Adaptec ULTRAbloc 320 JBOD User guide

Type
User guide
User Guide
P/N: MAN-SC2100-001
Revision: 1.5
September 2003
ULTRAbloc 320 JBOD
Disclaimer
3
320 JBOD
Disclaimer and Warranty
Disclaimer
ADAPTEC, INC. reserves the right to make changes to this
manual and the equipment described herein without notice.
ADAPTEC has made all reasonable effort to insure that
the information in this manual is accurate and complete.
However, ADAPTEC shall not be liable for any technical
or editorial errors or omissions made herein or for
incidental, special, or consequential damage of whatsoever
nature resulting from the furnishing of this manual, or
operation and performance of equipment in connection with
this manual.
All Trademarks acknowledged.
Warranty
Basic Warranty - In the absence of any optional warranty
or continuing provisions by formal agreement, ADAPTEC
warrants its products in accordance with the schedules listed
below. Purchaser hereafter mentioned refers at all times to
the customer who purchased ADAPTEC product(s).
ULTRAbloc Warranty - Adaptec warrants ULTRAbloc
products of its manufacture to be free from defect in
material and workmanship for a period of three (3) years
from the date of shipment. During this period, if the
customer experiences difficulties with a ADAPTEC
ULTRAbloc system and is unable to resolve the problem via
phone with ADAPTEC Technical Support a Return
Material Authorization (RMA) number will be issued for the
faulty component. Following receipt of an RMA, the
Purchaser is responsible for returning the product to
Warranty
4
320 JBOD
ADAPTEC, freight prepaid. ADAPTEC, upon verifi-
cation of warranty, will repair or replace at its option the
ULTRAbloc component in question, and will then return the
product to the Purchaser, freight prepaid.
Cable Warranty - All ADAPTEC provided cables are
warranted for ninety (90) days from the time of shipment.
Questionable cables should be returned to ADAPTEC,
freight prepaid where they will be repaired or replaced by
ADAPTEC at its option and returned to the Purchaser,
freight prepaid.
General Terms - The above warranties shall not apply to
expendable components such as fuses, bulbs, and the like,
nor to connectors, adapters, and other items not a part of the
basic product. ADAPTEC shall have no obligation to
make repairs or to cause replacement required through
normal wear and tear or necessitated in whole or in part by
catastrophe, fault or negligence of the user, improper or
unauthorized use of the product, or use of the product in
such a manner for which it was not designed, or by causes
external to the product, such as, but not limited to, power
failure or air conditioning. The ADAPTEC sole obligation
hereunder shall be to repair or replace any defective product,
and unless stated, pay return transportation costs for such
replacement. Purchaser shall provide labor for removal of
the defective product, shipping charges for return to
ADAPTEC and installation of its replacement. On-site
services are not a part of this warranty. Above warranties are
subject to change without notice.
Warranty
5
320 JBOD
Returned Material - Warranty claims must be received by
ADAPTEC within the applicable warranty period. A
replaced product, or part thereof, shall become the property
of ADAPTEC and shall be returned to ADAPTEC at
Purchaser’s expense. All returned material must be accom-
panied by a Return Materials Authorization (RMA) number
assigned by ADAPTEC. More information is available on
our web site (http://www.adaptec.com/support).
For RMA numbers contact ADAPTEC Customer Support
Monday-Friday 3am to 5pm Pacific at:
Telephone: 321-207-2000 (RAID, FC, External Storage)
408-934-7274 (Hardware)
email: ask.adaptec.com
WWW: http://www.adaptec.com/support
Warranty
6
320 JBOD
THE EXPRESSED WARRANTIES SET FORTH IN THIS
AGREEMENT ARE IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WITHOUT LIMITATION, ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, AND ALL SUCH OTHER WARRANTIES ARE
HEREBY DISCLAIMED AND EXCLUDED BY
ADAPTEC. THESE STANDARD EXPRESS
WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR
LIABILITIES ON THE PART OF ADAPTEC FOR
DAMAGES, INCLUDING BUT NOT LIMITED TO
SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH THE USE
OR PERFORMANCE OF THE PRODUCT.
7
320 JBOD
Table of Contents
Disclaimer.................................................................................................. 3
Warranty .................................................................................................... 3
Preface ..................................................................................................11
Audience.................................................................................................. 11
Conventions Used In This User Guide .................................................... 12
Getting Support........................................................................................ 12
FCC Statement......................................................................................... 13
European Community Statement............................................................. 13
VCCI................................................................................................ 14
BSMI ............................................................................................... 14
Safety Statements..................................................................................... 15
Chapter 1: Introduction .................................................................... 17
About the ULTRAbloc Series Storage Array.......................................... 17
Features.................................................................................................... 17
Disk Drive Carrier........................................................................... 18
Power Supplies................................................................................ 18
Cooling System ............................................................................... 18
I/O Modules............................................................................................. 20
Enclosure Services Module ESM.................................................... 20
Concentrator Services Module........................................................ 20
Terminating Services Module ......................................................... 21
Terminator Module (TM)................................................................ 21
Joiner module (JM).......................................................................... 21
Products Covered by this User Guide...................................................... 22
8
320 JBOD
Chapter 2: Installation ...................................................................... 23
Safety Statements..................................................................................... 24
Unpacking and Initial Setup .................................................................... 26
Installing the System in an Equipment Rack........................................... 26
Ambient Temperature...................................................................... 26
Air Flow........................................................................................... 27
Mechanical Loading........................................................................ 27
Electrical Considerations......................................................................... 28
Circuit Overloading......................................................................... 28
Chapter 3: Cabling and Configuration ............................................29
ULTRAbloc Series SCSI ID Assignments.............................................. 29
I/O Module LEDs .................................................................................... 30
ESM/CSM LEDs............................................................................. 30
TSM LED........................................................................................ 30
Cabling The ULTRAbloc Series Enclosure............................................. 31
Single ESM and TSM Configuration....................................................... 31
Cabling the Single (Joined) SCSI Bus Configuration..................... 31
Cabling the Dual (split) SCSI Bus Configuration........................... 33
Single CSM and TSM Configuration ...................................................... 35
Cabling the Single (Joined) SCSI Bus Configuration..................... 35
Cabling the Dual (split) SCSI Bus Configuration........................... 37
Single Cluster Configuration................................................................... 39
Dual CSM Configuration......................................................................... 41
Dual Concentrator Services Modules.............................................. 41
Join/Split Bus Jumper.............................................................................. 43
Powering On the ULTRAbloc Series Enclosure ..................................... 44
ULTRAbloc Series Jumper Settings ............................................... 44
9
320 JBOD
Powering on an AC enclosure......................................................... 45
Windows 2000 Device Driver for ULTRAbloc Series............................ 46
Installing the Windows 2000 Device Driver................................... 46
Chapter 4: System Monitoring .........................................................47
Overview.................................................................................................. 47
Environmental Status (ES) Block............................................................ 48
Environmental Status (ES) Block Features..................................... 49
Alarm Buzzer Mute ................................................................................. 49
Enclosure Front Panel LEDs.................................................................... 50
Disk Drive Carrier LEDs......................................................................... 51
Power Supply LEDs................................................................................. 53
Advanced Cooling Module (ACM) LEDs............................................... 54
Chapter 5: Installing and Removing Components .........................55
Location of the Components.................................................................... 56
Installing and Removing a Disk Drive Carrier........................................ 57
Installing a Disk Drive Carrier ........................................................ 57
Removing a Disk Drive Carrier....................................................... 57
Installing and Removing a Power Supply................................................ 59
Installing a Power Supply................................................................ 59
Removing a Power Supply.............................................................. 59
Installing and Removing an Advanced Cooling Module......................... 60
Installing an Advanced Cooling Module......................................... 60
Removing an Advanced Cooling Module....................................... 60
Installing and Removing an I/O Option Module..................................... 61
Installing an I/O Option Module ..................................................... 61
Removing an I/O Option Module.................................................... 61
10
320 JBOD
Appendix A: Technical Specifications ..............................................63
System...................................................................................................... 63
Redundant Components........................................................................... 63
Hot Swappable Components.................................................................... 63
Cable Lengths Supported......................................................................... 63
Physical Dimensions................................................................................ 64
Deskside Enclosure ......................................................................... 64
Rack Enclosure................................................................................ 64
Warranty .................................................................................................. 64
Monitoring............................................................................................... 64
Disk Drives .............................................................................................. 64
Power Supply........................................................................................... 65
AC Power Supply Input................................................................... 65
Temperature............................................................................................. 65
Humidity.................................................................................................. 65
Altitude .................................................................................................... 65
Operational Shock.................................................................................... 66
Operational Vibration.............................................................................. 66
Regulatory and Agency Approvals.......................................................... 66
Safety............................................................................................... 66
Standards ......................................................................................... 66
EMC ................................................................................................ 66
Appendix B: Safety Statement Translations ....................................67
Audience
11
320 JBOD
Preface
This User Guide describes the installation and operation of
the ULTRAbloc Series. The following products are covered:
Audience
This User Guide is intended for use by the person
installing and operating the ULTRAbloc Series. This User
Guide describes the operation of the ULTRAbloc Series
only. For details relating to the host system, refer to the
documentation supplied with the host system.
SC2100ETT-AC SC2100ETR-AC
SC2100ERR-AC SC2100EJT-AC
SC2100CCR-AC SC2100EJR-AC
SC2101CCR-AC
Conventions Used In This User Guide
12
320 JBOD
Conventions Used In This User Guide
The following conventions are used throughout this User
Guide.
Note: A NOTE gives general information, such as helpful tips
and references to related information.
CAUTION: A CAUTION means take care. There is a risk of caus-
ing damage to the equipment or losing data.
WARNING: A WARNING means beware. There is a risk of elec-
tric shock or personal injury. Before working on the enclosure be
aware of the hazards that exist.
Getting Support
If you are having difficulties installing or operating your
ULTRAbloc Series you can contact our World Wide Support
Centre for assistance Monday-Friday 3am to 5pm Pacific at:
Telephone: 321-207-2000 (RAID, FC, External Storage)
408-934-7274 (Hardware)
email: ask.adaptec.com
WWW http://www.adaptec.com/support
FCC Statement
13
320 JBOD
FCC Statement
WARNING: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with
the limits for a class A digital device, pursuant to Part 15 of
the FCC Rules.
These limits are designed to provide reasonable protection
against harmful interference when operated in a commercial
environment.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accor-
dance with the instruction manual, may cause harmful inter-
ference to radio communications.
Operation of this equipment in a residential area is likely
to cause harmful interference, in which case, the user will be
required to correct the interference at his own expense.
Any changes or modifications to this equipment not
expressly approved by Eurologic Systems Ltd. could void
the user’s authority to operate this equipment.
European Community Statement
This equipment complies with the following European
directives:
EMC Directive 89/336/EEC and amending Directives 92/31/
EEC and 93/68/EEC.
Low Voltage Directive 73/23/EEC and amending Directive 93/
68/EEC.
European Community Statement
14
320 JBOD
This Class A digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe A est conforme à la
norme NMB-003 du Canada.
VCCI
English Translation:
This is a Class A product based on the standard of the
Voluntary Control Council for Interference by Information
Technology Equipment. If this equipment is used in a
domestic environment, radio disturbance may arise. When
such trouble occurs, the user may be required to take
corrective actions.
BSMI
English Translation:
This is a Class A product. In a domestic environment this
product may cause radio interference, in which case the user
may be required to take adequate measures.
Safety Statements
15
320 JBOD
Safety Statements
The following safety statements must be read before insta-
lation. For language translations of these statements refer to
Appendix B.
CAUTION: This equipment is intended only for installation in a
restricted access location.
CAUTION: Allow disk drives and power supplies to reach room
ambient temperature before powering on the system.
CAUTION: It is recommended that if interconnecting equipment
resides within more than one equipment rack cabinet, these cabi-
nets should be at the same ground potential.
CAUTION: Before attempting to install or remove any of the com-
ponents, ensure that anti-static precautions have been taken. The
minimum requirement is an anti-static wrist strap and grounding
wire.
CAUTION: When installing or removing a rackmount shelf,
remove all power supplies and disk drives. It is recommended that
you work with at least one other person. This is necessary to pre-
vent personal injury and damage to the shelf.
Safety Statements
16
320 JBOD
CAUTION: After removing a Module the resulting hole must be
blocked, by installing a blanking plate or by installing a replace-
ment Module. Failure to do so can disrupt air flow and seriously
reduce cooling.
WARNING: A possible shock hazard may exist in the area of the
fan connection.
WARNING: Disconnect both power supply inlets before opening
this equipment for servicing.
WARNING: The module handles are to facilitate the easy inser-
tion and removal of the modules, they should not be used to lift
and/or carry the enclosure.
About the ULTRAbloc Series Storage Array
17
320 JBOD
Chapter 1: Introduction
This Chapter introduces the ULTRAbloc Series of Storage
Arrays. The main features are described along with a list of
the options and configurations that are available.
About the ULTRAbloc Series Storage Array
The ULTRAbloc Series is a new concept in data storage that
provides the optimum in investment protection and versatil-
ity. The ULTRAbloc Series will meet the performance,
capacity, and high availability needs of the widest variety of
applications, such as video, imaging, prepress, data ware-
house, OLTP, and web servers.
Features
Fourteen disk drive slots.
Redundant AC power supplies.
Redundant input power cords.
A total of four fans in two Advanced Cooling Modules (ACM)
providing n+1 redundancy on fans.
Two rear removable I/O option modules provide active/passive
failure redundancy on environmental monitoring, or per Bus
Monitoring.
Multi-MODE SCSI Interface Ultra 320, Ultra 160, Ultra-2
LVD SCSI.
Hot plug of power supplies and ACM’s.
Maximum configurations of drives supported with one or two
power supplies.
Failure indication of all Field Replaceable Units (FRU) via
LEDs and audible alarm (with alarm mute button).
Disk drive hot plug support.
Auto-sense termination at end of bus (busses) if no cable
present.
Auto bus split if two cables present.
Features
18
320 JBOD
Up to 10M of LVD SCSI cable.
SCSI I.D.’s hard-wired.
Global remote spinup enable capability.
Global delayed spinup enable capability.
Rail Kit mounting option for 19” and 23” equipment racks.
Floor mount desk side option (tower).
Carrier cam lever allows controlled insertion and extraction of
disk carriers.
Disk Drive Carrier The disk drive carrier supports a one inch disk drive with
support for 10K RPM drives and higher (15K). The
ULTRAbloc Series enclosure holds up to fourteen disk drive
carriers. The disk drives can be hot swapped and the disk
drive carriers provide for blind mating.
Power Supplies The ULTRAbloc Series uses two AC power supplies for
normal operation, providing redundancy of the power
system. The power supplies can be hot swapped. The power
supplies provide 673 Watts continuous output power and 853
Watts peak output power. The power supplies provide active
current sharing, power factor correction, over current and
over voltage protection is also provided. The power supplies
have individual power inputs.
Cooling System Cooling is provided by the two Advanced Cooling
Modules (ACMs) located at the rear of the enclosure. Each
of the ACM units contain two variable speed fans. The
enclosure requires four fans for normal operation, but will
operate correctly with one fan failed (redundancy is lost if
one fan is failed in either ACM), however, it is recom-
mended that the failed fan be replaced as soon as possible.
The ACM units can be hot swapped. The I/O Option Module
Features
19
320 JBOD
(ESM and TSM described later) monitors and controls the
speed of each fan. The speed is set depending on the ambient
temperature and failed status. The fans are set to full speed
if one fan is failed. The following table shows how the fan
speed relates to temperature change.
Note: All fans are set to the same speed.
Table 1-1Fan Speed vs. Temperature Change
ACM Speed
Ambient Temp (
o
C)
Speed 1 0 to 26
Speed 2 26 to 28
Speed 3 28 to 30
Full Speed 30 +
I/O Modules
20
320 JBOD
I/O Modules
There are two I/O option slots located at the rear of the
enclosure. One of these must contain an Enclosure
Services Module (ESM) or a Concentrator Services
Module (CSM) and the other slot can contain one of the
following:
Terminating Services Module (TSM)
Terminator Module (TM)
Joiner Module (JM)
The I/O slot located on the left of the enclosure as viewed
from the back is called I/O Slot A and the I/O slot located on
the right is called I/O Slot B (top and bottom I/O slots
respectively in deskside tower models).
The following sections will describe the modules and how
they should be used.
Enclosure Services
Module ESM
The Enclosure Services Module (ESM) has three primary
functions. It acts as a SCSI bus pass-through from external
cabling to the internal busses. Secondly, it terminates the
end of the SCSI bus in joined mode. Finally, it provides
monitoring, reporting and control of the system storage
enclosure. The ESM reports status and receives control
information via the SCSI bus per the SCSI-3 Enclosure
Services specification and also the SAF-TE specification.
Concentrator
Services Module
The Concentrator Services Module (CSM) includes the
same functionality as the ESM (see above) in addition to
giving the enclosure Clustering capabilities. With a CSM
installed in one I/O Slot and either a CSM or a TSM
installed in the second I/O slot then a Cluster Configuration
is possible. This means that each external SCSI connector
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

Adaptec ULTRAbloc 320 JBOD User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI