75
8 007 936/N079/17-12-02 © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Operating instructions
LCU-X
GB
6 Technical Data
Electrical Connections
Chapter 6
min. typ. max.
Protection class I
Housing protection IP 65 (switch cabinet,
standard rail)
Supply voltage U
V
19.2 V 24 V 28.8 V
Ripple
1
)
Voltage if power fails (20 ms) 18 V
Power concumption (no load) 0.3 A (6 W)
Inputs Command unit Start key
T 13, T 14 NO contact
Command unit actuation time period 30 ms
Contactor monitoring
T 21, T 22 contactor monitoring NC contacts in series
Permissible contactor drop-off time No restrictions
Permissible contactor response time 200 ms
Sensor signal T 3, T 4 Two-channel
Input resistance (active) 606 Ω 674 Ω 742 Ω
Signal active at 17.6 V U
V
Signal LOW at 0 V 2.4 V
Time period tolerance between T 3 and T 4 15 ms
Outputs Relays with positively guided contacts
Response time 15 ms
2
)
Switching current < 0.1 mA
3
)4 A
Switching voltage AC / DC 240 V AC /
60 V DC
Switching AC / DC 1200 VA /
50 W
Mech. life expectancy (switch actions) 10
7
Elec. life expectancy (switch actions) 10
5
Delay on Energisation (NO contacts) 40 ms
Delay on Energisation (NC contacts) 15 ms
Supply voltage U
V
Connection Pluggable strip terminal
Cable cross section 2.5 mm
2
Load capacity of terminals
(C 1 ... 4, D 1 ... 4) 2.5 A
Operating data
Safety category Type 4
Tested to pr EN 50 100 Part 1 and 2
Creepage and clearance distance between
the electric circuits to VDE 0110:
Measured transient/surge voltage (U
Imp.
)4 kV
Overload voltage category III