NEC UNIVERGE NEAX 2000 IPS Configuration manual

Type
Configuration manual
NDA-24347
ISSUE 1
STOCK # 152051
Configuration Guide
®
MAY, 2002
NEC America, Inc.
LIABILITY DISCLAIMER
NEC Corporation reserves the right to change the specifications, functions,
or features, at any time, without notice.
NEC Corporation has prepared this document for use by its employees
and NEC subsidiary. The information contained herein is the property of
NEC Corporation and shall not be reproduced without prior written
approval from NEC Corporation.
NEAX
®
and Dterm
®
are registered trademarks of NEC Corporation.
Copyright 2002
NEC Corporation
Printed in the U.S.A
ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4
DATE MAY, 2002 DATE DATE DATE
ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8
DATE DATE DATE DATE
NEAX 2000 IPS
Configuration Guide
Revision Sheet 1/2
NDA-24347
PAGE No.
ISSUE No.
1 2 3 4 5 6 7 8
i 1
ii 1
iii 1
iv 1
v 1
vi 1
1 1
2 1
3 1
4 1
5 1
6 1
7 1
8 1
9 1
10 1
11 1
12 1
13 1
14 1
15 1
16 1
17 1
18 1
19 1
20 1
21 1
22 1
23 1
24 1
25 1
26 1
27 1
28 1
29 1
30 1
31 1
32 1
33 1
34 1
35 1
36 1
37 1
38 1
39 1
40 1
41 1
42 1
43 1
44 1
45 1
46 1
47 1
48 1
49 1
50 1
51 1
52 1
53 1
54 1
55 1
56 1
57 1
58 1
59 1
60 1
61 1
62 1
63 1
64 1
65 1
66 1
67 1
68 1
69 1
70 1
PAGE No.
ISSUE No.
12345678
ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4
DATE MAY, 2002 DATE DATE DATE
ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8
DATE DATE DATE DATE
NEAX 2000 IPS
ConfigurationGuide
Revision Sheet 2/2
NDA-24347
71 1
72 1
73 1
74 1
75 1
76 1
77 1
78 1
79 1
80 1
81 1
82 1
83 1
84 1
85 1
86 1
PAGE No.
ISSUE No.
12345678
PAGE No.
ISSUE No.
12345678
NDA-24347
ISSUE 1
MAY, 2002
NEAX 2000 IPS
Configuration Guide
TABLE OF CONTENTS
Page
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page i
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
NEAX 2000 Internet Protocol Server (IPS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
NEAX 2000 IPS Highlights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 2 System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Port Interface Modules (PIMs). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Floor-standing Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Wall-mounting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
19-inch Rack-mounting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
System Outline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Station-to-Station Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
CCIS Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
H.323 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
System Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Overall System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Peer-to-Peer Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
CCIS Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
H.323 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
IP-PAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Device Registration Server (DRS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Legacy Interface (LT/AP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
IP-PAD/VCT Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Mounting IP-PAD Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Mounting VCT Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Mounting Conditions of IP-PAD/VCT Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
BUS Cable Connection between IP-PAD and VCT Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
LAN Cable Connection of IP-PAD Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
LAN Cable Connection of ETHER Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
TABLE OF CONTENTS (CONTINUED)
Page
NEAX 2000 IPS Configuration Guide
Page ii NDA-24347, Issue 1
Chapter 3 Module and Installation Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Port Interface Module (PIM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Battery Module (BATTM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Installation Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Base/Top Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Hanger Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
19-inch Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Optional Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Chapter 4 Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
NEAX 2000 IPS Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Card Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Common Control Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Main Processor (MP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Firmware Processor (FP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Line/Trunk (LT) Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Application Processor (AP) Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Chapter 5 System Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
AC/DC Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
DC/DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Battery Backup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Short-term Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Long-term Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Power Failure Transfer (PFT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
PZ-8PFTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Chapter 6 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Internal Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
BUS Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Power Control Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
DC Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
AC Cord. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
External Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
IP Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Attendant Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Maintenance Administration Terminal (MAT) (RS-232C). . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Built-in SMDR/MCI on MP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
SMDR (with AP00)/PMS/Hotel Printer/MCI/CCIS Centralized SMDR. . . . . . . . . . . . . . . . . . 66
External Alarm Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Digital Trunk Interface (DTI)/Primary Rate Interface (PRI)/CCIS Trunk Interface (CCT). . . . 68
Data Port Controller (DPC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1 Page iii
TABLE OF CONTENTS (CONTINUED)
Page
DPC and X.21/V.35 Converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Chapter 7 Dterm IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Dterm IP Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Dterm IP Login/Logout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Dterm IP Login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Dterm IP Logout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Chapter 8 System Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Main Processor (MP) System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Floor-standing Installation Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
LT/AP Card Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Line Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Zone Transceiver Line Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Traffic Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
System-based Device Registration Server (DRS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
LIST OF FIGURES
Figure Title Page
NEAX 2000 IPS Configuration Guide
Page iv NDA-24347, Issue 1
Figure 1-1 NEAX 2000 Internet Protocol Server (IPS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Figure 1-2 Simplified View of NEAX 2000 IPS System Connectivity . . . . . . . . . . . . . . . . . . . . . . . 2
Figure 1-3 Hybrid System of IP and Time Division Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 1-4 NEAX 2000 IPS MP and IP-PAD Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Figure 2-1 System Configuration with Dterm IP (512-Port Configuration) . . . . . . . . . . . . . . . . . . . 8
Figure 2-2 Floor-standing Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2-3 Wall-mounting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 2-4 19-inch Rack-mounting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 2-5 System Outline of NEAX 2000 IPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 2-6 System Outline of Station-to-Station Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 2-7 System Outline of CCIS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 2-8 System Outline of H.323 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 2-9 Mounting IP-PAD Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 2-10 Mounting VCT Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 2-11 IP-PAD BUS Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 2-12 IP-PAD - Switching HUB Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 2-13 ETHER - Router/Switching HUB Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 3-1 Unit Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 3-2 PIMMD Face Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 3-3 Floor-standing Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 3-4 Wall-mounting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 3-5 19-inch Rack-mounting Installation (Bracket A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 3-6 19-inch Rack-mounting Installation (Bracket B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 3-7 Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 3-8 I/F Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 3-9 Base Tray Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 4-1 PIM Face Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 4-2 Port Allocation of Time Division Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 5-1 PZ-8PFTB Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 6-1 BUS Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 6-2 Power Cable Connection (Internal Battery Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 6-3 Power Cable Connection (External Battery Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 6-4 AC Cord Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 6-5 IP BUS Cable Connection (IP PAD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 6-6 IP BUS Cable Connection (IPT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 6-7 Attendant Console Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 6-8 MAT Cable Connection (Direct) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 6-9 MAT Cable Connection (Remote Connection via Internal Modem) . . . . . . . . . . . . . . . 64
Figure 6-10 MAT Cable Connection (Remote Connection via External Modem) . . . . . . . . . . . . . . 64
Figure 6-11 Cable Connection for Built-in SMDR/MCI on MP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 6-12 AP00 Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 6-13 External Alarm Display Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 6-14 DTI Cable Connection (Twisted-pair Cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1 Page v
LIST OF FIGURES (CONTINUED)
Figure Title Page
Figure 6-15 DPC Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 6-16 DPC and X.21/V.35 Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Figure 7-1 Dterm IP Display (ID Registration without Password) . . . . . . . . . . . . . . . . . . . . . . . . . 76
Figure 7-2 Dterm IP Display (ID Registration with Password) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
LIST OF TABLES
Table Title Page
NEAX 2000 IPS Configuration Guide
Page vi NDA-24347, Issue 1
Table 2-1 IP-PAD/VCT Card Mounting Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 3-1 Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 3-2 Installation Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 4-1 Location of Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 4-2 Common Control Cards and System Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 4-3 Line/Trunk (LT) Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 4-4 Application Processor (AP) Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 5-1 AC/DC Power Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 5-2 DC/DC (-48 V) Power Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 5-3 PZ-8PFTB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 6-1 BUS Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 6-2 Power Control Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 6-3 Power Cable (Internal Battery Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 6-4 Power Cable (External Battery Option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 6-5 AC Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Table 6-6 IP BUS Cable (IP PAD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 6-7 IP BUS Cable (IPT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 6-8 MAT Cable (Direct) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 6-9 MAT Cable (Remote Connection via External Modem) . . . . . . . . . . . . . . . . . . . . . . . . 64
Table 6-10 Cable for Built-in SMDR/MCI on MP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 6-11 Cable for AP00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 6-12 External Alarm Display Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Table 6-13 DPC Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 6-14 DPC and X.21/V.35 Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table 7-1 User Menu Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 7-2 Administrator Menu Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Table 8-1 Main Processor (MP) System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Table 8-2 Required Common Equipment for Floor-standing Installation . . . . . . . . . . . . . . . . . . . 82
Table 8-3 Number of Slots for LT/AP Cards of each PIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Table 8-4 Line Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Table 8-5 Zone Transceiver Line Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Table 8-6 Traffic Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Table 8-7 System-based Device Registration Server (DRS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 1
Chapter 1 Introduction
NEAX 2000 Internet Protocol Server (IPS)
NEAX 2000 Internet Protocol Server (IPS) is a full-featured IP-based
communications system providing a rich feature set of existing NEAX 2000 IVS
2
,
with pure Voice over IP (VoIP) communications (Peer-to-Peer connections), across
corporate Local and Wide Area Networks (LAN and WAN).
Dterm IP telephones are designed to provide a converged infrastructure at the desktop,
with a 100 BASE-T Ethernet connection to the LAN and built-in hub for a PC
connection to the telephone itself. The system can provide Peer-to-Peer connections
between Dterm IP telephones with voice compression, offering existing Dterm Series
E telephone features. In a WAN, the system can provide Peer-to-Peer connections
over IP networks with voice compression through CCIS (CCIS over IP).
The NEAX 2000 IPS can provide Legacy station/trunk interfaces to support the
existing Time Division Multiplexing (TDM) based infrastructure, such as analog
telephones, analog networks, and digital networks (T1/E1 and ISDN). The Legacy
station/trunk interface cards (LT and AP cards) can be accommodated in the Port
Interface Module (PIM), in the same manner as the NEAX 2000 IVS
2
. At maximum
configuration, the NEAX 2000 IPS supports 512 LT ports which can be 448 Dterm IP
telephones and 64 Legacy LT ports, and 256 ports for Legacy AP cards.
Communications between Legacy stations/trunks and Dterm IP telephones/IP
networks are made via IP PAD, that converts packet-based voice data to TDM-based
voice data, and vice versa. The new Main Processor (MP) card controls both
Peer-to-Peer connections and TDM-based connections. The new MP card
incorporates a built-in Device Registration Server (DRS) and single interface point of
IP connections to IP telephone, MATWorX, and OAI/ACD servers.
Figure 1-1 NEAX 2000 Internet Protocol Server (IPS)
NEAX 2000 IPS Configuration Guide
Page 2 NDA-24347, Issue 1
NEAX 2000 Internet Protocol Server (IPS) Chapter 1 Introduction
Figure 1-2 Simplified View of NEAX 2000 IPS System Connectivity
TDSW
IP-PAD
MP
TIE
IPT (H.323
Handler)
SLT/Dterm
LC/DLC
Client PC
Dterm IP
Router
Router
MATWorX
Router
H.323 GK
Switching
Dterm IP
Client PC
Switching HUB (100 Mbps)
Internet
Dterm IP
DHCP
Server
NEAX 2000 IPS
NEAX 2000 IPS
(via LAN)
OAI
Server
/Intranet
MATWorX
(via IPT: CCIS)
DRS
MATWorX
(via RS-232C)
COT
HUB
PSTN
Chapter 1 Introduction NEAX 2000 Internet Protocol Server (IPS)
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 3
NEAX 2000 IPS
Highlights
NEAX 2000 IPS highlights are as follows:
• Hybrid System of IP (Peer-to-Peer connection) and TDM Switching
The NEAX 2000 IPS supports both pure IP switching (Peer-to-Peer connections)
and Time Division switching. The pure IP switching is provided for
communications between Dterm IP telephones and for CCIS network with
another NEAX 2000 IPS/2400 IPX (CCIS over IP). On the other hand, the TDM
switching is provided for communications between Legacy stations/trunks.
Connections between Dterm IP/CCIS over IP and Legacy stations/trunks are
made via IP PADs, which converts packet-based voice data to TDM-based voice
data, and vice versa.
Figure 1-3 Hybrid System of IP and Time Division Switching
Note 1: CCIS over IP using Peer-to-Peer connections is available with the NEAX
2000 IPS and NEAX 2400 IPX only.
Note 2: IP PAD: IP Packet Assembly Disassembly
Note 3: DRS: Device Registration Server
TSW
MP
LAN
IP Network
IP PAD
Router
Peer-to-Peer
Connection
(Dterm IP)
LT/TRK
AP
Time Division
Switching
IP Switching
IP/TSW Conversion
Linked with CCIS over IP
Dterm IP
Dterm IP
Call Control
Speech Path
with TSW
NEAX 2000 IPS
NEAX 2000 IPS/
NEAX 2400 IPX
Built-in DRS
Peer-to-Peer
Connection
(CCIS)
Note 3
Note 2
Note 1
NEAX 2000 IPS Configuration Guide
Page 4 NDA-24347, Issue 1
NEAX 2000 Internet Protocol Server (IPS) Chapter 1 Introduction
• One-board Main Processor (MP) with Integrated Functionality
NEAX 2000 IPS Main Processor (MP) is the heart of pure IP connections and
TDM-based connections. The MP employs a high-speed CPU, which is
equivalent with Pentium. With this processing power and System On Chip (SOC)
technology, the MP integrates Device Registration Server (DRS), AP01 (OAI)
functions, which are provided by an additional card in the previous NEAX 2000
IVS series. Also, by means of LSI technology, the MP card size is minimized and
an Ethernet Interface Card is mounted on the MP without using an additional slot
space in the PIM. This interface card is linked with LAN for call control
processing of Dterm IP and inter-work with MATWorX and OAI server.
Figure 1-4 NEAX 2000 IPS MP and IP-PAD Configuration
(Pentium-
equivalent)
OSC
Connector
New
Engine
Chip
RS
Driver
Power
Supply
Circuit
Alarm and
DK Circuit
MOH
Source
Ethernet
Transforme
r
Connector
RS
Driver
PZ-M606-A
PN-CP24-A
AP01 Function and TCP/IP
protocol are integrated into MP
NIC
IP PAD
PN-32IPLA
+
PN-16VCTA
osc
MOH
Source
Chapter 1 Introduction NEAX 2000 Internet Protocol Server (IPS)
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 5
• Built-in Device Registration Server (DRS) on MP
The NEAX 2000 IPS incorporates the DRS on the MP, which provides
Log-in/Log-out management of the Dterm IP including Registration,
Authentication. Also, the built-in DRS can communicate with the DHCP server to
provide easy administration of IP address.
• Enhanced Built-in Firmware Processor (FP) on MP
NEAX 2000 IVS
2
requires FP card in PIM 0 when the system configured with
three or more PIMs. In the case of the NEAX 2000 IPS, an FP in PIM 0 is not
required since the Built-in FP function in the MP has been improved, providing
more call processing capability. (FP is used in PIM 2, 4 and 6.)
• Migration Path for NEAX 2000 IVS
2
For the customers who are using NEAX 2000 IVS
2
, the migration path is
supplied. By replacing the existing MP card to a new one, the NEAX 2000 IVS
2
can be upgraded to IP/TSW Hybrid System including new and enhanced service
features introduced with the NEAX 2000 IPS. If a user wants to implement
Peer-to-Peer connection services, it is available by adding the IP PAD to the
existing system with the new MP.
• Reduced Hardware with IP based Architecture
The Dterm IP telephones accommodated in LAN do not require a DLC card
because they can be interfaced directly with LAN and have Peer-to-Peer
connection. When a Dterm IP is connected with a station/trunk, which is
accommodated in the TSW, the speech path between LAN and TSW is made via
IP PAD under the call processing control of MP. The Dterm IP can be expanded
by adding the terminal itself and IP PAD if traffic volume is increased. With this
system architecture, the hardware (DLC, PIM, and Power Supply) is reduced.
This makes moves, adds, and changes easier.
• Office Data Backup Enhancement
The office data of NEAX 2000 IPS is stored in Flash ROM. Therefore the backup
period is extended compared with previous NEAX 2000 systems that used RAM
with battery.
• Various Installation Methods
To meet the specific needs of the customer’s environment, NEAX 2000 IPS
provides the following installation methods:
• Floor-standing Installation
• Wall-mounting Installation
• IEC standard 19-inch Rack-mounting Installation
• Unified Circuit Card Size
All the circuit cards for NEAX 2000 IPS are designed in one size (PN-type), and
installed in the PIM. This ensures that slot space is used efficiently within the
PIM.
NEAX 2000 IPS Configuration Guide
Page 6 NDA-24347, Issue 1
NEAX 2000 Internet Protocol Server (IPS) Chapter 1 Introduction
• High Density Line/Trunk (LT) Cards
Major Line/Trunk cards used in NEAX 2000 IPS are provided with eight circuits
per card. This allows the physical system size to be compact.
• Universal Slot
One PIM provides 12 card slots for Line/Trunk (LT). These card slots can also be
used for Application Processor (AP) cards without complicated limitation. As this
makes easy quotation and installation, more number of AP cards can be mounted
in one PIM.
• DC/DC Power Supply for -48 V
The PIM houses an optional DC/DC Power Supply for the cards that require -48 V
power (such as the CSI card, used as the interface for a wireless system’s Zone
Transceiver). Since this power supply is mounted in the space under the AC/DC
power, no additional Power Module/card slots are required.
• Extended Application Processor (AP) Port Capacity
The NEAX 2000 IPS provides maximum 256 AP ports and it is independent of
the 512 ports for the Line/Trunk (LT). Therefore, more number of AP cards can
be used in the system such as T1/E1 digital link.
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 7
Chapter 2 System Configuration
Port Interface Modules (PIMs)
NEAX 2000 IPS consists of a number of Port Interface Modules (PIMs) depending on
the system configuration. There are two types of PIMs:
• Physical PIM
• Virtual PIM
The Physical PIM is a hardware PIM and is used to accommodate an MP, FPs, IP
PADs, Legacy LT and AP cards, and power supply units. One Physical PIM provides
up to 64 LT ports.
The Virtual PIM is a software PIM and is used to assign Dterm IP telephones by
system programming (The Physical PIM can be used to assign Dterm IP telephones,
but is not essential.). One Virtual PIM provides up to 64 Dterm IP telephones. The
system consists of up to eight PIMs, by the combination of Physical PIMs and Virtual
PIMs, thus providing a total of 512 ports for Dterm IP telephones and Legacy LT
cards. Total number of ports for Dterm IP telephones and Legacy LT cards must be
less than 512, so the number of Physical PIMs decreases when that of Virtual PIMs (=
number of Dterm IP telephones) increases.
Example: When 256 Legacy LT ports are required (= four Physical PIMs), the
maximum number of Dterm IP telephones is 256.
Figure 2-1 shows examples of 512-port configuration by the combination of Legacy
LT ports and Dterm IP telephones.
NEAX 2000 IPS Configuration Guide
Page 8 NDA-24347, Issue 1
Port Interface Modules (PIMs) Chapter 2 System Configuration
Figure 2-1 System Configuration with Dterm IP (512-Port Configuration)
PIM 3
PIM 2
PIM 1
PIM 0
PIM 7
PIM 6
PIM 5
PIM 4 PIM 0 PIM 4 PIM 0 PIM 4 PIM 0 PIM 4
PIM 1
PIM 2
PIM 3
PIM 5
PIM 6
PIM 7
PIM 1
PIM 2
PIM 3
PIM 5
PIM 6
PIM 7
PIM 1
PIM 2
PIM 3
PIM 5
PIM 6
PIM 7
64 LT ports +
448 Dterm IPs
128 LT ports +
384 Dterm IPs
192 LT ports +
320 Dterm IPs
256 LT ports +
256 Dterm IPs
PIM 3
PIM 2
PIM 1
PIM 0
320 LT ports +
192 Dterm IPs
PIM 4
PIM 5
PIM 6
PIM 7
PIM 0 PIM 4
PIM 1
PIM 2
PIM 3
PIM 5
PIM 6
PIM 7
384 LT ports +
128 Dterm IPs
PIM 0 PIM 4
PIM 1 PIM 5
PIM 2
PIM 3
PIM 6
PIM 7
448 LT ports +
64 Dterm IPs
PIM
Physical PIM
PIM 0 PIM 4
PIM 1 PIM 5
PIM 2
PIM 3
PIM 6
PIM 7
512 LT ports +
0 Dterm IPs
PIM
Virtual PIM
Chapter 2 System Configuration Floor-standing Installation
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 9
Floor-standing Installation
In Floor-standing Installation, the NEAX 2000 IPS is comprised of up to eight Port
Interface Modules (PIMs).
Figure 2-2 Floor-standing Installation
BASE
PIM 0
PIM 0
PIM 1
PIM 0
PIM 1
PIM 2 PIM 2
PIM 3
PIM 1
PIM 0
BASE BASE BASE
(64 ports) (128 ports) (192 ports) (256 ports)
PIM 2
PIM 3
PIM 1
PIM 0
BASE
(320 ports)
BASE
PIM 4
PIM 2
PIM 3
PIM 1
PIM 0
BASE
(384 ports)
PIM 4
PIM 5
BASE
PIM 2
PIM 3
PIM 1
PIM 0
BASE
PIM 4
PIM 5
PIM 6
BASE
(
448
p
orts
)
PIM 2
PIM 3
PIM 1
PIM 0
BASE
PIM 6
PIM 7
PIM 5
PIM 4
BASE
(
512
p
orts
)
NEAX 2000 IPS Configuration Guide
Page 10 NDA-24347, Issue 1
Wall-mounting Installation Chapter 2 System Configuration
Wall-mounting Installation
The NEAX 2000 IPS can be wall-mounted in a single or multiple PIM configuration.
A maximum of eight PIMs can be mounted in this way.
Figure 2-3 Wall-mounting Installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

NEC UNIVERGE NEAX 2000 IPS Configuration manual

Type
Configuration manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI