Hagerco 8418 - Single Operator Operating instructions

Type
Operating instructions
8400 Series Low Energy Operator with Electric Strike
Installation and Programming Instructions
I-CL00647
Page of Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.HagerCo.comRev 1, Rev Date: 6/4/15
Figure 1
DISPLAY
PROGOPEN EXIT
+- E
OFF AUTO
Programmer
DISPLAY
PROGOPEN EXIT
+- E
OFF AUTO
FIGURE 2
5
Enter Programming mode
Press and hold multifunction push button/control until
LED flashes red 4 times. After the 4
th
red flash release the
multifunction push button/control.
Programming (Refer to Figure 2)
(PROGRAMMER REFER TO FIGURE 2)
1) Press and release + (AUTO) to navigate to ‘
Param STG’.
2) Press E (BLUE BUTTON) to enter parameter settings.
3) Press and release + (AUTO to navigate to ‘
Locking’.
4) Press E (BLUE BUTTON) to enter ‘
Locking’.
5) Press E (BLUE BUTTON) to enter ‘
Lock Function’.
6) Press and release + (AUTO) to navigate to ‘
Always Locked’.
7) Press E (BLUE BUTTON) to select ‘
Always Locked’.
8) Press and release PROG button until display reads ‘
Quit menu
item’.
9) Press E (BLUE BUTTON) to exit programing.
Description Of Operation: Activation of Auto Operator releases electric strike and opens door.
1 3
8400 Series Low Energy Operator with Electric Strike
Installation and Programming Instructions
I-CL00647
Page of Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.HagerCo.comRev 1, Rev Date: 6/4/15
NOTE: USE EITHER
FAIL SAFE OR FAIL
SECURE CONNECTION
DO NOT USE BOTH.
FAIL SECURE
FAIL SAFE
POWER
CONNECTOR
24VDC
RED
WHITE
COM
N/O
N/C
COM
N/O
N/C
Description Of Operation: Activation of Auto Operator releases electric strike and opens door.
Electrical Output: .5A at 24VDC
Products:
Hager 8418 Low Energy Operator
24VDC Electric Strike
Hardwired Actuators
Inside Actuator
Outside Actuator
2 3
N/C
FIRE ALARM
CONTACT
NOTE: Fire alarm contact
only required on fire
rated opening. If door is
not required to be self
closing and self latching
factory jumper should be
installed between
terminal 14 and 15.
8400 Series Low Energy Operator with Electric Strike
Installation and Programming Instructions
I-CL00647
Page of Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.HagerCo.comRev 1, Rev Date: 6/4/15
12-24V
AC/DC
COM
NO
NC
ON
OFF
POWER
LEARN
HOLD
TIME
DELAY
NO
DELAY
Description Of Operation: Activation of Auto Operator releases electric strike and opens door.
Electrical Output: .5A at 24VDC
Products:
1ea Hager 8418 Low Energy Operator
1ea 24VDC Electric Strike
2ea 2-659-0172 or 2-659-0173 Hardwired Actuators
1ea 2-659-0183 Wireless Receiver
2ea 2-659-0184 or 2-659-0185 Wireless Transmitters
NOTE: USE EITHER
FAIL SAFE OR FAIL
SECURE CONNECTION
DO NOT USE BOTH.
FAIL SECURE
FAIL SAFE
POWER
CONNECTOR
24VDC
RED
WHITE
3 3
RED
BLACK
WHITE
GREEN
N/C
FIRE ALARM
CONTACT
NOTE: Fire alarm contact
only required on fire
rated opening. If door is
not required to be self
closing and self latching
factory jumper should be
installed between
terminal 14 and 15.
Inside Actuator
COM
N/O
N/C
Outside Actuator
COM
N/O
N/C
  • Page 1 1
  • Page 2 2
  • Page 3 3

Hagerco 8418 - Single Operator Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI