WARNING!!! ALWAYS TURN OFF THE POWER AND UNPLUG
THE AQUARIUM BEFORE SERVICING
*Please read the instructions thoroughly before you begin servicing*
Tools Needed:
1. Middle size Philips head screwdriver
2. Small size Flat head screwdriver
Step 1
Make sure the power cord is unplugged and
the tank is off.
Now remove the frame from the aquarium as you
would do so normally.
Step 2
Locate the round blue sticker which can be found at
the top right hand corner of the tank.
Remove the screw that is located behind the round
blue sticker using a small size flathead screwdriver.
1
Step 3
The side panel is located on the same side as
the LCD screen and keypad.
You can now remove the side panel by placing
your screwdriver in the crack located at the top
of the aquarium’s side panel.
2
White cord to white
circuit board
Black cord to black
circuit board
B
A
Step 4
Now gently push down roughly ½ inch and the
panel should come off. The side panel where the
LCD screen and keypad are located will be attached
to the circuit board so be careful not to pull too hard
on the cords when removing the side panel.
Step 5
Unplug the 2 connectors from the LCD and
keypad to the circuit board.
You should now have the LCD screen and keypad
free from the rest of the circuit board and aquarium.
Remove light connector,
replace with water power
Step 6
Take out water power wire
to place into light connector
Step 7
Reconnect the LCD and keypad, and fit the
control panel back to the aquarium by sliding
it up roughly ½ inch.
Step 8
If everything is connected properly and the
power cord is free of any water splashes,
you may plug the power cord in and reset
the clock on the control panel.
Press light button on the keypad, that will feed the
power to water pump, we want to confirm if the
water pump is pumping water.
3
Step 9
If the water pump is pumping water, it means the
water pump relay on the circuit board is bad.
The next step is to replace the circuit board.
If the water pump is not pumping water, it means
the water pump has died, that needs to be replaced.
Thank You for Your Time and Patience!