Leviton VP0SR-10Z, VZ0SR-1L Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Leviton VP0SR-10Z Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
3-Way or More Applications (Multi-location)
Remote Devices
Cat. No. VP00R-10, Coordinating Dimmer Remote
Cat. No. VP00R-1L, Matching Dimmer Remote
Cat. No. VP0
S
R-10, Coordinating Switch Remote
Cat. No. VP0
S
R-1L, Matching Switch Remote
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,uorescentlighting,amotor-ora
transformer-operatedappliance.
• ForHi-lume
®
or Eco-10
®
(EcoSeries)electronicballastapplications,useinstructionsheetthatcomeswiththedimmerformulti-locationapplications.
• Vizia+™remotesarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziarf+™devicesformulti-location
switching.
WARNINGS AND CAUTIONS:
• Useonlyone(1)Vizia+™dimmerinamulti-locationcircuitwithupto9coordinatingremoteswithoutLEDsorupto4matchingremoteswithLEDs.Theremote(s)
willturnthelightonatthebrightnesslevelselectedatthedimmer.
• Recommendedminimumwallboxdepthis2-1/2".
• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
Tools needed to install your Remote:
Slotted/PhillipsScrewdriver ElectricalTape
Pliers Pencil
Cutters Ruler
INSTALLING YOUR REMOTE
NOTE:UsecheckboxeswhenStepsarecompleted.
Step 1
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER atcircuitbreakerorfuseandtest
thatpowerisoffbeforewiring!
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
3
5
1
2
6
4
2
4
1
5
3
4-Way
1. FirstTraveler–notecolor
2. SecondTraveler–tagged
3. Neutral
4. Ground
5. ThirdTraveler–notecolor
6. FourthTraveler–tagged
NOTE:Formatchingremote
w/LEDsinstallation,theFirst
TravelerbecomesLineHot.
3-Way
1. Line or Load (See important
instruction below)
2. Neutral
3. Ground
4. FirstTraveler–notecolor
5. SecondTraveler–notecolor
NOTE:Formatchingremote
w/LEDsinstallation,theFirst
TravelerbecomesLineHot.
Identifying your wiring application (most
common):
NOTE:Ifthewiringinthewallboxdoesnotresemble
anyofthesecongurations,consultaqualied
electrician.
Step 2
IMPORTANT:
For 3-Way applications,notethatoneofthescrewterminalsfrom
theoldswitchbeingremovedwillusuallybeadifferentcolor(Black)
orlabeledCommon.Tagthatwirewithelectricaltapeandidentify
asthecommon(LineorLoad)inboththedimmerwallboxand
remotewallbox.
For 4-Way applications,notethattheoldswitchbeingremoved
willhave4screwsplusagroundscrew.Tagthetwosamecolor
insulated wires with electrical tape.
3-Way Wiring with Matching Remote (w/LEDs)
Application:
NOTE: IncandescentandMagneticLowVoltage
installations only.
NOTE: Screw terminal dimmer depicted.
Step 4a
Coordinating Remote
Dimmer
BK
RD
YL/RD
T e rminal
Screw marked
Black (BK)
T e r mi na l
Scr ew mar ke d
Red ( RD)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
2
4
3
5
1
BK
RD
YL/RD
2
4
3
5
1
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD
YL/RD
RD
WH
RD
BK
BK
Black
not used
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
3-Way Wiring with Coordinating Remote (no LEDs)
Application:
NOTE: IncandescentandMagneticLowVoltage
installations only. NOTE: Screw terminal dimmer
depicted.
Step 4b
NOTE:ThedimmermustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallboxwith
a Line Hot connection and a Neutral connection. A Neutral wire to the
matchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft.
Wiring Matching Remote (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelertoremoteterminalscrewmarked“BK”
ortheBlackdimmerlead.
• SecondTravelerwallboxwirefromdimmertoremoteterminal
screwmarked“YL/RD”(note wire color).Thistravelerfromthe
remotemustgototheterminalscrewonthedimmermarked
“YL/RD”ortheYellow/Reddimmerlead.
• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.
Wiring Dimmer (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green dimmer lead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
dimmerterminalscrewmarked“RD”ortheReddimmerlead.
• FirstTravelerLineHottodimmerterminalscrewmarked“BK”orthe
Blackdimmerlead.
• RemoveRedinsulatinglabelfromterminalscrewmarked“YL/RD”
orYellow/Reddimmerlead.
• SecondTravelerwallboxwire(notecolorasabove)todimmer
terminalscrewmarked“YL/RD”ortheYellow/Reddimmerlead.
Thistravelerfromthedimmermustgototheterminalscrewonthe
remotemarked“YL/RD”.
• ProceedtoStep6.
Step 4d cont’d
Cut
(if necessary)
Preparing and connecting wires:
Thisremotecanbewiredusingsidewireterminal
screwsorthroughbackwireopenings.Choose
appropriatewirestrippingspecicationsaccordingly.
Step 3
Side Wire Connection
Side wire terminals accept
#14AWGsolidcopperwire
only.
Back Wire
(either hole may be used)
Backwireopeningsuse
#14-12AWGsolidcopperwireonly.
5/8"
(1.6 cm)
Strip Gage (measure bare wire here or
use gage on back of the dimmer)
• Makesurethattheendsofthewiresfromthewallboxarestraight
(cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
PK-93461-10-00-2A
Changing the color of your Device:
Yourdevicemayincludecoloroptions.Tochangecoloroftheface
proceedasfollows:
Push in side at tab
to release
Line up tabs and
press in sides one at
a time to attach
BK
RD
YL/RD
4
3
2
1
5
Dimmer
Matching Remote
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote (w/LEDs)
YL/RD
YL/RD
RD
WH
BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Step 2 cont’d
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
canbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green dimmer lead.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchtodimmerterminalscrewmarked"BK"orBlackdimmer
lead.
• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRed
dimmer lead (note wire color).Thistravelerfromthedimmermust
gototheterminalscrewontheremotemarked"RD".
• RemoveRedinsulatinglabelfromterminalscrewmarked
"YL/RD"orYellow/Reddimmerlead.
• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"or
Yellow/Reddimmerlead(note wire color).Thistravelerfromthe
dimmermustgototheterminalscrewontheremotemarked"YL/RD".
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:Maximumwirelengthfromdimmertolastremoteis
300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
terminalscrewmarked"BK".
• FirstTravelerwallboxwire(note color as above) to terminal screw
marked"RD".Thistravelerfromtheremotemustgototheterminal
screwonthedimmermarked"RD"orReddimmerlead.
• SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"YL/RD".Thistravelerfromtheremotemustgoto
theterminalscrewonthedimmermarked"YL/RD"orYellow/Red
dimmer lead.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulation
labelafxed.
NOTE:Ifinsulatinglabelisnotafxedtoterminalscrewmarked
"WH",useelectricaltapetocover.
• Proceed to Step 6.
3-Way Wiring with Matching Remote
(w/LEDs) for Controls with Neutral Connection
Application:
NOTE:ElectronicLowVoltage,Mark10™,QuietFan
Speed and Electronic Switch installations only.
NOTE: Dimmer is depicted.
Step 4c
4
3
5
Control
Matching Remote
Black
Green
White
Red
Yellow/Red
1
2
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Hot (Black)
Neutral (White)
ControlcMat hing Remote (w/LEDs)
YL/RD
Yellow/Red
Red
WH
BK
Black
Black
White
Load
Line
120VAC, 60Hz
White
Green
Ground
Green
Ground
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallboxwith
a Line Hot connection and a Neutral connection. A Neutral wire to the
matchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromcontroltoallinstalledremotes
cannotexceed300ft(90m).
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelertoterminalscrewmarked"BK"orBlack
dimmer lead.
• SecondTravelerwallboxwirefromcontroltoremoteterminalscrew
marked"YL/RD"(note wire color).Thistravelerfromtheremote
mustgototerminalscrewmarked"YL/RD"orYellow/Redcontrol
lead.
• LineNeutralwallboxtoremoteterminalscrewmarked"WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green control lead.
• Loadwallboxwireidentied
(tagged)whenremovingoldswitch
toterminalscrewmarked"RD"or
Red control lead.
• FirstTravelerLineHottoterminal
screwmarked"BK"orBlack
control lead.
• RemoveRedinsulatinglabelfrom
terminalscrewmarked"YL/RD"or
Yellow/Redcontrollead.
• SecondTravelerwallboxwire
(note color as above) to terminal
screwmarked"YL/RD"orYellow/Redcontrollead.Thistraveler
fromthecontrolmustgototheterminalscrewontheremote
marked"YL/RD".
• Lineneutralwallboxwiretoterminalscrewmarked"WH"or
White control lead.
• Proceed to Step 6.
Hot (Black)
Neutral (White)
ControlrCoo dinating Remote (no LEDs)
YL/RD
YL/RD
RD
White
Red
Black
Black
BKWH
White
Load
Line
120V A C, 60Hz
not used
not used
Green
Ground
Green
Ground
3-Way Wiring with Coordinating Remote (no
LEDs) for Controls with Neutral Connection
Application:
NOTE:ElectronicLowVoltage,Mark10™,Quiet
FanSpeedandElectronicSwitchinstallationsonly.
NOTE: Dimmer is depicted.
Step 4d
WIRING CONTROL:
Connect wires per WIRING DIAGRAM as follows:
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHot
Connection.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green control lead.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchtoterminalscrewmarked"BK"orBlackcontrollead.
• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRed
control lead (note wire color).
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"
orYellow/Redcontrollead.
• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"
orYellow/Redcontrollead(note wire color).Thistravelerfrom
thecontrolmustgototheterminalscrewontheremotemarked
"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhite
control lead.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteare
unused.Tightenbothscrews.
NOTE:Maximumwirelengthfromcontroltolastremoteis
300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitch
toFirstTraveler(note color as above).
• SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"YL/RD".Thistravelerfromtheremotemustgoto
theterminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked
"WH".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".
• Proceed to Step 6.
4-Way Wiring with Matching Remote (w/LEDs)
Application:
NOTE:IncandescentandMagneticLowVoltage
installations only.
NOTE: Screw terminal dimmer depicted.
Step 5a
BK
RD
YL/RD
BK
RD
YL/RD
4
3
2
1
5
Matching Remote
(3-Way Wall box from Step 2)
Matching Remote
(4-Way Wall box from Step 2)
Dimmer
(3-Way Wall box from Step 2)
4
3
5
Additional
Neutral Wire
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
White (WH)
6
2
1
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote
(w/LEDs)
Matching Remote
(w/LEDs)
YL/RD
YL/RD
YL/RD
RD
WHWH
BK
BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Green
Ground
NOTE:ThedimmermustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallbox
with a Line Hot connection and a Neutral connection. A Neutral wire
tothematchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft(90m).
WIRING MATCHING REMOTE (4-Way wall box with Line
Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• FirstTravelerandThirdTravelerwallboxwirefromdimmerin
the3-wayboxtoremoteterminalscrewmarked"BK"inthe
4-waybox,andtotheterminalscrewmarked"BK"ofthe
remainingremoteinthe3-waybox.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallbox
wirefromdimmerinthe3-wayboxtoremoteterminalscrew
marked"YL/RD"inthe4-waybox,andtotheterminalscrew
marked"YL/RD"oftheremainingremoteinthe3-waybox(note
wire colors).Thistravelerfromtheremotesmustgotothe
terminalscrewonthedimmermarked"YL/RD"ortheYellow/Red
dimmer lead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked
"WH".
WIRING MATCHING REMOTE (3-Way wall box with Line
Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)when
removingoldswitchandFirstTravelerdimmerterminalscrew
marked"BK"ortheBlackdimmerlead.
• SecondTravelerwallboxwirefromdimmertoremoteterminal
screwmarked"YL/RD"(note wire color as above).Thistraveler
fromtheremotemustgototheterminalscrewonthedimmer
marked"YL/RD"ortheYellow/Reddimmerlead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked
"WH".
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchase
date,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredin
anymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtove
years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
NOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhen
mountingdevice.
• Restorepoweratcircuitbreakerorfuse.
• Seeapplicableoperationsectiontoensuredimmerorswitchisfunctioningproperly.
If lights do not turn ON, refer to the TROUBLESHOOTING section.•
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
CoveredbyoneormoreUS&ForeignPatentsandpatentspending
Copyright
©
2007LevitonManufacturingCo.,Inc.
AllRightsIncludingTradeDressRightsReserved
Eco-10™(EcoSeries)isatrademarkandHi-lume
®
isaregisteredtrademarkof
LutronElectronicsInc.
PK-93461-10-00-2A
Restore Power:
Restorepoweratcircuitbreakerorfuse.Installation is complete.
Step 8
Dimmer Remote Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 7
Installationmaynowbecompletedbytightening
mountingscrewsintowallbox.Attachwallplate.
VP00R Dimmer Remote Operation (Device may be unlighted):
NOTE:ThelightswillturnONatbrightnesssetondimmer’sDIM/BRIGHTbar.The
lightingcanbeswitchedfromeitherthedimmerortheremotelocation.
OPERATION
CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.
• Lights Flickering
 -Lamphasabadconnection.
 -Wiresnotsecuredrmlyunderterminalscrewsofdimmerand/orremote.
• Light does not turn ON and Locator LED does not turn ON
 -Circuitbreakerorfusehastripped.
 -Lampisburnedout.
- Lamp Neutral connection is not wired.
• Intermittent dimmer operation
 -Minimumloadisunder40W.
• Remote does not operate lights
 -Ensurethattotalwirelengthdoesnotexceed300ft(90m).
 -EnsurethatonlyCoordinatingRemotesareusedwithViziarf+™devices
TROUBLESHOOTING
WIRING DIMMER (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmer
lead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchtodimmerterminal
screwmarked"RD"ortheReddimmerlead.
• FirstTravelerLineHottodimmerterminalscrewmarked"BK"ortheBlackdimmer
lead.
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"ortheYellow/
Red dimmer lead.
• SecondTravelerwallboxwire(note color as above) to dimmer terminal screw
marked"YL/RD"ortheYellow/Reddimmerlead.Thistravelerfromthedimmer
mustgototheterminalscrewontheremotemarked"YL/RD".
• Proceed to Step 6.
Step 5a cont’d
4-Way Wiring with Matching Remote (w/LEDs)
Application:
BK
RD
YL/RD
3
T e rminal
Screw marked
Red (RD)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Coordinating Remote
(3-Way Wall box from Step 2)
Coordinating Remote
(4-Way Box from Step 2)
Dimmer
(3-Way Wall Box from Step 2)
6
2
1
5
4
BK
RD
YL/RD
T e rminal
Screw marked
Black (BK)
T e r m in a l
Scr e w m a r ke d
Red ( RD )
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
2
4
3
5
1
BK
RD
YL/RD
2
4
3
5
1
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote
(no LEDs)
Coordinating Remote
(no LEDs)
YL/RD
YL/RD
YL/RD
RD
RD
WHWH
RD
BK
BK
BK
Black
not used
White
Line
120VAC, 60Hz
not used
not used
Green
Ground
Green
Ground
Green
Ground
Step 5b
4-Way Wiring with Coordinating Remote (no LEDs)
Application:
NOTE:IncandescentandMagneticLowVoltageinstallationsonly.
NOTE: Screw terminal dimmer depicted.
WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• FirstTravelerandThirdTravelerwallboxwire(note wire colors) to terminal
screwmarked"RD".Thesetravelersfromtheremoteinthe4-wayboxmustgoto
theterminalscrewonthedimmermarked"RD"orReddimmerlead,andtothe
terminalscrewmarked"RD"oftheremainingremoteinthe3-waybox.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwire(note wire
colors)toterminalscrewmarked"YL/RD".Thesetravelersfromtheremotein
the4-wayboxmustgototheterminalscrewonthedimmermarked"YL/RD"or
theYellow/Reddimmerlead,andtotheterminalscrewmarked"YL/RD"ofthe
remainingremoteinthe3-waybox.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelafxed.
NOTE:Ifinsulatinglabelisnotafxedtoterminalscrewmarked"WH",use
electricaltapetocover.Remoteterminalscrewmarked"BK"isnotused.Use
electricaltapetocover.
WIRING DIMMER (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmercanbe
installedoneithertheLineorLoadsideofthe3-waycircuit.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed
300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmer
lead.
• LineHot(common)wallboxwireidentied(tagged)whenremovingoldswitchto
dimmerterminalscrewmarked"BK"orBlackdimmerlead.
• FirstTravelerwallboxwiretodimmerterminalscrewmarked"RD"orReddimmer
lead (note wire color as above).Thistravelerfromthedimmermustgotothe
terminalscrewontheremotemarked"RD".
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red
dimmer lead.
• SecondTravelerwallboxwiretodimmerterminalscrewmarked"YL/RD"orYellow/
Red dimmer lead (note wire color as above).Thistravelerfromthedimmermust
gototheterminalscrewontheremotemarked"YL/RD".
WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoterminalscrew
marked"BK".
• FirstTravelerwallboxwire(note color as above)toterminalscrewmarked"RD".
Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked
"RD"ortheReddimmerlead.
• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked
"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewonthe
dimmermarked"YL/RD"ortheYellow/Reddimmerlead.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelafxed.
NOTE:Ifinsulatinglabelisnotafxedtoterminalscrewmarked"WH",use
electricaltapetocover.
• Proceed to Step 6.
4
3
5
Black
Green
White
Red
Yellow/Red
1
2
Control
(3-Way Wall Box from Step 2)
BK
RD
YL/RD
Matching Remote
(3-Way Wall box from Step 2)
Matching Remote
(4-Way Wall box from Step 2)
4
3
5
Additional
Neutral Wire
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
White (WH)
6
2
1
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Control
Matching Remote
(w/LEDs)
Matching Remote
(w/LEDs)
YL/RD
YL/RD
Yellow/Red
Red
WH
White
WH
BK
BK
Black
Line
120VAC, 60Hz
Black
White
Load
Green
Ground
Green
Ground
Green
Ground
4-Way Wiring with Matching Remote (w/LEDs) for Controls
with Neutral Connection Application:
NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronic
Switch installations only.
NOTE: Dimmer is depicted.
Step 5c
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoadconnection.The
matchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutral
connection.ANeutralwiretothematchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed
300ft(90m).
WIRING MATCHING REMOTE (4-Way wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• FirstTravelerandThirdTravelerwallboxwiretoremoteterminalscrewmarked"BK"
in4-waybox,andtoterminalscrewmarked"BK"oftheremainingremotein3-way
box.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwirefromcontrolin
3-wayboxtoremoteterminalscrewmarked"YL/RD"in4-wayboxandtoterminal
screwmarked"YL/RD"oftheremainingremotein3-waybox(note wire colors).This
travelerfromtheremotesmustgototheterminalscrewmarked"YL/RD"or
Yellow/Redcontrollead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING MATCHING REMOTE (3-Way wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremovingoldswitchand
FirstTravelerwallboxwiretocontrolterminalscrewmarked"BK"orBlackdimmer
lead.
• SecondTravelerwallboxwirefromcontroltoremoteterminalscrewmarked"YL/RD"
(note wire color as above).Thistravelerfromtheremotemustgototheterminal
screwmarked"YL/RD"orYellow/Reddimmerlead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING CONTROL (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmerlead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoterminalscrew
marked"RD"orRedcontrollead.
• FirstTravelerLineHottoterminalscrewmarked"BK"orBlackcontrollead.
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red
control lead.
• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked
"YL/RD"orYellow/Redcontrollead.Thistravelerfromthecontrolmustgotothe
terminalscrewontheremotemarked"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrollead.
• Proceed to Step 6.
4-Way Wiring with Coordinating Remote (no LEDs) for Controls
with Neutral Connection Application:
NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedand
Electronic Switch installations only. NOTE: Dimmer is depicted.
Step 5d
WIRING CONTROL (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHotconnection.
NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed300ft
(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreencontrollead.
• LineHot(common)wallboxwireidentied(tagged)whenremovingoldswitchto
terminalscrewmarked"BK"orBlackcontrollead.
• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRedcontrollead(note
wire color as above).
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red
control lead.
• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"orYellow/Red
control lead (note wire color as above).Thistravelerfromthecontrolmustgotothe
terminalscrewontheremotemarked"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrollead.
WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenboth
screws.
NOTE:Maximumwirelengthfromcontroltolastremoteis300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoFirstTraveler(note
color as above).
• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked
"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"
orYellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".
• Proceed to Step 6.
BK
RD
YL/RD
3
5
1
2
3
4
5
Black
White
Green
Red
Yellow/Red
2
1
1
4
4
3
5
2
T e rminal
Screw marked
White (WH)
T e rminal
Screw marked
White (WH)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
T e rminal
Screw marked
Black (BK)
Coordinating Remote
(3-Way Wall box from Step 2)
Coordinating Remote
(4-Way Box from Step 2)
Control
(3-Way Wall Box from Step 2)
6
BK
RD
YL/RD
Hot (Black)
Neutral (White)
Control
Coordinating Remote
(no LEDs)
Coordinating Remote
(no LEDs)
YL/RD
YL/RD
YL/RD
RD
White
Red
Black
Black
BKWH
WH
White
Line
120VAC, 60Hz
RD
not used
not used
not used
not used
BK
Load
Green
Ground
Green
Ground
Green
Ground
WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenboth
screws.
NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• ConnectFirstTravelerwallboxwiretoThirdTravelerwallboxwire(note wire colors)
toterminalscrewmarked"RD"ofremotein4-waybox,andtoterminalscrewmarked
"RD"oftheremainingremotein3-waybox.
• ConnectSecondTravelerandFourthTravelerwallboxwire(note wire colors) to
terminalscrewmarked"YL/RD"ofremotein4-waybox,andtoterminalscrewmarked
"YL/RD"oftheremainingremotein3-waybox.
 Thistravelerfromtheremotesmustgototheterminalscrewmarked"YL/RD"or
Yellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".
Step 5d cont’d
Testing your Remote prior to completely
mounting in wall box:
Step 6
Push Pad (Default settings)
Turn ON from OFF position:
Tap–LightsturnONtopresetlevel.
PressandHold–LightsturnONtofullbright.
Turn OFF from ON position:
Tap–LightsturnOFF.
DIM/BRIGHT Bar
BRIGHTEN:
PressrighthalfofDIM/BRIGHTBar–Lightsbrightento
desiredlevel.
DIM:
PresslefthalfofDIM/BRIGHTBar–Lightsdimto
desiredlevel.
Ifyoucontinuetohold,thelightswillDIMtominimum
levelandthenturnOFF.
Intheeventofpoweroutageorinterruptionthelightswill
resettothelastlevelwhenpowerisrestored.
DIM/BRIGHT
Bar
Push Pad
Locator
Light
LED
Brightness
Display
VP0SR Switch Remote Operation (Device may be unlighted):
Thelightingcanbeswitchedfromeitherthedimmerortheremotelocation.
Push Pad (Default settings)
Turn ON from OFF position:
Tap–LightsturnONtopresetlevel.
Turn OFF from ON position:
Tap–LightsturnOFF.
Intheeventofpoweroutageor
interruption the lights will reset to the last
levelwhenpowerisrestored.
Push Pad
Locator
Light
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
DigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedto
providereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.
Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructions,maycauseharmfulinterference
toradiocommunications.However,thereisnoguaranteethatinterferencewillnot
occurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferenceto
radioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFF
andON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC COMPLIANCE STATEMENT
• Positionallwirestoprovideroomin
outletwallboxfordevice.
• Ensurethattheword"TOP"isfacingup
onthedevicestrap.
• Partiallyscrewinmountingscrewsin
wallboxmountinghole.
VP00R-1L ADVANCED PROGRAMMING FEATURES
FOR USE WITH VIZIA RF +™ ONLY
Definition of A Modes
A) LEDOptions:SetssingleLED(default)orLEDBartodisplaytheloadstatus.
Program Mode A
To enter Program Mode A:
Press and hold the Push Pad and then the righthalfoftheDIM/BRIGHTBar
(
^
)
for5
secondsuntilallLEDsblink.
UponreleasingthePushPadLocatorLEDwillblinkoncepersecondtoindicate
Program Mode A, LED Options.TochangetheLED Options settings, release
thePushPad.Thissettingwillautomaticallybesavedandthedevicewillexit
Programming Mode.
LED Options
LED Brightness/Fan Speed Display
Default Single LED
Firsttoggle LEDBar
/