Astria Fireplaces Rhapsody Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
HEARTH PRODUCTS
KITS AND ACCESSORIES
P/N 900077-05
Rev. A 09/2016
LINEAR DIRECT-VENT FIREPLACES
ACCESSORY KITS
INSTALLATION INSTRUCTIONS FOR REQUIRED AND OPTIONAL ACCESSORIES
FOR USE ON 42- AND 54-INCH LINEAR DIRECT-VENT GAS FIREPLACES
[FIREPLACE MODELS: Rhapsody42 and Rhapsody54 Series]
DANGER
HOT GLASS WILL CAUSE BURNS. DO NOT
TOUCH GLASS UNTIL COOLED.
NEVER
ALLOW CHILDREN TO TOUCH GLASS.
Fireplaces surfaces get EXTREMELY HOT!
Install only when fi replace is OFF and COLD.
The glass on the front of the fi replace reaches
EXTREMELY HIGH temperatures and can cause severe
burns if touched. Even after the gas is turned off,
replace surfaces remain extremely hot.
Keep children away from an operating fi replace. Closely
supervise children in any room where a fi replace is
operating to prevent contact with glass.
CAUTION
RISK OF PERSONAL INJURY OR PROPERTY DAMAGE.
Never operate fireplace without liner panels installed. These
appliances are NOT approved for operation without liner panels.
Do NOT abuse glass doors by striking or slamming shut
Never operate fi replace with glass door assembly removed.
Handle glass door assembly with extreme care.
Replace damaged glass door assembly with approved
replacement assembly only.
Use only media approved for use with these fi replaces
(as applicable). Failure to use approved media may result
in sooting, delayed ignition, or other improper fi replace
operation, and may void the warranty.
NOTICE
Read all steps before starting installation.
LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
All warnings, precautions, and instructions in the Installation
and Operation Instructions provided with the appliance also
apply to these instructions.
If you encounter any problems, need clarifi cation of these
instructions, or are not qualifi ed to properly install this
kit, contact your local distributor or dealer.
Figure 1 - 54 in. Rhapsody linear gas fi replaces with
designer fl oor kit and Illusion Cityscape fi rebox
panel kit (both in black porcelain).
GENERAL INFORMATION
This document contains installation instructions for the following
required and optional accessories for Rhapsody® linear direct-
vent gas fi replaces manufactured by INNOVATIVE HEARTH
PRODUCTS (IHP).
Kit descriptions, catalog/model numbers, and contents are listed
on the next page.
Required Accessory Kits
The following accessory kits are REQUIRED for complete fi re-
place installation.
NOTE: Ensure these kits are available before installing the fi re-
place.
Firebox Panel Kit (Rhapsody models only)
• Floor Kit (Rhapsody models only)
Media Kit *
* Media kit required with “Designer" style fl oor kits only (Rhapsody models only)
Media must not be used with Refection fl oor.
Optional Accessory Kits
The following accessories are OPTIONAL. However, to minimize
required labor, all options should be installed at time of fi replace
installation, if possible.
• Surround Kit
• Bezel Kit
Firebox Backlight Kit ** (Rhapsody models only)
Power Vent Kit
(see manual 506022-01 for installation instructions)
** Firebox backlight kit for use with "Cityscape" and "Illusion" style fi rebox
panel kits (Rhapsody models only)
REQUIRED TOOLS
NOTE: Power tools are NOT recommended when installing fi re-
place accessories, especially porcelain fi rebox panels.
5/16" Hex-head Nut Driver
#3 Phillips Head Screwdriver
(for fi replace door removal/installation)
Glass Cleaner (non-ammoniated)
• Non-abrasive rag
• High-temperature sealant
(e.g., Mill-Pac®; if installing fi rebox backlight kit)
• Safety Glasses
Protective Work Gloves
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
2
REQUIRED ACCESSORIES
Firebox Panel Kits
(13) #10-16 x 3/8 Hex-head Sheet Metal Screws
(2) Side Panels
(1) Back Panel
Illusion Cityscape Back Panel Illusion Metroscape Back Panel
42 in.
Illusion Cityscape—Black Porcelain * H8832 IPK-CBLKP-RAP42
Illusion Metroscape—Black Porcelain * H8833 IPK-MBLKP-RAP42
Nake—Black Porcelain H8834 NPK-BLP-RAP42
Nake—Black Satin Paint H8835 NPK-BLS-RAP42
54 in.
Illusion Cityscape—Black Porcelain * H8420 IPK-CBLKP-RAP54
Illusion Metroscape—Black Porcelain * H8421 IPK-MBLKP-RAP54
Nake—Black Porcelain H8422 NPK-BLP-RAP54
Nake—Black Satin Paint H8423 NPK-BLS-RAP54
Table 1 - Required Firebox Panel Kits
* “Illusion” and "Cityscape" style Firebox Panel Kits are designed for use with
the Illusion and Cityscape Firebox Panel Backlight Kits.
Floor Kits
(4) #10-16 x 3/8 Hex-head Sheet Metal Screws
(1) Rear Floor Section
(1) Front Floor Section
Designer Floor Kit
Description Cat. No. Model No.
42 in.
Refl ection—Black Porcelain H8838 RFK-BLP-RAP42
Designer—Black Porcelain ** H8836 DFK-BLP-RAP42
Designer—Black Satin ** H8837 DFK-BLS-RAP42
54 in.
Refl ection—Black Porcelain H8425 RFK-BLP-RAP54
Designer—Black Porcelain ** H8427 DFK-BLP-RAP54
Designer—Black Satin ** H8426 DFK-BLS-RAP54
Table 2 - Required Floor Kits
** Designer fl oor kits require one media kit.
Media Kits
WARNING
DO NOT use Media with Refl ection fl oor. Improper operation
may occur.
(1) Media, 5 lb bag
NOTE: See media kit instructions (P/N 900077-07).
Description Cat. No. Model No.
Refl ective Black H8412 CRSHGL-RBLK
Refl ective Blue H8424 CRSHGL-RBLU
Platinum H8413 CRSHGL-P
Goldfi nger H8538 CRSHGL-GF
Copper H8539 CRSHGL-C
Table 3 - Required Media Kits
OPTIONAL ACCESSORIES
Firebox Panel Backlight Kits
(1) Left Lamp Bracket
(2) Right Lamp Brackets
• (3) Lamps
(1) Multi-Wire Harness
• (1) Profl ame I Power Harness
(1) SimFlame™ I Assembly
• (1) Refl ector Panel
(1) ProFlame™ II Light Wire Harness
Description Cat. No. Model No.
42 in. Illusion Firebox Panel Backlight Kit *** H8866 IPBLK-RAP42
54 in. Illusion Firebox Panel Backlight Kit *** H8429 IPBLK-RAP54
Table 4 - Optional Firebox Backlight Kits
*** "Cityscape" and "Illusion" fi rebox backlight kit is designed for use with Citystape
and Illusion style Firebox Panel Kits.
Surround Kits
(9) #10-16 x 3/8 Hex-head Sheet Metal Screws
NOTE: Surround and bezel should be installed together.
Description Cat. No. Model No.
42 in. Black Satin F2259 CS-BLS-RAP42
54 in. Black Satin F2256 CS-BLS-RAP54
Table 5 - Optional Surround Kits
Bezel Kits
(1) Bezel Assembly
NOTE: Surround and bezel should be installed together.
Description Cat. No. Model No.
42 in.
Black Satin F2269 BZL-BLS-RAP42
Black Nickel F2267 BZL-BLNI-RAP42
Brushed Nickel F2268 BZL-BRNI-RAP42
54 in.
Black Satin F2266 BZL-BLS-RAP54
Black Nickel F2264 BZL-BLNI-RAP54
Brushed Nickel F2265 BZL-BRNI-RAP54
Table 6 - Optional Bezel Kits
Other Optional Accessories
Description Cat. No. Model No.
Power Vent Kit (manual P/N 506022-01) H7387 LPVK-110****
Adaptor Kit RAP54 (manual P/N 900077-04) H8574 PVK-RAP54 ****
Gas Conversion Kit, NG to LP (manual P/N 506019-90) H8540 GCK-RAPNP
Table 7 - Other Optional Accessories
**** For use with 42 in. and 54 in. models.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
3
To remove optional Bezel:
Grasp lower portion of bezel frame and pull forward to release
from bottom of door.
Swing bezel out slightly and lift up to clear top bracket from
door frame.
If Bezel is installed, barrier frame shown in Figure 2 will not be
present.
Remove glass door assembly
1. Remove the three (3) screws securing the lower edge of the
glass door assembly to the fi replace (Figure 3).
2. Grasp the glass door assembly by the sides, swing the lower
edge out, and then lift up to unhook it from the fi replace.
NOTE: Take care not to damage the glass.
3. Set aside the screws and glass door assembly in a secure
location for later reinstallation.
Glass Door Assembly
[CROSS-SECTION]
Barrier
Flanges
Door Trim
Barrier
Figure 2 - Removing the bezel
INSTALLATION INSTRUCTIONS
Complete all steps in the order shown, including the installation
of optional accessories (if applicable).
Remove barrier assembly
1. Remove the barrier assembly by lifting it up to disengage its
notches from tabs and pull directly away from the fi replace.
2. To replace the barrier if damaged, remove the three (3)
screws from the top and bottom and one (1) screw from
each side. Reverse these instructions to install the new
manufacturer's barrier (Figure 2).
Figure 3 - Removing the glass door assembly
Remove baffl e from fi replace fl oor, if installed
1. If unpacking the fi replace for the fi rst time, remove the
baffl e from fi replace fl oor, where it is packed for shipping
(Figure 4).
2. Set aside the baffl e in a secure location for later installation.
Baffl e (as shipped)
Figure 4 - Removing the baffl e
Access the control compartment
1. Remove the two (2) screws securing the burner assembly
to the burner brackets. Carefully slide the burner to the left,
to clear the venturi from the orifi ce. Rotate the burner to
release the air shutter adjustment rod from the air shutter
lever (Figure 5). Lift and remove the burner assembly,
and set aside the screws and burner assembly in a secure
location for later reinstallation.
Air Shutter Rod
Figure 5 - Releasing the air shutter adjustment rod
Figure 6 - Accessing the control compartment
2. Remove the control compartment access door and gasket by
removing the twelve (12) screws securing it. Set aside the
screws, door, and gasket for later reinstallation (Figure 6).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
4*For PF2 System, see Page 5 and Figure 12.
Control Compartment
Access Panel and
Gasket
Right Burner Bracket
Orifi ce
Slot
Figure 7 - Accessing the control compartment
3. Loosen the front left screw of the right burner bracket. Remove
the other three screws, and rotate the bracket clockwise to
uncover the slot in the fi rebox fl oor (Figure 7).
Connect wiring harnesses for blower and optional
rebox panel backlight kit - PF1 System*
NOTE: Use only original, factory-supplied wiring inside fi replace.
1. In the control compartment, use a screwdriver or other
blunt object to carefully break the sealant around the wires.
NOTE: Be careful not to damage the wires.
2. Plug the multiwire harness (provided with the fi rebox panel
backlight kit) into the SimFlame™ (fl icker) module port with
the red wires (Figure 8).
NOTE: If not installing the SimFlame module, plug the
multiwire harness directly into the power harness (omit the
components outlined in Figure 8) and skip step 3.
Multiwire Harness from
Panel Backlighting Kit
SimFlame
Module (Plug into
AUX OUT
on Control
Module)
Power
Harness
If not using SimFlame
(flicker) module, omit
outlined components.
Figure 8 - Connecting multiwire harness and fl icker module
3. Plug the power harness (provided with the fi rebox panel
backlight kit) into the SimFlame Module port with the black
and white wires (Figure 9).
FAN AUX
OUT
SimFlame
Slot
SimFlame
Module
Fan Control
Module
Plug blower
into FAN port Plug lights into
AUX OUT port
Figure 9 - Connecting the lights and blower
4. Route the lighting wiring up through the access opening, and
slide it into the slot (Figure 9).
5. Plug the power plug end of the power harness into the AUX
OUT port on the fi replace fan control module (Figure 9).
Install refl ector (from optional fi rebox panel backlight kit)
1. Insert the bottom edge of the refl ector (provided with the
rebox backlight kit) into the fi replace fi rst. Then, push the
top edge into rear of fi replace (Figure 10).
NOTE: Lift the refl ector over the tabs on the rear ledge of the
replace
2. Align the large hole in the lower face of the refl ector over the
screw in the fi rebox rear wall.
3. Align the screw holes in the top and bottom edges of refl ector
with the rear most holes in the fi replace ceiling and rear ledge.
Secure the refl ector using six (6) #10-16 x 3/8 hex-head sheet
metal screws provided with the fi rebox panel backlight kit.
~
Refl ector
Fireplace
Front
Tab
Rear Ledge
Figure 10 - Installing the refl ector
Install side panels (from required fi rebox panel kit)
1. Align the screw hole in the top fl ange of the side panel with
the upper hole in the inside wall of the fi replace (Figure 11).
2. Align the screw holes in the bottom fl anges of the side
panel with the holes in the front and rear ledges.
3. Secure each panel with three (3) #10-16 x 3/8 hex-head
sheet metal screws provided with the fi rebox panel kit.
Left Side
Panel
Right
Side
Panel
~
Left Side
Panel
Front
Ledge
Rear
Ledge
~
Figure 11 - Installing the side panels
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
5
CONNECTION AND ROUTE WIRING FOR OPTIONAL PANEL
BACKLIGHT KIT - SIT PROFLAME II SYSTEM
1. After accessing the control compartment (see Page 3, Figure
6), use a screwdriver or similar object to carefully break the
sealant around the wires, taking care not to nick the wires.
2. Plug in the Multi-wire Harness (provided with the Panel
Backlight Kit) into the SimFlame module port with the red
wires (Figures 8 and 12) and the light wire harness into the
light module harness.
3. Plug in the light wire harness (provided with the Panel
Backlight Kit) into the SimFlame Module port with the black
and white wires.
NOTE: If NOT installing the SimFlame (fl icker) Module,
plug the Multi-Wire Harness directly into the light wire
harness (omitting the components outlined in Figure 8)
4. Route the wiring up through the access opening and slide it
into the slot (Figure 14).
5. Attach the wiring to each lamp assembly as described
below and shown in Figure 17:
a. Route one set of three leads (white/green/black)
through the hole in the front of the bracket.
b. Connect the green wire as shown in Figure 17.
c. Insert the lamp (with green wire attached) into the
bracket until the spring clip is engaged.
d. Attach the white (neutral) and black (hot) wires as
shown in Figure 17.
6. Carefully lay the Panel Backlight lamp assemblies and
wiring on the fi replace fl oor. The lamp assemblies will not
be installed until the back panel is installed (In Step 9,
Figure 18 on Page 6).
Figure 12 - Connecting the SIT PF II Module
Light Wire Harness
Light Module Harness
PF2 Module
SimFlame Module
Multi-Wire Harness
Red Wires
Install back panel
1. Insert the bottom edge of the back panel into the fi replace
rst, then position it in front of the previously installed
refl ector (Figure 13).
NOTE: Lift the back panel over the tabs on the rear ledge of
the fi replace.
2. Align the screw holes in the top and bottom edges of the
back panel with the holes in the fi replace ceiling and rear
ledge. Secure using seven (7) #10-16 x 3/8 hex-head sheet
metal screws provided with the fi rebox panel kit.
~
Fireplace
Front
Left Side
Panel
Back Panel
Refl ector
Tab
Rear Ledge
Figure 13 - Installing the back panel
Route wiring for optional blower kit
NOTE: Use only original, factory-supplied wiring inside the
replace. See the wiring diagrams on Page 11.
1. Route the wiring per the instructions (P/N 750028M).
Route wiring for optional power vent kit
NOTE: Use only original, factory-supplied wiring inside the
replace. See the wiring diagrams on Page 11.
1. Route the wiring per instructions (P/N 506022-01).
Determine optional fi rebox panel backlight kit wire
routing method
There are two approved methods for routing the wiring for the
optional fi rebox panel backlight kit.
The preferred method is outlined in the following sections. The
alternate method is included for installations where the fi rebox
rear ledge does not have backlight wire routing holes, and is
described in the Appendix section Route and connect optional
rebox panel backlight kit wiring and install lamp assemblies
as shown on Page 6.
1. Determine whether the fi rebox rear ledge has backlight wire
routing holes (Figure 14).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
6
Backlight Wire
Routing Holes
Figure 14 - Routing wiring
2. If the fi rebox rear ledge has backlight wire routing
holes, proceed with the instructions in Route and
connect optional fi rebox panel backlight kit wiring
and install lamp assemblies below.
If the rear ledge does not have backlight wire
mounting holes, follow the instructions detailed in
Route and connect optional fi rebox panel backlight
kit wiring and install lamp assemblies as shown on
this page.
Route and connect optional fi rebox panel backlight kit
wiring and install lamp assemblies
1. Remove the three (3) cover plates in the lower front face
of the back panel. Discard the cover plates, but retain the
screws.
Figure 15 - Removing the cover plates, and routing the wiring
2. Route one set of three leads (white/green/black) through each
backlight wire routing hole in the rear ledge (Figure 14).
3. Route one set of three leads (white/green/black) through each
hole in the lower front face of the back panel (Figure 15).
4. With one set of three leads, connect the green wire to a
lamp (Figure 16).
5. Insert the lamp (with green wire attached) into a bracket
until the spring clip is engaged (Figure 16).
6. Connect the white (neutral) wire and black (hot) wire
(Figure 17).
Figure 16 - Attaching green wire to fi rebox panel backlight
kit lamp, and inserting lamp into bracket
Figure 17 - Attaching black and white wires to fi rebox
panel backlight kit lamp
7. Repeat the process in step 4 through step 6 for the
two remaining lamp assemblies.
8. Insert the three (3) lamp assemblies in the exact
orientation shown (Figure 18).
Figure 18 - Installing the lamp assemblies
9. Secure the lamp assemblies using the six (6) previously
removed screws from the cover plates (Figure 18).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
7
Door gasket instructions
1. Reinstall the door. If the door does not fully close easily,
the door gasket will need to be dressed. See Figure 21 and
Warning below.
Correctly dressed Gasket.
Screwdriver works well
to dress gasket.
WARNING
The door should easily close without needing to
be pressed down. If it has to be pressed down to
close, the gasket in the top of the door should be
dressed so it lays on the glass.
Correctly Dressed Gasket Improperly Dressed Gasket
Improperly dressed gasket.
No gap between gasket
door channel.
Clean porcelain panels (if applicable)
1. If applicable, use non-ammoniated glass cleaner and a soft
rag to remove fi ngerprints and smudges from porcelain
panels and fl oors.
Install glass door assembly
1. Hold the glass door assembly by the sides, and hook the
top edge to the fi replace. Then swing the bottom edge in
toward the fi replace (Figure 20).
NOTE: Be careful not to damage the glass.
2. Align the screw holes below the door assembly with the
holes in the fi replace, and secure using the (3) provided
screws.
Install baffl e (provided with fi replace)
1. With the baffl e oriented as shown (Figure 19), slide the rear
tabs into the slots in the back panel.
2. While sliding the tabs into the slots, engage the front lip of
the baffl e under the spring clips in the fi rebox ceiling.
Baffl e
Slots in
Back Panel
Spring Clip Firebox Ceiling
Tabs
Figure 19 - Installing the baffl e
Figure 20 - Installing the glass door assembly
Figure 21 - Door gasket
Rating plate and lighting instructions
are attached to door bracket.
Glass Door Assembly
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
8
Gather and reseal all wiring
1. Gather all wiring and pilot connections together at the end
of the slot, and reseal with high-temperature sealant, such
as Mill-Pac® (not provided) (Figure 7).
2. Reposition the right burner bracket and secure with the
three (3) previously removed screws; tighten the fourth
screw (Figure 7).
3. Replace the control compartment access door and gasket,
and secure with the twelve (12) previously removed screws
(Figure 7).
4. Carefully slide the burner assembly venturi onto the orifi ce.
While placing the burner assembly onto the brackets,
reinstall the air shutter adjustment lever (Figure 5). Secure
the burner assembly with the two (2) previously removed
screws.
Install rear fl oor section (from required fl oor kit)
1. Place lower back edge of rear fl oor section on rear ledge of
replace, behind the tabs (Figure 22).
2. Align outermost front hole on either side of rear fl oor
section with hole in center lower tab in each side panel. Pull
rear fl oor section forward until it butts against the burner,
and secure using fi ve (5) #10-16 x 3/8 hex-head sheet
metal screws provided with the fl oor kit.
Rear
Floor
Section
Rear
Ledge
Tab
~
Side Panel
(Center Lower Tab)
Figure 22 - Installing the rear fl oor section
Install front fl oor section (from required fl oor kit)
1. Engage the lower front lip of the front fl oor section under
the locking clips attached to the fi replace front ledge, and
then slide it back (Figure 23).
2. Align the notches in the back edge of the front fl oor section over
the holes in the rear fl oor section. Push the front fl oor section
backward until it butts against the burner, and screw the front
oor section as shown in Figure 23.
Locking Clip
Front
Ledge
Notch
Rear
Floor
Section
Front
Floor
Section
Lip
Figure 23 - Installing the front fl oor section
Install media (from optional media kit)
WARNING
Handle media only when cool. Turn OFF all electricity
to the appliance before installing media. Media gets
very HOT during fi replace use and will remain hot up
to ONE HOUR after the gas supply is turned off.
Any attempt to use media not specifi ed for your fi replace
confi guration will result in incomplete combustion,
sooting, and poor fl ame quality, and will void the
warranty.
Do NOT mound up media, especially on the burner.
If using multiple colors of media, NEVER use more
than fi ve (5) pounds total (approximately) at one time.
Do NOT allow media to get into the pilot hole.
1. If installing a fl oor kit that requires media, place an even
layer of media in the recessed area around the burner (see
bold outlined area in Figure 24; also refer to Figure 1).
Figure 24 - Placement of media
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
9
Install optional surround
1. Remove clean face trim and install brackets - Remove
the clean face frame shown in Figure 27. Attach surround
mounting brackets to unit (10 screws). See Figure 25.
Surround will be mounted to these brackets (see Figure 26).
2. Attach the surround and secure it using the nine (9) screws
provided with the surround kit (Figure 26).
Finishing with optional Surround and Bezel
1. With unit in framing, secure nailing fl anges to the wall framing.
2. Retrieve and secure heat shield to top front of unit with two
screws.
3. Remove the clean face frame (see Figure 27).
4. Place insulation fl at across the top of the fi replace lengthwise
behind heat shield.
5. Install top, bottom and two (2) side surround support pieces
with screws from step 1 (see Figure 27).
6. Cut top noncombustible fi reboard to size and install fl ush with
top frame pieces (side noncombustible boards not used).
7. Install glass media.
8. Remove top, bottom and two side trim pieces of barrier as-
sembly. Insert remaining barrier assembly into bezel assem-
bly and attach with screws.
9. Reinstall the door.
10. Attach surround to surround support with six (6) screws.
11. Hang barrier assembly on door and snap underneath door.
Surround mounting
brackets (provided
with surround kit)
Clean
Face Frame
(removed first)
Bezel and Barrier
(added after Surround
- not shown)
One (1) Top non
-combustible
board
Clean
Face Frame
(removed first)
Figure 25 - Surround Mounting Brackets
Figure 26 - Installing optional surround
Figure 27 - Remove clean face trim and install brackets
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
10
6 Secure Barrier screen to Bezel assembly with screws
removed in step 2.
7 Install barrier/bezel assembly onto glass door.
4. Hook the bezel upper fl ange to the top edge of the glass
door assembly, and then swing the lower edge of the bezel
toward the door (Figure 29).
5. Gently push the lower edge of the bezel to attach the bezel
lower fl ange to the lower edge of the glass door frame.
[CROSS-SECTION]
Barrier
Flanges
Door Trim
Barrier
Figure 28 - Place barrier screen on Bezel assembly
Figure 29 - Barrier assembly
Figure 30 - Secure Barrier screen to Bezel assembly
Installing Barrier into Bezel
NOTE: See Barrier Removal Instructions on Page 3, if
applicable.
1. Remove barrier assembly that is shipped with unit.
2 Remove barrier screen from assembly by removing 3
screws top and bottom and one on each side.
3 Place barrier screen on Bezel assembly. See Figure 28.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
11
CAUTION
Ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box. Failure to
do so will result in a potential safety hazard. The appliance must be electrically grounded in accordance with local codes, or
in the absence of local codes, the National Electrical Code, ANSI/NFPA 70, latest edition (in Canada, the current CSA C22.1
Canadian Electrical Code).
Red
Green
Ground
Screw
Black
Hot Side of
Receptacle
Tab Cut
Tab Intact
Green White
Neutral Side of
Receptacle
120 VAC—Black
Neutral—White
Ground—Green
J-BOX / RECEPTACLE
WIRING
120V, 60HZ, 1PH
Junction Box
Field Wired
Factory Wired
(Power Supply
Unswitched)
Figure 31 - Junction Box Wiring
Pilot Tube
COLOR CODE:
B = BLACK
BB = BROWN W/BLACK STRIPE
BG = BROWN W/GREEN STRIPE
BL = BLUE
BR = BROWN
G = GREEN
GY = GRAY
O = ORANGE
R = RED
W = WHITE
Y = YELLOW
Spark Electrode
Flame Sensor
IPI Pilot
885 Valve Optional
Split Flow
BL
W
Y
Y
BR
G
O
O
R
R
B
B
GY
GY
R
B
BL
W
B
BB
B
BR
BB
BG
W
W
G
Battery Holder w/Switch
ON/ Remote
/OFF
Battery Holder
Wire Harness
Reset Switch
“see instructions”
Optional Variable Light
Power Vent Blower
Power Vent
Models Only
Optional Circulation
Blower
Air Pressure Switch
Power Vent Only
Models w/o pressure switch have
these connectors plugged together
Main Wire
Harness
Main Power Cord
Control Module
G
B
G
W
B
Fuse
BG
BG
ELECTRONIC WIRING DIAGRAM
Ground Y
B
Schematic Representation Only
Battery Holder w/Switch
ON/Remote/Off
Figure 32 - Gas Valve Electronic Wiring Diagram - SIT ProFlame II
INNOVATIVE HEARTH PRODUCTS • LINEAR GAS FIREPLACES • REQUIRED AND OPTIONAL ACCESSORIES
12
Printed in U.S.A. © 2014 Innovative Hearth Products
P/N 900077-05 Rev. A 09/2016 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210
IHP reserves the right to make changes at any time, without notice, in design, materials,
specifi cations, prices and also to discontinue colors, styles, and products. Consult your local
distributor for fi replace code information.
APPENDIX: ALTERNATE INSTALLATION INSTRUCTIONS
Route and connect optional fi rebox panel backlight kit
wiring and install lamp assemblies
NOTE: These instructions should be used in place of Route and
connect optional fi rebox panel backlight kit wiring and install
lamp assemblies on Page 6, for fi replaces without backlight
wiring kit routing holes as shown in Figure 14 on Page 6.
1. Route one set of three leads (white/green/black) through
the hole in the front of the bracket (Figure 33).
Front of Mounting Bracket
Figure 33 - Routing wires through lamp bracket
2. Connect the green wire to the lamp (Figure 34).
3. Insert the lamp (with green wire attached) into bracket until
the spring clip is engaged (Figure 34).
4. Connect the white (neutral) wire, and black (hot) wire
(Figure 35).
Figure 34 - Attaching green wire to fi rebox panel backlight
kit lamp, and inserting lamp into lamp bracket
Figure 35 - Attaching black and white wires to fi rebox
panel backlight kit lamp
5. Repeat the process in step 1 through step 4 for the two
remaining lamp assemblies.
6. Carefully lay the fi rebox backlight lamp assemblies and
wiring on the fi replace fl oor. The lamp assemblies will not
be installed until the back panel is installed (in a later step).
7. Remove the three (3) cover plates in the lower front face
of the back panel. Discard the cover plates, but retain the
screws.
8. Insert the three (3) previously assembled lamp assemblies
in the orientation shown (Figure 36).
NOTE: The wires will be routed under the rear fl oor section
in the next step.
9. Secure the lamp assemblies using the six (6) previously
removed screws from the cover plates.
Cover Plate
Note orientation of each
lamp assembly.
Figure 36 - Installing the lamp assemblies
NOTE: When installing the rear fl oor, route the fi rebox
backlight wiring through the notches under the rear fl oor
section. Be careful not to pinch or damage the wires.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Astria Fireplaces Rhapsody Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI