Kohler K-T14421-4-SN Installation guide

Category
Sanitary ware
Type
Installation guide
Installation Guide
Single-Control Bath and Shower Trim
K-14418, K-T14420, K-T14421,
K-T14422, K-T14423, K-14425,
K-14426, K-14427
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page “Français-1”
Español, página “Español-1”
1031692-2-D
IMPORTANT INSTRUCTIONS
READ AND SAVE FOR THE
CONSUMER
WARNING: Risk of scalding or other severe injury.
Before completing installation, the installer must set the
maximum water temperature setting of this valve to minimize the
risks associated with scalding hazards according to ASTM F 444.
Do not install a shut-off device on either outlet of this valve. The
installation of any such device may create a cross-flow condition
at the valve and affect the water temperature.
Factors that change the temperature of the water supplied to the
valve, such as seasonal water temperature changes, and water
heater replacement or servicing, will change the maximum water
temperature supplied by the valve and may create a scalding
hazard.
The pressure-balanced valve will not compensate for changes in
the water supply temperature; adjust the maximum water
temperature setting of this pressure-balanced valve when such
changes occur.
Pressure-balanced valves may not provide protection against
scalding if there is a failure of other temperature-limiting devices
elsewhere in the plumbing system.
The installer is responsible for installing the valve and adjusting the
maximum water temperature of this valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature
adjustment instructions in this document, in the United States please
contact our Customer Service Department at 1-800-4-KOHLER.
Outside the U.S., please contact your distributor.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in
the information box in the Homeowners Guide and on the valve label.
Retain the Homeowners Guide for future reference.
1031692-2-D 2 Kohler Co.
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few
minutes to review this manual before you start installation. If you
encounter any installation or performance problems, please don’t
hesitate to contact us. Our phone numbers and website are listed on
the back cover. Thanks again for choosing Kohler Company.
Tools and Materials
Before You Begin
CAUTION: Risk of product damage to the K-306-KS valve
assembly. When using this valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
Observe all local plumbing and building codes.
The finished wall or bath/shower unit must be installed prior to
installing this trim.
Before installing the trim, determine if the maximum water
temperature is acceptable to the user. If temperature adjustment is
needed, refer to the Optional Temperature Limiting Adjustment
section of this guide.
The valve shuts off by water pressure. Do not force the handle in
any direction. To turn the valve off, gently turn it to the OFF
position.
Shut off the main water supply.
Kohler Co. reserves the right to make revisions in the design of
products without notice, as specified in the Price Book.
Plumbers
Putty
Strap
Wrench
Thread
Sealant
Kohler Co. 3 1031692-2-D
1. Install the Spout
Remove the temporary nipple.
Apply thread sealant and install a 1/2 nipple so it extends
1-1/4 (3.2 cm) beyond the finished wall.
Apply thread sealant to the nipple and thread the spout onto the
nipple.
Carefully tighten with a clean strap wrench.
1/2" Nipple
1-1/4"
(3.2 cm)
1031692-2-D 4 Kohler Co.
2. Install the Showerhead
CAUTION: Risk of product damage. To avoid clogging the
showerhead spray outlets, use thread sealant tape on the
shower arm threads. Do not use thread sealant compound
(pipe dope).
Remove the temporary nipple from the shower elbow.
Apply thread sealant to the shower elbow, then install a 1/2
NPT pipe nipple to the shower elbow. The nipple must extend
1-1/4 (3.2 cm) beyond the finished wall.
Turn the main water supply on.
Run hot and cold water through the shower arm to flush out dirt
and debris.
IMPORTANT! If a gasket is NOT installed on the escutcheon of
the shower arm: Apply a bead of plumbers putty or other sealant to
the back of the shower arm. Refer to the putty or sealant
manufacturer’s instructions for proper application. This will ensure a
watertight seal.
Apply thread sealant tape to the pipe nipple and thread the
shower arm onto the pipe nipple.
Carefully tighten the shower arm to the pipe nipple with a clean
strap wrench.
Remove all excess putty around the escutcheon.
1-1/4"
(3.2 cm)
1/2"
Nipple
Kohler Co. 5 1031692-2-D
3. Optional Temperature Limiting Adjustment
CAUTION: Risk of personal injury. The water temperature
should never be set above 120°F (49°C).
Turn the valve clockwise to the full open position and let the hot
water run for several minutes. Position a thermometer in the
water stream and check the temperature.
For minor water temperature changes, adjust the setscrew, and
recheck the water temperature.
For major water temperature changes, remove the O-ring and
collar from the valve stem. Slowly rotate the valve stem until the
desired maximum water temperature is reached.
Reinstall the collar on the valve stem with the setscrew against
the side of the tab.
Reinstall the O-ring, rotate the valve stem counterclockwise to
shut the water off.
Recheck the water temperature.
Complete the information on the valve label (if supplied).
O-Ring
Setscrew
Tab
Tab
Collar
Collar
Setscrew
Valve
Label
Standard
Valve
High Flow
Valve
Valve
Stem
1031692-2-D 6 Kohler Co.
4. Diverter Assembly
Remove and discard the plaster guard and/or dome, if installed.
Position the actuator over the diverter stem. Tighten the setscrew.
Slide the guide over the actuator and thread it onto the diverter
stem.
Guide
Setscrew
Actuator
Diverter Assembly
Valve
Stem
Diverter
Stem
Discard plaster
guard with dome.
Kohler Co. 7 1031692-2-D
5. Install the Faceplate and Handle
CAUTION: Risk of product damage to the K-306-KS valve
assembly. When using this valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
For installation over a tiled wall, apply a bead of silicone sealant
around the back edges of the faceplate.
Break off the tab at the lower right on the backing plate. Fit the
backing plate over the valve so the large hole is on the bottom
and secure with two screws. Do not overtighten.
Rotate the valve stem fully counterclockwise.
Position the faceplate over the backing plate and thread the collar
into the backing plate. Do not cross thread.
Insert the sleeve into the notches of the collar and hand tighten. If
the collar does not thread into the backing plate, thread the
backing plate screws 1/2 turn back.
Insert the stem extension through the sleeve and collar with the
flat sections of the stem extension facing up.
Attach the stem extension to the valve stem with the flat head
screw.
Insert the handle screw through the handle stem.
Place the handle over the handle stem.
Securely tighten the handle screw to the handle.
Attach the handle stem with the attached handle to the stem
extension.
Screws
Setscrew
Handles
Handle Stem
Notch
Sleeve
Stem
Stem Extension
Tab
Handle Screw
Faceplate
Collar
Valve Stem
Flat Head
Screw
Backing
Plate
1031692-2-D 8 Kohler Co.
Install the Faceplate and Handle (cont.)
Secure the handle stem to the stem extension with the setscrew.
Check the handle alignment. The handle lever should point
straight down.
To adjust the handle position, remove the handle and reposition
the stem. Reinstall the handle and check the alignment. Repeat
until the proper alignment is achieved.
For further adjustment, remove the handle screw and rotate the
handle in the stem extension. Reinstall the handle screw.
6. Complete the Installation
Turn the valve fully counterclockwise to the off position.
Remove the aerator assembly from the spout by turning it
counterclockwise.
Turn on the main water supply.
Turn the valve to the center and run water for approximately one
minute to flush the system.
Check all connections for leaks.
Reinstall the aerator.
Kohler Co. 9 1031692-2-D
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Kohler K-T14421-4-SN Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI