Myson Column Radiator Installation guide

Type
Installation guide

Myson Column Radiator is a technologically advanced radiator with a sophisticated design made for efficient heating. Its compact design and solid steel construction with a durable baked epoxy/polyester enamel powder coat finish, make it a reliable heating solution. The sleek styling and thorough testing provide attractiveness and dependability, assuring high performance, quality, and outstanding customer service.

Myson Column Radiator is a technologically advanced radiator with a sophisticated design made for efficient heating. Its compact design and solid steel construction with a durable baked epoxy/polyester enamel powder coat finish, make it a reliable heating solution. The sleek styling and thorough testing provide attractiveness and dependability, assuring high performance, quality, and outstanding customer service.

MYSON
MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK
T: 0845 402 3434, F: 0191 491 7568, [email protected], www.myson.co.uk
01.11.2011
heatingthroughinnovation.
MYSON
heatingthroughinnovation.
Column Radiator Series
Installation & Technical Guide
02
COLUMN.
MYSON COLUMN radiator's aesthetically sophisticated design was conceived for
technologically superior heating. Their design form makes them suitable for a wide range
of architectural applications from retro to modern.
Contents/Warranty
03
04
05
06
07
08
12
Kontec
Basics
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the
duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If
replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a
similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation
and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic
electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power
line voltage, mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims
MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS -- SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
Painted finishes will not peel or flake from the surface of the radiator
The body of the radiator and its welded joints will not leak when the product is properly installed and maintained
according to Myson's instructions.
What is not covered:
Rust occurring from improperly sealed threaded connections or oxygen corrosion
Electrolytic corrosion caused by failure to flush the system properly after initial installation
Contents
What is covered:
Important information
Product description
Model overview / connection dimensions
Piping & rough-in
Wall bracket position information
Optional Floor bracket information
Heating outputs / weights / water content
Piping arrangements
Valve selection
Heat output factors / System start - up
13
9 - 10
11
Important Information 03
BEFORE YOU BEGIN
SAFETY PRECAUTIONS
Rad
iators are hot when in use, and as such, present a
risk of burns
to
users
on
prolonged
contact.
The
temperature
of
a
radiator
is
dependent
on
the
temperature
of
the
system
water,
as
set
by
the
system installer or user. Installers and users
should ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installers
and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be
given to installing low surface temperature radiators, or to placing guards in front of the radiators.
For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way
that it is suitable for intended use AND predictable misuse. A number of elements
need to be taken into
consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall
itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to
finalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED
PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
INTRODUCTION
The Myson Column Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the
Column Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked
epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness and
dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTION
Step 1 Read this entire instruction manual thoroughly before beginning installation.
Step 2 To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all
the instructions carefully .
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATION
Myson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom-
mended for gravity systems. DO NOT USE STEAM IN THESE RADIATORS.
INSPECT FOR DAMAGE
NOTE: Inspect materials for concealed shipping damage. You only have 10 days to file a freight claim. If items are
damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESS
Unpack the radiator carefully to avoid damage or loss of parts. The Column Radiator will come with the following parts:
Wall mounting bracket kit
Plastic inserts for noise suppression
Stainless steel solid plug
Vent plug
IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL
INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough;
however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade
practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/
herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the
Myson product used.
DESIGN AND LAYOUT CONDITIONS
Myson Column Radiators should only be used with a properly sized recirculation pump closed loop hydronic heating system.
Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator
away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that
could draw air into the system. The preferred positioning for the Column radiator is below a window where it can minimize
downdrafts from glazed areas.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Radiators
2 - COLUMN:
Standard Heights: 18, 24, & 79 inches (45, 60, & 200 cm)
Coatings:
1. Undercoat: electrophoretic, using water-soluble paints,
conforming to
DIN 55900 part 1, stoved at 329
° F;
2. Finish: electrostatic powder coating, conforming to DIN 55900 part 2,
i
n a state-of-t
he-art facility. (On request, and at a supplementary charge,
a range of RAL and sanitary ware colours can be offered.) This
particularly
r
obust coating is stoved at an object temperature of
356
°
F
.
Packaging: 1. Cardboard packaging
2. Edge protection
3. Shrink foil
COLUMN product description
Quality certificates
MYSON offers its customers strong
brands that meet highest quality
standards. All the production sites’
production processes are certified ac-
cording to ISO. The quality and perfor-
mance specifications of the convectors
and heating panels have been verifi ed
by recognised European institutions.
The standards that the quality certifi -
cates require us to maintain give you
security, the best heating performance
and premium product quality. For the
MYSON warranty conditions, please
refer to the table of contents page of
this manual.
Strong brands of the highest quality
Connections:
4 x internal thread G 1/2“ BSP,
welded-in for supply and return.
Vent and drain plugs (or dummy
plug) are included
Maximum positive
operating pressure:
145 psi
Maximum operating
temperature:
max.
72psi
max.
04
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
PRODUCT DESCRIPTION
12 - 3045
Overall Height [cm]
Number of Columns
Number of Sections
Additional sizes and models are available as special order
Tested to positive
pressure:
188.5 psi
248° F
Manufacture
MYSON COLUMN radiators are
manufactured using a unique
laser
welding proce
ss that virtually eliminates
the visible
welding
points
associated
with
the
traditional
methods
of
manufacturing
this
type
of
radiator.
The
clean
finish
significantly
enhances
the
aesthetic qualities of the radiator.
Tube Details
Precision, D-
profile steel
tube is used
for
all
outside
surfaces
which
ensures
high
outputs
and
soft,
rounded
edges
for
maximum
safety.
All
MYSON
COLUMN
radiators are
manufactured and tested to EN 442.
Paint Finish
Every MYSON COLUMN radiator
undergoes a multi-stage pre-treatment
process followed by an epoxy polyester
primer coating. A stoved epoxy
polyester
powder coat in white (RAL
9016) is applied to all front and rear
surfaces allowing
the MYSON
COLUMN to be fitted without further
painting.
MYSON COLUMN radiators carry a 5 year
guarantee against defects caused by
faulty materials or manufacture.
3 - COLUMN:
Standard Heights: 12, 18, & 24 inches (30, 45, & 60 cm)
4
-
COLUMN:
Standard Height
:
24
inches
(60 cm)
See pages 9 & 10 for standard number of sections and outputs
ABOVE EXAMPLE:
12 Sections, 3 Column, 18"High
10
10
10
COLUM
N model overview / connection dimensions
Dimension and Mounting Quick Reference
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
05
Length equals the number of
sections times 2"
Example:
56 sections times 2"
equals 112"
2"
1"
1 1/4"
1 1/4"
All tappings are 1/2" BSPT
C
L
LKD16AN
C
L
1 3/4"
1 3/4"
Shown with DAV12 and
LKD16AN valves. See page 12
for additional valve choices .
DAV12
4"
3/4"
1-3/16"
2-5/16"
3-1/4"
5/8"
2"
1/2"
Position 2
Position 1
Column Radiator Wall Brackets
4 Column
5
1
/2"
3 Column
4"
2 Column
2
1
/2"
Pipe centers from finished wall are
dependent on which mounting slot is
selected on the mounting bracket and
the number of columns.
2 Column 3 Column 4 Column
Position 1 Min: 2
1
/
2
"
3
1
/
4
"
4"
Position 2 Max:
2
7
/
8
"
3
5
/
8
"
4
3
/
8
"
To obtain pipe centers using Myson
valves multuply the number of
sections by 2" and add 3.5".
Example: A 12 section radiator would
be 12 x 2"+ 3.5" = 27.5"
MYSON COLUMN RADIATOR
ROUGH -IN SPECIFICATIONS
COLUMN piping & rough-in
Standard models
Suitable for mono-flo, home run or 2-pipe systems
Rough-in dimension shown at right is for a TRV and a
LKD valve or a pair of LKD valves.
When using FF valves add 3-5/8" to overall length.
Recommendation:
Radiator tappings and valve spuds are 1/2"BSP.
Professional expertise is required when sealing these
"straight" threads. Failure to properly seal the
connections will result in leaks resulting in property
damage.
NOTE ! Myson is not responsible for damage resulting from improper workmanship.
NOTE ! Rough-in information is given for Myson control valves. Valve specifications vary by manufacturer.
Myson will not be responsible for damage or repair of property resulting from the use of non-Myson valves.
06
Overall Length + 3-1/2"
LKD16AN
FF16WAC
TRV
All installations require 2 valves per radiator
All valves are ½” BSP thread for connection to the
radiator and ½”
NPT thread for connection to the
system (also includes compression nut and ferrule
for connection to ½” copper)
Valves are available in 3 basic patterns: angle,
straight, and inverted angle (TRV only)
Basic Installation: use 2 – LKD16AN (angle) or
LKD16SN (straight) manual
valves, nickel plated with
screwdriver stops and caps
Basic upgrade: use 1 - FF16WAC and 1 - FF16LAC
manual valves, angle only, chrome plated with white
handles (FF16WAC
is adjustable for balancing,
FF16LAC is fixed open but can be closed for service)
TRV (thermostatic radiator valves) are available for
automatic temperature control of individual radiators:
available in 3 body patterns, with or without
thermostatic
head (sensor), use in conjunction with
LKD or FF
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
NOTE: See page 5 or 7 for rough-in from finished
wall to pipe centers.
See page 12 for additional valve information
A
ll MYSON COLUMN radiators
are ordered without an internal
baffle. This will not effect the
output of the radiator except in
cases where the radiator is less
than 4 sections long or is a 2
column radiator less than 8
sections long. These smaller
radiators should be ordered with
a baffle in the supply position.
Contact MYSON Tech Support for
more information.
MYSON COLUMN radiators are suitable for the use of
BBOE
(Bottom Bottom Opposite End), TBSE (Top
Bottom Same End) and
TBOE (Top Bottom Opposite
End) connections. TTOE (Top Top Opposite End)
connections cannot be used.
A
ll systems must be designed wi
t
h
suitable pipe sizing
and
w
i
t
h
adequate
pump
head. Failure to do this
m
ay lead to trapped air and cold spots because of
insufficient pressure and water flow will not drive the
air from the radiator. The taller and more tubes a
radiator has, the more likely this is to happen.
The installation work must be carried out with
precautions taken to avoid
contamination
which
could
lead
to
corrosion.
If
a
corrosion
inhibitor
or
other
water treatment is to be used, the
Manufacturer’s Instructions must be strictly followed.
The MYSON COLUMN radiator's large diameter
steel tube contruction ensures a negligible
pressure drop through the radiator. The pressure
drop through the radiator can be ignored in the
design of most hydronic systems.
Two-part cover for base-plate
in white plastic 106 x 128mm
2" 1
3
/
16
"
5
/
8
"
3
/
4
"
13
/
32
"
3
/
16
"
1
/
4
"
15
/
64
"
9
/
16
"
19
/
32
"
9
/
64
"
9
/
16
"
11
/
16
"
3
/
16
"
11
/
16
"
1
/
2
"
13
/
16
"
3
/
8
"
2
5
/
16
"
3
1
/
4
"
11
/
32
"
1
/
4
"
25
/
32
"
Radiator
Bracket
Angle Wall
Bracket
insert
Ensure tight
fit here
1
9
/
32
"
2
7
/
16"
7
/
16
"
A
(see table below)
25
/
32
"
1
3
/
16
"
7
/
16
"
3
/
4
"
1"
1
/
2
"
15
/
32
"
Wall &
Bracket
Wall &
Radiator
A = Distance between Wall & Center
Wall Bracket &
Radiator Bracket
25
/
32
"
7
/
16
"
1
7
/
32
" 2
1
/
2
" 3
1
/
4
"
4"
1
3
/
16
"
7
/
16
"
1
5
/
8
" 2
7
/
8
" 3
5
/
8
"
4
3
/
8
"
2 column 3 column 4 column
180
-
300mm
For use with
2-6 column radiators
8
26
120
40
26
60
100
Dimensions of base-plate for
Clamped Floor Bracket FK
( = base-plate cover)
91
75
104
8
116
Dimensions of base-plate
for Floor Bracket SK
Two-part cover for base-plate
in white plastic 110 x 135mm
Complete system for free-standing
radiators, from 2-6 column up to
1000mm height. Painted to
RAL 9016.
Comprises;
- 3mm thick base-plate fixing for
either finished or unfinished floor
Clamped Floor
Bracket FK
Order Code
For 2-6 Column Rads.
Base-Plate Cover
FK1021
COVERFK
Complete system for free-standing
radiators, from 2-6 column up to
1000mm height. Painted to RAL 9016.
Comprises;
- 3mm thick base-plate for fixing to
either finished or unfinished floor
- upright support 35 x 10 x 1.5mm,
fixing set with adjustable bracket,
security fixing, anti-vibration insert
- adjustable bottom support with
spacer and security fixing,
anti-vibration insert, white plastic
end stop for top of upright.
Height of
Upright
Order Code
460
610
760
910
Base-Plate Cover
Height of
Radiator
300
450
600
750
SK20046
SK20061
SK20076
SK20091
COVERSK
Operating Pressures
Every MYSON COLUMN radiator is tested to a pressure of
13 bar (188.5 psi) and is suitable for a working pressure of up to
10 bar (145 psi).
20
10
30
Radiator Brackets
Floor Bracket SK
Mounting Brackets (supplied with every radiator) - Wall Brackets
Fixing Brackets - Clamped Floor Bracket FK
COLUMN Mounting Bracket Detail
COLUMN Technical Information
09
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
07
50 30
16 20
10.5
5
6.5
6
14
15
3.6
14
18
4.5
17 12
20.5
34.5
59 83
8.5
6
20
Radiator
Bracket
Angle Wall
Bracket
insert
Ensure tight
fit here
32.5
62
11
A
(see table below)
20
30
11
19
25
13
11.5
Wall &
Bracket
Wall &
Radiator
A = Distance between Wall & Centre
Wall Bracket &
Radiator Bracket
20mm 11mm 31mm 62.5 81.5 100.5
30mm 11mm 41mm 72.5 91.5 110.5
Connections
All MYSON COLUMN radiators are fitted with 4 x 1/2 inch
BSP connections.
Radiators include plug and vent.
Radiators are manufactured with an internal baffle. The tapping
with the baffle is identified with a red plastic cap, all others being
blue. It is important that the water inlet is connected to the
tapping identified in red.
N.B. The radiator is suitable for the use of BBOE (Bottom Bottom
Opposite End), TBSE (Top Bottom Same End) and TBOE (Top
Bottom Opposite End) connections. TTOE (Top Top Opposite
End) connections cannot be used.
2 column 3 column 4 column
3
9
/
16
"
2
15
/
16
"
4
3
/
32
"
5
/
16
"
Dimensions of base-plate
for Floor Bracket SK
Two-part cover for bas
e
-plate
i
n
white plastic 4
5
/
16
" x 5
5
/
16
"
Complete system for free-standing
radiators, from 2-6 column up to
1000mm height. Painted to RAL 9016.
Includes:
- 3mm thick base-plate for fixing to
either finished or unfinished floor
- upright support 35 x 10 x 1.5mm,
fixing set with adjustable bracket,
security fixing, anti-vibration insert
- adjustable bottom support with
spacer and security fixing,
anti-vibration insert, white plastic
end stop for top of upright.
Height of
Upright
Order Code
18"
24"
30"
Base-Plate Cover
Height of
Radiator
12"
18"
24"
Radiator Brackets
Floor Bracket SK (Optional)
Fixing Brackets (supplied with every radiator) - Wall Brackets
08
COLUMN Technical Information
COLUMN Floor Bracket Detail
4
9
/
16
"
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
The table on the right gives
recommendations for the
number of brackets to be used
with each radiator.
The strength of the wall should
be checked for its load-bearing
capabilities before installation.
Type
2 to 4 Column
Number of Sections
0 - 20
21 - 40
4 6
Up to 39” Height: Wall -
Mounted Angle Brackets - RW
Radiator Bracket - RH
4
6
Floor Mounting Floor
bracket - SK
2 3
4 6
Over 39” Height: Wall -
Mounted Angle
Brackets - RW
Radiator Bracket - RH
4
6
08
4,
4,
4,
KOM-ASK2
Height
24in
Height
18in
Height
79in
Architecture Range - Bench Radiator
Accessories
4 COLUMN
Height
1
2in
Height
1
8in
Height
2
4in
Height
24in
H
L
Special order only.
The Bench Radiator is
sold complete, but can be
sold seperately if required.
4 COLUMN3 COLUMN2 COLUMN
2
1
/
2
in
4in
5
1
/
2
in
Micro Fibr
e Cleaning Brush
Product Code: COLUMNBRUSH2
Towel Rail
Clip-on rail to fit all
radiators up to 1m
long (20 sections)
Product Code: 12SECRAIL
16SECRAIL
20SECRAIL
Decorative Foot
Product Code: COLDECFOOT
Fixing Brackets
Product Code: FK1021
Product Code: COVERFK
Floor Brackets
Product Code: SK20046
Product Code: SK20061
Product Code: SK20076
Product Code: SK20091
Product Code: COVERSK
COLUMN Sizes & Outputs
COLUMN Sizes & Outputs
11
Length inc. seat Height inc. seat Depth inc. seat Output Output
Order Code
(mm - inches) (mm - inches) (mm - inches) (watts) (Btu/h)
1850 - 73 472 - 19 365 - 14 1489 5080 23 SEC 056150
1850 - 73 522 - 21 365 - 14 1738 5930 23 SEC 066150
2150 - 85 472 - 19 365 - 14 1816 6196 23 SEC 056180
2150 - 85 522 - 21 365 - 14 2119 7230 23 SEC 066180
2350 - 93 472 - 19 365 - 14 2053 7005 23 SEC 056200
2350 - 93 522 - 21 365 - 14 2396 8175 23 SEC 066200
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
NOTES:
1. All dimensions are nominal.
2. Heat outputs are based on 180
0
F AWT
and 68
0
F EAT (mean water to air
temperature of 112
0
F)
3. For heat outputs at other temperatures see page 13.
2 COLUMN
No. of Sections
Weight (lbs)
Ou
tput (Btu/h)
Order Code
12
19.8
12 - 2045
16
26.5
16 - 2045
20
33.0
20 - 2045
24
39.6
24 - 2045
28
46.2
28 - 2045
36
59.4
36 - 2045
12
25.9
12 - 2060
16
34.6
16 - 2060
20
43.2
20 - 2060
24
52.0
24 - 2060
28
60
.5
28 - 2060
6
41.4
6 - 2200
8
55.2
8 - 2200
10
69
.0
10 - 2200
12
82.8
12 - 2200
15
103.5
15 - 2200
Water Content (gals)
1.68
2.24
2.80
3.36
3.92
5.00
2.10
2.80
3.50
4.20
4.90
3.00
4.02
5.02
6.02
7.53
Length (in)
3 COLUMN
No.
of Sections
Weight (lbs)
Output (Btu/h)
Order Code
32
16
27.5
2380
16 - 3030
40
20
34.4
2975
20 - 3030
56
28
48.2
4265
28 - 3030
72
36
62.0
5355
36 - 3030
24
12
29.6
2674
12 - 3045
32
16
39.5
3565
16 - 3045
40
20
49.4
4456
20 - 3045
48
24
59.3
5347
24 - 3045
56
28
69.3
6239
28 - 3045
24
12
41.4
3566
12 - 3060
32
16
55
.2
4
755
16 - 3060
40
20
69
.0
5944
20 - 3060
48
24
82
.
8
7132
24 - 3060
56
28
103.5
8321
28 - 3060
Water Content (gals)
2.42
3.02
4.23
5.44
2.41
3.22
4.02
4.83
5.63
3.
00
4.
02
5.
0
2
6.
0
2
7.5
3
Length
(in)
72
36
88.9
8021
36 - 3045
7.24
No.
of Sections
Weight (lbs)
Output (Btu/h)
Order Code
24
12
51.6
4
213
12 - 4060
32
16
68.8
5618
16 - 4060
40
20
86.0
7022
20 - 4060
48
24
103.2
8
426
24 - 4060
Water Content (gals)
4.00
5.33
6.67
8.00
Length (in)
09
24
1847
32
24
62
40
3078
48
3
693
56
4309
72
5540
24
2448
32
3265
40
4081
4
8
4897
56
5713
12
4041
16
5388
20
6735
24
8082
30
10103
Height
600 mm
Height
450 mm
Height
2000 mm
2 COLUMN
Architecture Range - Bench Radiator
3 COLUMN
4 COLUMN
Height
300 mm
Height
450 mm
Height
600 mm
Height
750 mm
Height
600 mm
Height
750 mm
4 COLUMN3 COLUMN2 COLUMN
63
mm
101
mm
139
mm
Floor Brackets
Product Code: SK20046
Product Code: SK20061
Product Code: SK20076
Product Code: SK20091
Product Code: COVERSK
10
COLUMN Sizes & Outputs
BEN
CH Sizes & Outputs
Length (mm - inches) No. of Sections Output (watts) Output (Btu/h) Order Code
600 - 24 12 435 1485 12 SEC 2045
800 - 32 16 580 1980 16 SEC 2045
1000 - 40 20 725 2474 20 SEC 2045
1200 - 47 24 870 2969 24 SEC 2045
1400 - 55 28 1015 3464 28 SEC 2045
1800 - 72 36 1305 4454 36 SEC 2045
600 - 24 12 564 1925 12 SEC 2060
800 - 32 16 752 2567 16 SEC 2060
1000 - 40 20 940 3209 20 SEC 2060
1200 - 47 24 1128 3850 24 SEC 2060
1400 - 55 28 1317 4492 28 SEC 2060
300 - 12 6 881 3006 6 SEC 2200
400 - 16 8 1175 4008 8 SEC 2200
500 - 20 10 1468 5010 10 SEC 2200
600 - 24 12 1762 6012 12 SEC 2200
750 - 30 15 2202 7515 15 SEC 2200
Length (mm - inches) No. of Sections Output (watts) Output (Btu/h) Order Code
800 - 32 16 566 1933 16 SEC 3030
1000 - 40 20 708 2416 20 SEC 3030
1400 - 55 28 991 3382 28 SEC 3030
1800 - 71 36 1274 4348 36 SEC 3030
600 - 24 12 606 2068 12 SEC 3045
800 - 32 16 808 2757 16 SEC 3045
1000 - 40 20 1010 3446 20 SEC 3045
1200 - 47 24 1212 4135 24 SEC 3045
1400 - 55 28 1414 4825 28 SEC 3045
1800 - 72 36 1818 6203 36 SEC 3045
600 - 24 12 781 2665 12 SEC 3060
800 - 32 16 1042 3554 16 SEC 3060
1000 - 40 20 1302 4442 20 SEC 3060
1200 - 47 24 1562 5331 24 SEC 3060
1400 - 55 28 1823 6219 28 SEC 3060
600 - 24 12 935 3251 12 SEC 3075
800 - 32 16 1270 4335 16 SEC 3075
1000 - 40 20 1588 5418 20 SEC 3075
1200 - 47 24 1906 6502 24 SEC 3075
1400 - 55 28 2223 7586 28 SEC 3075
Length (mm - inches) No. of Sections Output (watts) Output (Btu/h) Order Code
600 - 24 12 997 3402 12 SEC 4060
800 - 32 16 1330 4537 16 SEC 4060
1000 - 40 20 1662 5671 20 SEC 4060
1200 - 47 24 1994 6805 24 SEC 4060
1400 - 55 28 2327 7939 28 SEC 4060
600 - 24 12 1214 4144 12 SEC 4075
800 - 32 16 1619 5525 16 SEC 4075
1000 - 40 20 2024 6906 20 SEC 4075
1200 - 47 24 2429 8287 24 SEC 4075
1400 - 55 28 2834 9668 28 SEC 4075
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
No.
o
f Sections
Weight (lbs)
Output (Btu/h)
Order Code
53 x 19 x 14
5
75
3528
23-05-6100
53 x 21 x 14
6
8
7
4231
23-06-6100
61 x 19 x 14
5
85
4185
23-05-6120
61 x 21 x 14
6
99
5022
2
3-06-6120
73 x 19 x 14
5
1
46
6452
23-05-6150
73 x 21 x 14
6
1
61
7530
23-06-6150
85 x 19 x 14
5
1
72
7868
23-05-6180
85 x 21 x 14
6
1
90
9182
23-06-6180
9
3 x 19 x 14
5
1
86
8895
23-05-6200
Water Content
(gals)
3.75
4.49
4.41
5.28
4.52
6.50
5.34
7.64
5.90
Dimensions (in)
LxHxW
93 x 21 x 14
6
2
05
10383
23-06-6200
8.42
3"
1
3
/
8
"
Thermostat
H
14
9
/
16
"
11
13
/
16
"
5
5
/
16
"
A
15
/
16
"
5
5
/
16
"
1
3
/
16
"
2
3
/
4
"
2
15
/
16
"
3
15
/
16
"
Thermostat
1
/
2
" Valve Body
Detail "A"
Y
Radiator Length + 13
3
4
"
Technical Data
Radiator Length - 2
9
/
16
"
Radiator Lenth + 1
3
/
8
"
3
15
/
16
"
NOTE: All dimensions are nominal.
Radiator Length
39
3
/
8
39
3
/
8
47
1
/
2
47
1
/
2
59
1
/
16
59
1
/
16
70
7
/
8
7
0
7
/
8
78
3
/
4
78
3
/
4
Rough - in (cc)
36
13
/
16
36
13
/
16
44
11
/
16
56
1
/
2
68
5
/
16
76
3
/
16
(in)
(in)
44
11
/
16
56
1
/
2
68
5
/
16
76
3
/
16
X
10
Typical hydronic system types
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
11
The following drawings are general examples.
Consult a certified heating professional for your specific application.
RADIATOR optional piping arrangements
RADIA
TOR valve selection
Valve application
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
12
All installations require 2 valves per radiator
All valves are ½” BSP thread for
connection to the radiator and
½” NPT thread for connection to the system (also includes compression nut
and ferrule for connection to ½ copper
Valves are available in 3 basic patterns: angle, straight, and inv
erted angle (TRV only)
Basic Installation: use 2 – LKD16AN (angle)
or LKD16SN (straight)
manual valves, nickel plated with screwdriver stops and caps
Basic upgrade: use 1 FF16WAC and 1 – FF16LAC manual valves, angle
only, chrome plated with white handles (FF16WAC is adjustable for
balancing, FF16LAC is fixed open but can be closed for service)
TRV (thermostatic radiator valves) are available for
automatic temperature control of individual
radiators: available in 3 body patterns, with or without thermostatic head (sensor), use in conjunction
with LKD or FF
TRV remote sensors and adjusters
available for special applications
DCK12 – 4 chrome nipple with
compression connection available for use with all Myson valves,
includes escutcheon (connects valve to heating system)
D
A
V
1
2
– same as
DCK12
with addition of integral ball stop angle valve
D
e
co
rative pipe covers and
e
scutcheo
ns
available in chrome or white (use
to cover exposed copper pipe used in radiator installation)
LKD16AN LKD16SN FF16WAC FF16LAC TRVanglew/HEAD
RemoteSensorRemoteAdjuster TRVstraight TRVinvertedangle TRVHEADonly
DCK DAV
C
O
LUM
N C
onversion
F
a
ct
ors / Start-up & Maintenance
Heat output factors / Start - up and Maintenance
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
13
Failure to flush system of debris and flux may cause premature radiator failure, which
can result in leaks and property damage NOT covered under the Myson Warranty.
Step 1 Fill and vent the system.
Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position.
Step 3 Shut off and drain the system while the water is still hot.
Step 4 Refill the system.
Step 5 Reheat, vent, and balance the system.
Step 6 Once the Décor Radiator is filled with water the system should be left filled.
Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking radiators
internally.
SYSTEM START-UP
MAINTENANCE &
CLEANING
1
Once
operating,
avoid
the introduction of fresh water and oxygen to the system to prevent corrosion.
2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your
Myson Décor Panel Radiator.
3 The use of abrasive cleaners will damage the surface of your radiator and void the
manufacturer’s warranty.
Heat Output
The heat outputs for all MYSON COLUMN radiators can be found on pages 9 and
10. The tabulated figures are quoted in accordance with EN 442 for a mean water to
air temperature of 112
0
F. This is based on an average water temperature of 180
0
F
and an ambient air temperature of 68
0
F. When the difference is not 112
0
F, the
output should be multiplied by the appropriate factor from within the table below:
Aver. Water Temp.
0
F
Ambient Air Temp.
0
F
190 68
180 68
170 68
160 68
150
68
140 68
120 68
Water to Air
(D
elta T
0
F)
Conversion Factor
122
1.14
112 1.00
102
.91
92 .79
82
.68
72
.58
52
.38
N
O
TES
Notes
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
14
N
O
TES
Notes
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
15
heatingthroughinnovation.
MYSON
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
COLUMN 7/2016
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Myson Column Radiator Installation guide

Type
Installation guide

Myson Column Radiator is a technologically advanced radiator with a sophisticated design made for efficient heating. Its compact design and solid steel construction with a durable baked epoxy/polyester enamel powder coat finish, make it a reliable heating solution. The sleek styling and thorough testing provide attractiveness and dependability, assuring high performance, quality, and outstanding customer service.