Axis A1001 User manual

Category
Security door controllers
Type
User manual
AXISA1001NetworkDoorController&AXISEntryManager
UserManual
AboutthisDocument
Thismanualisintendedforadministratorsandusersof
AXISA1001NetworkDoorControllerandisapplicableto
AXISEntryManagerandrmware1.25andlater.Itincludes
instructionsforusingandmanagingtheproductonyournetwork.
Previousexperienceofnetworkingwillbeofusewhenusingthis
product.SomeknowledgeofUNIXorLinux-basedsystemsmayalsobe
benecial,fordevelopingshellscriptsandapplications.Laterversions
ofthisdocumentwillbepostedtotheAxiswebsite,asrequired.See
alsotheproduct’sonlinehelp,availableviatheweb-basedinterface.
Inthismanual,AXISA1001NetworkDoorControllerisreferredtoas:
theAxisproduct,product,networkdoorcontroller,anddoorcontroller.
Liability
Everycarehasbeentakeninthepreparationofthisdocument.Please
informyourlocalAxisofceofanyinaccuraciesoromissions.Axis
CommunicationsABcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomakechangestothe
productandmanualswithoutpriornotice.AxisCommunicationsAB
makesnowarrantyofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,theimplied
warrantiesofmerchantabilityandtnessforaparticularpurpose.Axis
CommunicationsABshallnotbeliablenorresponsibleforincidentalor
consequentialdamagesinconnectionwiththefurnishing,performance
oruseofthismaterial.Thisproductisonlytobeusedforitsintended
purpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingtotechnologyembodied
intheproductdescribedinthisdocument.Inparticular,andwithout
limitation,theseintellectualpropertyrightsmayincludeoneormore
ofthepatentslistedatwww.axis.com/patent.htmandoneormore
additionalpatentsorpendingpatentapplicationsintheUSandother
countries.
ThisproductcontainssourcecodecopyrightAppleComputer,
Inc.,underthetermsofApplePublicSourceLicense2.0(see
www.opensource.apple.com/apsl).Thesourcecodeisavailablefrom
https://developer.apple.com/bonjour/
EquipmentModications
Thisequipmentmustbeinstalledandusedinstrictaccordancewiththe
instructionsgivenintheuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorizedequipmentchangesor
modicationswillinvalidateallapplicableregulatorycertications
andapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIXare
registeredtrademarksortrademarkapplicationsofAxisABinvarious
jurisdictions.Allothercompanynamesandproductsaretrademarksor
registeredtrademarksoftheirrespectivecompanies.
AssaandAperioaretrademarksorregisteredtrademarksofASSA
ABLOYAB.
NetworkTimeProtocolVersion4DistributioniscopyrightofUniversity
ofDelaware©UniversityofDelaware1992–2011.Thefollowing
copyrightnoticeappliestoalllescollectivelycalledtheNetworkTime
ProtocolVersion4Distribution.Unlessspecicallydeclaredotherwise
inanindividualle,thisnoticeappliesasifthetextwasexplicitly
includedinthele.Permissiontouse,copy,modify,anddistributethis
softwareanditsdocumentationforanypurposewithorwithoutfeeis
herebygranted,providedthattheabovecopyrightnoticeappearsinall
copiesandthatboththecopyrightnoticeandthispermissionnotice
appearinsupportingdocumentation,andthatthenameUniversityof
Delawarenotbeusedinadvertisingorpertainingtodistributionofthe
softwarewithoutspecic,writtenpriorpermission.TheUniversityof
Delawaremakesnorepresentationsaboutthesuitabilitythissoftware
foranypurpose.Itisprovided"asis"withoutexpressorimplied
warranty.
RegulatoryInformation
Europe
ThisproductcomplieswiththeapplicableCEmarkingdirectives
andharmonizedstandards:
ElectromagneticCompatibility(EMC)Directive2004/108/EC.See
ElectromagneticCompatibility(EMC)onpage2.
LowVoltage(LVD)Directive2006/95/EC.SeeSafetyonpage3.
RestrictionsofHazardousSubstances(RoHS)Directive2011/65/EU.
SeeDisposalandRecyclingonpage3.
Acopyoftheoriginaldeclarationofconformitymaybeobtainedfrom
AxisCommunicationsAB.SeeContactInformationonpage3.
ElectromagneticCompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulllapplicable
standardsfor:
Radiofrequencyemissionwheninstalledaccordingtothe
instructionsandusedinitsintendedenvironment.
Immunitytoelectricalandelectromagneticphenomenawhen
installedaccordingtotheinstructionsandusedinitsintended
environment.
USA
Thisequipmenthasbeentestedusingashieldednetworkcable(STP)
andfoundtocomplywiththelimitsforaClassBdigitaldevice,
pursuanttopart15oftheFCCRules.Theselimitsaredesigned
toprovidereasonableprotectionagainstharmfulinterferenceina
residentialinstallation.Thisequipmentgenerates,usesandcanradiate
radiofrequencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterference
willnotoccurinaparticularinstallation.Ifthisequipmentdoes
causeharmfulinterferencetoradioortelevisionreception,which
canbedeterminedbyturningtheequipmentoffandon,theuseris
encouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichthereceiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Theproductshallbeconnectedusingashieldednetworkcable(STP)
thatisproperlygrounded.
Canada
ThisdigitalapparatuscomplieswithCANICES-3(ClassB).Theproduct
shallbeconnectedusingashieldednetworkcable(STP)thatisproperly
grounded.
CetappareilnumériqueestconformeàlanormeCANNMB-3(classeB).
Leproduitdoitêtreconnectéàl'aided'uncâbleréseaublindé(STP)qui
estcorrectementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRFemission
accordingtotheClassBlimitofEN55022.Theproductshallbe
connectedusingashieldednetworkcable(STP)thatisproperly
grounded.
Thisproductfulllstherequirementsforimmunityaccording
toEN61000-6-1residential,commercialandlight-industrial
environments.
Thisproductfulllstherequirementsforimmunityaccordingto
EN61000-6-2industrialenvironments.
Thisproductfulllstherequirementsforimmunityaccordingto
EN55024ofceandcommercialenvironments
Thisproductfulllstherequirementsforimmunityaccordingto
EN50130-4residential,commercial,light-industrialandindustrial
environments.
Australia/NewZealand
ThisdigitalequipmentfulllstherequirementsforRFemission
accordingtotheClassBlimitofAS/NZSCISPR22.Theproductshall
beconnectedusingashieldednetworkcable(STP)thatisproperly
grounded.
Japan
B情報
で使的と
やテ使用
を引取扱
取りは、
(STP)を使してしてさい
切に地しださ
Safety
ThisproductcomplieswithIEC/EN60950-1,SafetyofInformation
TechnologyEquipment.Ifitsconnectingcablesareroutedoutdoors,
theproductshallbegroundedeitherthroughashieldednetworkcable
(STP)orotherappropriatemethod.
Thepowersupplyusedwiththisproductshallfullltherequirements
forSafetyExtraLowVoltage(SELV)andLimitedPowerSource(LPS)
accordingtoIEC/EN/UL60950-1.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife,disposeof
itaccordingtolocallawsandregulations.Forinformationabout
yournearestdesignatedcollectionpoint,contactyourlocalauthority
responsibleforwastedisposal.Inaccordancewithlocallegislation,
penaltiesmaybeapplicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbedisposedof
togetherwithhouseholdorcommercialwaste.Directive2012/19/EU
onwasteelectricalandelectronicequipment(WEEE)isapplicablein
theEuropeanUnionmemberstates.Topreventpotentialharmto
humanhealthandtheenvironment,theproductmustbedisposed
ofinanapprovedandenvironmentallysaferecyclingprocess.For
informationaboutyournearestdesignatedcollectionpoint,contact
yourlocalauthorityresponsibleforwastedisposal.Businessesshould
contacttheproductsupplierforinformationabouthowtodispose
ofthisproductcorrectly.
ThisproductcomplieswiththerequirementsofDirective2011/65/EUon
therestrictionoftheuseofcertainhazardoussubstancesinelectrical
andelectronicequipment(RoHS).
China
Thisproductcomplieswiththerequirementsofthelegislative
actAdministrationontheControlofPollutionCausedbyElectronic
InformationProducts(ACPEIP).
ContactInformation
AxisCommunicationsAB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
www.axis.com
SupportedReaders
Thislistofsupportedreadersissubjecttochangewithoutnotice.
ContactyourAxisresellerforinformationaboutsupportedreaders.
ThisproductiscompatiblewithULListedWiegandaccesscontrol
readers
ThisproductiscompatiblewiththefollowingRS485accesscontrol
readers:
AXISA4011-EReader
HIDiCLASS®RW100:6101CG40000,6101CGM0000,6101CK40000,
6101CK40002,6101CK40100,6101CK403C0,6101CKM0000,
6101CKM0002,6101CKM0203;RW300:6111CG40000,61 1 1CG400C0,
6111CGM0000,61 11CK40000,61 11CK4000Z,6111CKM0000;
RW400:6121CG40000,6121CGM0000,6121CK40000,
6121CK40003,6121CK40007-G3.0,6121CK4000D-G3.0,
6121CKM0000;R40:6122CKP00P0,6122CKP05P0,6122CKP06P0;
RWK400:6131CG4020000,6131CK4000000,6131CK4000014,
6131CK4000300,6131CK4020000,6131CKM000000,
6131CKM000214;RK40:6132BKP00Q709-G3.0,6132CKP000009,
6132CKP000011,6132CKP000700-G3.0,6132CKP000709-G3.0,
6132CKP001009,6132CKP001011,6132CKP00P000,6132CKP00P009,
6132CKP00P709-G3.0,6132CKP00Q709-G3.0,6132CKP030014,
6132CKP060514,6132CKP06P009,6132CKP06P609,6132CKP070209;
RW150:6141CG40000,6141CGM0000,6141CK40000,6141CKM0000;
R15:6142CKP000Z,6142CKP00P0,6142CKP0100;RWKL550:
6171BK4000000,6171BK4000009,6171BK4000014,6171BK4000214,
6171BK4000500,6171BK4040Z14,6171BK4060000,6171BK4060209,
6171BK4060Z09,6171BK4061000,6171BKM000000,6171BKM000200,
6171BKM000300,6171BKM040400;RWKLB575:6181BK4000000,
6181BK4000009,6181BK4000014,6181BK4000022,6181BK406C009;
HIDSmartid®:8031DSAP
HIDpivClass®R10-H:900LHRNAK00000,900LHRTAK00000,
900NHRNAK00000,900NHRTAK00000,900PHRNAK00000,
900PHRTAK00000,910LHRNAK00000,910LHRTAK00000,
910NHRNAK00000,910NHRTAK00000,910PHRNAK00000,
910PHRTAK00000,920LHRNAK00000,920LHRTAK00000,
920NHRNAK00000,920NHRTAK00000,920PHRNAK00000,
920PHRTAK00000,921LHRNAK00000,921LHRTAK00000,
921NHRNAK00000,921NHRTAK00000,921PHRNAK00000,
921PHRTAK00000;RPKCL40-P:923LPRNAK00000,923LPRTAK00000,
923NPRTAK00000,923PPRNAK00000,923PPRTAK00000
Aptiq
TM
:M11,MTK15,MTMSK15,MT15,MTMS15
ForinformationaboutwhichcompatibleRS485accesscontrolreaders
havebeenveriedbyUL,seetheInstallationGuideavailableat
www.axis.com
RequirementsforCompliancewithUL2946thEdition
ThissectioncontainsinformationandinstructionsrequiredforUL
compliance.TomakesuretheinstallationisULcompliant,follow
theinstructionsbelowinadditiontothegeneralinformationand
instructionsprovidedthroughoutthisdocument.Incaseswhere
piecesofinformationcontradicteachother,therequirementsforUL
compliancealwaysreplacegeneralinformationandinstructions.
SupportedReaders
CompatibilitywiththefollowingRS485readershasbeenveried
byUL:HIDiClassRK40,HIDSmartID8031DSHM,andAptiqQ
MTMSK15.
TheAxisproductshallbeinstalledandservicedbyafactorytrained
professional.
TheAxisproductshallbeinstalledwithintheprotectedpremises
(securedarea).
TheAxisproductshallbemountedindoors.Outdoorusehasnot
beenevaluatedorapprovedbyUL.
AllinterconnectingdevicesshallbeULListedandClass2
low-voltagepowerlimited.
AllwiringmethodsshallbeperformedinaccordancewithNFPA70,
localcodesandauthoritieshavingjurisdiction.
WhentheAxisproducthasreachedtheendofitsusefullife,
disposeofitaccordingtolocallawsandregulations.Theproduct
shouldnotbedisposedoftogetherwithhouseholdorcommercial
waste.SeeDisposalandRecyclingonpage3.
-The3.0VlithiumbatteryusedbytheAxis
productisaULRecognizedcomponent.
(Type:BR2032,diameter:20mm(0.78in),
manufacturers:Rayovac,Panasonic).The
followingbatterytypeisalsoaULRecognized
component:TypeCR2032,manufacturers:Fuji,
Maxell,Renata,Varta,Panasonic,JHIH
-Usersshallnotreplacethebattery.Ifthe
batteryneedsreplacing,afactorytrained
serviceprofessionalshallcontactAxissupport
atwww.axis.com/techsupforassistance.
-Usedbatteriesshallbedisposedofaccording
tolocallawsandregulations,whichmayvary
fromstatetostate.WasteBR/CRlithiumcells
areneitherlistednorexemptedfromtheUSEPA
hazardouswasteregulations.Wastelithium
batteriescanbeconsideredreactivehazardous
wasteifthereisasignicantamountof
unreacted,orunconsumedlithiumremaining.
Forinformationabouthowtodisposeofused
lithiumbatteries,contactyourlocalauthority
forwastedisposal.
-Temperatures0°Cto50°C(32°Fto122°F).
-ULListedorR/CAWMwiresthathavean
conductorgaugerangeofAWG22–14shallbe
used.
-Theminimumconductorgaugeforconnection
betweenthepowersourcingequipment(PSE)
orpowerinjectorandthepowereddevice(PD)
is26AWG.
Connectors
-Thisproductisnotintendedforoutsidewiring
ascoveredbyArticle800intheNational
ElectricalCode,NFPA70.
-PowerConnectorForULsecurityapplications,
theproductshallbepoweredbyaUL294Listed
orUL603ListedClass2low-voltagepower
limitedpowersupplythatiscapableof4hours
ofstandbypower.
-NetworkConnectorPoweroverEthernet
(PoE)shallbesuppliedbyaUL294Listed
Class2powerlimitedinjectorthatprovides
44–57VDC,15.4Wand4hoursofstandby
power.CompliancewithIEEE802.3(atoraf)
specicationshasnotbeenveriedaspartof
UL294/B
.
-TamperingAlarmPinHeaderTocomplywith
UL294/7.2.1(Enclosure),thetamperingalarm
shallbeconnectedtoasoundalarm.
-TheAxisproduct,whetheritisastandalone
doorcontrollerorasystemofdoorcontrollers,
shallnotimpairtheintendedoperationofthe
panichardwareusedinconjunctionwithit.
-IfusingajunctionboxtomounttheAxis
product,thejunctionboxshallbeULListed.
-ThefunctionalityofAXISCameraManagement,
see,hasnotbeenevaluatedbyUL.
MaintenanceInstructions
-Formaintenanceinstructions(somesteps
requireaccesstotheproduct’swebpages),
seepage25.Forinformationabouthowto
conguretheAxisproductusingtheproduct’s
webpages(AXISEntryManager),seetheUser
Manual.
-Firmwareversion:DoorController,Model
A10011.20.2
Support
Shouldyourequireanytechnicalassistance,pleasecontactyourAxis
reseller.Ifyourquestionscannotbeansweredimmediately,your
resellerwillforwardyourqueriesthroughtheappropriatechannelsto
ensurearapidresponse.IfyouareconnectedtotheInternet,youcan:
downloaduserdocumentationandsoftwareupdates
ndanswerstoresolvedproblemsintheFAQdatabase.Search
byproduct,category,orphrase
reportproblemstoAxissupportstaffbyloggingintoyourprivate
supportarea
chatwithAxissupportstaff
visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/forusefultrainings,
webinars,tutorialsandguides.
AXISA1001NetworkDoorController&AXISEntryManager
TableofContents
SafetyInformation..........................................6
HazardLevels...................................................6
OtherMessageLevels............................................6
HardwareOverview..........................................7
LEDIndicators..................................................9
ConnectorsandButtons..........................................1
0
AccesstheProduct..........................................12
AccessfromaBrowser...........................................12
AccessfromtheInternet..........................................12
SettheRootPassword...........................................12
TheOverviewPage..............................................13
SystemConguration........................................14
CongurationStepbyStep......................................14
SelectaLanguage...............................................14
ConguretheHardware..........................................15
VerifytheHardwareConnections...................................19
SettheDateandTime............................................20
ConguretheNetworkSettings....................................21
CongureCardFormats..........................................21
ManageNetworkDoorControllers..................................23
MaintenanceInstructions.........................................25
AccessManagement.........................................26
AboutUsers....................................................26
TheAccessManagementPage.....................................26
ChooseaWorkow..............................................26
CreateandEditAccessSchedules..................................27
CreateandEditGroups...........................................29
ManageDoors..................................................29
CreateandEditUsers............................................31
ExampleAccessScheduleCombinations.............................33
AlarmandEventConguration................................35
ViewtheEventLog..............................................35
ViewtheAlarmLog..............................................35
ConguretheEventandAlarmLogs................................35
SetUpActionRules.............................................36
ReaderFeedback................................................41
Reports...................................................42
View,Print,andExportReports....................................42
SystemOptions.............................................43
Security.......................................................43
Date&Time....................................................45
Network.......................................................45
Ports&Devices.................................................50
Maintenance...................................................50
Support.......................................................51
Advanced......................................................52
ResettoFactoryDefaultSettings...................................52
Troubleshooting............................................53
ChecktheFirmware.............................................53
UpgradetheFirmware...........................................53
EmergencyRecoveryProcedure....................................53
Symptoms,PossibleCausesandRemedialActions.....................54
TechnicalSpecications......................................56
AXISA1001NetworkDoorController................................56
AXISEntryManager.............................................58
Connectors....................................................59
ConnectionDiagrams............................................63
5
AXISA1001NetworkDoorController&AXISEntryManager
SafetyInformation
SafetyInformation
HazardLevels
DANGER
Indicatesahazardoussituationwhich,ifnotavoided,willresultindeathorseriousinjury.
WARNING
Indicatesahazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderate
injury.
NO NO
NO
TICE TICE
TICE
Indicatesasituationwhich,ifnotavoided,couldresultindamagetoproperty.
OtherMessageLevels
ImportantIndicatessignicantinformationwhichisessentialfortheproducttofunctioncorrectly.
NoteIndicatesusefulinformationwhichhelpsingettingthemostoutoftheproduct.
6
AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
HardwareOverview
Thehardwareoverviewisdividedintothefollowingcategories:
Frontandback.Seepage7.
I/Ointerface.Seepage8.
Externalpowerinputs.Seepage8.
Poweroutputs.Seepage8.
LEDindicators,buttonsandotherhardware.Seepage9.
1
2
5
4
8
6
7
3
Frontandback:
1
Cover
2
Coverscrew
3
Coverremovalslot
4
Base
5
DINclipupper
6
Tamperingalarmswitchback
7
DINcliplower
8
Partnumber(P/N)&Serialnumber(S/N)
7
AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
1
2
3
4
5
6
7
8
9
10
11
12
I/Ointerface:
1
Readerdataconnector(READERDATA1)
10
Readerdataconnector(READERDATA2)
3
ReaderI/Oconnector(READERI/O1)
8
ReaderI/Oconnector(READERI/O2)
4
Doorconnector(DOORIN1)
7
Doorconnector(DOORIN2)
6
Auxiliaryconnector(AUX)
5
Audioconnector(AUDIO)(notused)
Externalpowerinputs:
2
Powerconnector(DCIN)
12
Networkconnector(PoE)
Poweroutputs:
9
Powerlockconnector(LOCK)
11
Power&Relayconnector(PWR,RELAY)
8
AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
1
2
3
4
5
6
7
8
9
1011
12
13
LEDindicators,buttonsandotherhardware:
1
PowerLEDindicator
2
StatusLEDindicator
3
NetworkLEDindicator
4
Reader2LEDindicator(notused)
5
Reader1LEDindicator(notused)
6
Tamperingalarmpinheaderfront(TF)
7
Tamperingalarmpinheaderback(TB)
8
LockLEDindicator
9
LockLEDindicator
10
Tamperingalarmsensorfront
11
SDcardslot(microSDHC)(notused)
12
Controlbutton
13
Partnumber(P/N)&Serialnumber(S/N)
LEDIndicators
LED
Color
Indication
Green
Steadyforconnectiontoa100MBit/snetwork.Flashesfornetworkactivity.
Amber
Steadyforconnectiontoa10MBit/snetwork.Flashesfornetworkactivity.
Network
UnlitNonetworkconnection.
GreenSteadygreenfornormaloperation.
Amber
Steadyduringstartupandwhenrestoringsettings.
Status
Red
Slowashforfailedupgrade.
Green
Normaloperation.
Power
Amber
Flashesgreen/amberduringrmwareupgrade.
9
AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
GreenSteadywhennotenergized.
Red
Steadywhenenergized.
Lock
UnlitFloating.
Note
TheStatusLEDcanbeconguredtoashwhileaneventisactive.
TheStatusLEDcanbeconguredtoashforidentifyingtheunit.GotoSetup>AdditionalControllerConguration>
SystemOptions>Maintenance.
ConnectorsandButtons
Fortechnicalspecications,seepage56.
I/OInterface
ReaderDataConnector
Two6-pinterminalblockssupportingRS485andWiegandprotocolsforcommunicationwiththereader.Forspecications,see
page60.
ReaderI/OConnector
Two6-pinterminalblocksforreaderinputandoutput.Inadditiontothe0VDCreferencepointandpower(DCoutput),the
readerI/Oconnectorprovidestheinterfaceto:
DigitalinputForconnecting,forexample,readertamperingalarms.
DigitaloutputForconnecting,forexample,readerbeepersandreaderLEDs.
Forspecications,seepage60.
DoorConnector
Two4-pinterminalblocksforconnectingdoormonitoringdevicesandrequesttoexit(REX)devices.Forspecications,seepage6
1.
AuxiliaryConnector
4-pincongurableI/Oterminalblock.Usewithexternaldevices,incombinationwith,forexampletamperingalarms,eventtriggering
andalarmnotications.Inadditiontothe0VDCreferencepointandpower(DCoutput),theauxiliaryconnectorprovidesthe
interfaceto:
DigitalinputAnalarminputforconnectingdevicesthatcantogglebetweenanopenandclosedcircuit,forexamplePIR
sensorsorglassbreakdetectors.
DigitaloutputForconnectingexternaldevicessuchasburglaralarms,sirensorlights.Connecteddevicescanbe
activatedbytheVAPIX®applicationprogramminginterfaceorbyanactionrule.
Forspecications,seepage61.
ExternalPowerInputs
NO NO
NO
TICE TICE
TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnectingtheproducttothenetworkshall
beintendedfortheirspecicuse.Makesurethatthenetworkdevicesareinstalledinaccordancewiththemanufacturer’s
instructions.Forinformationaboutregulatoryrequirements,seeElectromagneticCompatibility(EMC)onpage2.
PowerConnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheithera
ratedoutputpowerlimitedto100Woraratedoutputcurrentlimitedto5A.Forspecications,seepage62.
NetworkConnector
RJ45Ethernetconnector.SupportsPoweroverEthernet(PoE).Forspecications,seepage62.
10
AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
PowerOutputs
PowerLockConnector
4-pinterminalblockforconnectingoneortwolocks.Thelockconnectorcanalsobeusedtopowerexternaldevices.For
specications,seepage62.
Power&RelayConnector
6-pinterminalblockforconnectingpowerandthedoorcontroller’srelaytoexternaldevicessuchaslocksandsensors.For
specications,seepage62.
ButtonsandOtherHardware
TamperingAlarmPinHeader
Two2-pinheadersfordisconnectingthefrontandbacktamperingalarms.Forspecications,seepage63.
ControlButton
Thecontrolbuttonisusedfor:
Resettingtheproducttofactorydefaultsettings.Seepage52.
ConnectingtoanAXISVideoHostingSystemservice.Seepage47.Toconnect,pressandholdthebuttonforabout1
seconduntiltheStatusLEDashesgreen.
ConnectingtoAXISInternetDynamicDNSService.Seepage47.Toconnect,pressandholdthebuttonforabout3seconds.
11
AXISA1001NetworkDoorController&AXISEntryManager
AccesstheProduct
AccesstheProduct
ToinstalltheAxisproduct,seetheInstallationGuidesuppliedwiththeproduct.
Theproductcanbeusedwithmostoperatingsystemsandbrowsers.Therecommendedbrowsersare
InternetExplorer
®
withWindows
®
Safari
®
withOSX
®
and
Chrome
TM
orFirefox
®
withotheroperatingsystems.
SeeTechnicalSpecicationsonpage56.
AccessfromaBrowser
1.Startabrowser(Chrome,InternetExplorer,Firefox,Safari).
2.EntertheIPaddressorhostnameoftheAxisproductinthebrowser’sLocation/Addresseld.
ToaccesstheproductfromaMaccomputer(OSX),gotoSafari,clickonBonjourandselecttheproductfromthe
drop-downlist.
IfyoudonotknowtheIPaddress,useAXISIPUtilitytolocatetheproductonthenetwork.Forinformationabout
howtodiscoverandassignanIPaddress,seethesupportpagesatwww.axis.com/techsuportheInstallationGuide
availableatwww.axis.com
Note
ToshowBonjourasabrowserbookmark,gotoSafari>Preferences.
3.Enteryourusernameandpassword.Ifthisisthersttimetheproductisaccessed,therootpasswordmustrstbe
congured.Forinstructions,seeSettheRootPasswordonpage12.
4.AXISEntryManageropensinyourbrowser.ThestartpageiscalledtheOverviewpage.
AccessfromtheInternet
Onceconnected,theAxisproductisaccessibleonyourlocalnetwork(LAN).ToaccesstheproductfromtheInternetyoumust
congureyournetworkroutertoallowincomingdatatrafctotheproduct.Todothis,enabletheNAT-traversalfeature,whichwill
attempttoautomaticallyconguretheroutertoallowaccesstotheproduct.ThisisenabledfromSetup>AdditionalController
Conguration>SystemOptions>Network>TCP/IP>Advanced.
Formoreinformation,seeNATtraversal(portmapping)forIPv4onpage48.SeealsoAXISInternetDynamicDNSServiceat
www.axiscam.net
ForTechnicalnotesonthisandothertopics,visittheAxisSupportwebatwww.axis.com/techsup
SettheRootPassword
ToaccesstheAxisproduct,youmustsetthepasswordforthedefaultadministratoruserroot.ThisisdoneintheCongureRoot
Passworddialog,whichopenswhentheproductisaccessedforthersttime.
Topreventnetworkeavesdropping,therootpasswordcanbesetviaanencryptedHTTPSconnection,whichrequiresanHTTPS
certicate.HTTPS(HypertextTransferProtocoloverSSL)isaprotocolusedtoencrypttrafcbetweenwebbrowsersandservers.The
HTTPScerticateensuresencryptedexchangeofinformation.SeeHTTPSonpage43.
Thedefaultadministratorusernamerootispermanentandcannotbedeleted.Ifthepasswordforrootislost,theproductmustbe
resettothefactorydefaultsettings.SeeResettoFactoryDefaultSettingsonpage52.
12
AXISA1001NetworkDoorController&AXISEntryManager
AccesstheProduct
TosetthepasswordviaastandardHTTPconnection,enteritdirectlyinthedialog.
TosetthepasswordviaanencryptedHTTPSconnection,followthesesteps:
1.ClickUseHTTPS.
Atemporarycerticate(validforoneyear)iscreated,enablingencryptionofalltrafctoandfromtheproduct,andthe
passwordcannowbesetsecurely.
2.Enterapasswordandthenre-enterittoconrmthespelling.
3.ClickOK.Thepasswordhasnowbeencongured.
TheOverviewPage
TheOverviewpageinAXISEntryManagershowsinformationaboutthedoorcontroller’sname,MACaddress,IPaddress,and
rmwareversion.Italsoenablesyoutoidentifythedoorcontrolleronthenetworkorinthesystem.
ThersttimeyouaccesstheAxisproduct,theOverviewpagewillpromptyoutocongurethehardware,tosetdateandtime,to
congurethenetworksettings,andtocongurethedoorcontrolleraspartofasystemorasastandaloneunit.Formoreinformation
aboutconguringthesystem,seeCongurationStepbySteponpage14.
ToreturntotheOverviewpagefromtheproduct’sotherwebpages,clickOverviewinthemenubar.
13
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
SystemConfiguration
Toopentheproduct’sSetuppages,clickSetupinthetopright-handcorneroftheOverviewpage.
TheAxisproductcanbeconguredbyadministrators.Formoreinformationaboutusersandadministrators,seepage26,page3
1,
andpage43.
CongurationStepbyStep
Beforeyoustartusingtheaccesscontrolsystem,youshouldcompletethefollowingsetupsteps:
1.IfEnglishisnotyourrstlanguage,youmaywantAXISEntryManagertouseadifferentlanguage.SeeSelectaLanguage
onpage14.
2.Congurethedoorcontrollerandconnecteddevicessuchasreaders,locksandrequesttoexit(REX)devices.SeeCongure
theHardwareonpage15.
3.VerifytheHardwareConnections.Seepage19.
4.Setthedateandtime.Seepage20.
5.Congurethenetworksettings.Seepage21.
6.Congurecardformats.Seepage21.
7.Congurethedoorcontrollersystem.SeeManageNetworkDoorControllersonpage23.
Forinformationabouthowtocongureandmanagethesystem'sdoors,schedules,usersandgroups,seeAccessManagementon
page26.
Forinformationaboutmaintenancerecommendations,seeMaintenanceInstructionsonpage25.
Note
Toaddorremovedoorcontrollers,toadd,remove,oreditusers,ortocongurethehardware,morethanhalfofthedoor
controllersinthesystemmustbeonline.Tocheckthedoorcontrollerstatus,gotoSetup>ManageNetworkDoor
ControllersinSystem.
SelectaLanguage
ThedefaultlanguageofAXISEntryManagerisEnglish,butyoucanswitchtoanyofthelanguagesthatareincludedintheproduct’s
rmware.Forinformationaboutthelatestavailablermware,seewww.axis.com
Youcanswitchlanguagesinanyoftheproduct’swebpages.
Toswitchlanguages,clickthelanguagedrop-downlist
andselectalanguage.Alltheproduct’swebpagesandhelppagesare
displayedintheselectedlanguage.
Important
Languageselectionissupportedfromrmware1.25.Ifthedoorcontrollerusesanearlierversion,youneedtoupgradethe
rmwarebeforeyoucanselectalanguage.SeeUpgradetheFirmwareonpage53.
Languagesettingsarenotsharedbetweendoorcontrollersinthesystem.Eitherselectthelanguageinalldoorcontrollers,
oralwaysopenAxisEntryManagerfromthesamedoorcontroller.
14
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
Note
Whenyouswitchlanguages,thedateformatalsochangestoaformatcommonlyusedintheselectedlanguage.The
correctformatisdisplayedinthedataelds.
Ifyouresettheproducttofactorydefaultsettings,AXISEntryManagerswitchesbacktoEnglish.
Ifyourestoretheproduct,AXISEntryManagerwillcontinuetousetheselectedlanguage.
Ifyourestarttheproduct,AXISEntryManagerwillcontinuetousetheselectedlanguage.
Ifyouupgradethermware,AXISEntryManagerwillcontinuetousetheselectedlanguage.
ConguretheHardware
Beforeyoucanmanagethedoors,thehardwaremustbeconguredintheHardwareCongurationpages.
Doors,locksandotherdevicescanbeconnectedtotheAxisproductbeforecompletingthehardwareconguration.However,the
connectionofdeviceswillbeeasierifyoucompletethehardwarecongurationrst.Thisisbecausethehardwarepinchartwillbe
availablewhenthecongurationiscomplete.Thehardwarepinchartisaguideonhowtoconnectthepinsandcanbeusedasa
referencesheetformaintenance.Formaintenanceinstructions,seepage25.
Ifconguringthehardwareforthersttime,selectoneofthefollowingmethods:
Importahardwarecongurationle.Seepage15.
Createanewhardwareconguration.Seepage16.
ImportaHardwareCongurationFile
ThehardwarecongurationoftheAxisproductcanbecompletedfasterbyimportingahardwarecongurationle.
Byexportingthelefromoneproductandimportingittoothers,youcanmakemultiplecopiesofthesamehardwaresetupwithout
havingtorepeatthesamestepsoverandoveragain.Youcanalsostoreexportedlesasbackupsandusethemtorestoreprevious
hardwarecongurations.Formoreinformation,seeExportaHardwareCongurationFileonpage15.
Toimportahardwarecongurationle:
1.GotoSetup>HardwareConguration.
2.ClickImporthardwarecongurationor,ifthereahardwarecongurationalreadyexists,Resetandimporthardware
conguration.
3.Inthelebrowserdialogthatappears,locateandselectthehardwarecongurationle(*.json)onyourcomputer.
4.ClickOK.
ExportaHardwareCongurationFile
ThehardwarecongurationoftheAxisproductcanbeexportedtomakemultiplecopiesofthesamehardwaresetup.Youcanalso
storeexportedlesasbackupsandusethemtorestoreprevioushardwarecongurations.
Note
AssaAperio
TM
settingsarenotincludedinthehardwarecongurationexport.
Toexportahardwarecongurationle:
1.GotoSetup>HardwareConguration.
2.ClickExporthardwareconguration.
3.Dependingonthebrowser,youmayneedtogothroughadialogtocompletetheexport.
Unlessotherwisespecied,theexportedle(*.json)issavedinthedefaultdownloadfolder.Youcanselectadownload
folderinthewebbrowser’susersettings.
15
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
CreateaNewHardwareConguration
Tocreateanewhardwarecongurationfromthebeginning:
1.GotoSetup>HardwareCongurationandclickStartnewhardwareconguration.
Iftheproduct’shardwarehasnotbeenconguredbeforeorhasbeendeleted,HardwareCongurationwillbeavailablein
thenoticationpanelintheOverviewpage.
2.Enteradescriptivenameforeachdoor.Itisrecommendedtoprovidethedoorswithuniquedescriptivenamessothatthey
easilycanbeidentifedbyanyonewhowilladministratethesystem.
YoucanalsoeditthenameoftheAxisproduct.Thedefaultnameincludestheserialnumberforeasyidentication.
3.SelectAperioifthesystemincludesanAssaAperiocommunicationhub.
IfthesystemincludesanAperiohubonly,clickFinish.Wirelessdoors/devicesareconguredafterHardwareConguration
iscompleted.SeeAddWirelessDoorsandDevicesonpage16.Otherwisecontinuewiththenextstep.
4.Selectadooroptiondependingonthenumberofdoors,one(1)ortwo(2),thatwillbeconnectedtotheAxisproduct
andclickNext
Note
OnlyonedoorisavailableifAperiowascheckedinthepreviousstep.
5.Selectthedoormonitorandlockoptionsthatmatchtherequirementsandthetypeoflockconnectionsthatwillbeused
andclickNext.Formoreinformation,seeCongureLocksandDoorMonitorsonpage16andLockOptionsonpage17.
6.SelectthetypesofreadersthatwillbeusedandclickFinish.Formoreinformation,seeCongureReadersandREXDevices
onpage18andReaderandREXDeviceOptionsonpage18.
7.Inthedialogthatappearsaftercompletingtheconguration,clickOKorclickthelinktoviewthehardwarepinchart.
Toprintthehardwarepinchart,clickPrintHardwarePinChartontheHardwarePinChartpage.
Tocancelthehardwareconguration,clickCancel.Thiscanbedoneinanyofthehardwarecongurationpages.
AddWirelessDoorsandDevices
BeforeaddingawirelessdoortothesystemitneedstobepairedwiththeconnectedAssaAperiocommunicationhub,using
AperioPAP(Aperioprogrammingapplicationtool).
Toaddawirelessdoor:
1.GotoSetup>HardwareReconguration.
2.UnderWirelessDoorsandDevicesclickAdddoor.
3.IntheDoornameeld:Enteradescriptivename.
4.IntheIDeldunderLock:Enterthesix-character-longaddressofthedevicethatyouwanttoadd.Thedeviceaddressis
printedontheproductlabel.
5.ClickAdd.
CongureLocksandDoorMonitors
1.Ifadoormonitorwillbeused,selectDoormonitorandthenselecttheoptionthatmatcheshowthedoormonitor
circuitswillbeconnected.
2.Ifthedoorlockshalllockimmediatelyafterthedoorhasbeenopened,selectCancelaccesstimeoncedoorisopened.
3.Specifythedoormonitortimeoptionsor,ifnodoormonitorwillbeused,thelocktimeoptions.
16
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
4.Selecttheoptionsthatmatchhowthelockcircuitswillbeconnected.
5.Ifalockmonitorwillbeused,selectLockmonitorandthenselecttheoptionsthatmatchhowthelockmonitorcircuits
willbeconnected.
6.Iftheinputconnectionsfromreaders,REXdevices,anddoormonitorsshallbesupervised,selectEnablesupervisedinputs.
Formoreinformation,seeUseSupervisedInputsonpage19.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
Youcanconnectonelockmonitorperdoorcontroller.Soifyouusedouble-lockdoors,onlyoneofthelockscanhavealock
monitor.Iftwodoorsareconnectedtothesamedoorcontroller,lockmonitorscannotbeused.
Motorizedlocksmustbeconguredassecondarylocks.
DoorMonitorOptions
Thefollowingdoormonitoroptionsareavailable:
DoormonitorSelectedbydefault.Eachdoorhasitsowndoormonitorthat,forexample,willsignalwhenthedoorhas
beenforcedopenoropentoolong.Deselectifnodoormonitorwillbeused.
-Opencircuit=CloseddoorSelectifthedoormonitorcircuitisnormallyopen.Thedoormonitorgivesthedoor
opensignalwhenthecircuitisclosed.Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisopen.
-Opencircuit=OpendoorSelectifthedoormonitorcircuitisnormallyclosed.Thedoormonitorgivesthedoor
opensignalwhenthecircuitisopen.Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisclosed.
CancelaccesstimeoncedoorisopenedSelecttopreventtailgating,thatis,stopunauthorizedvisitorsfromaccessing
thedoor.Thedoorwilllockimmediatelyafterthedoorhasbeenopened.Whenthedoorcloses,thedoorwillbelockedand
cannotbeopeneduntilauserrequestsandisgrantedaccessagain.
Thefollowingdoormonitortimeoptionsareavailable:
AccesstimeSetthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoorremains
unlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhethertheaccesstimehasexpiredor
not.Ifthedoorremainsunopened,itlockswhenthesetaccesstimehasbeenreached.
OpentoolongtimeSetthenumberofsecondsthedoorisallowedtostayopen.Ifthedoorisstillopenwhenthe
opentoolongtimehasbeenreached,thedooropentoolongalarmistriggered.Setupanactionruletocongurewhich
actiontheopentoolongeventshalltrigger.
Pre-alarmtimeApre-alarmisawarningsignalthatistriggeredbeforetheopentoolongtimehasbeenreached.It
tellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(theperson
enteringthedoor)thatthedoorneedstobeclosedortherealalarm,thedooropentoolongalarm,willgooff.Setthe
numberofsecondsbeforethedooropentoolongalarmistriggeredthesystemshallgivethepre-alarmwarningsignal.
Todisablethepre-alarm,setthepre-alarmtimeto0.
Forinformationabouthowtosetupanactionrule,seeSetUpActionRulesonpage36.
LockOptions
DeselectDoormonitortomakethefollowinglocktimeoptionsavailable:
DoorunlockedtimeSetthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoor
remainsunlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhetherthedoorunlockedtime
hasexpiredornot.Ifthedoorremainsunopened,itlockswhenthesetdoorunlocktimehasbeenreached.
Pre-locksignaltimeApre-locksignalisawarningsignalthatistriggeredbeforethedoorlocks.Ittellstheadministrator
and,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(thepersonenteringthedoor)that
thedoorwilllocksoon.Setthenumberofsecondsbeforethedoorlocksthesystemshallgivethepre-lockwarning
17
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
signal.Thepre-locksignaltimemustbeshorterthanthedoorunlockedtime.Todisablethepre-lockwarningsignal,
setthepre-locksignaltimeto0.
Thefollowinglockcircuitoptionsareavailable:
12V
-Fail-secureSelectforlocksthatremainlockedduringpoweroutages.Whenapplyingelectriccurrent,the
lockwillunlock.
-Fail-safeSelectforlocksthatunlockduringpoweroutages.Whenapplyingelectriccurrent,thelockwilllock.
RelayCanonlybeusedononelockperdoorcontroller.Iftwodoorsareconnectedtothedoorcontroller,arelaycan
onlybeusedonthelockoftheseconddoor.
-Relayopen=LockedSelectforlocksthatremainlockedwhentherelayisopen(fail-secure).Whenthe
relaycloses,thelockwillunlock.
-Relayopen=UnlockedSelectforlocksthatunlockduringpoweroutages(fail-safe).Whentherelaycloses,
thelockwilllock.
NoneSelectifonlyonelockwillbeused.
Thefollowinglockmonitoroptionsareavailable:
LockmonitorSelecttomakethelockmonitorcontrolsavailable.Thenselectthelockthatshallbemonitored.Alock
monitorcanonlybeusedondouble-lockdoorsandcannotbeusediftwodoorsareconnectedtothedoorcontroller.
-Opencircuit=LockedSelectifthelockmonitorcircuitisnormallyclosed.Thelockmonitorgivesthedoor
unlockedsignalwhenthecircuitisclosed.Thelockmonitorgivesthedoorlockedsignalwhenthecircuitisopen.
-Opencircuit=UnlockedSelectifthelockmonitorcircuitisnormallyopen.Thelockmonitorgivesthedoor
unlockedsignalwhenthecircuitisopen.Thelockmonitorgivesthedoorlockedsignalwhenthecircuitisclosed.
Forinformationabouthowtosetupanactionrule,seeSetUpActionRulesonpage36.
CongureReadersandREXDevices
1.Ifareaderwillbeused,selectReaderandthenselecttheoptionsthatmatchthereader’scommunicationprotocol.
2.Ifarequesttoexit(REX)devicesuchasabutton,sensor,orpushbarwillbeused,selectREXandthenselecttheoption
thatmatcheshowtheREXdevice’scircuitswillbeconnected.
Ifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor,selectREXdoesnotunlockdoor.
3.IfconnectingmorethanonereaderorREXdevicetothedoorcontroller,dotheprevioustwostepsagainuntileach
readerorREXdevicehasthecorrectsettings.
ReaderandREXDeviceOptions
Thefollowingreaderoptionsareavailable:
WiegandSelectforreadersthatuseWiegandprotocols.ThenselecttheLEDcontrolthatissupportedbythereader.
ReaderswithsingleLEDcontrolusuallytogglebetweenredandgreen.ReaderswithdualLEDcontrolusedifferentwires
fortheredandgreenLEDs.ThismeansthattheLEDsarecontrolledindependentlyofeachother.WhenbothLEDsareon,
thelightappearstobeamber.Seethemanufacturer’sinformationaboutwhichLEDcontrolthereadersupports.
RS485halfduplexSelectforRS485readerswithhalfduplexsupport.ThenselecttheRS485protocolthatissupported
bythereader.Seethemanufacturer’sinformationaboutwhichprotocolthereadersupports.
RS485fullduplexSelectforRS485readerswithfullduplexsupport.ThenselecttheRS485protocolthatissupported
bythereader.Seethemanufacturer’sinformationaboutwhichprotocolthereadersupports.
ThefollowingREXdeviceoptionsareavailable:
18
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
ActivelowSelectifactivatingtheREXdeviceclosesthecircuit.
ActivehighSelectifactivatingtheREXdeviceopensthecircuit.
REXdoesnotunlockdoorSelectifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor.
Thedoorforcedopenalarmwillnotbetriggeredaslongastheuseropensthedoorwithintheaccesstime.Deselectif
thedoorshallunlockautomaticallywhentheuseractivatestheREXdevice.
Important
Ifthedoorcontrollerhasonlybeenconguredwithonedoorbeforeitisupgradedtormware1.15orlaterfromrmware
1.10,REXdoesnotunlockdoorwillbenon-selectableatrst.TomakeREXdoesnotunlockdoorselectable,gotoSetup
>HardwareCongurationandclickResetandstartanewhardwareconguration.Thensetuptherulesforthedoors
connectedtothedoorcontrollerandaddthemtogroups,seeManageDoors.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
UseSupervisedInputs
Supervisedinputsreportonthestatusoftheconnectionbetweenthedoorcontrollerandthereaders,REXdevices,anddoor
monitors.Iftheconnectionisinterrupted,aneventisactivated.
Tousesupervisedinputs:
1.Installendoflineresistorsonalltheusedinputs.Seetheconnectiondiagramonpage64.
2.GotoSetup>HardwareRecongurationandselectEnablesupervisedinputs.Youcanalsoenablesupervisedinputs
duringthehardwareconguration.
SupervisedInputCompatibility
Thefollowingconnectorssupportsupervisedinputs:
ReaderI/Oconnectortamperingsignal.Seepage60.
Doorconnector.Seepage6
1.
Readersandswitchesthatcanbeusedwithsupervisedinputsinclude:
HIDreaderswithinternal1kΩpull-upto5V.
Readersandswitcheswithinternal1kΩpull-upto5V.
Readersandswitcheswithoutinternalpull-up.
VerifytheHardwareConnections
Whenthehardwareinstallationandcongurationiscomplete,andanytimeduringthedoorcontroller’slifetime,youcanverifythe
functionoftheconnecteddoormonitors,locksandreaders.
Toverifythecongurationandaccessthevericationcontrols,gotoSetup>HardwareConnectionVerication.
VericationControls
DoorstateVerifythecurrentstateofthedoormonitor,dooralarmsandlocks.ClickGetcurrentstate.
LockManuallytriggerthelock.Bothprimarylocksandsecondarylocksifthereareanywillbeaffected.ClickLockor
Unlock.
LockManuallytriggerthelocktograntaccess.Onlyprimarylockswillbeaffected.ClickAccess.
19
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
Reader:FeedbackVerifythereaderfeedback,forexamplesoundsandLEDsignals,fordifferentcommands.Selectthe
commandandclickTest.Whichtypesoffeedbackthatareavailabledependsonthereader.Formoreinformation,see
ReaderFeedback.Seealsothemanufacturer’sinstructions.
Reader:TamperingGetinformationaboutthelasttamperingattempt.Thersttamperingattemptwillberegistered
whenthereaderisinstalled.ClickGetlasttampering.
Reader:CardswipeGetinformationaboutthelastswipedcardorothertypeofusertokenacceptedbythereader.
ClickGetlastcredential.
REXGetinformationaboutthelasttimetherequesttoexit(REX)devicewaspressed.ClickGetlastREX.
SettheDateandTime
Ifthedoorcontrollerispartofasystem,thedateandtimesettingswillbedistributedtoallthedoorcontrollers.Thismeansthatthe
settingsarepushedtotheothercontrollersinthesystem,regardlessofwhetheryousynchronizewithanNTPserver,setthedateand
timemanually,orgetthedateandtimefromthecomputer.Ifyoucannotseethechanges,tryrefreshingthepageinyourbrowser.
Formoreinformationaboutmanagingasystemofdoorcontrollers,seeManageNetworkDoorControllersonpage23.
TosetthedateandtimeoftheAxisproduct,gotoSetup>Date&Time.
Youcansetthedateandtimeinthefollowingways:
Getthedateandtimefromanetworktimeprotocol(NTP)server.Seepage20.
Setthedateandtimemanually.Seepage20.
Getthedateandtimefromthecomputer.Seepage2
1.
Currentcontrollertimedisplaysthedoorcontroller’scurrentdateandtime(24hclock).
ThesameoptionsfordateandtimearealsoavailableintheSystemOptionspages.GotoSetup>AdditionalController
Conguration>SystemOptions>Date&Time.
GettheDateandTimefromaNetworkTimeProtocol(NTP)Server
1.GotoSetup>Date&Time.
2.SelectyourTimezonefromthedrop-downlist.
3.Ifdaylightsavingtimeisusedinyourregion,selectAdjustfordaylightsaving.
4.SelectSynchronizewithNTP.
5.SelectthedefaultDHCPaddressorentertheaddressofaNTPserver.
6.ClickSave.
WhensynchronizingwithanNTPserver,dateandtimeareupdatedcontinuouslybecausethedataispushedfromtheNTPserver.For
informationaboutNTPsettings,seeNTPCongurationonpage47.
IfyouuseahostnamefortheNTPserver,aDNSservermustbecongured.SeeDNSCongurationonpage47.
SettheDateandTimeManually
1.GotoSetup>Date&Time.
2.Ifdaylightsavingtimeisusedinyourregion,selectAdjustfordaylightsaving.
3.SelectSetdate&timemanually.
4.Enterthedesireddateandtime.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65

Axis A1001 User manual

Category
Security door controllers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI