it detects movement from the jaws, push
of a button or when requesting Data.
Reinitialising Instrument (Re-Setting)
The initial instrument setting can be restored at any time by a prolonged press (>4sec)
simultaneously on [MODE] or [SET] untill the message rESEt is displayed
Favourite settings
Favourite settings give direct access to a predefined function. Favourite
functions enable the user to configure the instrument according to their
needs. In order to access a favourite function the instrument must first be
unlocked by a prolonged press on the [MODE] Button.
1. SEt (False Zero): Zero setting at a defined point
2. Unit (Metric or Imperial): Unit of measurement selection
3. PrE (Pre-Set Values): Pre-setting of defined reading/value
4. bt (Wireless Bluetooth Connection): Wireless data transmission between
instrument and device
Wireless Technology
Toledo Bluetooth
®
precision instruments feature
an in-built Bluetooth® 4.0 transmitter to enable
complete wireless data transmission between
instrument and device. No additional attachments
are required to enable Bluetooth
®
connectivity,
but associated software and receiving dongle is
needed (sold separately)
To activate Bluetooth
®
Press the [MODE] button
until «BT» appears on the screen. Then press the
[SET] button to activate or deactivate the function
or to perform a reset of the connection, then press
[MODE] button to validate. A third menu allows
you to read the MAC (Bluetooth
®
) address.
The Bluetooth
®
connection procedure has
3 states:
1. Symbol
off - Disconnected Mode
2. Symbol
blinking - Advertising Mode
3. Symbol
on - Connected Mode
Connection
1. Activate Bluetooth
®
Smart compatible software
and hardware/App either on your PC, Tablet or
smartphone
2. Start the instrument. By default the Bluetooth
®
module is active and the instrument is available
for connection for 120s (Advertising Mode)
3. As soon as the device is detected, a connection
is established automatically. If no connection
is established during 120s, reactivate the
Bluetooth
®
module using the bt/On menu.
4. Instrument is ready to communicate
(connected mode)
Pairing
Pairing with the master is automatically done at
first connection.
To connect the instrument to a new master
(new pairing), it is necessary to clear all pairing
information on the instrument using the bt/rESEt
menu.
Menu System & FunctionsInstructions for Use
Press the [DATA] button to access the
range of favourite settings
To exit favourite settings and lock
the instrument requires a prolonged
press on the (DATA) button.
Data transmission
(default)
Hold display
Zero reset
Recall Preset
To avoid a wrong action, each menu is active only for 5s. When this period is
passed, the instrument switches automatically back to «Measuring Mode» as
long as no action has been performed to the [MODE] or [SET] button
  • Page 1 1
  • Page 2 2

TRIDON TOLEDO Vernier Caliper User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI