INSTALLATIONGUARDS
1. Disconnect POWER before installation
2. Verify all parts are accounted for. Check power supply connections.
3. If required, connect the IR Sensor OR the Wall Dimmer to the port as
indicated on the power supply.
4. Connect to VAC following wiring lables.
Lables will indicates:
120VAC or 277VAC 50-60Hz
L (black) Line / Hot
N (white) Neutral / Common
G (green) Ground
5. Network Connection from PRIMARY output to input on SECONDARY unit.
Unit with IR connection or 0-10V Wall Dimmer becomes PRIMARY
automatically.
6. Mounting Options:
a) Grid / T-Bar (secure luminaraire in grid / ceiling T-bar.)
b) Suspension Cable installation (connect suspension cable kit
according to indicated mounting dimensions.
Adjust cables to balance luminaire.)
c) Recess Wall (cut hole in drywall, secure mounting bracket,
connect safety cable, make electrical connection, slide luminaire in place.)
d) Surface mount (assembel 3 sides of frame and mount securely,
insert luminaire, align final section of frame and secure with screws.
7. Turn on power VAC.
LED LIGHT PANEL
PLANEXTM
INSTRUCTION
GRID / SUSPENSION / RECESS / SURFACE
120VAC or 277VAC 50 - 60HZ INPUT
1X1 OR 2X2 CONFIGURATIONS
IMPORTANT SAFETYGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- Do not let power cords touch hot surfaces.
- Do not mount near gas or electric heaters.
- Equipment should be mounted in locations and at heights where
unauthorized personnel will not readily subject it to tampering.
- The use of accessory equipment not recommended by Beghelli
Inc., may cause an unsafe condition, and will void the warranty.
- Do not use this equipment for other than its intended purpose.
- Servicing of this equipment should be performed by qualified
service personnel.
SAVE THESE INSTRUCTIONS!
EACH MODEL NUMBER CONSISTS OF THE FOLLOWING:
SERIES / LED COLOR TEMP. / INPUT
Series: PLANEXTM (1’X1’) / (2’X2’)
LED / COLOR-
TEMP.
WT35 (3500K)
WT55 (5500K)
Input 120VAC or 277VAC 50 - 60HZ INPUT
IMPORTANT SAFEGUARDS
No User serviceable parts. Refer service to a qualified service technician.
Read instructions prior to installing and /or operating this device.
Installation should be performed by a licensed electrician / installer
in accordance with local codes.
WARNING
111512
SUSPENSION
MOUNT TABS
POWER SUPPLY
LENS DIFFUSER
IR SENSOR PORT OR
0-10V WALL DIMMER PORT
ALUMINUM FRAME
Beghelli Canada Inc.
3900 14th Avenue
Markham, Ontario L3R 4R3 Canada
Tel (905) 948-9500 / Fax (905) 948-8673
www.Beghellicanada.com
Beghelli USA
3250 Corporate Way, Unit A
Miramar, FL 33025 USA
P: (954) 442-6600 / F: (954) 442-6677
www.beghelliusa.com
Beghelli MEXICO
Av El Marques No. 70, Interior 4
Parque Industrial Bernardo Quintana
76246 Mpio. El Marquez
Queretano, QRO. Mexico
P: +52 442-221-6439 / F: +52 442-221-6215
www.beghellimexico.com
CONTACT US
NETWORK
OUT IN
Gray
Red
Black
Purple
IR VR/Z
OUT
NETWORK
IN
Buffer
GNL
IR
GNL
OUTPUT
INPUT
INSTALLATION
GNL
IR sensor
Standard
L (BLACK) LINE / HOT
N (WHITE) NEUTRAL / COMMON
G (GREEN) GROUND
(IE: W/ DOUBLE SIDED TAPE, SECURELY ATTACH THE IR SENSOR DIRECTLY
TO THE GRID / CEILING.)
MAIN AC
120VAC or 277VAC
MAIN AC
120VAC or 277VAC
MAIN AC
120VAC or 277VAC
IR SENSOR
0-10V Wall dimmer
Network Connections (optional)
PRIMARY
FOR ALL CONFIGURATIONS (Use RJ11 network head)
SECONDARY SECONDARY
L (BLACK) LINE / HOT
N (WHITE) NEUTRAL / COMMON
G (GREEN) GROUND
0-10V WALL DIMMER
(PROVIDED BY OTHERS)
(MAX 10 UNITS ALLOWED)
(NOTE: USE RJ11 CABLES, MAX 16.5FT/5 METERS IN LENGTH)
CONNECT TO VAC
CONNECT TO VAC for switch wiring details,
please refer to manufacturers installation guide.
CATALOG CODE WMD
CATALOG CODE DM
NETWORK
OUT IN
NETWORK
OUT IN
NETWORK
OUT IN
NETWORK
OUT IN
NETWORK
OUT IN
NETWORK
OUT IN
Suspension Mount Detail
Suspension Cable Mounting Dimensions
CROSS BAR
CANOPY
CABLE GRIPPER
ZIP TIES
AIRCRAFT CABLE
ZIP TIES
POWER CORD
GRIPPER
SET SCREW / PIN
J-BOX
(PROVIDED BY OTHERS)
D
CB
A
PlanexTM
DIM A B C D
1X1 11.75” 2.05” 2.20” 22.5”
298.45mm 53.0mm 55.88mm 571.5mm
2X2 23.75” 2.05” 2.20” 11.5”
603.25mm 53.0mm 55.88mm 293mm
T-Bar / Grid Installation
SUSPENSION CABLE MOUNT
CABLE MOUNTING TABS (X4)
MOUNTING
CATALOG CODE GRD
CATALOG CODE SPS50
CATALOG CODE SPS
CATALOG CODE SPS
CUT HOLE FOLLOWING DIMENSION
AND SECURE WITH PROPER SCREWS.
(PROVIDED BY OTHERS)
ASSEMBLE ALL FOUR SIDES OF THE
FRAME.
SECURE FRAME INTO POSITION (HARDWARE
PROVIDED BY OTHERS) AND THEN REMOVE
ONE SIDE OF THE FRAME.
INSERT LUMINAIRE INTO THE SECURED FRAME.
MAKE SURE TO PROPERLY ALIGN LUMINAIRE
WITH FRAME SLOT (SEE DETAIL A).
WITH LUMINAIRE ALL THE WAY IN AND
SECURE, INSTALL THE FINAL FRAME
SECTION AND TIGHTEN.
SECURE MOUNTING BRACKET
TO SAFETY CABLE
CONNECT AC AND THEN SLIDE
LUMINAIRE INTO PLACE.
7.00”
5.80”
3.00”
Recess Wall Installation
Surface Mount Installation
MOUNTING
FINAL VIEW FRAME/FIXTURE
DETAIL A
CATALOG CODE RWM
4 typical 1/4” holes
CATALOG CODE SM
/