Miele 51620745USA Operating Instructions Steam Heated

Type
Operating Instructions Steam Heated
Installation plan
Washer
PW 6207 D (Steam Heated)
Always read operating and installation instructions before
Installation and Commissioning.
This is for the protection of yourself and your machine.
en - US
10 002 290 / 01
2 10 002 290 / 01
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved!
10 002 290 / 01 3
Machine dimensions (measurements in millimeters)
4 10 002 290 / 01
Connections (measurements in millimeters)
10 002 290 / 01 5
Machine dimensions (measurements in millimeters)
6 10 002 290 / 01
Machine dimensions (measurements in millimeters)
10 002 290 / 01 7
Machine dimensions (measurements in inches)
8 10 002 290 / 01
Connections (measurements in inches)
10 002 290 / 01 9
Machine dimensions (measurements in inches)
10 10 002 290 / 01
Machine dimensions (measurements in inches)
Technical datasheet: PW 6207 D
10 002 290 / 01 11
Technical datasheet
Washer-extractor:
Heating:
PW 6207
Steam
Legend:
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
UM
Miele base
9 7/16"
240 mm
35 7/16"
900 mm
39 3/4"
1009 mm
9 7/16"
240 mm
36 1/4"
920 mm
40 1/8"
1019 mm
BS
Concrete base
9 7/16"
240 mm
3 15/16"
100 mm
36 1/4"
920 mm
41 5/16"
1050 mm
DAV
Steam
connection valve
0 - 145 psi
0 - 1000 kPa
1/2"
Technical datasheet PW 6207 D
12 10 002 290 / 01
EL
Electrical
connection
Standard voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
3 AC 208 V
50 - 60 Hz
3.0 kW
3 x 15 A
4 x AWG 16
4 × 1.5 mm²
3 AC 220 - 240 V
50 - 60 Hz
4.3 kW
3 x 15 A
Convertible to
Frequency
Rated load
Fuse Rating
Connection cable, min. cross-section
4 x AWG 16
4 x 1.5 mm²
Connection cable not included.
The electrical connection may only be made to an electrical system listed in accordance with the national laws,
ordinances and directives as well as the local provisions.
In addition to this, the regulations of the power supply utility, the accident prevention regulations and the insurance
company applicable at the site of installation as well as the recognized standards of technology must also be
observed.
The installation must be performed by a qualified person (electrician).
The appliance can be connected either via permanent connections or via plug connections according to IEC
60309-1. Wall receptacles or main separation devices must be accessible after the appliance is installed.
However, we recommend connecting the appliance via a plug connection so that an electrical safety check can be
carried out, e.g. during repair or maintenance.
If it is necessary to install a residual current device (RCD) in accordance with the local regulations, a residual
current device type B (AC/DC-sensitive) must always be used.
PA
Potential
equalization
Externally threaded supports
for shrims and nuts
If necessary, equipotential bonding with good galvanic
contact must be created, in compliance with all
applicable local installation specifications.
3/8" x 1 3/8"
10 M
10 x 35 mm
D
Steam
connection
(indirect steam)
Steam pressure
87 - 145.04 psi
600 - 1000 kPa
Boiling point
305.6 - 363.2 °F
152 - 184 °C
Steam supply capacity
127.9 lbs/h
58 kg/h
Heat output
109260 BTU/h
32 kW
Connection thread (on-site)
1/2"
internal thread
Steam valve, steam filter, steam faucet must be
provided on-site.
Follow installation instructions for steam-heated Miele washer-extractors.
K
Condensate
connection
Connection thread (on-site)
1/2"
internal thread
Steam valve, steam filter and steam faucet must be
provided on-site.
Installation of the steam trap needs to allow complete
drainage of the heater element during machine
downtime. This means, no condensate is left in the
heater element.
Installation of an inverted bucket steam trap is
recommended.
Technical datasheet: PW 6207 D
10 002 290 / 01 13
KW
Cold water
(Soft water)
Water pressure/Min. flow rate
14.5 psi
100 kPa
Water pressure/Max. flow rate
145 psi
1000 kPa
Max. volume flow
6.87 gal/min
26 l/min
Max. volume flow in absence of hot and hard water
supply
11.1 gal/min
42 l/min
2 Connector hoses with threaded joint 3/4” including
Y fitting (3/4” / 1”) included with the unit.
Threaded connector fitting at site as per DIN 44 991
(flat sealing)
1" external thread
Length of connection hose
59 1/16"
1500 mm
Average water requirement for a standard program
(60°C colored washing) determined at cold, hot and
hard water connection.
approx. 32.8 gal/h
approx. 124 l/h
Add the hot water water requirement to the cold
water requirement, if there is no hot water supply
available.
If connecting to industrial water supply (optional),
subtract that water requirement from the cold water
requirement.
WW
Hot water
(Soft water)
Max. temperature
158°F
70°C
Min. flow pressure
14.5 psi
100 kPa
Max. pressure
145.04 psi
1000 kPa
Max. throughput
4.22 gal/min
16 l/min
On-site connection thread according to DIN 44 991
3/4" external thread
Length of connection hose
(supplied) 1 connection hose)
59 1/16"
1500 mm
Water requirements (average for 60°C
programme)
approx. 28.5 gal /h
approx. 108 l/h
Machine can be connected to a hot water supply
line with a temperature of 70°C to max. 85°C. This
requires a separate inlet hose. This additional inlet
hose is available from Miele Spares. The machine
must also be reprogrammed by Miele Service or an
authorised agent.
If hot water is not available, connect hot water hose
to cold water valve!
KWH
Cold water
Water pressure/Min. flow rate
14.5 psi
100 kPa
(Hard water)
Water pressure/Max. flow rate
145.04 psi
1000 kPa
Max. volume flow
8.45 gal/min
32 l/min
Threaded connector fitting at site as per DIN 44 991
(flat sealing)
1" external thread
Length of connector hose
59 1/16"
1500 mm
Avarage water requirement for a standard program
(60° colored washing) determined at cold, hot and
hard water connection
approx. 19.5 gal/h
approx. 74 l/h
KWF
Cold Water
(Liquid
dispensing)
Water pressure/Min. flow rate
14.5 psi
100 kPa
Water pressure/Max. flow rate
145.04 psi
1000 kPa
Max. volume flow
1.45 gal/min
5.5 l/min
1 Connector hose with threaded joint 3/4” optionally
included with the unit.
Threaded connector fitting at site as per DIN 44991
(flat sealing)
3/4" external thread
Length of connector hose
59 1/16"
1500 mm
AV
Drainage
Max. water outflow temperature
203 °F
95°C
Dump valve
Drainage supports in machine (outer diameter)
2 15/16"
75 mm [DN 70]
On-site drain connection (inner diameter)
2 15/16"
75 mm [DN 70]
Max. transient throughput
52.8 gal/min
200 l/min
Vented drainage required. If ventilation is
insufficient, fit Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be
of sufficient cross-section.
Fittings
Without base
It is essential to ensure that the appliance is
fastened adequately to the floor!
Fastening material included with unit:
2 x mounting brackets (from transport lock)
2 x wood screws DIN 571 (Ø x length)
8 mm x 80 mm
2 x screw anchors (Ø x length)
5/16" x 3 1/8"
1/2" x 2 3/8"
12 mm x 60 mm
A sufficiently firm floor with sufficient load-bearing
capacity is necessary for the installation. The
fastening material included is only suitable for a
solid concrete floor. The fastening material for other
suitable floor types must be provided on site.
B
Technical datasheet PW 6207 D
14 10 002 290 / 01
On concrete platform
It is essential to ensure that the appliance is fastened
adequately to the concrete base!
Fastening material included with unit:
2 x mounting brackets (from transport lock)
2 x wood screws DIN 571 (Ø x length)
8 mm x 80 mm
2 x screw anchors (Ø x length)
5/16" x 3 1/8"
1/2" x 2 3/8"
12 mm x 60 mm
The quality of the concrete and its strength must be
assessed according to the machine load. Ensure that
the location of the platform is fixed adequately in case
of dynamic loads!
Miele base
It is essential to ensure that the appliance is fastened
adequately to the floor!
Fastening material included with base:
4 x wood screws DIN 571 (Ø x length)
8 mm x 80 mm
4 x screw anchors (Ø x length)
5/16" x 3 1/8"
1/2" x 2 3/8"
12 mm x 60 mm
The installation and assembly of the appliance and
base must follow the installation instructions provided.
Machine data
Width
36 3/8"
924 mm
Depth
44 1/2"
1130 mm
Height
55 1/8"
1400 mm
Housing width
36 1/4"
920 mm
Housing depth
40 3/16"
1020mm
Width loading opening (clear width)
36 5/8"
930 mm
Recommended wall spacing (to rear edge of
appliance front)
57 1/16"
1450 mm
Minimum wall spacing (to rear edge of appliance
cover)
15 3/4"
400 mm
Net weight
1119.9 lbs
508 kg
Max. floor loading in operation
6076 N
Average heat dissipation in the installation room
(depending on room temperature and selected
program)
5216.5 BTU/h
5.5 MJ/h
Installation should only be carried out by authorized installers in accordance with all local and national regulations! Follow
installation instructions when installing machine! All rights reserved!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Miele 51620745USA Operating Instructions Steam Heated

Type
Operating Instructions Steam Heated

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI