American Standard 3697001.020 User manual

Type
User manual

This manual is also suitable for

M79
© 2011 AS America Inc.
Rev.11/11
PRIOLO
®
FloWise
®
16-1/2" HEIGHT
ELONGATED FLUSHOMETER TOILET
VITREOUS CHINA with EVERCLEAN
®
PRIOLO FloWise
®
16-1/2" HEIGHT
ELONGATED TOILET with EVERCLEAN
®
• Floormountelongatedrearoutletushometer
valvetoilet
• Vitreouschina
• HighEfficiency,LowConsumption.Operatesin
therangeof1.1gpfto1.6gpf(4.2Lpfto6.0Lpf)
• MeetsdenitionofHET(HighEfficiencyToilet)
whenusedwithahighefficiencyushvalve
(1.28gpfor1.6/1.1gpfdualush)
• PermanentEverClean
®
surfaceinhibitsthegrowth
ofstain-andodor-causingbacteria,mold,and
mildewonthesurface
• 16-1/2"rimheightforaccessibleapplication
• Condensationchannel
• Powerfuldirect-fedsiphonjetaction
• Fullyglazed2-1/8"trapway
• 1-1/2"inletspud
• 2boltcaps
• 100%factoryushtested
3695.001Elongatedbowlonly,topspud
3696.001Elongatedbowlonly,topspudwith
slottedrimforbedpanholding(Whiteonly)
3697.001Elongatedbowlonly,backspud
System MaP* Score:
1,000gramsofmiso@1.6gpfor1.28gpfwhen
usedwithanAmericanStandardushvalve
* MaximumPerformance(MaP)testingperformedbyIAPMO
R&TLab.MaPReportconductedbyVeritecConsulting,Inc.
andKoellerandCompany.
Component Parts:
047007-0070AInletspud(furnishedwithbowl)
481310.XXX0ABoltcapswithretainers
(furnishedwithbowl)
Nominal Dimensions:
752x356x419mm
(29-5/8"x14"x16-1/2")
Recommendedworkingpressurebetween
25psiatvalvewhenushingand80psistatic
Fixtureonly,lessseatandushometervalve
Compliance Certications -
Meets or Exceeds the Following Specications:
•ASMEA112.19.2-2008/CSAB45.1-08forVitreous
ChinaFixtures
SEEREVERSEFORROUGHING-INDIMENSIONS
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES - CHECK LOCAL CODES.
When installed so top of seat is 432 to 483mm (17" to 19") from the
finished floor.
BARRIER FREE
To Be Specied:
Color:WhiteBoneLinen
Seat:
AmericanStandard#5901.110Heavydutyopen
frontlesscoverwithEverClean
®
surface
AmericanStandard#5905.110Extraheavyduty
openfrontlesscoverwithEverClean
®
surface
AlternativeSeat:
FlushometerValve:
1.6gpf:
Sensor-Operated:AmericanStandardSelectronic
®
DCPower#6065.161.002(TopSpud)
Sensor-Operated:AmericanStandardSelectronic
®
ACPower#6067.262.002(BackSpud)
Manual:AmericanStandard#6047.161.002
(TopSpud)
1.28gpf:
Sensor-Operated:AmericanStandardSelectronic
®
DCPower#6065.121.002(TopSpud)
Sensor-Operated:AmericanStandardSelectronic
®
ACPower#6067.222.002(BackSpud)
Manual:AmericanStandard#6047.121.002
(TopSpud)
1.6/1/1gpfDualFlush:
Sensor-Operated:AmericanStandardSelectronic
®
DCPower#6065.761.002(TopSpud)
M80
© 2011 AS America Inc.
BARRIER FREE
PRIOLO
®
FloWise
®
16-1/2" HEIGHT
ELONGATED FLUSHOMETER TOILET
VITREOUS CHINA with EVERCLEAN
®
711mm
(28
")
121mm
(4-3/4
")
240mm
(9-1/2
")
152mm
(6
")
102mm
(4
")
419mm
(16-1/2")
470mm
(18-1/2
")
356mm
(14
")
13mm
(1/2
")
345mm
(13-5/8
")
646mm
(25-3/8
")
60mm
(2-3/8")
136mm
(5-3/8")
752mm
(29-5/8")
C/L OF SEAT POST HOLES
140mm (5-1/2
") CENTERS
FINISHED WALL
1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE
(SUGGESTED)
C/L OF 1/2"
DIA. HOLES
1-1/2"
SPUD
FINISHED
FLOOR
13mm x 25mm
slots
(1/2" x 1")
217mm
(8-1/2
")
102mm
(4
")
C/L OF
WASTE
OUTLET
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
NOTES:
PRODUCTS3695SHOWN,3696SAMEASEXCEPTWITHSLOTTEDRIM
FORBEDPANHOLDING.
TOCOMPLYWITHAREACODEGOVERNINGTHEHEIGHTOFVACUUM
BREAKERONTHEFLUSHOMETERVALVE,THEPLUMBERMUST
VERIFY DIMENSIONSSHOWNFORSUPPLYROUGHING.
FLUSHOMETERVALVENOTINCLUDEDWITHFIXTUREANDMUSTBE
ORDEREDSEPARATELY.FLUSHOMETERVALVEREQUIREMENTSFOR
12"(305MM)ROUGH-IN:SWEATEXTENSIONNIPPLEISREQUIRED.
REFERTOVALVEMANUFACTURERANDLOCALCODES.
IMPORTANT:Dimensionsofxturesarenominalandmayvarywithin
therangeoftolerancesestablishedbyANSIStandardA112.19.2.These
measurementsaresubjecttochangeorcancellation.Noresponsibilityis
assumedforuseofsupersededorvoidedpages.
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
240mm
(9-1/2
")
419mm
(16-1/2
")
438mm
(17-1/4
")
356mm
(14
")
470mm
(18-1/2
")
217mm
(8-1/2
")
102mm
(4
"
)
112mm
(4-3/8
")
752mm
(29-5/8
")
C/L OF SEAT POST HOLES
140mm (5-1/2
") CENTERS
FINISHED WALL
C/L OF
WASTE
OUTLET
152mm
(6
")
102mm
(4
")
FINISHED
FLOOR
13mm
(1/2
")
13mm x 25mm
slots
(1/2
" x 1")
345mm
(13-5/8
")
646mm
(25-3/8
")
C/L OF 1/2
DIA. HOLES
3695.001/3696.001
3697.001
Rev.11/11
  • Page 1 1
  • Page 2 2

American Standard 3697001.020 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI