Andover Controls DI-6 AC HV Technical Manual

Category
Digital & analog I/O modules
Type
Technical Manual
UN-RELEASED
REVIEW COPY
2/20/98
Technical Manuals Online! - http://www.tech-man.com
Andover Controls Corporation
1998, Andover Controls Corporation
All Rights Reserved
No part of this publication may be reproduced, read or stored in a retrieval
system, or transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of
Andover Controls Corporation.
Produced in the United States of America.
Infinity is a trademark of Andover Controls Corporation. All other trademarks
are the property of their respective owners.
Continuum I/O Reference, Version: REVIEW February, 1998
Andover Controls part number: 30-3001-499
The information in this book is furnished for informational purposes only, is
subject to change without notice, and should not be construed as a commitment
by Andover Controls Corporation. Andover Controls Corporation, assumes no
liability for any errors or inaccuracies that may appear in this document.
Related Documents
Continuum Power Supply Reference, 30-3001-702
Continuum CPU Reference, 30-3001-701
Continuum Display Module Reference, 30-3001-711
Andover Controls Corporation
300 Brickstone Square
Andover, MA 01810
(978) 470-0555
fax: (978) 470-0946
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
Radio Interference
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions in this manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Note
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Avis
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage
radioélectrique édicté par le ministère des Communications du Canada.
Technical Manuals Online! - http://www.tech-man.com
Andover Controls Corporation
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
Contents
Introduction......................................................................1
Mechanical Installation....................................................4
Overall Dimensions....................................................................7
Door-Mounted Modules..............................................................8
Power-CPU Connections...............................................10
Connection of I/O Modules.......................................................11
Maximum Number of I/O Modules............................................12
Maximum Length of I/O Bus.....................................................12
Connecting Remote I/O Modules with RS-485.........................12
Termination Guidelines............................................................13
Individual Module Characteristics................................17
General Wiring Concerns.........................................................17
INPUT Modules
UI-8-10 / UI-8-10-10V.................................................................19
DI-6-AC / DI-6-AC-HV................................................................35
DI-8............................................................................................43
MI-6............................................................................................53
OUTPUT Modules
DM-20........................................................................................61
AO-4-8 / AO-4-8-O.....................................................................73
DO-4-R / DO-4-R-O....................................................................83
DO-6-TR ....................................................................................91
LO-2 / LO-2-O............................................................................99
MIXED Modules
AC-1.........................................................................................113
Technical Manuals Online! - http://www.tech-man.com
Andover Controls Corporation
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
1
TCX 865
ÈNTINUUM
I/O Systems
This manual describes the installation, care and use of all Continuum I/O modules.
The
Continuum
Ethernet-based intelligent building system allows you to mix and match
various combinations of DIN rail-mounted moduleshigh density I/O, CPU and power
supply, and your choice of several user interface modulesin a
single
controller location
to meet your building’s control and monitoring needs. With the
Continuum
system, as
your network grows, simply add or replace I/O modules as needed.
The
Continuum
I/O modules feature a sleek, lightweight casing designed for natural
convection cooling, and a 3-position front cover for easy, hands-free access. Built-in
quick-release fasteners at the back of each I/O module are provided for DIN rail
mountingno tools required. These fasteners also snap into a locked position for panel
mounting. Input and output connectors are located at the bottom of each I/O module and
are removable for easy field access and maintenance. All
Continuum
modules are
designed for mounting in an optional NEMA 1-style
Continuum
enclosure.
The
Continuum
I/O modules communicate with the
Continuum
NetController CPU
module. Like all
Continuum
modules, the I/O modules snap together directly via built-in
connectors on either side so network expansion is quick and easy. Both power
transmission and communication signals between the
Continuum
power supply module,
NetController CPU module, and all I/O modules feed through this connection. For added
convenience in certain applications, such as door control or lighting control, a single
module or groups of I/O modules can be remotely located and connected using approved
cable and powered from a local 24 VDC power supply. Each I/O module features its own
push-button for quick and easy network commissioning.
This document covers the standard Input and Output modules. For information
regarding the special Continuum enclosure door-mounted display modules
consult the Andover Controls
Continuum Display Module Reference
.
Technical Manuals Online! - http://www.tech-man.com
2
Andover Controls
I/O System Introduction
The Continuum I/O system is comprised of a series of modules separated by function
that connect via a common electrical communications bus. Each functional component is
enclosed in a plastic case containing all of its connections to the outside world. Modules
are connected to a central controller via a standard five conductor connector.
The Continuum system includes at least one power supply and a single controller
module. I/O modules provide the controller with the ability to interface with the outside
world. They connect directly and communicate with the CPU. The following is a typical
architecture drawing of a Continuum System:
Continuum I/O modules are available in INPUT, OUTPUT, MIXED and DISPLAY
varieties.
Power Supply I/O Modules
Controller
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
3
The INPUT modules available are:
UI-8-10; Universal Input Module
UI-8-10-10V; Universal Input Module
DI-6 AC; AC Digital Input Module
DI-6 AC HV; AC Digital Input Module
DI-8; Digital Input Module
DM-20; Digital Input/Output Module (for DIO-20)
MI-6; MilliAmp Input Module
The OUTPUT modules available are:
AO-4-8-O; Analog Output Module (with override)
AO-4-8; Analog Output Module
DO-4-R-O; Relay Output Module (with override)
DO-4-R; Relay Output Module
DO-6-TR; Triac Output Module
LO-2-O; Lighting Output Module (with override)
LO-2; Lighting Output Module
The MIXED modules available are:
AC-1; Door, Access Control, Wiegand Module
AC-1-ABA; Door, Access Control, ABA Module
The DISPLAY modules available are:
LB-8; 8-Channel LED Bar Display/ 8 Push Button Module
LS-8; 8-Channel, 3 Digit 7-Segment LED Display/ 16 Push Button Module
LC-1; 2-Line LCD Display/ 12 Push Button Module
VM-1; Voice Record and Playback Module
GA-40; Graphic Annunciator Panel
Technical Manuals Online! - http://www.tech-man.com
4
Andover Controls
Mechanical Installation
Each I/O module, except the Display variety, is enclosed in the same standard plastic
case that is designed to be mounted on a standard DIN rail or fastened to a panel.
Note: In order to meet agency requirements, it is necessary that the modules along
with the power supply and controller be housed in another metal enclosure i.e., a
NEMA box or the new Andover Controls Continuum enclosure.
The standard I/O module plastic case is illustrated below:
Status indicators and operator switches are located on the indicator panel. Other
switches available for module configuration may be accessed by lifting the hinged door to
the module as shown.
Status Indicators
& some switches
Connections to
controlled/sensed
e
q
uipment
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
5
Wiring to controlled points or sensors is accomplished via a standard removable screw
terminal block located at the bottom of the module behind the door. An open area at the
bottom of the case allows wires to exit in an appropriate manner.
On the back of each module are molded DIN rail guide fingers. The design allows the
module to easily hook onto and slide along a standard DIN rail.
With the mounting brackets extended outward, hook the module onto the DIN rail as
shown below:
Locking Fingers
Technical Manuals Online! - http://www.tech-man.com
6
Andover Controls
Slide the module into position.
Press the lower mounting bracket inward until it locks the module in place.
Press the upper bracket into its locked position as well.
Once the module is in the desired position, it is locked to the rail by pushing the bottom
clamps inward. After the bottom is secure, press the top clamp inward to complete the
operation.
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
7
Overall Dimensions
The overall dimensions of the standard I/O case are as shown:
6.70''
(170.2 mm)
2.50 ''
(63.5 mm) 3.50 ''
(88.5 mm)
Technical Manuals Online! - http://www.tech-man.com
8
Andover Controls
Enclosure-Mounted Modules
The modules that are designed to be mounted to the new Andover Controls Continuum
enclosure fit into openings left by removing panels in the front door.
The new enclosure provides a place to mount a power supply, CPU and up to ten DIN rail
mounted I/O modules. Several display modules can be affixed to the front panel.
The enclosure is a 6” deep NEMA box with integral display panels, DIN rails, cable
troughs and a battery storage compartment.
The enclosure features three DIN rails and cable management accessories. Use of the
new enclosure is not required, however, it provides a convenient method of constructing
small local systems.
DIN Rail
Cable Trough
Battery
Storage
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
9
The front door of the enclosure contains removable sections into which special operator
display and control modules may be mounted. Alternately, Plexiglas panels may be used
to view the status lights of all internal modules when the door is closed.
Removable
Display Panels
Spacers for
Additional Displays
Technical Manuals Online! - http://www.tech-man.com
10
Andover Controls
Power-CPU Connections
The Continuum NetController CPU module includes a connector on the upper right
side of its case for further distribution of the 24 VDC input power and special I/O
communications signals to all I/O modules. Continuum I/O modules use these signals
for power and communications as well.
The power-I/O connector is a five pin male assembly that is designed to easily insert
directly into the left side (input) connector of any I/O module. The signals within that
connector are as follows:
PIN Function
5 +24 VDC
4 24 VDC Return
3 Ground
2 Comm B
1 Comm A
The system power supply generates a +24 VDC source for all modules in the system.
This power source is received through the input power connector on the left side of
the CPU module and sent through to pins 4 and 5 of this connector. Pin 3 (Ground) is
intended as a signal ground connection.
Communications between the CPU and I/O modules is through a two-signal serial
interface that can be internally configured as either RS 485 or Echelon LON FTT-10.
Pins 1 and 2 (Comm B and Comm A) provide the electrical connection for this
interface.
5
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
11
Connection of I/O Modules
The CPU can directly connect to I/O without the use of cables through a system of
built-in plugs and jacks. All I/O modules include two complementary module inter-
connectors.
Creating a system is as simple as physically plugging the modules together.
In vertical extended systems, I/O modules may be located above or below other
modules. In this case, cable assemblies bridge the I/O modules together.
The cable necessary to connect the CPU and external I/O modules is five conductor
and would be attached using a plug-in screw terminal connector. Connection
between the modules is one-to-one straightforward wiring as shown below:
This connector is available from Andover Controls under part number 01-2050-283;
Wieland manufactures it under part number 25.340.0553.0.
Power Suppl
y
CPU I/O I/O
5
4
3
2
1
5
4
3
2
1
Technical Manuals Online! - http://www.tech-man.com
12
Andover Controls
Maximum Number of I/O Modules
There is no operational limit to the number of I/O modules connected to the CPU except
the capacity of the power supply. It is possible to insert auxiliary power supplies into the
I/O bus to increase the number of modules supported.
To determine the maximum number of I/O modules your system can support, subtract the
power requirements for each module from the maximum available from your power
supply.
PS 120/240 AC 50 U, UPS power supply provides 35 Watts of power
PS 120/240 AC 50, non-UPS power supply provides 50 Watts of power
PS –48 DC 50, Battery operated power supply provides 50 Watts of power
NetController requires 15 Watts of power
Start by subtracting the NetController from the power available from your power supply.
PS 120/240 AC 50 U
35 – 15 = 20 Watts of available power for I/O
PS 120/240 AC 50
50 – 15 = 35 Watts of available power for I/O
PS –48 DC 50
50 – 15 = 35 Watts of available power for I/O
The power requirements for each I/O module is listed in the
Continuum I/O System
Reference Guide
ACC # 30-3001-499 and can be found on individual data sheets.
Maximum Length of I/O Bus
A repeater is necessary if the cable lengths get too long. The following are
recommendations regarding cable lengths for both RS-485 and FTT-10 interfaces:
RS-485 Repeater required if length is >2000 ft. (610 m) or after 32 modules.
FTT-10 Repeater required if length is >8858 ft. (2700 m) bus topology
>1640 ft. (500 m) free topology
Connecting Remote I/O Modules with RS-485
The Continuum system allows I/O modules to be placed in a remote location from the
CPU (NetController). However, long cable lengths can cause signal communications
problems on the Power/I-O bus.
When locating an I/O module remotely it is necessary to add a 120 terminator to the
bus to compensate for the distance. The terminator must be connected at both ends of
the bus for proper operation.
Technical Manuals Online! - http://www.tech-man.com
Continuum I/O System Reference
13
Termination Guidelines
The following are typical installations that indicate the placement of the terminator:
Simple CPU and 1 remote I/O Module:
The I/O Bus that needs to be terminated is the one formed by the cable attaching the
remote module to the CPU. In this case, a terminator resistor is connected across the
communications lines (pins 1 & 2) directly at the NetController and again at the remote
I/O module.
CPU
5
4
3
2
1
5
4
3
2
1
120
Resistor 120
Resistor Remote
I/O
Module
Technical Manuals Online! - http://www.tech-man.com
14
Andover Controls
CPU with local and 1 remote I/O Module:
The I/O Bus that needs to be terminated is the one formed by the cable that starts at
the NetController and ends at the remote module. The bus that extends from the
NetController through the local I/O stack does not need termination. In this case, the
terminator resistor is connected directly across the communications lines (pins 1 & 2) at
the NetController and again at the remote I/O module.
CPU
5
4
3
2
1
5
4
3
2
1
120
Resistor
120
Resistor
Remote
I/O
Module
5
4
3
2
1
Local
I/O Local
I/O
Technical Manuals Online! - http://www.tech-man.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139

Andover Controls DI-6 AC HV Technical Manual

Category
Digital & analog I/O modules
Type
Technical Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI