American Dynamics 1010 Series, 1010T Series Installation And Operating Instructions Manual

  • Hello! I am an AI chatbot trained to assist you with the American Dynamics 1010 Series Installation And Operating Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1010/T Series
Incandescent Illuminator
This manual describes the installation and operating procedures for the American Dynamics 1010/T Series Illuminator. Before
installation is started, become familiar with all the special features and warnings associated with this equipment. Once
installation is complete, store this manual in a safe, convenient location for future reference.
Installation and Operating Instructions
Table of Contents
Page
Description................................................................. 1
Features...................................................................... 1
General Safety.......................................................... 1
Installation................................................................ 2
Mounting........................................................ 2
Connection..................................................... 2
Twilight Switch.............................................. 2
Lens Selection................................................ 2
IR Illumination Area-vs-Distance.................. 2
Bulb Replacement.................................................... 3
Troubleshooting ....................................................... 4
Dimensions............................................................... 5
Specifications............................................................. Back Page
Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable. However, no responsibility is
assumed by AMERICAN DYNAMICS for its use; nor for any infringements of other rights of third parties which may result
from its use. No license is granted by implications or otherwise under any patent or patent rights of AMERICAN DYNAMICS.
1
DESCRIPTION
DESCRIPTION
The 1010T Series Infrared Illuminator provides outstanding
results when used with IR sensitive black/white cameras.
The light produced by the 1010T Series is invisible to the
human eye. This feature is excellent for covert security or
where the addition of visible lighting is not possible.
The 300 watt spot-lamp is designed to project a highly
concentrated IR beam to a distance of 460 feet (140 m),
covering an area 100 ft wide x 66 ft high. Pronounced ribbing
around the two-part black enameled housing dissipates heat to
extend bulb life.
The IR filter is a lamination of vaporized-metal coated glass
and Pyrex subjected to a special hardening process.
A 10 ft (3 m) pendant line cord is standard with the
Illuminator.
FEATURES
120 VAC Input
300 Watt Bulb
Weatherproof Housing
10 ft (3 m) Heavy Duty Pendant Line Cord
GENERAL SAFETY
Observe the following safety instructions without fail:
The 1010T generates large amounts of heat from the IR
lamp during operation. Determine that no systems
(sprinklers, thermostats, heating vents, etc.) in the
immediate installation area are triggered or damaged as a
result of this thermal radiation (heat).
Before performing any service on or around the 1010T, shut
down the Illuminator and isolate it electrically to prevent
accidental operation. A cool-off period of approximately
one hour is required after shut down. (Even if the housing
is cool, the IR lamp may still retain enough heat to cause
injury.)
Figure 1 - 1010T Infrared Illuminator
!
CAUTION
The concentrated high power of the Infrared beam
can cause serious damage to a person's vision!
Maintain a minimum 33 foot (10 m) safety zone
between the Illuminator and any human contact.
2
INSTALLATION
INSTALLATION
Mounting
The 1010T IR Illuminator is supplied with a "U-shaped"
bracket for mounting the Illuminator to a wall bracket or a
Pan/Tilt mechanism.
Ensure the structural soundness of the mounting bracket
support surface.
Three holes are drilled in the bottom of the mounting
bracket (see Figure 2):
Use the center hole (0.83"/21 mm) to secure the
1010T to a mounting bracket.
Use the two side holes (0.28"/7 mm) to secure the
1010T to a Pan/Tilt unit.
Connection
The 1010T requires a 120 VAC (2.5 Amps) supply voltage.
The 1010T is supplied with a 10 ft (3 m) pendant line cord for
connecting to a power supply (see Table 1).
Table 1 - 1010T Wiring Color Code
Leads Designation
Green Ground
White 120VAC Hot
Black 120VAC Neutral
Twilight Switch
Routing the supply voltage through a twilight switch (not
supplied) extends the operational life of the 1010T. American
Dynamic's recommends using one twilight switch (AD part
number 1010/TS) to operate a maximum of three Illuminator
units.
Lens Selection for 1010/T
Table 2 lists the minimum focal length lens size required to
focus at the maximum spotlight beam range for a particular
camera format.
Table 2 - Minimum Focal Length Lens Size
Maximum Range Camera Format
460 (feet) 1" 2/3" 1/2" 1/3"
Lens Size 75 mm 52 mm 37.5 mm 26 mm
IR Illuminated Area -vs- Distance
The beam transmitted by the 1010/T provides effective IR
illumination to 460 feet (140 meters). Table 3 lists the
spotlight area covered by the beam.
Table 3 - Distance -vs- Area Table
Distance* Area Covered
[Horiz x Vert]
50 ft (15.2 m) 11 x7 ft (3.3 x 2.1 m)
75 ft (22.3 m) 16 x 10 ft (4.9 x 3.1 m)
100 ft (30.5 m) 21 x 14 ft (6.4 x 4.3 m)
125 ft (38.1 m) 26 x 17 ft (7.9 x 5.2 m)
150 ft (45.7 m) 32 x 21 ft (9.8 x 6.4 m)
175 ft (53.3 m) 37 x 24 ft (11.3 x 7.3 m)
200 ft (61 m) 42 x 28 ft (12.8 x 8.5 m)
225 ft (68.6 m) 47 x 31 ft (14.3 x 9.5 m)
250 ft (76.2 m) 53 x 35 ft (16.2 x 10.7 m)
275 ft (83.8 m) 58 x 38 ft (17.7 x 11.6 m)
300 ft (91.4 m) 63 x 42 ft (19.2 x 12.8 m)
325 ft (99.1 m) 68 x 45 ft (20.7 x 13.7 m)
350 ft (106 m) 74 x 49 ft (22.6 x 14.9 m)
375 ft (114 m) 79 x 52 ft (24.1 x 15.9 m)
400 ft (122 m) 84 x 56 ft (25.6 x 17.1 m)
425 ft (130 m) 89 x 59 ft (27.2 x 18.0 m)
450 ft (137 m) 95 x 63 ft (29.0 x 19.2 m)
475 ft (145 m) 100 x 66 ft (30.5 x 20.1 m)
500 ft (152 m) 105 x 70 ft (32.0 x 21.4 m)
*Distances from light source to subject
0.28"/7 mm
0.83"/21 mm
4.25"/108 mm
2.75"/70 mm
0.56"/14.3 mm
Figure 2 - Mounting Bracket Drill Holes
3
BULB REPLACEMENT
BULB REPLACEMENT
Before servicing the Illuminator, power down the unit and
allow approximately one hour to cool. Replacement bulbs can
be ordered through American Dynamics (part #
AD1010/TBB). IR bulb replacement is done without
removing the Illuminator from its mount.
Remove the three 4 mm Hex screws holding the main
housing to the rear housing (see Figure 3).
Pull the defective IR bulb forward and gently remove the
power cord connector from the IR bulb prongs.
Remove and save the O-Ring (red colored gasket) around
the defective bulb.
Discard the defective bulb.
Fit the O-ring (red colored gasket) around the new IR bulb
and plug in the power cord connector taking care not to
crack the porcelain base of the connector.
Check that the IR bulb O-Ring is properly seated between
the new bulb and the rear housing. Refer to Figure 3.
Check that the weather seal (black colored gasket) is
properly seated in the rear housing outer rim.
Insert the IR lamp into the main housing.
Close the housing and secure the three 4 mm Hex screws.
Main Housing
Rear Housing
4mm
Hex
Screw
Replacement Bulb
Power Cord
w/Connector
O-Ring
Weather Seal
Figure 3 - Bulb Replacement
IF YOU ENCOUNTER ANY PROBLEMS
OPERATING THIS UNIT, OR NEED TECHNICAL
ASSISTANCE, CALL OUR TECHNICAL SUPPORT
CENTER AT:
within the United States: 1-800-442-2225
outside the United States: (914) 624-7640
PROBLEM POSSIBLE CAUSE SOLUTION
Lamp does not come on No 120 VAC to Lamp.................................... Check 120 VAC power
.................................... Check twilight switch operation (if used)
Bulb burned out ......................................... Check bulb connection socket
......................................... Replace bulb
Bulb burns out frequently Lamp operating during daylight hours.................. Install twilight switch
Moisture getting into housing............................ Check weatherseal
............................ Tighten the 3 housing screws
Poor image quality on Camera not sensing IR wavelengths.....................Check that camera is sensitive to IR light
video monitor
Camera does not resolve distant objects................. Poor connections causing low AC voltage
................. Bulb is near end of service life, replace bulb
4
TROUBLESHOOTING
!
!
CAUTION
Do not attempt to service an operational Illuminator!
The heat generated by the IR lamp is sufficient to cause SEVERE
BURNS. Before performing any service on or around the 1010T, shut
down the Illuminator and isolate it electrically to prevent accidental
starting. A cool-off period of approximately one hour is required after
shut down. (Even if the housing is cool, the IR lamp may still retain
enough heat to cause injury.)
!
!
CAUTION
Do not look directly into an operational Illuminator!
Since IR light is invisible to the human eye, the only method of verifying
a malfunctioning IR lamp is at the video output location. Before starting
any maintenance work on the 1010T, be certain that the video system (i.e.
cameras, monitors, etc.) is functioning properly.
5
DIMENSIONS
9.45"
240 mm
8.27"/210 mm 7.48"/190 mm
7.5"
190 mm
Figure 4- 1010/T Dimensions
SPECIFICATIONS
SPECIFICATIONS
Power: 300 Watt
Operating Voltage: 120 VAC
Current Consumption: 2.5 A
Infrared Wavelength: 850 nm
Beam Dispersion: 12° H x 8° V
Normal Light Range*: 460 ft/140 m
Weatherproof Standard: NEMA-4 (IP65)
Service Life (MTBF): >2000 Hours (Bulb)
Weight: 5.5 pound / 2.5 Kg
Dimensions: (9.45 H x 8.27 W x 7.48 D) inches
(240 H x 210 W x 190 D) mm
ACCESSORIES
AD1010/TBB: 300 watt, PAR 56, bulb
AD1010/TS: Dusk-to-dawn switch (will operate 3 units)
AD1050/PL: "L" Bracket - one IR Illuminator on Patriot Series Pan/Tilt
AD1050/PT: "T" Bracket - two IR Illuminators on Patriot Series Pan/Tilt
AD1050/HL: "L" Bracket - one IR Illuminator on Hercules Series Pan/Tilt
AD1050/HP: "T" Bracket - two IR Illuminators on Hercules Series Pan/Tilt
* Normal range is based on the use of a CCD camera with maximum IR-sensitivity, medium scene reflectance.
An American Dynamics Product
Designed and built by
Sensormatic CCTV Systems Division
One Blue Hill Plaza
Pearl River, New York, 10965
Business: (914) 624-7600
Technical Support Center: 1-800-442-2225
FAX: (914) 624-7685
OP1010T C Made in U.S.A.
April 1994
/