Classic Exhibits VK-1961 Setup Instructions

  • Hello! I've reviewed the setup instructions for the VK-1961 Inline Lightbox. It appears to be a modular system with detailed instructions for assembling the frame, installing the SEG graphics and setting up all the components including lights, shelves and monitor mount. I'm here to assist you with any questions you have about the assembly process or the features of this product.
  • What tool is essential for the assembly?
    What should be used to clean the metal, plex, & laminate parts?
    How do components connect together?
© 2023
Order #XXXXX
Locked layer contains
placeholder marks.
Top View
Perspective View
10’
10’
VK-1961 Inline Lightbox
If you would like to tell us about your experience with your setup instructions please email us at [email protected]
SETUP INSTRUCTIONS
REV 05/2023
© 2023
Order #XXXXX
Locked layer contains
placeholder marks.
= 1 sq foot
Grid View
© 2023
Order #XXXXX General Information
DO NOT USE POWER TOOLS
ALL CONNECTIONS MUST
BE TIGHTLY SECURED
Part Identification - Numbering
Spline Connection Base Plate & Extrusion Connection
General Setup Instructions
- Read entire setup instruction manual prior to
unpacking parts and pieces.
- The setup instructions are created specifically
for this configuration.
- Setup instructions are laid out sequentially in
steps, including exploded views with detailed
explanation for assembly.
WARNING
Cleaning & Packing
- For Cleaning Metal, Plex, & Laminate Parts:
Use a MILD NON-ABRASIVE cleanser and
soft cloth/paper towel to clean all surfaces.
- Keep exhibit components away from heat
and prolonged sun exposure.
Heat and UV exposure will warp and
fade components.
- Retain all provided Packing Materials.
All provided packing materials are for
ease of repacking & component protection.
Disassembly
- For loss prevention, tighten all set screws
and locks during disassembly.
7A
Hex Tool - Essential for Assembly
Extrusion & Lock Connection Engaged Lock
LADDERS OR LIFTS
MAY BE REQUIRED
© 2023
Order #XXXXX
Straight Connection
All knobs must be tightened securely to ensure a proper connection.
All knobs must be tightened securely to ensure a proper connection.
Adjust connectors if necessary to
prevent gaps in connection.
Upper Horizontal Extrusion
Lower Horizontal Extrusion
Straight Connector
Straight Connector
Corner
Connectors Corner
Connectors
Corner
Connectors Corner
Connectors
COMPLETED ASSEMBLY
3) Tighten all knobs to secure connection.
Slide verticals over
lower connectors.
Then slide upper
connectors into
groove of verticals.
Tighten all knobs.
When assembling frame, first attach all straight
connectors, then attach corner connectors.
1) Place extrusions end-to-end.
2) Loosen all knobs, then slide straight
connectors across the seam of extrusions.
Disassembly
1) Loosen all knobs.
2) Slide connectors off of one extrusion.
3) Tighten knobs to prevent loss during
packing & shipping.
CEI110 Profile
Slide both connectors across seam of extrusions.
Tighten all knobs.
Corner Connection
3) Tighten all knobs to secure connection.
Disassembly
1) Loosen knobs on vertical extrusions.
2) Slide the vertical extrusions off of
corner connectors on lower and upper
horizontal extrusions.
1) Loosen knobs, then slide vertical extrusions onto
corner connectors of lower horizontal extrusion.
2) Slide corner connectors of upper horizontal
extrusion into grooves of vertical extrusions.
Keep straight connectors in groove of
extrusion. Do not remove connectors
during disassembly.
CEI110 Frame Assembly
© 2023
Order #XXXXX
Using Your Setup Instructions
Cleaning and Packing Your Display
The Euro LT Hybrids Setup Instructions are created specifically for your configuration.
They are laid out sequentially in levels, including exploded views, and a logical series of detailed steps
to assemble the main structure and components. We encourage you to study the instructions before
attempting to assemble your exhibit.
Each page reminds you to tighten the setscrews after disassembling your exhibit to prevent loss of the
locks and setscrews (see below in RED). This is VERY IMPORTANT.
1) Use care when cleaning aluminum extrusion or acrylic inserts. Use only non-abrasive cleaners.
2) When cleaning laminate inserts, countertops, or panels use mild cleansers and a soft material
such as cotton.
3) Keep all display components away from extreme heat and long exposure to sunlight to avoid
warping and fading.
4) Retain all packing material. It will make re-packing much easier and will reduce the likelihood
of shipping damage.
Each component has 2 clips,
the lower clip is ALWAYS
black. The top clip is color
coded to distinguish which
level. The color coded clip
also contains the numbered
label.
Connector
Level 1 = Blue
Level 2 = Red
Level 3 = Green
Level 4 = Black
Panel Lock
When Required
Color Coded Clip
w/ assembly number
Black Clip
is bottom of
panel
L
e
f
t
P
a
n
e
l
R
i
g
h
t
P
a
n
e
l
Cut Away View of
Slide Clips
Components connect together
by aligning them and sliding
downward connecting clips
together.
Configurations are assembled
from left to right, usually
starting with #1 and following
the numbered sequence.
Example of Connection Top View of Panels with Locks
The first level of components contain
panel locks that are located at the top of
the panel for extra stability and seamless
connection. When disassembling panels
twist top connection slightly and lift right
panel upward.
Panel Lock
When Required
Color Coded Clip
w/ assembly number
is top of panel
Left Hand
Grasps Panel
Firmly
With Right Hand Thumb
Close to Seam
Squeeze,
Push Forward,
And Lift
General Setup Instructions for Extrusion System
The Tool Typical Connection Typical Connection (cont’d) Numbered Label
Most exhibits can be assembled
with the supplied Hex Key Tool.
Occasionally, a flat head screw-
driver may be required.
Most horizontal extrusion connections have a patented expandable
lock. This lock inserts into the groove of an opposing extrusion.
Tightening the lock with the Hex Key Tool expands the lock and
creates a strong positive connection.
Each extrusion contains a numbered
label which corresponds with setup
instructions. The label is located
within a groove of the extrusion
(when possible). With extrusion
components the labels contain
Black numbers unless otherwise
specified.
Detail A Detail B Detail C
Horizontal Inline Connection (remove only one setscrew) Base Plate Connection Vertical Connection
(remove only two setscrews)
Detail D Detail E
Setscrews
Remove only (1) setscrew when disassembling.
Replace setscrew in extrusion after assembling
it. Before packing, replace setscrew in extrusion
to avoid losing it.
Attach base plate to round or
square vertical extrusion using
the bolt provided. Be careful
not to strip the threads.
When vertical extrusions are
packed in portable cases rather
than crates or tubs, they must be
broken down into smaller sections
which then require assembly.
Remove only (2) setscrews when
disassembling. Replace setscrews
in extrusion after assembling it.
Before packing, replace setscrews
in extrusion to avoid losing them.
EuroLT Assembly
© 2023
Order #XXXXX
Graphic Removal
To remove the graphic
the frame, locate the fabric
pull tab. Gently pull up on the
tab to remove the fabric.
Step 1
Insert corner A. Turn edge of
graphic so silicon welt is
perpendicular to face of
graphic. Insert narrow side
of welt with fabric to outside
into the channel. Repeat for
other side of this corner.
Step 2
Repeat Step 1 for opposite
corner C, then insert corner
B, followed by corner D, to
complete the installation of
the corners.
Step 3
Once all corners are inserted,
press one silicon edge into
channel from corners and
work toward the center.
Make sure welt is fully inserted
into channel. Continue until
all sides are done. Smooth
out edges of graphic.
It is important to first insert
graphic into each alternate
corner then to the sides of
the frame. If this is not done,
graphic will not fit into the
frame correctly.
Corner A
Corner D
Corner B
Corner C
from
SEG Installation
© 2023
Case 1 of 2
Order #XXXXX
Locked layer contains
placeholder marks.
Top View of Each Level
Level 1
(Bottom level)
Level 2 Level 3 Level 4 Level 5
4A4
2
6 6A
1,1
77A
Shelf
Wings
Base
Plates
35 5A
2A 3A
Shelf
Shelf
Case Packing
© 2023
Case 2 of 2
Order #XXXXX
Locked layer contains
placeholder marks.
Top View of Each Level
Level 1
(Bottom level)
Level 2 Level 3 Level 4 Level 5
Shelf
Supports
2 4 6 8
Connectors
Font & Back
Panels
1 & 5
Side Panels
3 & 7
Shelf
Counter
Top
Graphic
Graphics
Setup Hardware
Monitor Mount
Case Packing
© 2023
Step 1 of 3
Order #XXXXX
Locked layer contains
placeholder marks.
FRONT VIEW
1
4
Transformer
6
6A
2
3
5
5A
7
7A
4A
2A
3A
1
Item
1
2,2A
3,3A
4,4A
5,5A
6,6A
7,7A
Qty.
2
1,1
1,1
1,1
1,1
1,1
1,1
Description
Base Plate
45”w CEI110 Horizontal Extrusion
45”h CEI110 Horizontal Extrusion
42”h CEI110 Vertical Extrusion
42”h CEI110 Vertical Extrusion
42”h S91 Vertical Extrusion
40.187”h Z33 Vertical Extrusion
Steps:
1) Attach base plates [1] to horizontals [2] & [3] using bolts, washers, and wing nuts.
2) Assemble horizontals [2 to 3] [2A to 3A] and verticals [4 to 5] [4A to 5A] together.
See CEI-110 Frame Assembly sheet for instruction.
3) Conect verticals [6] & [6A] together.
4) Attach vertical assembly [6/6A] to assembly [4A/5A], using bolts.
See S91 to CEI110 Attachment detail.
5) Attach verticals [7-7A] between horizontals as shown.
6) Connect lighting cords and attach transformers. See
Light to Light Connections & Light to Transformer details.
7) Install SEG graphic to front of assembled frame and blocker fabric to back.
See SEG Graphic Installation sheet for details.
*
*
*
Power
Break
Power
Break
Transformer
Connector
S91
CEI110
S91 to CEI110 Attachment
*
Bolt
Slide connector into groove of S91
extrusion. Tighten set screws to secure
connector. Attach CEI110 extrusion
to S91, using bolt.
Lighting Installation Warning
Bolt Nylon
Washer
If utilizing your own hardware,
purchase nylon washers to prevent
metal screw heads from damaging
the circuit board.
Attach no more than seven lights
per chain.
Diamond
Washer
++
--
Lights Male
Light to Light Attachment
Maximum of 7 lights per chain,
12 lights per Transformer
Light to Transformer Attachment
+
-
Power
Female
Transformer
144W / 6 Amp / 24V
Backwall Assembly
© 2023
Step 2 of 3
Order #XXXXX
Locked layer contains
placeholder marks.
6A
6
Shelf
Shelf
Shelf
*
*
*
Shelf Attachment
Insert Lock into groove of vertical
extrusion and tighten Set Screw.
Lock
Set Screw
Shelf
*
Knob
Set Screw
Connector
1) Slide connector of clamp
into extrusion groove.
2) Tighten set screw when
A10 is in desired location.
3) Insert wing into clamp.
4) Tighten knob on clamp
to secure wing in place.
A10 Clamp
A10 Clamp
Monitor Mount Attachment
Connectors
V4
Connectors
*
Slide V4 Connectors into groove
of Extrusion. Tighten Set Screws
to secure connectors in place.
Attach Monitor Mount back
piece to Extrusion, using bolts.
Then slide monitor mount into
back piece.
Monitor
Mount
Back
Piece
Bolts
Monitor
Mount *
Completed Assembly
Steps:
1) Lock shelves to vertical [6]. See Shelf Attachment detail.
2) Attach monitor mount to vertical [6A]. See Monitor Mount Attachment detail.
3) Attach wings to top and sides, using A10 clamps. See A10 Clamp detail.
Backwall Attachments
© 2023
Step 3 of 3
Order #XXXXX
Locked layer contains
placeholder marks.
Completed Assembly
Top View of Counter Base Assembly
1
5
7
8
6
3
2
4
Velcro Shelf Supports
to inside of assembled
Counter Base.
Align hole with pin Rotate pin. Spring
will push pin into hole.
Counter Top Lock
12
*
Pin
Hole
Item
1
2
3
4
5
6
7
8
Qty.
1
1
1
1
1
1
1
1
Description
23”w x 38”h Panel
38”h Connector
16”w x 38”h Panel
38”h Connector
23”w x 38”h Panel w/ Door
38”h Connector
16”w x 38”h Panel
38”h Connector
Steps:
1) Attach panels and connectors together in numerical order.
See LT Panel Assembly sheet for instructions. Make sure
Velcro is facing inward.
2) Connect Shelf Supports to Velcro on interior of panels,
then set shelf on top of supports.
3) Lock counter top onto panels [3] and [7].
See Counter Top Lock detail.
4) Attach graphic to panel [1], using standoffs & screw caps.
*
Graphic
Counter Top
Shelf
Shelf supports
Shelf supports
Screw
Cap
1” Standoff *
7
3
1
MOD-1560 Counter Assembly
/