Emerson FIELDVUEDVC6200 Quick start guide

Type
Quick start guide
Success in today’s competitive environment
requires safe and reliable equipment
performance. FIELDVUE
Performance
Diagnostics can detect issues and provide
recommendations for correcting conditions
that could lead to unplanned shutdowns.
Valves are notorious for friction and dead band
problems that add variability and cost you
money. Performance Diagnostics will help unveil
conditions so you can maximize throughput and
make sound predictive maintenance decisions.
Easy Diagnostics, No Roadblocks
“I can’t shut down my process to run valve
diagnostics!” Using FIELDVUE instruments,
you can diagnose, analyze, and trend valve
diagnostic data while the valves are in service.
You are given a real-time, accurate picture of
valve health, not just numbers and graphs, all
without impacting your process.
“I can’t sit at my computer all day watching the
valves!” The Triggered Profile diagnostic watches
your valves, even when you’re not. Schedule it to
collect data automatically or when triggered by
a certain event. ValveLink
software is equipped
with an Event Messenger feature that can alert
you when a trigger condition is detected.
“Even if I can get the diagnostic information, I don’t
know what the curves mean!” Know the condition
of your valve at a glance by checking the “green,
yellow, red light” feature in ValveLink software.
Green, yellow, and red light symbols designate
the level of importance. Recommended actions
are also provided.
n Green light - OK
n Yellow light - Needs maintenance soon
n Red light - Maintenance required
ValveLink software includes:
n ValveLink Solo
n AMS ValveLink SNAP-ON
n ValveLink Mobile
n ValveLink DTM
n ValveLink PLUG-IN for PRM
®
Emerson FIELDVUE
Performance Diagnostics
Diagnose Your Control Valves In-Service
Detect actuator tubing, diaphragm, and piston seal leaks with the
Performance Diagnostics Air Mass Flow Test. The yellow light indicates
a leak that needs attention, for instance.
Unmatched FIELDVUE Diagnostics
FIELDVUE Performance Diagnostics include:
n PD One Button
n Valve Friction
n On-line valve and device alerts
n On-line trending of critical valves
n Partial Stroke for Safety Instrumented
System (SIS) Solutions
These diagnostics can be scheduled as the
system allows or anytime with the 475 field
communicator.
Get FIELDVUE Diagnostics
To use Performance Diagnostics on any valve you
need two things: (1) a FIELDVUE instrument with
Performance Diagnostics level and (2) ValveLink
software.
You may purchase new FIELDVUE digital valve
controllers with Performance Diagnostics
or upgrade existing instruments to include
Performance Diagnostics. Your local Emerson sales
contact can provide a simple Instrument StepUp.
In most cases, there are no hardware changes to
the instrument and the upgrade can be done
on-line while the process is running.
Contact your local Emerson sales office for a
Performance Diagnostics demonstration. Their
highly skilled and experienced applications
personnel are ready to help you take advantage
of the many benefits of FIELDVUE Performance
Diagnostics.
© 2011, 2015 Fisher Controls International LLC. All Rights Reserved.
Fisher, FIELDVUE, ValveLink, SNAP-ON, and PlantWeb are marks owned by one of the companies in the Emerson Process Management
business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of
Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their
accuracy, nothing herein is to be construed as a warranty or guarantee, express or implied, regarding the products or services described
herein or their use, performance, merchantability or fitness for a particular purpose. Individual results may vary. All sales are governed by
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of our
products at any time without notice. Responsibility for proper selection, use and maintenance of any product or service remains solely with
the purchaser and end user.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore, 128461 Singapore
www.Fisher.com
D351048X012 / MBB11 / Mar15
On-line Performance Diagnostics tests can detect more than 200
fault conditions and provide recommended actions while the control
valve remains in service. Here are a few examples where Performance
Diagnostics can detect problems before they adversely impact
your process:
Detected Problem Performance Diagnostics Test
Valve blockage or binding Valve friction calculated and trended on-line
Broken or loose linkages Deadband calculated and trended on-line
Dirty instrument air I/P and relay integrity test
Actuator and tubing leaks Air mass flow test
Poor calibration Travel deviation
Insufficient air supply Supply pressure test
Instrument elastomer wears out I/P and relay integrity test
Valve stuck Partial stroke test
>>
One Button Sweep
In one keystroke, you
can instruct ValveLink
software to run several
Performance Diagnostics
tests. As the test is
running, the software will
show problems, possible
causes, and recommended
actions.
The software will
document
Performance Diagnostics
test results in a
preformatted Microsoft
®
Word report.
As a core component in the
PlantWeb
digital plant
architecture, Fisher valves
and FIELDVUE digital valve
controllers give you the power
to deliver flow control accuracy
of less than 0.25%!
  • Page 1 1