Thermo Fisher Scientific BioCAD® 700E Workstation User guide

Type
User guide
BioCADĀ® 700E Workstation for
Perfusion ChromatographyĀ®
Version 3 Series Software
User Guide
Ā© Copyright 2000, Applied Biosystems
All rights reserved
For Research Use Only. Not for use in diagnostic procedures.
Information in this document is subject to change without notice. Applied Biosystems assumes no responsibility for any errors that
may appear in this document. This document is believed to be complete and accurate at the time of publication. In no event shall
Applied Biosystems be liable for incidental, special, multiple, or consequential damages in connection with or arising from the use
of this document.
POROS products and perfusive chromatography are covered by US patents 5,030,352; 5,019,270; and 5,228,989; other US and
foreign patents pending. BioCAD and INTEGRAL Workstations are covered by US patent 5,552,041; other US and foreign patents
pending. Chromatography materials of certain pore geometries, including certain wide-pore supports, can permit perfusive
chromatography, that is, separations in which the rate of intraparticle convection exceeds the rate of intraparticle diffusion. Use of
any such chromatography media at sufficiently high linear velocity, without license, constitutes infringement of US patent
5,019,270. A limited license to use the patented perfusive chromatography process is granted with the purchase of POROS
products from Applied Biosystems. The license terminates upon expiration of the useful life of the product. Purchasers of BioCAD
and INTEGRAL Workstations have the right to practice the subject matter of US patent 5, 552,041 on the workstation purchased
for the useful life of the workstation.
Subtractive Assay technology, enabled by the use of ImmunoDetection (ID) Sensor Cartridges and the INTEGRAL
Micro-Analytical Workstation, is covered by US patent 5,234,586. Patents pending on ImmunoDetection Technology, assays
enabled by ID Sensor Cartridges, and Perfusion Immunoassays. Other patents pending.
Applied Biosystems, BioCAD, Perfusion Chromatography, POROS, SCOUT, and the fractal icon are registered trademarks of
Applera Corporation or its subsidiaries in the U.S. and certain other countries.
AB (Design), ABI, Applera, ChromatoCAD, ID, ImmunoDetection, SPRINT, Supervisor, and VISION are trademarks of Applera
Corporation or its subsidiaries in the U.S. and certain other countries.
Advantec is a registered trademark of Toyo Roshi International, Inc.
Eppendorf is a registered trademark of Eppendorf-Netheler-Hinz GMBH.
EZ is a trademark of Scientific Software, Inc.
Gilson is a registered trademark of Gilson, Inc.
Kel F is a registered trademark of 3M Company.
Kynar is a registered trademark of Union Carbide.
Microsoft and Windows are registered trademarks of Microsoft Corporation.
Pentium is a registered trademark of Intel Corporation.
RheFlex is a registered trademark and Rheodyne is a trademark of Rheodyne, L.P.
SLO-BLO is a trademark of Littlefuse, Inc.
SpectraSYSTEM and PushLoop are registered trademarks of Thermo Separation Products.
Swagelok is a registered trademark of Crawford Fitting Co.
Teflon and Tefzel are registered trademarks of E.I. Du Pont de Nemours and Co.
Tygon is a registered trademark of Norton Company.
Zip is a trademark and Iomega is a registered trademark of Iomega Corporation.
All other trademarks are the sole property of their respective owners.
Printed in the USA, 12/2000
Part Number 602478-02 Rev. A
WARNINGWARNING
For continued protection against fire hazard, replace fuses with those
of the same type and rating.
AVERTISSEMENT
Remplacez les fusibles par ceux de mĆŖme type et puissance pour
Ć©viter les risques dā€™incendie.
WARNINGWARNING
Before handling any chemicals, refer to the Material Safety Data Sheet
provided by the manufacturer, and observe all relevant precautions.
AVERTISSEMENT
Avant de manipuler des produits chimiques, veuillez consulter la fiche
de sƩcuritƩ du matƩriel fournie par le fabricant, et observer les
mesures de prĆ©caution qui sā€™imposent.
WARNINGWARNING
Always wear eye protection when working with solvents or any
pressurized liquids.
AVERTISSEMENT
Porter toujours des protections pour les yeux lorsque vous manipulez
des solvants ou tout autre liquide sous pression.
WARNINGWARNING
PEEK tubing is a polymeric material. Use caution when working with
any polymer tubing under pressure.
1. Always wear eye protection when in close proximity to pressurized
polymer tubing.
2. Extinguish all nearby flames if using flammable solvents.
3. Do not use PEEK tubing that has been severely stressed or
kinked.
4. Do not use PEEK tubing with tetrahydrofuran or concentrated nitric
and sulfuric acids.
5. Methylene chloride and dimethyl sulfoxide cause PEEK tubing to
swell and greatly reduce the rupture pressure of the tubing.
6. With high solvent flow rates (40 ml/min), a static charge may build
up on the surface of the tubing. Electrical sparks may result.
AVERTISSEMENT
Le tubage PEEK est un matĆ©riau polymĆØre. Prenez des prĆ©cautions
lorsque vous travaillez avec un tubage polymĆØre sous pression.
1.Porter toujours des protections pour les yeux lorsque vous vous
trouvez Ć  proximitĆ© dā€™un tubage polymĆØre sous pression.
2.Ɖteindre toutes les flammes avoisinantes si vous utilisez des
solvants inflammables.
3.Nes pas utiliser un tubage PEEK qui a dƩjƠ ƩtƩ sƩrieusement
travaillƩ ou pliƩ.
4.Nes pas utiliser un tubage PEEK avec du tƩtrahydrofurane ou des
acides nitriques et sulfuriques concentrƩs.
5.Le chlorure de mĆ©thylĆØne et le sulfoxyde de dimĆ©thyle entraĆ®nent un
gonflement du tubage PEEK et rƩduisent fortement la rƩsistance Ơ la
rupture du tubage.
6.Avec des dĆ©bits dā€™Ć©coulement de solvants Ć©levĆ©s (>Ć” 40 ml/min),
une charge statique puet se dƩvelopper sur la surface du tubage. Des
Ʃtincelles Ʃlectriques peuvent en rƩsulter.
WARNINGWARNING
Use this product only as specified in this document. Using this system
in a manner not specified may result in injury or damage to the system.
AVERTISSEMENT
Veuillez suivre avec attention les indications figurant dans ce
document lorsque vous utilisez ce produit. Un usage diffƩrent le
systĆØme causer un accident ou endommager le systĆØme.
CAUTION
Failure to leave the pH and conductivity monitors in a 1 M salt solution
and to run the SYSCLEAN method after daily use may result in system
downtime. See Section 2.6, Starting Up and Shutting Down, for the
recommended procedure.
CAUTION
Do not use methylene chloride, tetrahydrofuran, dimethyl sulfoxide, or
concentrated nitric or sulfuric acids. These materials are not
compatible with the PEEK components in the BioCAD 700E
Workstation.
CAUTION
Certain organic solvents, such as acetonitrile and isopropanol used
over long time periods or in high concentrations, can weaken PEEK
tubing on the BioCAD 700E Workstation. Change the PEEK tubing on
the workstation periodically if you use organic solvents frequently or in
high concentrations. For more information, contact Applied Biosystems
Technical Support.
CAUTION
If you are using organic solvents, bypass the pH and conductivity
monitors to prevent damage. You can bypass the pH and conductivity
monitors by clicking the Bypass option button in the pH/Cond section
of the Control Panel or in the General Settings of a method.
US Safety and EMC (Electromagnetic Compatibility) Standards
Safety
This instrument has been tested to and complies with standard ANSI/UL 3101-1, ā€œElectrical
Equipment for Laboratory Use; Part 1: General Requirementsā€, 1st Edition. It is an ETL Testing
Laboratories listed product.
EMC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the userā€™s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Note: Shielded cables must be used with this unit to ensure compliance with the Class A FCC
limits.
Canadian Safety and EMC (Electromagnetic Compatibility) Standards
Safety
This instrument has been tested to and complies with standard CSA 1010, ā€œSafety Requirements
for Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General
Requirementsā€. It is an ETL Testing Laboratories listed product.
SƩcuritƩ
Cet instrument a Ć©tĆ© vĆ©rifiĆ© avec la norme CSA 1010, Ā«SpĆ©cifications de sĆ©curitĆ© du matĆ©riel
Ʃlectrique utilisƩ pour les mesures, les contrƓles et dans les laboratoires ; Partie 1 : SpƩcifications
gĆ©nĆ©ralesĀ», et il est conforme Ć  cette norme. Cā€™est un produit homologuĆ© par les ETL Testing
Laboratories.
EMC
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numĆ©rique de la classe A respecte toutes les exigences du RĆØglement sur le
materiel brouilleur du Canada.
European Safety and EMC (Electromagnetic Compatibility) Standards
Declaration of Conformity
Application of Council Directive(s): 73/23/EEC ā€œLow Voltageā€
89/336/EEC ā€œElectromagnetic Compatibilityā€
Standard(s) to which conformity is
declared: EN61010-1:1993, ā€œSafety Requirements for Electrical Equipment for
Measurement, Control and Laboratory Useā€
EN55011:1991, Group 1, Class B ā€œRadiated Emissionsā€
EN50082-1:1991 ā€œGeneric Immunityā€
Manufacturerā€™s Name: Applied Biosystems
Manufacturerā€™s Address: 500 Old Connecticut Path
Framingham, Massachusetts 01701 USA
Type of Equipment: Laboratory Instrumentation
Model Name: BioCAD 700E Workstation
Model Number: 5-1004-75
Serial Number: 1068 and later
Year of Manufacture: 1997 and later
Table of Contents
BioCADĀ® 700E Workstation User Guide ix
Table of Contents
How to Use This Guide......................................................................... xxi
Chapter 1 Introducing the BioCADĀ® 700E Workstation
1.1 System Features .................................................................................. 1-2
1.2 Systematic Method Development with Perfusion Chromatography ....... 1-4
1.3 Parts of the System.............................................................................. 1-8
1.3.1 Front Panel Indicators and Controls ..................................... 1-9
1.3.2 Buffer/Solvent and Pump System ........................................1-10
1.3.3 Sample Loader ....................................................................1-12
1.3.4 Columns and Plumbing .......................................................1-14
1.3.5 Detectors and Monitors .......................................................1-16
1.3.6 Fraction Collection ..............................................................1-19
1.3.7 Computer Components .......................................................1-20
1.4 BioCAD Software Overview................................................................. 1-21
1.4.1 System Control ...................................................................1-22
1.4.2 Configuration ......................................................................1-26
1.4.3 Method Editor .....................................................................1-27
1.4.4 Data Analysis Software .......................................................1-29
1.5 BioCAD Software File Structure........................................................... 1-30
1.5.1 File Types ...........................................................................1-30
1.5.2 File Contents .......................................................................1-31
1.5.3 Directories ..........................................................................1-33
1.6 A Quick Introduction to Microsoft Windows.......................................... 1-36
1.6.1 Using the Desktop and Windows .........................................1-36
1.6.2 Using the Mouse and Menus ...............................................1-40
1.6.3 Using the Open File Dialog Box ..........................................1-42
Table of Contents
x Applied Biosystems
Chapter 2 Installing the BioCAD 700E Workstation
2.1 Initial Installation .................................................................................. 2-2
2.2 Site Requirements................................................................................ 2-3
2.2.1 General Requirements ......................................................... 2-3
2.2.2 Changing the Voltage Setting ............................................... 2-5
2.2.3 Cold Room Operation .......................................................... 2-6
2.3 Connecting Tubing ............................................................................... 2-7
2.3.1 Connecting the Compressed Gas Supply Line ..................... 2-7
2.3.2 Connecting the Helium Supply Line ...................................... 2-8
2.3.3 Connecting the Buffer/Solvent and Sparge Lines ................. 2-9
2.3.4 Connecting the Pump Seal Wash Lines ...............................2-12
2.3.5 Connecting the Waste Lines ................................................2-12
2.4 Connecting External Devices............................................................... 2-13
2.4.1 Connecting an External Detector
(UV/Vis or Fluorescence) ....................................................2-14
2.4.2 Connecting an Auxiliary Detector ........................................2-16
2.4.3 Connecting the Fraction Collector .......................................2-18
2.4.4 Connecting the Autosampler ...............................................2-21
2.4.5 Connecting a SCOUT Column Selector ...............................2-23
2.4.6 Connecting a Strip Chart Recorder or Integrator ..................2-23
2.4.7 Connecting the Keyboard, Monitor, and Mouse ...................2-24
2.4.8 Connecting a Printer ...........................................................2-25
2.4.9 Connecting to a Network .....................................................2-25
2.4.10 Connecting Peripheral Devices ...........................................2-26
2.5 Installing the BioCAD Software............................................................ 2-27
2.5.1 Installing the Software .........................................................2-27
2.5.2 Updating BioCAD Hardware Setup Options .........................2-31
2.5.3 Installing the Hardware Key ................................................2-33
2.5.4 Starting the Software ...........................................................2-34
2.5.5 Exiting the Software ............................................................2-36
2.6 Starting Up and Shutting Down............................................................ 2-37
Table of Contents
BioCADĀ® 700E Workstation User Guide xi
Chapter 3 Preparing the Workstation and External
Devices
3.1 Plumbing the Workstation..................................................................... 3-2
3.1.1 Selecting Tubing Diameter and Length ................................. 3-2
3.1.2 Connecting Fittings to Tubing ............................................... 3-4
3.1.3 Plumbing Tubing and Columns ............................................. 3-9
3.1.4 Changing the Syringe and Sample Loop .............................3-13
3.2 Preparing Buffers, Solvents, and Solutions.......................................... 3-17
3.2.1 Preparing Buffers/Solvents ..................................................3-18
3.2.2 Preparing pH Blend Mode Buffers .......................................3-20
3.2.3 Preparing Pump Seal Wash Solution ...................................3-22
3.3 Preparing Samples.............................................................................. 3-23
3.3.1 Preparing Samples for Autoloader Injections
(Small Vessels) ...................................................................3-23
3.3.2 Preparing Samples for Autoloader Injections
(Large Vessels) ...................................................................3-24
3.3.3 Preparing Samples for Direct Autoloader Injections .............3-25
3.3.4 Preparing Samples for Manual Injections ............................3-26
3.3.5 Preparing Samples for Pump Injections ...............................3-27
3.4 Priming and Flushing the System ........................................................ 3-28
3.4.1 Priming the Pump Seal Wash Lines ....................................3-28
3.4.2 Priming the Buffer/Solvent Lines .........................................3-30
3.4.3 Priming and Flushing the Autoloader Sample Lines ............3-34
3.4.4 Priming Buffer/Solvent Sample Lines for a Pump
Injection ..............................................................................3-37
3.5 Preparing the Fraction Collector.......................................................... 3-39
3.5.1 Installing Fraction Collector Racks ......................................3-39
3.5.2 Setting Fraction Collector Mode ..........................................3-40
3.5.3 Preparing Fraction Collector Software .................................3-40
Table of Contents
xii Applied Biosystems
3.6 Preparing an Autosampler................................................................... 3-43
3.6.1 Preparing the Autosampler Software ...................................3-44
3.6.2 Plumbing Autosampler Injector Valve ..................................3-46
3.6.3 Attaching the Compressed Gas Supply ...............................3-48
3.6.4 Preparing Autosampler Solvents .........................................3-48
3.6.5 Priming the Autosampler .....................................................3-49
3.6.6 Preparing Sample Vials .......................................................3-51
3.6.7 Loading Vials in Autosampler Trays ....................................3-53
3.6.8 Programming the AS 3500 Autosampler Method and
Sample Set .........................................................................3-56
Chapter 4 Configuring and Preparing the BioCAD
Software
4.1 Configuration Overview ........................................................................ 4-2
4.2 Creating a New Configuration............................................................... 4-4
4.2.1 Configuring the Pump .......................................................... 4-5
4.2.2 Configuring Buffers/Solvents ................................................ 4-6
4.2.3 Configuring the Autoloader ................................................... 4-7
4.2.4 Configuring Columns and Plumbing ....................................4-11
4.2.5 Configuring Detectors .........................................................4-15
4.3 Saving and Printing Configurations...................................................... 4-20
4.4 Loading an Existing Configuration ....................................................... 4-22
4.5 Customizing Configuration Libraries.................................................... 4-24
4.5.1 Customizing the Buffer/Solvent Library ...............................4-25
4.5.2 Customizing the Sample Library ..........................................4-29
4.5.3 Customizing the Column Library .........................................4-32
4.6 Configuring and Preparing the BioCAD Software for a
Fraction Collector................................................................................ 4-35
Table of Contents
BioCADĀ® 700E Workstation User Guide xiii
4.7 Configuring and Preparing the BioCAD Software for an
Integrated Autosampler....................................................................... 4-36
4.7.1 Configuring Integrated Autosampler ....................................4-36
4.7.2 Customizing the Sample Library ..........................................4-44
4.7.3 Entering Vials in Sample Table ............................................4-46
4.8 Configuring and Preparing the BioCAD Software for a
Direct Wire Autosampler ..................................................................... 4-53
Chapter 5 Controlling the Workstation From the Control
Panel
5.1 Overview.............................................................................................. 5-2
5.2 Controlling Workstation Components and Systems............................... 5-4
5.2.1 Changing the Syringe and Sample Loop .............................. 5-4
5.2.2 Controlling Buffers/Solvents and Blending ............................ 5-8
5.2.3 Controlling the Pump and Flow Rate ...................................5-13
5.2.4 Purging the System .............................................................5-15
5.2.5 Controlling Columns ............................................................5-18
5.2.6 Controlling Detectors ..........................................................5-20
5.2.7 Controlling the Fraction/Waste Valve ...................................5-23
5.2.8 Running a Gradient .............................................................5-24
5.2.9 Calibrating Custom pH Blend Buffers ..................................5-26
5.2.10 Programming Event Outputs ...............................................5-31
5.2.11 Stopping and Resuming a Method .......................................5-33
5.3 Making Injections From the Control Panel ........................................... 5-34
5.3.1 Making Autoloader Injections ..............................................5-36
5.3.2 Making Direct Autoloader Injections ....................................5-38
5.3.3 Making Manual Injections ....................................................5-40
5.3.4 Making Pump Injections ......................................................5-42
5.4 Controlling External Devices................................................................ 5-43
5.4.1 Controlling the Fraction Collector ........................................5-43
5.4.2 Controlling an Integrated Autosampler ................................5-46
5.4.3 Controlling a Direct Wire Autosampler .................................5-51
Table of Contents
xiv Applied Biosystems
Chapter 6 Creating and Running Methods
6.1 Using the Method Editor....................................................................... 6-2
6.1.1 Method Structure .................................................................. 6-3
6.1.1.1 Blocks ................................................................ 6-4
6.1.1.2 Segments ........................................................... 6-5
6.1.1.3 Events ................................................................ 6-7
6.1.2 Method Views ...................................................................... 6-8
6.1.3 Method Units .......................................................................6-10
6.2 Creating a New Method....................................................................... 6-11
6.2.1 Displaying the Method Editor ..............................................6-12
6.2.2 Selecting a Configuration ....................................................6-13
6.2.3 Specifying General Settings ................................................6-15
6.2.4 Creating Separation Blocks .................................................6-18
6.2.5 Creating Separation Block Segments ..................................6-19
6.2.5.1 Step Segments ..................................................6-20
6.2.5.2 Gradient Segments ............................................6-23
6.2.5.3 Purge Segments ................................................6-25
6.2.5.4 Inject Segments .................................................6-27
6.2.5.5 Autosampler Inject Segments ............................6-30
6.2.6 Adding Events .....................................................................6-33
6.2.7 Using the Blend Graph ........................................................6-51
6.2.8 Creating Prep Blocks ..........................................................6-53
6.2.9 Creating Prep Block Segments ...........................................6-57
6.2.9.1 Dilute Segments ................................................6-57
6.2.9.2 Combine Segments ...........................................6-61
6.2.9.3 Heat/Mix Segments ...........................................6-64
6.2.10 Specifying Data Storage Options .........................................6-67
6.2.11 Specifying Print Settings .....................................................6-69
6.2.12 Specifying Analysis and Printing After Run ..........................6-71
6.2.13 Saving Methods ..................................................................6-72
Table of Contents
BioCADĀ® 700E Workstation User Guide xv
6.3 Creating Typical Methods.................................................................... 6-73
6.3.1 Creating a Simple Method ...................................................6-73
6.3.2 Making Autoloader Injections in a Method ...........................6-77
6.3.3 Making Direct Autoloader Injections in a Method .................6-78
6.3.4 Making Manual Injections in a Method ................................6-79
6.3.5 Making Pump Injections in a Method ...................................6-80
6.3.6 Making Integrated Autosampler Injections in a Method .......6-82
6.3.7 Making Direct Wire Autosampler Injections in a Method ......6-83
6.4 Opening an Existing Method................................................................ 6-84
6.4.1 Opening a Method From a Method File ...............................6-84
6.4.2 Opening a Method From a Data File ...................................6-86
6.5 Editing a Method ................................................................................. 6-87
6.6 Running a Method............................................................................... 6-89
6.6.1 Loading a Configuration ......................................................6-89
6.6.2 Opening a Method ...............................................................6-90
6.6.3 Specifying Settings .............................................................6-90
6.6.4 Running a Method ...............................................................6-91
6.6.5 Stopping and Resuming a Method .......................................6-93
Chapter 7 Creating and Running Templates and
Multi-Methods
7.1 Creating and Running Templates.......................................................... 7-2
7.1.1 pH Map Template ................................................................. 7-5
7.1.1.1 Buffer/Solvent Requirements .............................. 7-6
7.1.1.2 Configuration Requirements ............................... 7-7
7.1.1.3 Method Requirements ........................................ 7-8
7.1.1.4 Creating and Running a pH Map Template ........7-12
7.1.2 Loading Study Template ......................................................7-14
7.1.3 Linear Gradient Template ....................................................7-16
7.1.4 Flow Rate Study Template ...................................................7-18
Table of Contents
xvi Applied Biosystems
7.1.5 Auto Cycling Template ........................................................7-19
7.1.6 Analysis Template (Integrated Autosampler) .......................7-21
7.1.6.1 Overview ...........................................................7-21
7.1.6.2 System and Method Requirements ....................7-23
7.1.6.3 Creating and Running ........................................7-24
7.1.6.4 Example Method for Analysis Template .............7-26
7.1.7 Analysis Template (Direct Wire Autosampler) ......................7-28
7.1.8 Step Optimization Template .................................................7-30
7.1.9 Combinatorial Optimization Template ..................................7-34
7.1.9.1 System and Method Requirements ....................7-35
7.1.9.2 Creating and Running ........................................7-36
7.2 Creating and Running Multi-Methods................................................... 7-40
7.2.1 Opening an Existing Multi-Method File ................................7-40
7.2.2 Creating a New Multi-Method File .......................................7-41
7.2.3 Adding Methods to a Multi-Method ......................................7-41
7.2.3.1 Using the Multi-Method Button to Add
Methods to a Multi-Method ................................7-42
7.2.3.2 Using Edit Multi-Method to Add Methods to
a Multi-Method ..................................................7-44
7.2.4 Running a Multi-Method ......................................................7-46
Chapter 8 Viewing Results and Checking Status
8.1 Using the Method Queue...................................................................... 8-2
8.2 Using the Status Window...................................................................... 8-4
8.3 Using the Strip Chart Recorder............................................................. 8-7
8.4 Using the Timer................................................................................... 8-14
8.5 Using the Event Log............................................................................ 8-15
Table of Contents
BioCADĀ® 700E Workstation User Guide xvii
Chapter 9 Maintenance
9.1 Maintenance Overview......................................................................... 9-2
9.2 Maintenance Schedule......................................................................... 9-3
9.3 General Maintenance ........................................................................... 9-5
9.3.1 Replacing the Main Power Fuse ........................................... 9-5
9.3.2 Cleaning the Fan Filter ......................................................... 9-7
9.4 UV/Vis Detector Maintenance............................................................... 9-8
9.4.1 Changing the UV/Vis Detector Lamps .................................. 9-8
9.4.2 Cleaning the UV/Vis Detector Flow Cell ..............................9-12
9.4.3 Changing the UV/Vis Detector Flow Cell .............................9-13
9.5 pH and Conductivity Monitor Maintenance........................................... 9-16
9.5.1 Cleaning the pH Probe and Cell ..........................................9-16
9.5.2 Calibrating the pH Probe .....................................................9-19
9.5.3 Storing the pH Probe ...........................................................9-21
9.5.4 Calibrating the Conductivity Monitor ....................................9-21
9.6 Pump Maintenance.............................................................................. 9-23
9.6.1 Replacing the Pump Seals and Cleaning the Pistons
and Pump Head ..................................................................9-23
9.6.2 Cleaning the Check Valves .................................................9-30
9.6.3 Cleaning the Filter Frit .........................................................9-33
9.7 Autoloader Maintenance...................................................................... 9-34
9.8 Valve Maintenance .............................................................................. 9-37
9.9 Autosampler Maintenance................................................................... 9-38
9.9.1 Cleaning and Replacing the Autosampler Needle ................9-38
9.9.2 Adjusting the Needle Height ................................................9-42
9.9.3 Cleaning the Sample Tray Area ...........................................9-45
9.9.4 Cleaning the Autosampler Rails and Roller .........................9-46
9.10 Hard Disk Maintenance ....................................................................... 9-47
9.10.1 Backing Up and Archiving Data ...........................................9-48
9.10.2 Testing Hard Disk Integrity ..................................................9-50
9.10.3 Defragmenting the Hard Disk ..............................................9-51
9.11 Long Term Shutdown........................................................................... 9-52
Table of Contents
xviii Applied Biosystems
Chapter 10 Troubleshooting and Error Codes
10.1 Troubleshooting................................................................................... 10-2
10.1.1 System Troubleshooting ......................................................10-3
10.1.2 Control Panel Troubleshooting ..........................................10-12
10.1.3 Status Window Troubleshooting ........................................10-15
10.1.4 Strip Chart Recorder Troubleshooting ...............................10-15
10.1.5 Fraction Collector Troubleshooting ....................................10-18
10.1.6 Integrated Autosampler (AS 3500) Troubleshooting ..........10-20
10.1.7 Sample Table Troubleshooting ..........................................10-28
10.1.8 Method Editor Troubleshooting .........................................10-29
10.1.9 Templates Troubleshooting ...............................................10-35
10.1.10 Computer Troubleshooting ................................................10-36
10.2 Error Codes....................................................................................... 10-37
10.2.1 File Error Codes ................................................................10-38
10.2.2 Blend Error Codes ............................................................10-41
10.2.3 Hardware Error Codes ......................................................10-42
10.2.4 Resource/Memory Error Codes .........................................10-43
10.2.5 Configuration Error Codes .................................................10-45
10.2.6 Autoloader Error Codes ....................................................10-48
10.2.7 Autosampler (AS 3500) Error Codes .................................10-48
10.2.8 Sample Table Error Codes ................................................10-50
10.2.9 Syringe Pump Error Codes ...............................................10-53
10.2.10 Detector Error Codes ........................................................10-56
10.2.11 Method Error Codes ..........................................................10-60
10.2.12 Supervisor Option Error Codes .........................................10-64
10.2.13 Program Loading Error Codes ...........................................10-65
10.2.14 Communication Error Codes .............................................10-66
10.2.15 COM Port Error Codes ......................................................10-68
Table of Contents
BioCADĀ® 700E Workstation User Guide xix
Appendix A Specifications.............................................................. A-1
Appendix B Spare Parts..................................................................... B-1
Appendix C Warranty/Service Information ........................... C-1
Appendix D BioCAD 700E Sample Methods ........................ D-1
Appendix E External Instrument Connections................... E-1
Appendix F Autosampler Injection Types.............................. F-1
Appendix G Maintenance Log ....................................................... G-1
Appendix H Autoloader Flow Path............................................. H-1
Glossary
Index
Table of Contents
xx Applied Biosystems
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456
  • Page 457 457
  • Page 458 458
  • Page 459 459
  • Page 460 460
  • Page 461 461
  • Page 462 462
  • Page 463 463
  • Page 464 464
  • Page 465 465
  • Page 466 466
  • Page 467 467
  • Page 468 468
  • Page 469 469
  • Page 470 470
  • Page 471 471
  • Page 472 472
  • Page 473 473
  • Page 474 474
  • Page 475 475
  • Page 476 476
  • Page 477 477
  • Page 478 478
  • Page 479 479
  • Page 480 480
  • Page 481 481
  • Page 482 482
  • Page 483 483
  • Page 484 484
  • Page 485 485
  • Page 486 486
  • Page 487 487
  • Page 488 488
  • Page 489 489
  • Page 490 490
  • Page 491 491
  • Page 492 492
  • Page 493 493
  • Page 494 494
  • Page 495 495
  • Page 496 496
  • Page 497 497
  • Page 498 498
  • Page 499 499
  • Page 500 500
  • Page 501 501
  • Page 502 502
  • Page 503 503
  • Page 504 504
  • Page 505 505
  • Page 506 506
  • Page 507 507
  • Page 508 508
  • Page 509 509
  • Page 510 510
  • Page 511 511
  • Page 512 512
  • Page 513 513
  • Page 514 514
  • Page 515 515
  • Page 516 516
  • Page 517 517
  • Page 518 518
  • Page 519 519
  • Page 520 520
  • Page 521 521
  • Page 522 522
  • Page 523 523
  • Page 524 524
  • Page 525 525
  • Page 526 526
  • Page 527 527
  • Page 528 528
  • Page 529 529
  • Page 530 530
  • Page 531 531
  • Page 532 532
  • Page 533 533
  • Page 534 534
  • Page 535 535
  • Page 536 536
  • Page 537 537
  • Page 538 538
  • Page 539 539
  • Page 540 540
  • Page 541 541
  • Page 542 542
  • Page 543 543
  • Page 544 544
  • Page 545 545
  • Page 546 546
  • Page 547 547
  • Page 548 548
  • Page 549 549
  • Page 550 550
  • Page 551 551
  • Page 552 552
  • Page 553 553
  • Page 554 554
  • Page 555 555
  • Page 556 556
  • Page 557 557
  • Page 558 558
  • Page 559 559
  • Page 560 560
  • Page 561 561
  • Page 562 562
  • Page 563 563
  • Page 564 564
  • Page 565 565
  • Page 566 566
  • Page 567 567
  • Page 568 568
  • Page 569 569
  • Page 570 570
  • Page 571 571
  • Page 572 572
  • Page 573 573
  • Page 574 574
  • Page 575 575
  • Page 576 576
  • Page 577 577
  • Page 578 578
  • Page 579 579
  • Page 580 580
  • Page 581 581
  • Page 582 582
  • Page 583 583
  • Page 584 584
  • Page 585 585
  • Page 586 586
  • Page 587 587
  • Page 588 588
  • Page 589 589
  • Page 590 590
  • Page 591 591
  • Page 592 592
  • Page 593 593
  • Page 594 594
  • Page 595 595
  • Page 596 596
  • Page 597 597
  • Page 598 598
  • Page 599 599
  • Page 600 600
  • Page 601 601
  • Page 602 602
  • Page 603 603
  • Page 604 604
  • Page 605 605
  • Page 606 606
  • Page 607 607
  • Page 608 608
  • Page 609 609
  • Page 610 610
  • Page 611 611
  • Page 612 612
  • Page 613 613
  • Page 614 614
  • Page 615 615
  • Page 616 616
  • Page 617 617
  • Page 618 618
  • Page 619 619
  • Page 620 620
  • Page 621 621
  • Page 622 622
  • Page 623 623
  • Page 624 624
  • Page 625 625
  • Page 626 626
  • Page 627 627
  • Page 628 628
  • Page 629 629
  • Page 630 630
  • Page 631 631
  • Page 632 632
  • Page 633 633
  • Page 634 634
  • Page 635 635
  • Page 636 636
  • Page 637 637
  • Page 638 638
  • Page 639 639
  • Page 640 640
  • Page 641 641
  • Page 642 642
  • Page 643 643
  • Page 644 644
  • Page 645 645
  • Page 646 646
  • Page 647 647
  • Page 648 648
  • Page 649 649
  • Page 650 650
  • Page 651 651
  • Page 652 652
  • Page 653 653
  • Page 654 654
  • Page 655 655
  • Page 656 656
  • Page 657 657
  • Page 658 658
  • Page 659 659
  • Page 660 660
  • Page 661 661
  • Page 662 662
  • Page 663 663
  • Page 664 664
  • Page 665 665
  • Page 666 666
  • Page 667 667

Thermo Fisher Scientific BioCAD® 700E Workstation User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI