Comnet CNGE2MC Series User manual

Category
Network media converters
Type
User manual

The Comnet CNGE2MC Series is a high-performance media converter that enables the extension of Ethernet networks over fiber optic cabling. It supports data rates up to 1000 Mbps and is compatible with both multimode and single-mode fiber. The CNGE2MC Series features two RJ-45 ports for copper connections and two SFP slots for fiber connections. It also includes a variety of diagnostic LEDs for easy troubleshooting and monitoring.

The Comnet CNGE2MC Series is a high-performance media converter that enables the extension of Ethernet networks over fiber optic cabling. It supports data rates up to 1000 Mbps and is compatible with both multimode and single-mode fiber. The CNGE2MC Series features two RJ-45 ports for copper connections and two SFP slots for fiber connections. It also includes a variety of diagnostic LEDs for easy troubleshooting and monitoring.

Mechanical Installation Instructions
Figure 1: Dimensions are for a standard ComNet
one slot module.
Rack Module:
The unit is designed to be installed in the ComNet 19-inch (483-mm) EIA standard card-cage rack, the C1-US,
C1-EU,
or the C1-CH. Follow these guidelines to install rack cards after performing module setup procedures.
C1-US,
C1-EU, or the C1-CH Card Cage Racks
CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack,
ComNet recommends that the power supply be turned off and that the rack power supply is disconnected
from any power source. Not
e: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the
edge connector at the back of the card seats in the corresponding slot in the racks connector panel.
Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated
against the fr
ont of the rack.
CNGE2MC
Installation Considerations
This fiber-optic link is supplied as
a S
tandalone/Rack module.
Units should be installed in dry
locations protected from extremes
of temperature and humidity.
Standalone Module:
The unit is provided with a mounting
pla
te with holes for two No. 6 pan
head screws (3-mm or 3.55-mm).
The type of screws must be suitable
f
or the surface where a module will
be mounted. See figure 1.
1. Determine where the module will be
installed, and ensure that there is
adequate spac
e at both ends for
making the various cable
connections and for reading the
diagnostic LEDs.
2. Attach the module to a flat surface
using two mounting screws.
(Not Supplied)
.156 [3.96 mm]
.313 [7.95 mm]
INS_CNGE2MC_REVA
04/07/09
Page 1
Communication Networks
3 Corporate Drive • Danbury, CT 06810 • USA
Tel: 203-796-5300 • Toll Free: 1-888-678-9427
www.comnet.net
CNGE2MC
10/100/1000 Mbps ETHERNET 2 PORT
MEDIA CONVERTER
GREEN
YELLOW
BLACK WITH WHITE STRIPE
BLACK
INS_CNGE2MC_REVA
04/07/09
Page 2
INSTALLATION INSTRUCTIONS
GREEN = Powered On
LINK A: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
RJ45
RJ45: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
Off = No Link
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should be installed in a restricted access location; available through the use of a lock and key or other
means of secur
ity. Access should be limited to service personnel who have been instructed about the reasons for the restrictions
to the location. Any and all precautions should be taken and controlled by the authority responsible for the location.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly,
the op
erating ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installa
tion of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
CNGE22MC
DUAL 10/100/1000 Mbps MEDIA CONVERTER
GREEN
YELLOW
BLACK WITH WHITE STRIPE
BLACK
INS_CNGE22MC_REVA
05/07/09
Page 2
INSTALLATION INSTRUCTIONS
GREEN
YELLOW
GREEN = Powered On
RJ45: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
Off = No Link
LINK A/B: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
RJ45
RJ45
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should be installed in a restricted access location; available through the use of a lock and key or other
means of secur
ity. Access should be limited to service personnel who have been instructed about the reasons for the restrictions
to the location. Any and all precautions should be taken and controlled by the authority responsible for the location.
IMPORTANT SAFEGUARDS:
A) Elevated Op
erating Ambient - If installed in a closed or multi-unit rack assembly,
the opera
ting ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installa
tion of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
CNGE2MC-M
GIGABIT MEDIA CONVERTER
GREEN
YELLOW
RJ45
GREEN = Power On
LINK GREEN:
Solid = No Activity
Blinking = Activity
Off = No Link
BLACK WITH WHITE STRIPE
BLACK
INS_CNGE2MC-M_REVA
04/07/09
Page 1
INSTALLATION INSTRUCTIONS
Communication Networks
3 Corporate Drive • Danbury, CT 06810 • USA
Tel: 203-796-5300 • Toll Free: 1-888-678-9427
www.comnet.net
RJ45: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
Off = No Link
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should be installed in a restricted acc
ess location; available through the use of a lock and key or other
means of security. Access should be limited to service personnel who have been instructed about the reasons for the restrictions
to the location. Any and all precautions should be taken and controlled by the authority responsible for the location.
INS_CNGE2MC-M_REVA
04/07/09
Page 2
SFP-(x) Installation/Removal
Installation:
Removal:
CAUTION:
- The Fiber Optic sub-module is static sensitive. Use static handling precautions when installing or removing the sub-module.
- Protect your SFP sub-modules by inserting clean dust plugs into the SFP sub-modules after the optical fiber is extracted from
them. Be sure to clean the optic surfaces of the optical fiber before you plug them back into the optical bores of another SFP
sub-module. Avoid getting dust and other contaminants into the optical bores of your SFP sub-modules.The optics will not
work correctly when obstructed by dust.
SFP Module:
- The SFP sub-module installs in the connector cage located on
the unit corresponding to the port assignment to be used.
- The SFP sub-module is keyed and can only be installed
in one orientation.
- The SFP sub-module (see Figure 1) has a bale clasp that you
use t
o secure the SFP sub-module in a connector cage.
The photos used in the following sequence are intended to aid
in the installation and removal of the SFP sub-module and may
not match your particular model.
To insert an SFP sub-module into a connector cage,
perform the following steps:
Step 1 - F
lip the bale clasp up before inserting the
SFP module.
Step 2 - Line up the SFP sub-module with the
p
ort and slide it into the port.
(see Figure 2)
Step 3 - When you are ready to attach the optical
fiber, remove the rubber plugs from the
sub-module and save for future use.
Note: When installed properly the SFP
sub-module will lock in place.
To remov
e an SFP sub-module from a connector
cage, perform the following steps:
Step 1 - Disconnect the optical fiber from the SFP
sub-module.
Step 2 - Open the bale clasp on the SFP
sub-module by pressing it down with
your index finger as shown in Figure 3.
Step 3 - Grasp the SFP sub-module between your
thumb and index finger and carefully
remove it from the connector cage as
shown in Figure 4.
Step 4 - Install the rubber plugs back into the SFP
sub-module optical bores, and place the
SFP sub-module in anti-static protective
packaging.
e
e
e
Figure 1
Figure 2
Figure 3
Figure 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Comnet CNGE2MC Series User manual

Category
Network media converters
Type
User manual

The Comnet CNGE2MC Series is a high-performance media converter that enables the extension of Ethernet networks over fiber optic cabling. It supports data rates up to 1000 Mbps and is compatible with both multimode and single-mode fiber. The CNGE2MC Series features two RJ-45 ports for copper connections and two SFP slots for fiber connections. It also includes a variety of diagnostic LEDs for easy troubleshooting and monitoring.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI