American Standard 3696001.020, 3697001.020 User manual

  • Hello! I am an AI chatbot trained to assist you with the American Standard 3696001.020 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
M79
© 2011 AS America Inc.
Rev.11/11
PRIOLO
®
FloWise
®
16-1/2" HEIGHT
ELONGATED FLUSHOMETER TOILET
VITREOUS CHINA with EVERCLEAN
®
PRIOLO FloWise
®
16-1/2" HEIGHT
ELONGATED TOILET with EVERCLEAN
®
• Floormountelongatedrearoutletushometer
valvetoilet
• Vitreouschina
• HighEfficiency,LowConsumption.Operatesin
therangeof1.1gpfto1.6gpf(4.2Lpfto6.0Lpf)
• MeetsdenitionofHET(HighEfficiencyToilet)
whenusedwithahighefficiencyushvalve
(1.28gpfor1.6/1.1gpfdualush)
• PermanentEverClean
®
surfaceinhibitsthegrowth
ofstain-andodor-causingbacteria,mold,and
mildewonthesurface
• 16-1/2"rimheightforaccessibleapplication
• Condensationchannel
• Powerfuldirect-fedsiphonjetaction
• Fullyglazed2-1/8"trapway
• 1-1/2"inletspud
• 2boltcaps
• 100%factoryushtested
3695.001Elongatedbowlonly,topspud
3696.001Elongatedbowlonly,topspudwith
slottedrimforbedpanholding(Whiteonly)
3697.001Elongatedbowlonly,backspud
System MaP* Score:
1,000gramsofmiso@1.6gpfor1.28gpfwhen
usedwithanAmericanStandardushvalve
* MaximumPerformance(MaP)testingperformedbyIAPMO
R&TLab.MaPReportconductedbyVeritecConsulting,Inc.
andKoellerandCompany.
Component Parts:
047007-0070AInletspud(furnishedwithbowl)
481310.XXX0ABoltcapswithretainers
(furnishedwithbowl)
Nominal Dimensions:
752x356x419mm
(29-5/8"x14"x16-1/2")
Recommendedworkingpressurebetween
25psiatvalvewhenushingand80psistatic
Fixtureonly,lessseatandushometervalve
Compliance Certications -
Meets or Exceeds the Following Specications:
•ASMEA112.19.2-2008/CSAB45.1-08forVitreous
ChinaFixtures
SEEREVERSEFORROUGHING-INDIMENSIONS
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES - CHECK LOCAL CODES.
When installed so top of seat is 432 to 483mm (17" to 19") from the
finished floor.
BARRIER FREE
To Be Specied:
Color:WhiteBoneLinen
Seat:
AmericanStandard#5901.110Heavydutyopen
frontlesscoverwithEverClean
®
surface
AmericanStandard#5905.110Extraheavyduty
openfrontlesscoverwithEverClean
®
surface
AlternativeSeat:
FlushometerValve:
1.6gpf:
Sensor-Operated:AmericanStandardSelectronic
®
DCPower#6065.161.002(TopSpud)
Sensor-Operated:AmericanStandardSelectronic
®
ACPower#6067.262.002(BackSpud)
Manual:AmericanStandard#6047.161.002
(TopSpud)
1.28gpf:
Sensor-Operated:AmericanStandardSelectronic
®
DCPower#6065.121.002(TopSpud)
Sensor-Operated:AmericanStandardSelectronic
®
ACPower#6067.222.002(BackSpud)
Manual:AmericanStandard#6047.121.002
(TopSpud)
1.6/1/1gpfDualFlush:
Sensor-Operated:AmericanStandardSelectronic
®
DCPower#6065.761.002(TopSpud)
M80
© 2011 AS America Inc.
BARRIER FREE
PRIOLO
®
FloWise
®
16-1/2" HEIGHT
ELONGATED FLUSHOMETER TOILET
VITREOUS CHINA with EVERCLEAN
®
711mm
(28
")
121mm
(4-3/4
")
240mm
(9-1/2
")
152mm
(6
")
102mm
(4
")
419mm
(16-1/2")
470mm
(18-1/2
")
356mm
(14
")
13mm
(1/2
")
345mm
(13-5/8
")
646mm
(25-3/8
")
60mm
(2-3/8")
136mm
(5-3/8")
752mm
(29-5/8")
C/L OF SEAT POST HOLES
140mm (5-1/2
") CENTERS
FINISHED WALL
1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE
(SUGGESTED)
C/L OF 1/2"
DIA. HOLES
1-1/2"
SPUD
FINISHED
FLOOR
13mm x 25mm
slots
(1/2" x 1")
217mm
(8-1/2
")
102mm
(4
")
C/L OF
WASTE
OUTLET
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
NOTES:
PRODUCTS3695SHOWN,3696SAMEASEXCEPTWITHSLOTTEDRIM
FORBEDPANHOLDING.
TOCOMPLYWITHAREACODEGOVERNINGTHEHEIGHTOFVACUUM
BREAKERONTHEFLUSHOMETERVALVE,THEPLUMBERMUST
VERIFY DIMENSIONSSHOWNFORSUPPLYROUGHING.
FLUSHOMETERVALVENOTINCLUDEDWITHFIXTUREANDMUSTBE
ORDEREDSEPARATELY.FLUSHOMETERVALVEREQUIREMENTSFOR
12"(305MM)ROUGH-IN:SWEATEXTENSIONNIPPLEISREQUIRED.
REFERTOVALVEMANUFACTURERANDLOCALCODES.
IMPORTANT:Dimensionsofxturesarenominalandmayvarywithin
therangeoftolerancesestablishedbyANSIStandardA112.19.2.These
measurementsaresubjecttochangeorcancellation.Noresponsibilityis
assumedforuseofsupersededorvoidedpages.
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
240mm
(9-1/2
")
419mm
(16-1/2
")
438mm
(17-1/4
")
356mm
(14
")
470mm
(18-1/2
")
217mm
(8-1/2
")
102mm
(4
"
)
112mm
(4-3/8
")
752mm
(29-5/8
")
C/L OF SEAT POST HOLES
140mm (5-1/2
") CENTERS
FINISHED WALL
C/L OF
WASTE
OUTLET
152mm
(6
")
102mm
(4
")
FINISHED
FLOOR
13mm
(1/2
")
13mm x 25mm
slots
(1/2
" x 1")
345mm
(13-5/8
")
646mm
(25-3/8
")
C/L OF 1/2
DIA. HOLES
3695.001/3696.001
3697.001
Rev.11/11
/