UniPOS VIT 01 Service Instructions

Category
Fire protection
Type
Service Instructions

UniPOS VIT 01 is a wireless fire control panel that monitors wireless fire detectors for fire and fault conditions. In case of a fire, the panel's sounder will release a sound signal and the indicator for fire condition will start flashing. On the display, a text message will appear, indicating the zone and address of the detector that is in "Fire condition".

The panel also has fault condition indicators that will light up in case of any fault condition, such as a fault in the power supply or a fault in a monitored output. The panel's sounder will also release a discontinuous sound signal in case of a fault condition.

UniPOS VIT 01 is a wireless fire control panel that monitors wireless fire detectors for fire and fault conditions. In case of a fire, the panel's sounder will release a sound signal and the indicator for fire condition will start flashing. On the display, a text message will appear, indicating the zone and address of the detector that is in "Fire condition".

The panel also has fault condition indicators that will light up in case of any fault condition, such as a fault in the power supply or a fault in a monitored output. The panel's sounder will also release a discontinuous sound signal in case of a fault condition.

UniPOS WIRELESS FIRE CONTROL PANEL VIT01
Service instruction for the staff page 1
Revision 1 pages 2
SERVICE INSTRUCTIONS FOR THE STAFF
FOR WIRELESS
FIRE CONTROL PANEL VIT01
1. Indications and buttons
Fig.1
1 Common indicator “Fire condition”
2 Common indicator “Fault condition ”
3 Indicator “System fault”
4 Indicator “Fault in power supply”
5 Indicator “Fault in monitored output”
6 Indicator “Disabled component”
7 Indicator “Zone in test”
8 Button “Menu”
9 Button “Down”
10 Button “Up”
11 Button “Cancel”
12 Zone indicators for “Fire condition” and “Fault condition”
13 Indicator “Power supply”
14 Button “Reset”
15 Button “Inspection”
16 Indicator “Inspection”
17 Button “Suppress alarm” with indicator “Suppressed alarm”
18 Indicator “Suppressed alarm”
19 Button “Outputs”
20 Indicator “Suppressed outputs”
21 LCD Display (4х20)
UniPOS WIRELESS FIRE CONTROL PANEL VIT01
Service instruction for the staff page 2
Revision 1 pages 2
2. Duty Mode
The Fire Control Panel is in Duty Mode when there is no Fire condition or Fault condition into the panel
or into the connected to it wireless devices.
In this Mode is active only the green LED indicator (“Power supply”).The local sound indicator is off.
On the display appears “Security Mode” and information about the current local time.
3. Actions for the staff on duty when a “Fault condition” signal is released
The light indications for various types of fault conditions are shown on fig.1.
Upon any registered fault condition the sounder of the Fire Control Panel releases discontinuous sound
signal and the display shows the type of the fault condition. In case of fault condition in fire detector of a
Zone, the relative zone indicator also lights up with yellow light.
To stop the sound signaling, press button (pos.17). Then the indicator lights up (pos.18)
and the sound signaling is suppressed.
In case indicators and illuminated, check for available voltage 220 V at the power
supply panel, or at the back up battery supply. When the power supply is restored, the light
indications for fault condition extinguish.
In all other cases when fault condition is released, press button, (pos.17) to stop the
sounder and notify the service company.
4. Actions for the staff on duty when a”Fire condition” signal is released
Upon fire activation of a wireless fire detector, the Control Panel’s sounder releases sound signal and
simultaneously indicator for fire condition starts flashing. On he display appears a text message,
indicating the Zone and the Address of the detector which is in “Fire condition”.
In such case perform the following actions:
4.1. As fast as possible check for fire existence (smoke, heat or flames) in the indicated zone.
Possible options for further actions:
4.1.1. If there is no fire (no smoke, heat or flames) and the activation of the fire detector is ‘’false
alarm’’, press the Reset Button. The fire Control Panel is set to Duty Mode. In case another “false activation”
occurs in the same zone, inform your service company immediately.
4.1.2. In state of fire, as fast as possible leave the protected premise and take measures, described
in the Fire Safety Code of the premise.
4.2.3. Pressing “Reset” button resets the fire detectors in “Fire condition” and the Control Panel goes
into “Duty Mode”.
UniPOS wishes you a successful work!
  • Page 1 1
  • Page 2 2

UniPOS VIT 01 Service Instructions

Category
Fire protection
Type
Service Instructions

UniPOS VIT 01 is a wireless fire control panel that monitors wireless fire detectors for fire and fault conditions. In case of a fire, the panel's sounder will release a sound signal and the indicator for fire condition will start flashing. On the display, a text message will appear, indicating the zone and address of the detector that is in "Fire condition".

The panel also has fault condition indicators that will light up in case of any fault condition, such as a fault in the power supply or a fault in a monitored output. The panel's sounder will also release a discontinuous sound signal in case of a fault condition.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI