ETC P-TS18-RM Installation guide

Type
Installation guide

ETC P-TS18-RM is a rack mount kit that provides the ability to install the Paradigm 18” Touchscreen into a 19” rack, utilizing 8U of rack space. The rack mount kit includes a mounting bracket, two panel mounted USB connectors with extension cables for connection to the P-TS18 and mounting hardware. This allows for convenient use of the touchscreen USB ports from the front of the rack mount panel. The kit also includes two USB cables that install between the USB ports on the touchscreen and the USB port receptacles on the rack mount panel.

ETC P-TS18-RM is a rack mount kit that provides the ability to install the Paradigm 18” Touchscreen into a 19” rack, utilizing 8U of rack space. The rack mount kit includes a mounting bracket, two panel mounted USB connectors with extension cables for connection to the P-TS18 and mounting hardware. This allows for convenient use of the touchscreen USB ports from the front of the rack mount panel. The kit also includes two USB cables that install between the USB ports on the touchscreen and the USB port receptacles on the rack mount panel.

ETC
®
Installation Guide
Paradigm 18" Touchscreen Rack Mount Kit
Paradigm 18" Touchscreen Rack Mount Kit Installation GuidePage 1 of 2 Electronic Theatre Controls, Inc.
Corporate Headquarters
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
Tel +608 831 4116
Fax +608 836 1736
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8896 2000
Rome, IT
Via Pieve Torina, 48, 00156 Rome, Italy
Tel +39 (06) 32 111 683
Fax +44 (0) 20 8752 8486
Holzkirchen, DE
Ohmstrasse 3, 83607 Holzkirchen, Germany
Tel +49 (80 24) 47 00-0
Fax +49 (80 24) 47 00-3 00
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Tel +852 2799 1220
Fax +852 2799 9325
Service:
(Americas) service@etcconnect.com
(UK) servic[email protected]
(DE) techserv-hoki@etcconnect.com
Web:
www.etcconnect.com
Copyright © 2013 ETC. All Rights Reserved.
Product information and specifications subject to change.
7184M2220
Rev A
Released 2013-01
ETC intends this document to be provided in its entirety.
Overview
The Paradigm 18” Touchscreen Rack Mount Kit (P-TS18-RM) provides the ability to install the
Paradigm 18” Touchscreen (P-TS18) into a 19” rack, utilizing 8U of rack space.
Installation
Step 1: Locate the Paradigm 18” Touchscreen (P-TS18), the accessory box from the P-TS18
packaging, and the rack mounting kit.
Step 2: Remove and discard the four screws from the back panel of the touchscreen.
Note:
The Paradigm 18” Touchscreen ships with a table top stand which is not required
when rack mounting. Recycle or discard the stand parts.
The P-TS18-RM rack mount kit
includes a mounting bracket, two
panel mounted USB connectors
with extension cables for
connection to the P-TS18 and
mounting hardware.
ETC Installation Guide
Paradigm 18" Touchscreen Rack Mount Kit
Paradigm 18" Touchscreen Rack Mount Kit Installation GuidePage 2 of 2 Electronic Theatre Controls, Inc.
Step 3: Attach the touchscreen to the rack mount panel using four screws provided in the
touchscreen accessory box.
Step 4: The rack mount kit includes two USB cables that install between the USB ports on the
touchscreen and the USB port receptacles on the rack mount panel. Attach these cables
between the two products. This connection allows convenient use of the touchscreen
USB ports from the front of the rack mount panel.
Step 5: Locate the international power supply and cables in the P-TS18 accessory box.
Step 6: Slide the power supply (from either side) into the bracket on the back panel of the rack
mount.
Final Installation
Connect Power and Data
Power
Step 1: Insert the power supply round plug into the “12V DC IN” receptacle located on the back
of the touchscreen.
Step 2: Locate the correct IEC power cable for your region from the P-TS18 accessory box.
Step 3: Attach the IEC cable between the power supply and the power source.
Data
Step 1: Connect the touchscreen to the Paradigm network by plugging an Ethernet cable
between the P-TS18 “LAN1” connector and then into a network connection that is
connected to the Paradigm Central Control Server (P-CCS) or network switch.
Power Up
Step 1: Attach the rack mounting panel with the touchscreen installed to a 19” rack enclosure
using the four M10 screws, washers and the spring clips provided with the rack mount kit.
Step 2: Apply power to the circuit.
Step 3: Reference the Paradigm 18” Touchscreen Setup and Connect Guide for further
instruction to use the touchscreen and Virtual Touchscreen (VTS) application.
Step 3:
international
power supply
Step 6:
Step 4:
  • Page 1 1
  • Page 2 2

ETC P-TS18-RM Installation guide

Type
Installation guide

ETC P-TS18-RM is a rack mount kit that provides the ability to install the Paradigm 18” Touchscreen into a 19” rack, utilizing 8U of rack space. The rack mount kit includes a mounting bracket, two panel mounted USB connectors with extension cables for connection to the P-TS18 and mounting hardware. This allows for convenient use of the touchscreen USB ports from the front of the rack mount panel. The kit also includes two USB cables that install between the USB ports on the touchscreen and the USB port receptacles on the rack mount panel.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI