Danfoss Settings AKA 245 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Danfoss Settings AKA 245 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Funktion: Gatewayen sender information - fra følgende regulatorer ......................................................................................................................
- til ..................................................................................................................................................................
Der er tilsluttet printer (ja/nej): ______ BUS terminering er åben (ja/nej): _____
Function: The gateway sends information - from the following controller ..........................................................................................................
- to ................................................................................................................................................................
Printer connection (yes/no): _____ BUS termination is open (yes/no): _____
Funktion: Gateway sendet Information - von folgenden Reglern ............................................................................................................................
- an .....................................................................................................................................................................
Drucker ist angeschlossen (ja/nein): ______ BUS Drahtverbindungen sind off en (ja/nein): _____
Fonction: envoie ses informations - en provenance des suivants .............................................................................................................................
- vers .............................................................................................................................................................................
Imprimante installée (oui/non): ______ Bouclage BUS ouvert (oui/non): _____
Función: El interface (gateway) envia información - desde los siguintes controles .....................................................................................
- a ............................................................................................................................................
Impresore instalada (Si/No): ______ Terminación BUS abierto (Si/No:) ______
SETTINGS
AKA 245
RI8JM153 08-2004
Indstillet af: Firma / Person / Dato
Set by: Firm / Person / Date
Eingestelt von: Firma / Person / Datum
Réglé par: Firm / Personne / Date
Ajustado por: Compañia / Persona / Fecha
------------------------------/---------------------------/---------------
AKA 245 indstillinger
AKA 245 Einstellungen
Réglages AKA 245
Ajustes AKA 245
Systemadresse
System address
Adresse système
Sistema dirección
Network : Address = ______:______
Software version 6.0x
Software Version 6.0x
Logiciel version 6.0x
Versión de software 6.0x
Time setting
Year Month Date Hour Minute Summer time
Manual Auto
OFF OFF
ON ON
Start Stop
Month: Month:
Date: Date:
Hour: Hour:
Confi guration
Code No.084B2268 Normal limit Extended limit Extended code Service code
Prog.ver 6.xx x= [1] [2] [40] [99]
Dansett time Dansett logoff Password on/off
[60] [2] Delete password
Network : Address _ _ _ _ _ _:_ _ _ _ _ _
Side 2
Page 2
Seite 2
Página 2
RC-ET
2 Settings RI8JM153 © Danfoss 08/2004 AKA 245
Address & GWtype
Network address Change GWtype Boot gateway
↓↓-
Network: Address: PC Modem MSS
0 2 : ___
Communication setup - Router
Edit line
Lower limit Upper limit Port No.
Address / Phone No./IP Address
0-123, 125 / Phone No.Network Network 1= DANBUSS
2= PC-/Modem/MSS Default = 0
Communication setup - RS 232 Port / - RS 232 Port
PC Modem and MSS
RS 232 Port speed Boot gateway Life time RS 232 port speed Boot gateway
Baud rate (9600) sec. Baud rate 9600
Boot gateway -
Communication setup - LON Port
LON Adr. range - - - Boot gateway
-
LON Adr. Low LON Adr. High
/