Commercial Electric 54599141 Installation guide

Type
Installation guide

This manual is also suitable for

Commercial Electric 54599141 offers versatile lighting solutions for both indoor and outdoor settings. With its IP65 waterproof rating, it withstands harsh weather conditions, making it ideal for gardens, patios, or workshops. Its durable construction ensures longevity even in demanding environments. Whether you need focused illumination for tasks or ambient lighting for gatherings, this product delivers reliable performance.

Commercial Electric 54599141 offers versatile lighting solutions for both indoor and outdoor settings. With its IP65 waterproof rating, it withstands harsh weather conditions, making it ideal for gardens, patios, or workshops. Its durable construction ensures longevity even in demanding environments. Whether you need focused illumination for tasks or ambient lighting for gatherings, this product delivers reliable performance.

Ordering # 54599142
Part # ST-8-90-840-SV-N
Certification # 54599142
USE AND CARE GUIDE
LED STRIP LIGHTS
PACKAGE CONTENTS
Part Description Quantity
A Lens Cover 1
B Fixture Body 1
HARDWARE INCLUDED
Part Description Quantity
AA Toggle Bolt 2
BB S Hook and Chain 2
CC S Hook 2
The hardware kit for surface mounting is sold as a separate accessory. Please contact ETiSSL Customer Service 1-855-384-
7754 for additional information. Ordering # 54657102 (Required for surface mounting).
NOTE: Keep your receipt and these instructions for proof of purchase.
WARNING: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the
fuse or turn off the circuit breaker before removing an existing light fixture or installing the new one.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
INSTALLATION
Select a suitable location that can support the weight of the fixture. Determine the method for mounting the fixture before
drilling, based on the type of ceiling.
1. With power disconnected to the electrical box, remove the existing fixture. Make a sketch of how the current fixture is wired
(by wire color) or mark the wires with masking tape and a pencil so you will know how to properly reconnect the wires to
the new LED light fixture.
AA BB
A
CC
B
2. Press the sides of the fixture body (B) inward, in the direction of the arrows, and remove the lens cover (A) with the other
hand.
3. After separating the lens cover (A) from the fixture body (B), unplug the wire connectors to disconnect the terminal and
ground wires.
4. Remove the safety rope from both ends of the fixture body (B).
5. Hold the fixture body (B) up to the mounting surface to determine which knock out hole to use for wiring the fixture.
SURFACE MOUNTING
1. Mark two keyhole locations on the mounting surface. Using a screwdriver, punch out one of the five large knock out holes
in the fixture body (B) for wiring, based on the installation position. Drill a 1/8-in. pilot hole into the screw locations marked
on the ceiling. You can also use an awl or nail to dimple the screw holes. Install a drywall anchor (BB) and a mounting screw
(AA) in each drilled mounting hole, but do not tighten fully.
2. Feed the electrical wires from the electrical box through the center of the electrical box plate (not included). Secure the
electrical box plate (not included) to the electrcial box with the mounting screws (not included).
3. Feed the electrical wires from the electrical box through the open knock out hole in the fixture body (B).
4. Align the two mounting keyholes on the fixture body (B) with the two mounting screws (AA) in the ceiling.
5. Once the screw heads are through the large ends of the keyholes, slide the fixture body (B) to the left until the heads of the
mounting screws (AA) slide into the narrow ends of the keyholes.
6. Finish tightening the mounting screws (AA) until the fixture body (B) is tightly secured to the mounting surface.
7. Reattach the safety ropes to the fixture body (B).
8. Insert the hot and neutral (black and white) wires from the electrical box into the wire connectors of the same color wires
from the fixture body (B).
A
B
75” (1904 mm)
0.5” in. Diameter
AA
Keyholes
B
9. Insert the ground wire from the electrical box into the wire connector attached to the green wire from the fixture body (B).
10. Reconnect the terminal and ground wires with the attached wire connectors.
11. Snap the lens cover (A) onto the fixture body (B).
12. Restore the power to the electrical box.
SUSPENSION MOUNTING
Mounting to drywall
1. Determine the position for the two toggles to be secured in the drywall mounting surface.
A. Drill two holes large enough to clear the closed flaps of the butterfly nut on the toggle bolt (not included). Make sure to
fasten the toggle bolt into the butterfly nut before inserting the flaps into the ceiling.
B. Tighten the toggle bolt.
B
Wire Connectors
Safety
Cable
A
Mounting to wood
2. Drill two 1/16 in. diameter holes in the ceiling to accommodate hook screws (not included). Make sure to fasten the combo
wood-machine end into the metal hook.
A. Tighten the hook screws (not included) into the wood.
B. Attach the S hook at the bottom of the mounting chain (BB) to the fixture body (B). Repeat this step on the other side of
the fixture.
3. Hang the fixture body (B) by placing one chain over each hook (not included) that has been installed on the ceiling.
4. Adjust chains to level light.
5. Feed the electrical wires from the electrical box through the appropriate conduit based on local electrical code and then
through a pipe clamp (not included) and through the open knock out hole in the fixture body (B).
6. Reattach the safety ropes to the fixture body (B).
7. Insert the hot and neutral (black and white) wires from the electrical box into the wire connectors of the same color wires
from the fixture body (B).
8. Insert the ground wire from the electrical box into the wire connector attached to the green wire from the fixture body (B).
9. Reconnect the terminals to the wire connectors.
10. Snap the lens cover (A) onto the fixture body (B).
11. Restore the power to the electrical box.
Keyholes
73.7”(1872mm)
Wire Connectors
BB
CC
B
BB
BB
L
N
G
L
N
G
L
N
G
L
N
G
B
B
Jumper Wires
CONTINUOUS MOUNTING
1. Using a screwdriver, punch out the knock out hole on the sides of both fixture bodies (B).
2. Place the ends of the fixture bodies (B) together.
3. Insert either a 1/2 in. threaded coupler (not included) through both knock out holes and secure coupler with 2 threaded nuts
(not included) or insert flexible metal conduit with a snap-in connector through both knock out holes to connect the fixture
bodies (B).
4. Run jumper wires (not included) through the threaded coupler or use the wires in the metal conduit to connect the hot and
neutral (black and white) wires from one fixture body (B) to the next.
NOTE: Multiple light fixtures can be
connected, up to a maximum of 4 Lights. Do not
exceed 360 total watts for interconnected lights.
Questions, problems, missing parts?
Call ETiSSL Customer Service
8 a.m. - 5 p.m., CST, Monday - Friday
1-855-ETI-SSLI (1-855-384-7754)
www.ETiSSL.com
Problem Possible Cause Solution
The fixture will not light. The power is off. Ensure the power supply is on.
The circuit breaker is off. Ensure the circuit breaker is in the on position.
There is a bad connection. Check to ensure proper wire connections are made. Contact a
qualified electrician.
There is a defective switch. Contact a qualified electrician.
The fuse blows or the
circuit breaker trips when
the light is turned on.
The wires are crossed or the
power wire is grounding out.
Check the wire connections. Contact a qualified electrician or call
customer service 1-855-384-7754.
CARE AND CLEANING
CAUTION: Before attempting to clean the tube and luminaire/light fixture, disconnect the power to the fixture by turning
the breaker off or removing the fuse from the fuse box. Clean with a soft, dry cloth. Do not use cleaners with chemicals,
solvents, or harsh abrasives. Do not use liquid cleaner on the LEDs, LED driver, or wiring.
TROUBLESHOOTING
Minor problems often can be fixed without the help of an electrician.
WARNING: Before doing any work on the fixture, disconnect power to the light fixture.
WARNING: Carefully read and understand the information given in this manual before beginning the assembly and
installation. Failure to do so so could lead to electric shock, fire, or other injuries which could be hazardous or even fatal.
• Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
This product must be installed in accordance with the applicable installation codes by a person familiar with the
construction and operation of the product and the hazards involved. • Risk of electrical shock. To reduce the possibility of
serious injury, always take the proper precautions and unplug the fixture before moving or cleaning.
NOTICE: Suitable for operation in ambient temperatures not exceeding 113°F/45°C.
NOTICE: Suitable for damp locations.
NOTICE: Do not use this fixture with a dimmer switch.
NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures: Reorient or relocate the receiving antenna, increase the separation between the equipment and
the receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, and consult
the dealer or an experienced radio/TV. Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
WARRANTY
This product is warranted for a period of 5 years from the date of original purchase against defects in materials and
workmanship. If this product should fail to operate due to defects in material or workmanship within 60 months of purchase, see
www.ETiSSL.com for details. This product will be repaired or replaced, at ETi’s option. This warranty is expressly limited to repair
or replacement of product and liability for direct, incidental, or consequential damages is hereby expressly excluded. Some
states do not allow exclusions of direct, incidental or consequential damages, so the above limitation of exclusion may not apply
to you. This warranty gives the consumer specific legal rights, which vary from state to state. WARRANTY IS VOID IF PRODUCT IS
NOT USED FOR THE PURPOSE WHICH THIS PRODUCT IS MANUFACTURED.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Commercial Electric 54599141 Installation guide

Type
Installation guide
This manual is also suitable for

Commercial Electric 54599141 offers versatile lighting solutions for both indoor and outdoor settings. With its IP65 waterproof rating, it withstands harsh weather conditions, making it ideal for gardens, patios, or workshops. Its durable construction ensures longevity even in demanding environments. Whether you need focused illumination for tasks or ambient lighting for gatherings, this product delivers reliable performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI