  • Hello! I am an AI chatbot trained to assist you with the Genesis Renew Installation and Use Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
GENESIS|RENEW™
AUTOMATICWATERCHANGESYSTEM
INSTALLATIONANDUSE

CongratulationsonyourpurchaseoftheGENESIS|RENEW™AutomaticWaterChangeSystem!Pleasetakeafewmomentstoread
andfollowtheseinstallationinstructionssoyoucanfullyenjoyyournewsystemrightoutofthebox.Ifyouhaveanyquestionsat
all, please visit us at www.GenesisReefSystems.com,
or email us at Support@GenesisReefSystems.com.We are always happy to
hearfromourcustomers!
Thefollowingitemshavebeenshippedwithyoursystem:
(1)RENEW™ControlModule
(2)RENEW™MeteringReservoirs(ProSystemsinclude2LevelSensorsineachReservoir)
(2)RENEW™MeteringReservoirCovers
(2)BarbedBallValves
(1)Communicatio n CableforusewiththeGENESISSTORM™AutomaticTopOffSystem
(2)LevelSensorVerticalMembers(AdvancedandProSystemsonly)
(4)Level
SensorShrouds(AdvancedandProSystemsonly)
(2)StandaloneLevelSensors(AdvancedandProSystemsonly)
(4)5’Lengthsof1/2"Tubing(ProSystemonly)
(2)5’Lengthsof5/8”Tubing(ProSystemonly)
(4)SuctionCups(AdvancedandProSystemsonly)
(6)MountingScrews
(2)Pumps(Optional)
Installation
1. Findsuitablemountinglocations
TheMeteringReservoirsmustbelocatedabovethehighestwaterlevelinthesump(oraquariumifyoudon’t
useasump)andthereplacementwaterbin,ataheightwheretheselectedpumpswillbeabletosupplyat
least1gallonofwater
perminute.TheMeteringReservoirsrarelyneedtobeaccessedafterinstallation,so
feelfreetotuckthemawaysomewherethatkeepsyourdaytodayaquariumworkspaceclear.
Rememberwaterisheavy!TheMeteringReservoirsmustbesecurelymountedonaverticalsurfacethat
cansupporta
minimumof20poundsperbin.WhenmountingtheMeteringReservoirsonawall,ensurethat
themountingscrewswillbedrivenintowallstudsorusewallanchorsthatwillsupporttheweightofthebins.
TheControlModulemustbelocatedinaneasilyaccessible,drylocationprotected
fromaccidentalsplashes.
Thecordsandcontrolcablessuppliedareapproximately6feetinlength,andlevelsensorcablesare
approximately8feetinlength.EnsurethattheywillreachfromtheControlModuletotheirrespective
locationsbeforepermanentlymountingthecomponents.
2. MounttheMeteringReservoirs
Ensurenoelectricalwiresorplumbingresidebehindorwithinthemountingarea.Beverycarefulwhen
drillingordrivingscrewsintoablindmountinglocation!
Usingthesuppliedtemplateasaguide,markanddrilltwopilotholesasindicated.Notethatalinedrawn
betweenthecenterpoints
ofthetwoholesmustbeperfectlyvertical.
Insertwallanchorsifnecessary,followingalldirectionsprovidedwiththeanchors.
Drivethemountingscrewsintotheholesoranchors,leavingabout1/8”inchbetweenthescrewheadandthe
mountingsurface.
SliptheMeteringReservoirsontothescrews
andgentlypulldownabout1/2"untilfullyseated.Thereshould
beno“play”betweentheReservoirsandthemountingsurfacewhenproperlysecured.
o Tip:itisoftenconvenienttoinstalltubing,ballvalves,andReservoirCoverspriortomounting
theMeteringReservoirsonthescrews
Repeatthese
stepsforthesecondMeteringReservoir
3. MounttheControlModule
Ensurenoelectricalwiresorplumbingresidebehindorwithinthemountingarea.Beverycarefulwhen
drillingordrivingscrewsintoablindmountinglocation!
Usingthesuppliedtemplateasaguide,markanddrilltwo
pilotholesasindicated.
Insertwallanchorsifnecessary,followingalldirectionsprovidedwiththeanchors.
Drivethemountingscrewsintotheholesoranchors,leavingjustlessthan3/8”inchbetweenthescrewhead
andthemountingsurface.
SliptheControlModuleontothescrewsandgently
pulldownabout1/2"untilfullyseated.Thereshouldbe
no“play”betweentheControlModuleandthemountingsurfacewhenproperlysecured.
4. MounttheLevelSensors(AdvancedandPromodelsorpurchasedseparately)
TheLevelSensorShroudsaredesignedsuchthattheycanbeusedinmany
differentconfigurations.
o LevelSensorscanbeinstalledinside,above,orbelowtheshrouds
o TheShroudCovercanbeinsertedontotherearoftheShroudtocreateahangerthatis
adjustablefortanklipwidthsasnarrowas1/2"oraswideas21/4
o The
shroudscanbeleftopenorcanbeclosedtopreventcrittersorwaterturbulencefrom
affectingthesensors’performance
o Theshroudswillslideontoandsecurethemselvesonanystandard1/2"PVCpipe,allowingthem
tobepositionedatanyheight
o Theshroudscanbehungfromone
anotherusingtheTshapedtabsandslotsonthesides,
allowingmultiplesensorstobepositionedonasingleverticalmemberatslightlydifferent
heights.
o LevelSensorwirescanbedressedthroughtheverticalmemberorPVCpipetogiveacleanlook
toyourinstallation
Using
theLevelSensortopreventapumprundryscenario:
o InstalloneShroudCoverontotherearofoneShroud
o Insertaverticalmemberor1/2"PVCpipethroughtheassembledShroudsuchthattheShroud
Coveractsasaliphanger
o InstalloneLevelSensorinsidea
secondShroudbylooseningtheplasticnutonthesensorand
slidingthesensorintothewidenotchintheShroud
o Inserttheotherendoftheverticalmemberor1/2"PVCpipeintotheShroudwiththesensor
suchthattheLevelSensor’scordwillcomeoutof
theTOPoftheShroudwhenhungonthetank.
o RemoveanypackingfoamortapefromtheLevelSensor
o PlacetheremainingShroudCoverontothelowerShroudtoprotecttheLevelSensorifdesired
o InstallSuctionCupsontothelowerShroudifdesired
o Hangthe
assemblyoverthelipofthetankandadjustthehangerwidth
o AdjusttheheightoftheShroud/Sensortotheminimumdesiredwaterlevel
o SecureSuctionCupstothetankwall
UsingtheLevelSensortopreventanoverflowscenario:
o InstalloneShroudCoverontotherearofoneShroud
o Insertaverticalmemberor1/2"PVCpipethroughtheassembledShroudsuchthattheShroud
Coveractsasalip
hanger
o InstalloneLevelSensorinsideasecondShroudbylooseningtheplasticnutandslidingthe
switchintothewidenotchintheShroud
o Inserttheotherendoftheverticalmemberor1/2"PVCpipeintotheShroudwiththesensor
suchthattheLevelSensor’s
cordwillcomeoutoftheBOTTOMoftheShroudwhenhungonthe
tank.
o RemoveanypackingfoamortapefromtheLevelSensor
o PlacetheremainingShroudCoverontothelowerShroudtoprotecttheLevelSensorifdesired
o InstallSuctionCupsontothelowerShroud
ifdesired
o Hangtheassemblyoverthelipofthetankandadjustthehangerwidth
o AdjusttheheightoftheShroud/Switchtothemaximumdesiredwaterlevel
o SecureSuctionCupstothetankwall
Youcanmixandmatchtheaboveinstallationmethods
tosuityouraquariumsystems’specificneeds
5. ConnecttheComponents
NOTE:ALLWIRESSHOULDHAVEADRIPLOOPTOPREVENTWATERFROMENTERINGTHECONTROLMODULE
PlugintotheControlModuletheharnessfromtheMeteringReservoirthatwillreceivewaterfromyour
aquariumsystem(thewaste
water).Thisharnessplugsintothe6pinreceptacleonthelowerrighthandside
(asyouarelookingatthebackoftheControlModule).
PlugintotheControlModuletheharnessfromtheMeteringReservoirthatwillreceivewaterfromyour
replacementwaterbin.Thisharnessplugsinto
the6pinreceptacleonthelowerlefthandside(asyouare
lookingatthebackoftheControlModule).
Ifused,plugtheaquariumorsump’sLevelSensorcableintothe2pinreceptacleonthelowerrighthandside
(asyouarelookingattheback
oftheControlModule).
Ifused,plugthereplacementwaterbin’sLevelSensorintothe2pinreceptacleonthelowerlefthandside(as
youarelookingatthebackoftheControlModule).
IfcouplingyourRENEW™systemwithaSTORMautomatictopoffsystem(seeour
websiteforwhyyouwant
todothis!),plugthesuppliedcommunicationharnessintothecenter6pinreceptacleonthebackofthe
RENEW™ControlModule,andplugtheotherendintothecenter6pinreceptacleonthebackoftheSTORM
ControlModule.
6. Attach the 1/2”
supply tubing on the replacement water’s Metering Reservoir to a pump and place the pump in the
replacementwaterbin.Cutthetubingtolengthifdesired.
7. Attachthe1/2”su pply tubingonthewastewater ’sMeteringReservoirtoapumpandplacethepumpinthea quariumor
sump.Cutthetubingtolengthifdesired.
8. Routethe5/8”tubingattachedtothereplacementwater’sMeteringReservoirbacktothereplacementwaterbin.The
tubingshouldbesecuredsuchthattheendofthetubingisjustabovethehighestwaterlevelinthebinandso
thatthe
waterwillrundownthesideofthebinasthewaterleveldrops.Doingsowillimprovewaterflowandreducenoisewhen
waterflowsbackintothereplacementwaterbin.Cutthetubingtolengthifnecessary.
9. Route the 5/8” tubing attached to the waste
water’s Metering Reservoir back to the aquarium or sump.The tubing
shouldbesecuredsuchthattheendof thetubingisjustabovethewaterlevelandsothatthe waterwillrundownthe
side.Doing so will improve water flow and reduce noise when water flows back
into the aquariumor sump. Cut the
tubingtolengthifnecessary.
10. Route the 1/2" tubingattached to the valve on the replacement water’sMetering Reservoir to the aquarium orsump.
The end ofthe tubing should be secured such that theend of the tubingis just above
the water level and so that the
waterwillrundowntheside.Doingsowillimprovewaterflowandreducenoisewhenreplacementwaterflowsintothe
aquariumorsump.Cutthetubingtolengthifnecessary.
11. Routethe1/2"tubingattachedtothevalveonthewastewater’sMeteringReservoirtoa suitablereceivingreceptacleor
drain.
IMPORTANT:ALWAYS FOLLOW LOCAL PLUMBINGCODESWHEN CONNECTING TOOR
USING EXISTING PLUMBING. UNLAWFUL OR IMPROPER CONNECTION OR USE CAN
RESULT IN PROPERTY DAMAGE, HEALTH RISKS, AND ENVIRONMENTAL RISKS. IF YOU
ARE UNCOMFORTABLE OR UNQUALIFIED WITH THIS TASK, SEEK THE ADVICE AND
SERVICEOFAQUALIFIED,LICENSEDPLUMBER.GENESISREEFSYSTEMS,LLCCANNOTBE
HELD LIABLE FOR ANY DAMAGES DIRECTLY OR
INDIRECTLY RESULTING FROM
CONNECTIONTO OR USEOF EXISTING PLUMBING.WHENCONNECTING TO OR USING
EXISTINGPLUMBINGYOUAREDOINGSOATYOUROWNRISK.
12. Plugthereplacementwaterpump’spowercordintotheACreceptacleonthebottomrightoftheControl Module(when
viewingthefrontof
theControlModule).Ensurethat adriploopisformedtopreventwaterfromenteringtheControl
Module!
13. Plugthewastewaterpump’spowercordintotheACreceptacleonthebottomleftoftheControlModule(whenviewing
thefrontoftheControlModule).Ensurethatadrip
loopisformedtopreventwaterfromenteringtheControlModule!
14. PlugtheControlModule’spowercordintoaGFCIprotected110VACoutlet.Ensurethatadriploopisformedtoprevent
waterfromenteringtheControlModule!YouarenowreadytouseyourRENEW™AutomaticWaterChanging
System!
GettingtoknowyourRENEW™AutomaticWaterChangeSystem
1. Afterinstallingyoursystem,pluggingitin,andpreparing yourreplacementwater,turnontheRENEW™systembyusing
thepowerswitchonthefrontfaceoftheControlModule.Whenpoweris“ON,”theswitchwillilluminate.SeveralLED
indicatorsandthedisplaywillilluminatewhenthepower
isonaswell.
2. Therearefour userinputbuttonsontheControlModule.Startingontheleftandmovingtowardtheright,thebuttons
areMODE,START/PAUSE/CANCEL,andthenINCREASEandDECREASEontheright.Allarelabeledaccordingly.
3. DepressingtheMODEbuttonchangeswhetherthesystem
willperformawaterchangeoverthecourseofaday,aweek,
oronegallonafteranotheruntilcomplete.Forexample,ifyouwantperforma24gallonwaterchangeoverthecourseof
24hours,usetheINCREASEandDECREASEbuttonsuntilthedisplayreads“24”andthen
presstheMODEbuttonuntilthe
indicatornextto“DAY”isilluminated.WhentheSTARTbuttonisdepressed thesystemwillstartasequenceof24one
gallon water changes, with 1 onegallon water change performed every hour (24 hrs/day divided by 24 gallons).
Changingthemodeto “WEEK” will
stretchthe24 gallon waterchangeoverthetimespan ofoneweekbyperforminga
onegallon water change every 7 hours (168 hrs/week divided by 24 gallons).Finally, changing the mode to
“CONTINUOUS” and pressing the START button would result in a onegallon water change followed immediately by
anotheronegallonwaterchange,foratotalof24changes.
4. The START/PAUSE/CANCEL button is the primary control button for the RENEW™ system.Momentarily pressing and
releasing the button will start asequenceof water changes.Momentarilypressing and releasing thebutton during an
activesequenceofwaterchangespauses
thesequenceuntilpressedagain,atwhichtimethesequenceofwaterchanges
will resume.Pressing and holding the button for between three and five seconds will permanently cancel an active
sequenceofwaterchanges.Pressingandholdingthebuttonforfivesecondsorlongerwillpermanentlycancelanactive
sequenceofwaterchangesandwillorderthesystemtoemptytheMeteringReservoirs.
The START/PAUSE/CANCEL buttonis the only buttonthat is activeduring a sequenceof water changes.Once a water
changesequencehasbeenstarted, the system will ignoreinputfromtheotherthreebuttons until the
waterchangeis
canceledorhascompleted.
5. TheINCREASEandDECREASEbuttonssimplychangethenumberofgallonstobechanged.
6. Pressing and holding the MODE and START/PAUSE/CANCEL buttons simultaneously for five seconds accesses the
OperationSettingsfortheRENEW™system.Thesesettingsallowtheusertoset
thetypeofsystemthattheyhave(Basic,
Advanced, or Pro), andare generally not needed afterthe system is initially installed unless the systemis upgradedto
includeadditional levelsensors.OnceinOperationSettings,theINCREASEandDECREASEbuttonsareusedtoselectthe
operation mode.Basic (“b”) mode
is the default andwill need to be changed if you have an Advanced or Pro model.
Basicmodedoes not monitor level sensorinput.Advanced (“A”) mode monitors thetwostandalone level sensorsthat
are placed inthe sump (or aquarium) andreplacement bin.Pro models can be run
in two different operating modes:
standard (“PS”) orabbreviated(“PA”).Pro Standard operatingmodewill monitor all six possible level sensorsand will
adjustthecycletimesbasedonthereservoirlevelsensors’inputs,andwillincludetheStandbystageaftereachDispense
stage.Pro Abbreviated operation will function similarly, but
will skip the Standby stage and immediatelystart another
cycle when in Continuous mode.Skipping the Standby stage allows the system to exchange a volume of water more
quickly,butdoesnotallowthewaterjustreplacedtomixwiththeentireaquariumvolumeasthoroughly.
7. Thepowerswitch
canbeusedatanytimetoquicklysh utoffyourRENEW™systemandisequippedwithathermalcircuit
breakerthatwillautomaticallyshutdownthesystemifitdrawsmorethan10amps.
ExampleofOperation
Let’sassumethatyouwantyourRENEW™systemtoperforma15percentwaterchangeonyour90gallonaquariumwitha10
gallonsump.Let’salsoassumethatyouwantittoperformthechangeinasshortatimeaspossible.
Sinceyourtotalwatervolumeis100
gallons,you’llwanttoperforma15gallonwaterchange:
1. UsingtheINCREASEand/orDECREASEbuttons,adjustthevalueintheGALLONSwindowto“15”
SinceyouwantyourRENEW™systemtoperformthewaterchangeasquicklyaspossible:
2. UsingtheMODEbutton,select“CONTINUOUS”mode
Nowallyouhavetodoistellittogo!
3. PresstheSTART/PAUSE/CANCELbutton
It’sthatsimple!!!YourRENEW™systemwillperform15onegallonwaterchangesoneaftertheother.IfyouhaveanAdvancedor
Promodel,itwillevenmonitorthewaterlevelsinyour
sumpandreplacementwaterbin,andalertyouifeitherstraysoutsideyour
setlevels.Plus,ifyouhavethePromodel,theRENEW™systemwillmonitoritsownoperationandautomaticallyinterruptawater
changeandalertyouifitdeterminesthatsomethingisn’tquiterightofferingtheultimatepeaceofmind!
Feelfreetoexperimentwiththesettingsonyour
RENEW™systemtofindoutwhatbestsuitsyourneeds.Ifyouever“getlost,”and
wanttogetbacktothefactorydefaultsettings,simplyturntheunitoff,presstheINCREASEandDECREASEbuttonssimultaneously,
andwhilestillholdingthemturntheunitbackon.YourRENEW™systemwill
resetitselftothefactorydefaults.
InterruptingandCancelingaWaterChangeSequence
IfyoueverneedtopauseyourRENEW™systemwhileitisinanactivewaterchangesequence,simplypressandreleasethe
START/PAUSE/CANCELbutton.Thecurrentstageindicatorwillblinktoindicatethatthesystemispaused.Toresumethesequence,
simplypressandreleasethebuttonagain,and
yourRENEW™systemwillcontinueuntilcompleted.
Ifyoueverneedtopermanentlycancelasequence,pressandholdtheSTART/PAUSE/CANCELbuttonfor3seconds.Thestage
indicatorswillblinktoindicatethatyou’vecanceledthesequence.Youcanalsocancelasequenceanddispensethecontentsofthe
Metering
ReservoirsbypressingandholdingtheSTART/PAUSE/CANCELbuttonfor5seconds.Thestageindicatorswillblinkafter
holdingthebuttonforthreesecondstoindicatethatthecyclehasbeencanceled,andwillopentheMeteringReservoirvalvesafter
5secondstodrainanywatercontainedwithinthem.
InteractionwiththeGenesisSTORM™SpecializedTopOffandReplenishmentModule
YourRENEW™canbeconn ectedtoaGenesisSTORM™SpecializedTopOffandReplenishme ntModuletoallowbothunitstobe
installedinanaquariumsystemandworktogetherwithoutmanuallydisablingtheSTORM™.TheSTORM™willnotattempttotop
offthesumporaquariumanytimetheRENEW™
unitisactivelyperformingawaterchangecycle.ThispreventstheSTORM™from
attemptingtoreplacethewastesaltwaterremovedbytheRENEW™systemwithfreshwater.Doingsowouldadverselyaffect
salinityinasaltwateraquariumandcouldeventuallyresultinoverflowingthesumpineitherafreshwaterorsaltwater
aquarium.
TheRENEW™willindicatethatitdetectstheSTORM™viatheindicatorsinthelowercenterportionoftheControlModule,andwill
illuminatewhenitisdisablingtheSTORM’s™topofffunctionsaswell.
Troubleshooting
YourRENEW™AutomaticWaterChangeSystemisdesignedtopro videyearsofreliableservice.Thefollowingtabledescribessome
typicalsymptoms,reasons,andsolutionstosituationsthatyoumayencounter.Ifyoustillhavedifficultyorquestionsaboutyour
RENEW™system,pleasecallourcustomerservicelineoremailourcustomer
carerepresentativesforfurtherassistanceat
[email protected].Pleasehaveyoursystem’sserialnumberavailablewhenyoucallandprovideitwithany
correspondencesowemaybetterhelpyou.TheserialnumbercanbefoundonthebackoftheControlModule.
Symptom PossibleReason Solution
NoindicatorsareilluminatedonControl
Moduleandpushinganybuttonproduces
noresult
1.NoPower
2.UnitisnotturnedON
1.EnsureControlModuleisfirmly
pluggedinto110VACreceptacle.
Checkelectricalsupply’sbreakeror
fuse
2.MakesurePowerButtonisintheON
position
The“SumpLevel”and/or“BinLevel”LED
indicatorsblinkandsystemhaltsnormal
function,withablinkingstageindicator
1.Waterlevelsaretoolow
2.LevelSensorsarenotpluggedin
3.RENEW™Basicunitisconfiguredto
operatein“Advanced”or“Pro”modes
4.FaultyLevelSensor
1.
Topoffsumpand/orrefillreplacement
waterbin;afterward,press
START/PAUSE/CANCELbuttonto
resumeoperation
2.CheckLevelSensorconne ctionson
ControlModule;afterward,press
START/PAUSE/CANCELbuttonto
resumeoperation
3.Reconfiguresystemtooperatein
“Basic”mode(see“Gettingtoknow
yourRENEW™AutomaticWater
ChangeSystem”)
4.Manually
slidefloatalongsensorshaft;
ifnochange,replaceLevelSensor
The“ReservoirHigh”LEDindicatorblinks
andsystemhaltsnormalfunction,witha
blinkingstageindicator
1.TheMetering Reservoirwasnotfilled
within75secondsduringtheFillStage
2.LevelSensorsarenotpluggedin
3.FaultyLevelSensor
1.Ensurethatpumpiscapableoffilling
theMeteringReservoirwithin75
secondsatmountingheight.Also
makesurethattherearenokinksin
tubingdeliveringwatertoReservoir,
andthatinletvalves(ifused)are
open.
2.CheckReservoirconnectionson
ControlModule;afterward,press
START/PAUSE/CANCELbuttonto
resumeoperation
3.Manuallyslidefloatalongsensor
shaft;
ifnochange,replaceLevelSensor
The“ReservoirLow”LEDindicatorblinks
andsystemhaltsnormalfunction,witha
blinkingstageindicator
1.TheMeteringReservoirwasnot
emptiedwithin90secondsduringthe
DispenseStage
2.LevelSensorsarenotpluggedin
3.RENEW™BasicorAdvan cedunit is
configuredtooperatein“Pro”mode
4.FaultyLevelSensor
1.Examinedraintubingtoensurethat
therearenokinksblockingflow
2.CheckReservoirconnectionson
ControlModule;afterward,press
START/PAUSE/CANCELbuttonto
resumeoperation
3.Reconfiguresystemtooperatein
“Basic”or“Advanced”mode(see
“GettingtoknowyourRENEW™
AutomaticWater
ChangeSystem”)
4.Manuallyslidefloatalongsensorshaft;
ifnochange,replaceLevelSensor
TheMeteringReservoirdoesnot
completelyfillduringtheFillStage
1.Pumpisnotcapableofdeliveringone
gallonwithin75secondsatmounted
height
2.Tubingiskinked,inletvalveis
restrictingflow,orpump inlet is
blocked
1.Replacepumpwithhighercapacityor
lowerMeteringReservoir’smounting
height
2.Removeallkinks,openinletvalve,and
ensurepump’sinletisnotcloggedor
blocked
TheMeteringReservoirdoesnot
completelyemptyduringtheDispense
Stage
1.MeteringReservoirismountedtoolow
2.Tubingiskinkedorflowisotherwise
impeded
3.Endofoutlettubingissubmerged
belowwaterinsumporwaste
receptacle
4.Wastelineispressurized
1.RelocateMeteringReservoirsuch
that
itisalwaysabovethemaximumwater
levelofthesumporwastereceptacle
2.Removeallkinksorobstructionsand
removeallvalvesfromoutlettubing.
CheckoutletinsideMetering
Reservoirforblockage
3.Cutandmountendofoutlettubing so
thatitisjustabovethe
maximum
waterlevelofthesumporwaste
receptacle
4.Outletonwastesideisconnectedtoa
blockedorotherwisepressurized pipe.
Immediatelyseektheadviceofa
licensedplumberifyouarenot
qualifiedtoperformplumbingrepairs!
TheMeteringReservoiroverflowsduring
FillStage
1.PumpcapacitytoohighforReservoir
mountingheight
2.MeteringReservoirismountedtoolow
3.Endofreturntubingissubmerged
belowwaterinsource
4.Returntubingisroutedabovetopof
MeteringReservoir
1.Replacepumpwith
lowercapacity,
decreaseflowthroughinlettubing
usingaflowvalve,orincrease
MeteringReservoir’smountingheight
2.IncreaseMeteringReservoir’s
mountingheightsothattheentire
Reservoirisabovethemaximum
waterlevelofthesumpor
replacementwaterbin
3.Cutandmountendofreturntubingso
that
itisjustabovethemaximum
waterlevelofthesource
4.Routereturntubing suchthatitnever
goesabovethebottomofthe
Reservoir
TheMeteringReservoircontinuestofill
afterFillStageiscomplete
1.MeteringReservoirismountedbelow
waterlevelinsource(sumpor
replacementbin),andasiphonhas
beencreated
1.RaiseReservoirmountingheightto
ensureitisalwayscompletelyabove
themaximumwaterlevelofthe
source
PumpdoesnotturnonduringFillStage 1.Pumpneedsmaintenanceor
replacement
1.Unplugpumpandclearobstructions
fromimpeller(removeandcleanif
possible).Ifproblempersists,replace
pump
WaterflowingoutofMeteringReservoirs
createstoomuchnoise
1.Loudbubblingnoiseisheard.Endof
tubingissubmergedbelowwater
level.
2.Loudsplashingnoiseisheard.Endof
tubingistoohighorwaterisflowing
directlyintowatervolume.
1.Cutandmountendof
tubingsothatit
isjustabovethemaximumwater
level,suchthatthestreamofwater
exitingthetubeflowsdowntheside
ofthereceptacle
2.Mountendoftubingsothatitisjust
abovethemaximumwaterlevel,such
thatthestreamofwaterexitingthe
tube
flowsdownthesideofthe
receptacle
Product Use
Many factors beyond Genesis Reef Systems’ control and uniquely within the user’s knowledge and control can affect the use and performance of a Genesis Reef
Systems product in a particular application. Given the variety of factors that can affect the use and performance of a Genesis Reef Systems product, the user is
solely responsible for evaluating the Genesis Reef Systems product and determining whether it is fit for a particular purpose and suitable for the user’s method of
application.
Limited Warranty
Genesis Reef Systems warrants for 6 months from the date of purchase that Genesis Reef Systems products will be free of defects in material and manufacture.
Genesis Reef Systems makes no other warranties, express or implied, including but not limited to, any implied warranty of merchantability or fitness for a particular
purpose. This limited warranty does not cover damage resulting from use or misuse of a Genesis Reef Systems product, workmanship in application, or application
or storage not in accordance with Genesis Reef Systems recommended procedures. This warranty does not apply to products not directly manufactured by Genesis
Reef Systems or consumable items that may degrade as part of normal use.
Limitation of
Remedies and
Liability
If the Genesis Reef Systems product is proved to be defective within the warranty period stated above the exclusive remedy, at Genesis Reef Systems’ option, shall
be to refund the purchase price of or to repair or replace the defective Genesis Reef Systems product. Genesis Reef Systems shall not otherwise be liable for loss or
damages, whether direct, indirect, special, incidental, or consequential, regardless of legal theory asserted, including negligence, warranty, or strict liability.
/