Axis A9188 is a powerful network I/O relay module that combines the functionality of an I/O module and a relay output module into one compact and versatile device. It allows you to remotely control and monitor various electrical devices, such as lights, motors, and sensors, over a network connection. Here is a concise overview of its capabilities:

Remote control: With Axis A9188, you can control connected devices remotely via the network. This enables you to manage your devices from anywhere, at any time, using a web browser or the dedicated Axis mobile app.

I/O ports: Axis A9188 features four opto-isolated digital input ports and two relay output ports. The input ports allow you to connect switches, sensors, or other digital devices to monitor their status. The output ports can be used to control external devices, such as lights, motors, or solenoid valves.

Axis A9188 is a powerful network I/O relay module that combines the functionality of an I/O module and a relay output module into one compact and versatile device. It allows you to remotely control and monitor various electrical devices, such as lights, motors, and sensors, over a network connection. Here is a concise overview of its capabilities:

Remote control: With Axis A9188, you can control connected devices remotely via the network. This enables you to manage your devices from anywhere, at any time, using a web browser or the dedicated Axis mobile app.

I/O ports: Axis A9188 features four opto-isolated digital input ports and two relay output ports. The input ports allow you to connect switches, sensors, or other digital devices to monitor their status. The output ports can be used to control external devices, such as lights, motors, or solenoid valves.

AXISA9188NetworkI/ORelayModule
InstallationGuide-FullReference
Liability
Everycarehasbeentakeninthepreparationofthis
document.PleaseinformyourlocalAxisofceofany
inaccuraciesoromissions.AxisCommunicationsABcannot
beheldresponsibleforanytechnicalortypographicalerrors
andreservestherighttomakechangestotheproductand
manualswithoutpriornotice.AxisCommunicationsAB
makesnowarrantyofanykindwithregardtothematerial
containedwithinthisdocument,including,butnotlimited
to,theimpliedwarrantiesofmerchantabilityandtnessfor
aparticularpurpose.AxisCommunicationsABshallnot
beliablenorresponsibleforincidentalorconsequential
damagesinconnectionwiththefurnishing,performance
oruseofthismaterial.Thisproductisonlytobeusedfor
itsintendedpurpose.
Intellectualpropertyrights
AxisABhasintellectualpropertyrightsrelatingto
technologyembodiedintheproductdescribedinthis
document.Inparticular,andwithoutlimitation,these
intellectualpropertyrightsmayincludeoneormoreof
thepatentslistedatwww.axis.com/patent.htmandoneor
moreadditionalpatentsorpendingpatentapplicationsin
theUSandothercountries.
Equipmentmodications
Thisequipmentmustbeinstalledandusedin
strictaccordancewiththeinstructionsgiveninthe
userdocumentation.Thisequipmentcontainsno
user-serviceablecomponents.Unauthorizedequipment
changesormodicationswillinvalidateallapplicable
regulatorycerticationsandapprovals.
Trademarkacknowledgments
AXISCOMMUNICATIONS,AXISandVAPIXareregistered
trademarksortrademarkapplicationsofAxisABinvarious
jurisdictions.Allothercompanynamesandproductsare
trademarksorregisteredtrademarksoftheirrespective
companies.
Support
Learnmore!
VisitAxislearningcenterwww.axis.com/academy/for
usefultrainings,webinars,tutorialsandguides.
Regulatoryinformation
Europe
ThisproductcomplieswiththeapplicableCEmarking
directivesandharmonizedstandards:
ElectromagneticCompatibility(EMC)Directive
2014/30/EU.SeeElectromagneticcompatibility(EMC)
onpage2.
LowVoltage(LVD)Directive2014/35/EU.SeeSafety
onpage2.
RestrictionsofHazardousSubstances(RoHS)Directive
2011/65/EU.SeeDisposalandrecyclingonpage3.
Acopyoftheoriginaldeclarationofconformitymaybe
obtainedfromAxisCommunicationsAB.SeeContact
informationonpage3.
Electromagneticcompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll
applicablestandardsfor:
Radiofrequencyemissionwheninstalledaccordingto
theinstructionsandusedinitsintendedenvironment.
Immunitytoelectricalandelectromagneticphenomena
wheninstalledaccordingtotheinstructionsandused
initsintendedenvironment.
USA
Thisequipmenthasbeentestedusingashieldednetwork
cable(STP)andfoundtocomplywiththelimitsfora
ClassBdigitaldevice,pursuanttopart15oftheFCC
Rules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferenceinaresidential
installation.Thisequipmentgenerates,usesandcan
radiateradiofrequencyenergyand,ifnotinstalledand
usedinaccordancewiththeinstructions,maycause
harmfulinterferencetoradiocommunications.However,
thereisnoguaranteethatinterferencewillnotoccurin
aparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,which
canbedeterminedbyturningtheequipmentoffandon,
theuserisencouragedtotrytocorrecttheinterferenceby
oneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentand
receiver.
Connecttheequipmentintoanoutletonacircuit
differentfromthattowhichthereceiverisconnected.
Consultthedealeroranexperiencedradio/TV
technicianforhelp.
Theproductshallbeconnectedusingashieldednetwork
cable(STP)thatisproperlygrounded.
Canada
ThisdigitalapparatuscomplieswithCANICES-3(ClassB).
Theproductshallbeconnectedusingashieldednetwork
cable(STP)thatisproperlygrounded.Cetappareil
numériqueestconformeàlanormeCANNMB-3(classeB).
Leproduitdoitêtreconnectéàl'aided'uncâbleréseau
blindé(STP)quiestcorrectementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRF
emissionaccordingtotheClassBlimitofEN55022.The
productshallbeconnectedusingashieldednetworkcable
(STP)thatisproperlygrounded.
Thisproductfulllstherequirementsforimmunity
accordingtoEN61000-6-1residential,commercialand
light-industrialenvironments.
Thisproductfulllstherequirementsforimmunity
accordingtoEN61000-6-2industrialenvironments.
Thisproductfulllstherequirementsforimmunity
accordingtoEN55024ofceandcommercial
environments.
Thisproductfulllstherequirementsforimmunity
accordingtoEN50130-4residential,commercial,
light-industrialandindustrialenvironments.
Australia/NewZealand
ThisdigitalequipmentfulllstherequirementsforRF
emissionaccordingtotheClassBlimitofAS/NZSCISPR22.
Theproductshallbeconnectedusingashieldednetwork
cable(STP)thatisproperlygrounded.
Japan
この装置は、クラスB情報技術装置です。この装置
、家で使るこして
、こラジレビ信機
して使れる受信害を起こ
あり説明従っい取
して製品シーット
ーブ(STP)使⽤接続ださ
Safety
ThisproductcomplieswithIEC/EN60950-1,Safetyof
InformationTechnologyEquipment.
Ifitsconnectingcablesareroutedoutdoors,theproduct
shallbegroundedeitherthroughashieldednetworkcable
(STP)orotherappropriatemethod.
Thepowersupplyusedwiththisproductshallfulllthe
requirementsforSafetyExtraLowVoltage(SELV)according
toclause2.2ofIEC/UL60950-1andLimitedPowerSource
(LPS)accordingtoclause2.5ofIEC/UL60950-1orCEC/NEC
Class2sourceofsupplyasdenedintheCanadian
ElectricalCode,CSAC22.1andNationalElectricalCode,
ANSI/NFPA70.
Disposalandrecycling
Whenthisproducthasreachedtheendofitsusefullife,
disposeofitaccordingtolocallawsandregulations.For
informationaboutyournearestdesignatedcollectionpoint,
contactyourlocalauthorityresponsibleforwastedisposal.
Inaccordancewithlocallegislation,penaltiesmaybe
applicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbe
disposedoftogetherwithhouseholdorcommercialwaste.
Directive2012/19/EUonwasteelectricalandelectronic
equipment(WEEE)isapplicableintheEuropeanUnion
memberstates.Topreventpotentialharmtohumanhealth
andtheenvironment,theproductmustbedisposedofin
anapprovedandenvironmentallysaferecyclingprocess.
Forinformationaboutyournearestdesignatedcollection
point,contactyourlocalauthorityresponsibleforwaste
disposal.Businessesshouldcontacttheproductsupplierfor
informationabouthowtodisposeofthisproductcorrectly.
Thisproductcomplieswiththerequirementsof
Directive2011/65/EUontherestrictionoftheuseof
certainhazardoussubstancesinelectricalandelectronic
equipment(RoHS).
China
Thisproductcomplieswiththerequirementsof
SJ/T11364-2014,Markingfortherestrictionofhazardous
substancesinelectricalandelectronicproducts.
(Pb)
(Hg)
(Cd)
(Cr-
(VI))
(PB-
B)
(PB-
DE)
X
00000
0:表示有毒物质件所质材
的含均在GB/T26572标准定的限量求以下。
X:表示有害至少件的均质
的含GB/T26572定的
Contactinformation
AxisCommunicationsAB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
www.axis.com
AXISA9188NetworkI/ORelayModule
Safetyinformation
Hazardlevels
DANGER
Indicatesahazardoussituationwhich,ifnotavoided,willresultindeathorseriousinjury.
WARNING
Indicatesahazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderate
injury.
NO NO
NO
TICE TICE
TICE
Indicatesasituationwhich,ifnotavoided,couldresultindamagetoproperty.
Othermessagelevels
Important
Indicatessignicantinformationwhichisessentialfortheproducttofunctioncorrectly.
Note
Indicatesusefulinformationwhichhelpsingettingthemostoutoftheproduct.
5
AXISA9188NetworkI/ORelayModule
Safetyinstructions
WARNING
TheAxisproductshallbeinstalledbyatrainedprofessional,andincompliancewithlocal
lawsandregulations.
NO NO
NO
TICE TICE
TICE
TheAxisproductshallbeusedincompliancewithlocallawsandregulations.
Axisrecommendsusingashieldednetworkcable(STP)CAT5orhigher.
TousetheAxisproductoutdoors,orinsimilarenvironments,itshallbeinstalledinan
approvedoutdoorhousing.
StoretheAxisproductinadryandventilatedenvironment.
AvoidexposingtheAxisproducttoshocksorheavypressure.
Donotinstalltheproductonunstablepoles,brackets,surfacesorwalls.
UseonlyapplicabletoolswheninstallingtheAxisproduct.Usingexcessiveforcewith
powertoolscouldcausedamagetotheproduct.
Donotusechemicals,causticagents,oraerosolcleaners.
Useonlyaccessoriesthatcomplywiththetechnicalspecicationofyourproduct.These
canbeprovidedbyAxisorathirdparty.AxisrecommendsusingAxispowersource
equipmentcompatiblewithyourproduct.
UseonlysparepartsprovidedbyorrecommendedbyAxis.
Donotattempttorepairtheproductyourself.ContactAxissupportoryourAxisreseller
forservicematters.
Thepowersupplyshallbepluggedintoasocketoutletinstalledneartheproductand
shallbeeasilyaccessible.
Transportation
NO NO
NO
TICE TICE
TICE
WhentransportingtheAxisproduct,usetheoriginalpackagingorequivalenttoprevent
damagetotheproduct.
Battery
Lithiumcoincell3.0Vbatteriescontain1,2-dimethoxyethane;ethyleneglycoldimethylether
(EGDME),CASno.110-71-4.
6
AXISA9188NetworkI/ORelayModule
WARNING
Riskofexplosionifthebatteryisincorrectlyreplaced.
ReplaceonlywithanidenticalbatteryorabatterywhichisrecommendedbyAxis.
Disposeofusedbatteriesaccordingtolocalregulationsorthebatterymanufacturer's
instructions.
7
8
AXISA9188NetworkI/ORelayModule
InstallationGuide-FullReference
ThisfullreferenceinstallationguideprovidesinstructionsforhowtoinstallAXISA9188Network
I/ORelayModuleonyournetwork.
Foraquickreferenceguide,seetheprintedAXISA9188InstallationGuideQuick
Referencethatisincludedinthepackagecontents.Thequickreferenceguideisalso
availableonwww.axis.com
Forotheraspectsofusingtheproduct,seetheAXISA9188UserManualavailable
onwww.axis.com
RequirementsforCompliancewithUL2946thEdition
RequirementsforCompliancewithUL2946thEdition
ThissectioncontainsinformationandinstructionsrequiredforULcompliance.Tomakesurethe
installationisULcompliant,followtheinstructionsbelowinadditiontothegeneralinformation
andinstructionsprovidedthroughoutthisdocument.Incaseswherepiecesofinformation
contradicteachother,therequirementsforULcompliancealwaysreplacegeneralinformation
andinstructions.
PerformanceLevelsforAccessControl
ThissectioncontainsperformancelevelinformationrequiredforUL294compliance.
FeatureLevel
DestructiveAttackTestI
LineSecurity
I
EnduranceIV
StandbyPower
I
SafetyInstructions
TheAxisproductshallbeinstalledandservicedbyafactorytrainedprofessional.
TheAxisproductshallbeinstalledwithintheprotectedpremises(securedarea).
TheAxisproductshallbemountedindoors.Outdoorusehasnotbeenevaluatedor
approvedbyUL.
AllinterconnectingdevicesshallbeULListedandClass2low-voltagepowerlimited.
AllwiringmethodsshallbeperformedinaccordancewithNFPA70,localcodesand
authoritieshavingjurisdiction.
9
AXISA9188NetworkI/ORelayModule
WhentheAxisproducthasreachedtheendofitsusefullife,disposeofitaccording
tolocallawsandregulations.Theproductshouldnotbedisposedoftogetherwith
householdorcommercialwaste.SeeDisposalandrecyclingonpage3.
Battery
-The3.0VlithiumbatteryusedbytheAxisproductisaULRecognized
component.(Type:BR2032,diameter:20mm(0.78in),manufacturers:
Rayovac,Panasonic).ThefollowingbatterytypeisalsoaULRecognized
component:TypeCR2032,manufacturers:Fuji,Maxell,Renata,Varta,
Panasonic,JHIH
-Usersshallnotreplacethebattery.Ifthebatteryneedsreplacing,
afactorytrainedserviceprofessionalshallcontactAxissupport
atwww.axis.com/techsupforassistance.
-Usedbatteriesshallbedisposedofaccordingtolocallawsandregulations,
whichmayvaryfromstatetostate.WasteBR/CRlithiumcellsareneither
listednorexemptedfromtheUSEPAhazardouswasteregulations.Waste
lithiumbatteriescanbeconsideredreactivehazardouswasteifthereisa
signicantamountofunreacted,orunconsumedlithiumremaining.For
informationabouthowtodisposeofusedlithiumbatteries,contactyourlocal
authorityforwastedisposal.
Specications
OperatingConditions
-ClassicationIEC60721-4-3Class3M3
-Temperatures-35°Cto66°C(31°Fto150.8°F).
-Humidity20–85%RH(non-condensing)
Wirearea
-ULListedorR/CAWMwiresthathaveanconductorgaugerangeof
AWG22–14shallbeused.
-Theminimumconductorgaugeforconnectionbetweenthepowersourcing
equipment(PSE)orpowerinjectorandthepowereddevice(PD)is26AWG.
Connectors
-ThisproductisnotintendedforoutsidewiringascoveredbyArticle800inthe
NationalElectricalCode,NFPA70.
-PowerConnectorForULsecurityapplications,theproductshallbepowered
byaUL294ListedorUL603ListedClass2low-voltagepowerSELVand
limitedpowersupplythatiscapableof4hoursofstandbypower.
-Externalpowertorelays-Iftherelaysareconnectedtoanexternalpower
sourcethismustbeUL294ListedorUL603ListedClass2low-voltagepower
SELVandlimitedpowersupplythatiscapableof4hoursofstandbypower.
-NetworkConnectorPoweroverEthernet(PoE)shallbesuppliedbyaUL294
ListedPoweroverEthernetIEEE802.3af/802.3atType1Class3orPowerover
EthernetPlus(PoE+)IEEE802.3atType2Class4powerlimitedinjectorthat
provides44–57VDC,15.4W/30Wand4hoursofstandbypower.
10
AXISA9188NetworkI/ORelayModule
-CompliancewithIEEE802.3(atoraf)specicationsisnotveriedaspart
ofUL294B.
-TamperingAlarmPinHeaderTocomplywithUL294/7.2.1(Enclosure),the
tamperingalarmshallbeconnectedtoasoundalarm.
SystemConsiderations
-TheAxisproductshallnotimpairtheintendedoperationofthepanichardware
usedinconjunctionwithit.
WallandCeilingMount
-IfusingajunctionboxtomounttheAxisproduct,thejunctionboxshallbe
ULListed.
AssignanIPAddress
-ThefunctionalityofAXISCameraManagementhasnotbeenevaluatedbyUL.
MaintenanceInstructions
-Formaintenanceinstructionsandforinformationabouthowtocongurethe
Axisproduct,seetheUserManual.
FurtherInformation
-Firmwareversion:NetworkI/ORelayModule,ModelA9188-1.0
InstallationSteps
1.Makesurethepackagecontents,toolsandothermaterialsnecessaryfortheinstallation
areinorder.Seepage11.
2.Studythehardwareoverview.Seepage12.
3.Studythespecications.Seepage21.
4.Installthehardware.Seepage14.
Packagecontents
AXISA9188Module
2-pinplugconnector(2x)
3-pinplugconnector(2x)
4-pinplugconnector(9x)
7-pinplugconnector(2x)
Relayjumpers(8x)
TorxKeyTR20
Printedmaterials
-AXISA9188InstallationGuide
-Overviewlabel
-Extraserialnumberlabel(2x)
11
AXISA9188NetworkI/ORelayModule
-AVHSAuthenticationkey
-AXISCameraStationlicence
Hardwareoverview
Forspecicationsofthehardwarecomponents,see.
1
SupervisedI/Oandpowerconnector(DCOUT)port1–4
2
SupervisedI/Oandpowerconnector(DCOUT)port5–8
3
12/24Vpowerconnector(DCOUT)
4
Relayconnector(8x)
5
Relayjumper(8x)
6
Networkconnector(PoE)
7
Powerconnector(DCIN)
8
RS-485connector(notused)
12
AXISA9188NetworkI/ORelayModule
9
Tamperingalarminput
10
12/24Vpowerconnector(DCOUT)
LEDindicators,buttons
1
I/OLEDindicators(8x)
2
I/OovercurrentLEDindicator
3
Controlbutton
4
RelayLEDindicators(8x)
5
StatusLEDindicator
6
NetworkLEDindicator
7
I/OovercurrentLEDindicator
8
PowerLEDindicator
LED
Color
Indication
Green
Steadyforconnectiontoa100MBit/snetwork.Flashesfor
networkactivity.
Amber
Steadyforconnectiontoa10MBit/snetwork.Flashesfornetwork
activity.
Network
UnlitNonetworkconnection.
13
AXISA9188NetworkI/ORelayModule
GreenSteadygreenfornormaloperation.
Amber
Steadyduringstartupandwhenrestoringsettings.
Status
Red
Slowashforfailedupgrade.
Green
Normaloperation. Power
Amber
Flashesgreen/amberduringrmwareupgrade.
Green
Relaycoilisenergized Relay
UnlitRelaycoilisunenergized
Green
I/Oisgrounded
Unlit
I/Oisoating
I/O
Blinking
Tampererror(wirecutoropen)
Red
Overcurrent
RS485(not
used)
UnlitNormalstate
Red
Overcurrent
I/Ovoltage
UnlitNormalstate
Installthehardware
SystemConsiderations
TheAxisproductshallbeinstalledwithinasecuredarea.
TheAxisproduct,whetheritisinstalledasasingleelevatorcontrollerorinasystemofcontrollers,
shallnotlimitorweakentheintendeduseofthedevicesconnectedtoit.
TheAxisproductshouldbeinstalledwithaDINrailonawall(preferred)oraceiling,withor
withoutajunctionbox.
Note
TheAxisproductisconsideredstandalone,anddoesnotrequireconstantconnectiontoa
computerforproperoperation.Theuseofaconnectedcomputerisforlocalprogramming,
downloading,andsupplementalmonitoringpurposesonly.
ElevatorrecallforrehasnotbeenevaluatedbyUL.
WallandCeilingMount
1.Ifusingajunctionbox,installthejunctionboxbeforeinstallingtheIORelayModule.
14
AXISA9188NetworkI/ORelayModule
2.FastentheDINrailonthewall.Makesurethatthescrewsandplugsareappropriatefor
thematerial(e.g.wood,metal,sheetrock,stone)
3.MakesurethattheDINclippositiononthemetalplateisoptimal.See
AXISA9188InstallationGuideQuickReference
4.AttachtheproducttotheDINrail
5.Connectthecables.Seepage15.
ConnecttheCables
CAUTION
DisconnectpowerbeforeconnectinganywirestotheAxisproduct.Nevermakeconnections
whilepowerisappliedtotheproduct.
NO NO
NO
TICE TICE
TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnecting
theproducttothenetworkshallbeintendedfortheirspecicuse.Makesurethatthe
networkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For
informationaboutregulatoryrequirements,seeRegulatoryinformationonpage2.
IfusingPoweroverEthernet,waitwithconnectingthenetworkcabletothenetworkuntil
alltheotherwireshavebeenconnected.
Toallowforfuturemaintenance,toavoidexcessivestrainonwiresandconnectors,andto
avoiddamagetoconductorinsulation,leaveaserviceloopandmakesureallcablesand
wiresareproperlysupportedandsecured.
Toprotectthecircuitsagainstelectrostaticdischarge(ESD),useESDprotectionwhen
connectingwirestotheproduct.
1.Stripthecablesandwiresasrequiredusingacablestrippingtool.
2.Userelayjumperstoprovideinternalpowertoauxiliaryequipmentconnectedtothe
relayconnectors.SeeRelayJumperonpage25.
3.ConnectthewiresbetweentheIORelayModuleandtheexternaldevices.Formore
informationabouttheconnectorsandtheirspecications,seeConnectorsonpage22.
NO NO
NO
TICE TICE
TICE
Makesureallthewiresareconnectedcorrectly.Incorrectwiringcouldcausedamage
totheproduct.
Makesuretousewiresthatmeettherequirements.Formoreinformation,seeWire
Areaonpage22.
Note
Forinformationabouthowtoconnectotherwires,suchaspowerwirestolocksandother
devices,seethemanufacturers’instructions.
15
AXISA9188NetworkI/ORelayModule
4.Collectallthewiresneatlyandsecurethem.
5.Labelthecablesforfuturereference.
6.IfusingPoweroverEthernet,connectthenetworkcabletothenetwork.
7.MakesurethattheLEDsindicatethecorrectconditionsandthatnoneoftheovercurrent
LEDsarelit.Seeonpage13.
AccesstheProduct
Howtoaccesstheproductfromabrowser
1.Startawebbrowser.
2.EntertheIPaddressorhostnameoftheAxisproductinthebrowser’saddresseld.
IfyoudonotknowtheIPaddress,useAXISIPUtilitytolocatetheproductonthenetwork.
ForinformationabouthowtodiscoverandassignanIPaddress,seeAssignanIPAddress.
Thisinformationisalsoavailablefromthesupportpagesatwww.axis.com/support
Note
ToshowBonjourasabrowserbookmark,gotoSafari>Preferences.
3.Enteryourusernameandpassword.Ifthisisthersttimetheproductisaccessed,the
rootpasswordmustrstbecongured.
4.AXISI/OManageropensinyourbrowser.ThestartpageiscalledtheDashboard.
HowtoaccesstheproductfromtheInternet
Onceconnected,theAxisproductisaccessibleonyourlocalnetwork(LAN).Toaccesstheproduct
fromtheInternetyoumustcongureyournetworkroutertoallowincomingdatatrafctothe
product.Todothis,enabletheNAT-traversalfeature,whichwillattempttoautomaticallycongure
theroutertoallowaccesstotheproduct.ThisisenabledfromPreferences>AdditionalDevice
Conguration>SystemOptions>Network>TCP/IP>Advanced.
FormoreinformationaboutNATtrasversalforIPv4,seetheproduct’sUserManual.SeealsoAXIS
InternetDynamicDNSServiceatwww.axiscam.net
ForTechnicalnotesonthisandothertopics,visittheAxisSupportwebatwww.axis.com/support
AssignanIPAddress
DefaultIPAddress
TheAxisproductisdesignedforuseonanEthernetnetworkandrequiresanIPaddressforaccess.
MostnetworkshaveaDHCPserverthatautomaticallyassignsIPaddressestoconnecteddevices.
16
AXISA9188NetworkI/ORelayModule
IfyournetworkdoesnothaveaDHCPservertheAxisproductwilluse192.168.0.90asthe
defaultIPaddress.
RecommendedMethodsinWindows®
AXISIPUtilityandAXISCameraManagementarerecommendedmethodsforndingAxis
productsonthenetworkandassigningthemIPaddressesinWindows®.Bothapplicationsarefree
andcanbedownloadedfromwww.axis.com/techsup
AXISIPUtilitySmallInstallations
AXISIPUtilityautomaticallydiscoversanddisplaysAxisproductsonyournetwork.Theapplication
canalsobeusedtomanuallyassignastaticIPaddress.
NotethatthecomputerrunningAXISIPUtilitymustbeonthesamenetworksegment(physical
subnet)astheAxisproduct.
AutomaticDiscovery
1.CheckthattheAxisproductisconnectedtothenetworkandhaspoweredup.
2.StartAXISIPUtility.
3.WhentheAxisproductappearsinthewindow,double-clicktoopenitswebpages.
4.Forinformationabouthowtosetthepassword,seepage20.
AssigntheIPAddressManually(optional)
1.AcquireanavailableIPaddressonthesamenetworksegmentasyourcomputer.
2.SelecttheAxisproductinthelist.
3.ClickAssignnewIPaddresstoselecteddevice
andentertheIPaddress.
4.ClickAssignandcontinueaccordingtotheinstructions.
5.WhentheAxisproductappearsinthewindow,double-clicktoopenitswebpages.
6.Forinformationabouthowtosetthepassword,seepage20.
AXISCameraManagementLargeInstallations
AXISCameraManagementisapowerfulinstallationandmanagementtoolforAxisnetwork
products.Thetoolcanautomaticallysearchthenetworkfordevices,assignIPaddresses,set
passwords,showconnectionstatus,managermwareupgradesandcongureproductparameters.
Itcanperformbatchoperationsonmultipleproductsatonce.
AutomaticDiscovery
1.CheckthattheAxisproductisconnectedtothenetworkandhaspoweredup.
17
AXISA9188NetworkI/ORelayModule
2.StartAXISCameraManagement.
3.Connecttoaserver.
Toconnecttoaserveronthenetwork,selectRemoteserverandselectaserverfromthe
drop-downlistorentertheIPorDNSaddressintheeld.
Toconnecttoaserverrunninglocallyonyourcomputer,selectThiscomputer.
4.ClickLogOntologonasthecurrentcomputeruser,orde-selectLogonascurrentuser
andentertheusernameandpasswordtologonwith.
5.ThersttimeAXISCameraManagementrunsitautomaticallysearchesforAxisproducts
onthenetwork.Tomanuallysearchforproducts,selectConguration>AddDevices.
Thesoftwaredisplaysalistoftheproductsfound.
SelecttheproductstoaddandclickNextandthenclickFinish.
6.Inthelistofdevices,clickontheaddresstoopentheproduct’swebpages.
7.Forinformationabouthowtosetthepassword,seepage20.
AssignIPAddressesinMultipleDevices
AXISCameraManagementspeedsuptheprocessofassigningIPaddressestomultipledevicesby
suggestingIPaddressesfromaspeciedrange.
1.Selectthedevicesyouwishtocongure(differentmodelscanbeselected)andclick
AssignIPaddresstoselecteddevices
.
2.ClickYesintheDeviceMaintenancedialog.
3.SelectAssignthefollowingIPaddressrangeandentertheIPaddressrange,subnet
maskanddefaultrouterthedeviceswilluse.ClickNext.
4.SuggestedIPaddressesarelistedunderNewIPAddressesandcanbeeditedbyselecting
adeviceandclickingEditIP.
5.ClickFinish.
OtherOperatingSystemsandMethods
ThelistbelowshowstheothermethodsavailableforassigningordiscoveringtheIPaddress.All
methodsareenabledbydefault,andallcanbedisabled.
AVHSServiceConnection(alloperatingsystems).ToconnecttoanAVHSservice,refer
totheserviceprovider’sInstallationguide.Forinformationandhelpinndingalocal
AVHSServiceProvider,gotowww.axis.com/hosting
AXISCameraStation5(Windows®).Forinformationandhelp,gotowww.axis.com/vms
UPnP(Windows®).Whenenabledonyourcomputer,theAxisnetworkproductis
automaticallydetectedandaddedtoNetwork/MyNetworkPlaces.
Bonjour(MacOSX®10.4orlater).ApplicabletobrowserswithsupportforBonjour.
NavigatetotheBonjourbookmarkinyourbrowser(forexampleSafari)andclickon
thelinktoaccessthewebpages.
18
AXISA9188NetworkI/ORelayModule
AXISDynamicDNSService(alloperatingsystems).AfreeservicefromAxisthatallows
youtoquicklyandsimplyinstallyourAxisnetworkproduct.RequiresanInternet
connectionwithoutanHTTPproxy.Formoreinformation,seewww.axiscam.net
ARP/Ping(alloperatingsystems).SeeAssignIPAddressUsingARP/Ping.Thecommand
mustbeissuedwithin2minutesofconnectingpower.
DHCPserver(alloperatingsystems).ToviewtheadminpagesforthenetworkDHCP
server,seetheserver’suserdocumentation.
AssignIPAddressUsingARP/Ping
Theproduct'sIPaddresscanbeassignedusingARP/Ping.Thecommandmustbeissuedwithin2
minutesofconnectingpower.
1.AcquireafreestaticIPaddressonthesamenetworksegmentasthecomputer.
2.Locatetheserialnumber(S/N)ontheproductlabel.
3.Openacommandpromptandenterthefollowingcommands:
Linux/Unixsyntax
arp-s<IPaddress><serialnumber>temp
ping-s408<IPaddress>
Linux/Unixexample
arp-s192.168.0.12500:40:8c:18:10:00temp
ping-s408192.168.0.125
Windowssyntax(thismayrequirethatyourunthecommandpromptasan
administrator)
arp-s<IPaddress><serialnumber>
ping-l408-t<IPaddress>
Windowsexample(thismayrequirethatyourunthecommandpromptasan
administrator)
arp-s192.168.0.12500-40-8c-18-10-00
ping-l408-t192.168.0.125
4.Restarttheproductbydisconnectingandreconnectingthenetworkconnector(PoE).
5.ClosethecommandpromptwhentheproductrespondswithReplyfrom
192.168.0.125:...orsimilar.
6.Openabrowserandtypehttp://<IPaddress>intheLocation/Addresseld.
Note
ToopenacommandpromptinWindows,opentheStartmenuandtypecmdinthe
Run/Searcheld.
TousetheARPcommandinWindows8/Windows7/WindowsVista,right-clickthe
commandprompticonandselectRunasadministrator.
ToopenacommandpromptinMacOSX,opentheTerminalutilityfromApplication>
Utilities.
19
AXISA9188NetworkI/ORelayModule
Howtosettherootpassword
ToaccesstheAxisproduct,youmustsetthepasswordforthedefaultadministratoruserroot.
ThisisdoneintheCongureRootPassworddialog,whichopenswhentheproductisaccessed
forthersttime.
Topreventnetworkeavesdropping,therootpasswordcanbesetviaanencryptedHTTPSconnection,
whichrequiresanHTTPScerticate.HTTPS(HypertextTransferProtocoloverSSL)isaprotocol
usedtoencrypttrafcbetweenwebbrowsersandservers.TheHTTPScerticateensuresencrypted
exchangeofinformation.
Thedefaultadministratorusernamerootispermanentandcannotbedeleted.Ifthepasswordfor
rootislost,theproductmustberesettothefactorydefaultsettings.Forinformationabouthowto
resettheproducttofactorydefault,seetheproduct’sUserManual.
TosetthepasswordviaastandardHTTPconnection,enteritdirectlyinthedialog.
TosetthepasswordviaanencryptedHTTPSconnection,followthesesteps:
1.ClickUseHTTPS.
Atemporarycerticate(validforoneyear)iscreated,enablingencryptionofalltrafcto
andfromtheproduct,andthepasswordcannowbesetsecurely.
2.Enterapasswordandthenre-enterittoconrmthespelling.
3.ClickOK.Thepasswordhasnowbeencongured.
Howtoresettofactorydefaultsettings
MaintenanceInstructions
TokeepthenetworkI/Omodulerunningsmoothly,Axisrecommendsregularmaintenanceofthe
networkI/Omoduleandconnecteddevices.
Domaintenanceatleastonceayear.Thesuggestedmaintenanceprocedureincludes,butisnot
limitedto,thefollowingsteps:
MakesurealltheconnectionsbetweennetworkI/Omoduleandtheexternaldevices
aresecure.
Verifyallthehardwareconnections.Thisrequiresaccesstotheproduct’swebpages.
Iftheresultsfromanyofthestepsaboveindicatefaultsorunexpectedbehavior:
-Testthesignalsofthewiresusingappropriateequipmentandcheckifthe
wiresorcablesaredamagedinanyway.
-Replacealldamagedorfaultycablesandwires.
-Oncethecablesandwireshavebeenreplaced,verifyallthehardware
connectionsagain.Thisrequiresaccesstotheproduct’swebpages.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Axis A9188 Installation guide

Type
Installation guide

Axis A9188 is a powerful network I/O relay module that combines the functionality of an I/O module and a relay output module into one compact and versatile device. It allows you to remotely control and monitor various electrical devices, such as lights, motors, and sensors, over a network connection. Here is a concise overview of its capabilities:

Remote control: With Axis A9188, you can control connected devices remotely via the network. This enables you to manage your devices from anywhere, at any time, using a web browser or the dedicated Axis mobile app.

I/O ports: Axis A9188 features four opto-isolated digital input ports and two relay output ports. The input ports allow you to connect switches, sensors, or other digital devices to monitor their status. The output ports can be used to control external devices, such as lights, motors, or solenoid valves.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI