nstallation Guide
Connections: 4 - 1/2" B.S.P. (British Standard Pipe) 2 per side
Maximum positive operating pressure: Standard design: 72 psi
Maximum positive operating pressure: High-pressure design: 116 psi
Maximum operating temperature: 230° F
rectangular steel tubes, 2-3/4"x7/16"x16 ga.
rectangular steel tubes, 2-3/4"x7/16"x14 ga.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
A variety of matching valves and other accessories are available and recommended from MYSON. For
specific applications see our detailed installation and technicals manuals and price book which are
available on our web site.
It is assumed that the installer has the appropriate technical knowledge related to building codes,
standard trade practices, and proper use of the tools of the trade.
Myson radiators should only be used with recirculation pump closed loop hydronic heating systems such as 2 pipe
reverse return, 2 pipe direct return, 1 pipe monoflo or homerun piping systems. Series loop piping is not
recommended. Myson radiators are not for use in gravity or steam systems. Position your radiator away from your
circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could
draw air into the system. The suggested location for your Myson radiator, where possible, is below a window
where it can minimize downdrafts from glazed areas. Mounting the radiator a minimum of 4 inches off the floor
willaprovideaforaadequateaconvection.aa(3
3
/
16
"aminimumafora2Habaseboard)
Myson radiators are supplied with drain plugs, vent plugs, and mounting brackets.
Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and
property damage NOT covered under the Myson Warranty.
Step 1 Fill and vent the system.
Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position.
Step 3 Shut off and drain the system while the water is still hot.
Step 4 Refill the system.
Step 5
Reheat, vent, and balance the system.
Step 6 Once the Décor Radiator is filled with water the system should be left filled.
Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking
radiators internally.
SYSTEM START-UP
MAINTENANCE &
CLEANING
1 Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion.
2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your
Myson radiator.
3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty.
DESIGN AND LAYOUT CONSIDERATIONS:
NOTE! For optimum performance connect the supply to the top and the return to the bottom of the opposite side. Bottom
supply and return will result in a 5% reduced heat output. (See online manual for detailed piping diagrams.)
VALVE ROUGH-IN: When using Myson radiator valves to install your radiator add the following distance from
the end of the radiator to the center of your Supply/Return pipe for each valve.
For 2TRV1/2AN a
nd LKD16AN valves add 1-3/4" ---
For 2TRV1/2IN and FF16LAC/FF16WAC valves add 1-5/8"
MOUNTING: Myson horizon
tal radiators 3H to 11H are supplied with welded mounting lugs located 6-15/16" in
from each end. Myson vertical radiators V11 are supplied with welded mounting lugs located 4-1/4" in from
each end (top and bottom). Pedestal style radiators H34 are supplied with adjustable height stands. Myson
baseboard style radiators 2H are supplied with the appropriate number of brackets for each length. (See
Mounting Detail Supplement for more information)
For more detailed bracket installation dimensions and mounting positions please consult the
detailed installation manual available at MysonComfort.com and/or the assembly instructions
included with the mounting brackets.
SAFETY PRECAUTIONS
Radiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The
temperature of a
radiator is dependent on the temperature of the system water, as set by the system installer
or user. Installers and users should take all necessary steps to minimize the risks of burns. If the risk is
significant, consideration should be given to installing low surface temperature radiators, or to placing guards in
front of the radiators.
For
the correct installation of radiators it is essential that the mounting of the radiator to the wall is carried out
in such a way that it is suitable
for intended use AND predictable misuse.
VENT LOCATION: The radiator vent should be located on the return side of the radiator at the top tapping.
DECOR
10
10
10
MAR 2016
Horizontal & V
ertical design, H & V models
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Side Connections:
All Dimensions are nominal
H34 Pedestal
6-7/8"
1-7/8"
H
11
1"
H22
1-7/8"
3-11/16"
2-11/16"
8
-7/16"
5-
5/8
"
11-1/4"
16-15/16"
22-5/8"
31-1/8"
Overall Heights
Overall Lengths
2-11/16"
V11
78-3/4"
V11
1"
3/16"
3/16"
2-11/16"
13/16" Typical
Overall Length
76-3/4"
5-5/8"
1/2" BSP
489
351
2H11
Height
Model
160
0
F
140
0
F180
0
F
3H11
8-7/16"
1/2" BSP
618
443
627
791
8H11
11H11
6H22
8H22
11H22
2H34
4H11
6H11
11-1/4"
1/2" BSP
16-15/16"
1/2" BSP
22-5/8"
1/2" BSP
31-1/8"
1/2" BSP
16-15/16"
1/2" BSP
22-5/8"
1/2" BSP
31-1/8"
1/2" BSP
ADJUSTABLE
PEDESTAL
1/2" BSP
985 769 552
1,466
1,143
821
1,778
1,387
996
2,106
1,663
1,197
2,740
2,137
1,535
3,848
3,001
2,155
2,026
1,580
1,135
1,818
2,532
3,246
Btuh/FT at Listed AWT and EAT of 70
0
F.
W
4" Minimum
X
1-3/4"
3-3/8"
V11
H11/H22
H34
Measurement X:
chosen distance
between the wall or
window surface and
the back of the
convector.
6-9/16"
6-7/8"
X
3-1/2"
3-3/16"
Min
1-7/16"
3-1/8"
2H11BB
558
170
0
F
705
877
1,305
1,582
1,885
2,439
3,425
1,803
2,889
420
150
0
F
531
661
982
1,191
1,442
1,836
2,578
1,357
2,175
282
130
0
F
357
444
660
800
976
1,234
1,732
912
1,461
213
120
0
F
271
336
498
605
755
933
1,309
689
1,104
5.25
Weight
(lbs/ft)
7.62
9.75
13.34
17.57
22.54
24.82
32.94
42.38
16.08
.09
Wtr Content
gals/ft
.13
.18
.26
.36
.49
.54
.72
.99
.26
5V11
6V11
8V11
10V11
78-3/4"
1/2" BSP
1/2" BSP
1/2" BSP
1/2" BSP
4,009
3,127
2,245
4,018
3,134
2,250
4,018
3,134
2,250
2,247
3,130
4,013
3,568
3,576
3,576
3,572
2,686
2,692
2,692
2,689
1,804
1,808
1,808
1,806
1,363
1,366
1,366
1,365
49.52
49.52
49.52
49.52
1.12
1.12
1.12
1.12
4H34
1/2" BSP
2,593
1,862
2,959
2,228
1,497
1,132
31.20
.54
**100
**120
**140
**160 **180 **200 **220 **240
23-5/8"
31-1/2"
35-7/16"35-7/16"
47-1/4" 55-1/8"
63
" 70-7/8" 78-3/4" 86-5/8" 94-1/2"
Model Length **060 **080
Nominal Length
**090
**300
118-1/8"
39-3/8"
(cm)
(in)
3,324
5V11 6V11 8V11
10V11
14-1/8"
16-15/16"
22-5/8"
28-1/4"
V
E
R
TI
CA
L
MODELS
ADJUSTABLE
PEDESTAL
78-3/4"
78-3/4"
78-3/4"
Connections
2 per side
DECOR SERIES
Specification Data
X
Mounting
Bracket
3
Dimension (in)
Dimension (in)
XWW
Type H11 Typ
e H22
1
5
/
16
4
7
/
8
3
1
/
16
3
3
/
8
1
11
/
16
5
1
/
4
3
7
/
16
KOM (BH)
Short Side*
KOM (BH)
Long Side*
* From wall to radiator
  • Page 1 1
  • Page 2 2

Myson H11 8 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI