Steelcase Technology Wall - Floor to Ceiling, Junctions and Trims User manual

Type
User manual
Page 1 of 14
939500174 Rev B
Pathways
®
Technology Wall - Floor to Ceiling,
Junctions and Trims
®
If you have a problem, question, or request, call
your local dealer, or Steelcase Line 1 at
888.STEELCASE (888.783.3522)
for immediate action by people who want to help you.
(Outside the U.S.A., Canada, Mexico, Puerto Rico,
and the U.S. Virgin Islands, call: 1.616.247.2500)
Or visit our website: www.steelcase.com
©
2004 Steelcase Inc.
Grand Rapids, MI 49501
U.S.A.
Printed in U.S.A.
#2 PHILLIPS
3/16" HEX x 2" LONG DRIVE
BALL DRIVE
3" LONG
2" LONG
3/16" HEX x 3" LONG
Table of Contents
Page
2 Components
3 Notes
4 L-Junction, Full Height
5 T-Junction, Full Height
6 X-Junction, Full Height
7 Y-Junction, Full Height
8 V-Junction, Full Height
9 End of Run Trim, Full Height
10 End of Run Trim, Change of Height
11 T-Junction, Change of Height
12 L-Junction, Change of Height
13 V-Junction, Change of Height
14 Light Seals
Topic
Page 2 of 14
939500174 Rev B
1
2
5
Junction
Bracket
Top Plate
Assembly
L, T, X
3
4
Top Block
Assembly
L, T, X
15
1/4-20 x 1"
Screw
16
5/16-18 x 1"
Bolt
Bottom Block
Assembly
L, T, X
17
#8-18 x .360"
Pan Head
Screw
Components
Y, V
6
Y, V
7
8
Y, V
EOR Clip
9
EOR
Trim
L-Trim
no cap
T-Trim
no cap
V-Trim
no cap
Light Seal Light Seal
L, T & X
Y & V
18
Aligner Bracket
19
Horizontal COH
Alignment Clip
20 21
10 11 12 13 14
or
Vertical Aligner
Bracket
Vertical Aligner
Junction Trim
Bracket
Page 3 of 14
939500174 Rev B
1. All floor to ceiling junctions and
trims logic is the same as partial
height, reference AD 939501684.
2. An additional trim holder (junction
block) is required above 84" to support
the trim, and if the application allows,
the junction block should be supported
by two (2) junction brackets.
3. Junction blocks are required at 66"
and 84" for all floor to ceiling
configurations.
4. When junction style calls for a
change of height T-trim or L-trim,
insert the horizontal aligner bracket
into the bottom end of trim. Install trim
and be sure to seat aligner down into
frame.
HORIZONTAL
ALIGNER
BRACKET
END TRIM
19
1
15
3 6
or
15
16
84"
Page 4 of 14
939500174 Rev B
L-Junction
Style No. C120LJ
1. Once the transom structure and
skin assembly is complete, measure
the distance from the floor to the
ceiling track
.
2. Cut the L-trim 7/8" longer than the
dimension found in step 1.
3. Snap the L-trim on to the trim
holders, putting the cut end inside the
ceiling track.
Note: The transom trim holder can be
mounted above or below the factory-
provided location by using the junction
bracket as a template and drilling
two (2) 9/64" diameter pilot holes.
Tip: Position the transom trim holder
with item 15 to the best support the
trim.
10
1
1
2
1
1.
7/8"
84"
66"
4
3
3
3
Page 5 of 14
939500174 Rev B
T-Junction
Style No. C120TJ
1. Once the transom structure and
skin assembly is complete, measure
the distance from the floor to the
ceiling track
.
2. Cut the T-trim 7/8" longer than the
dimension found in step 1.
3. Snap the L-trim on to the trim
holders, putting the cut end inside the
ceiling track.
Note: The transom trim holder can be
mounted above or below the factory-
provided location by using the junction
bracket as a template and drilling two
(2) 9/64" diameter pilot holes.
Tip: Position the transom trim holder
with item 15 to the best support the
trim.
11
1
1
2
1
1
1
2
1
4
3
3
3
1.
7/8"
84"
66"
Page 6 of 14
939500174 Rev B
X-Junction
Style No. C120XJ
1
1
2
1
1
1
2
1
1
1
2
1
4
3
3
3
84"
66"
Page 7 of 14
939500174 Rev B
Y-Junction
Style No. C120YJ
1
1
5
1
1
1
5
1
84"
66"
7
6
6
6
Page 8 of 14
939500174 Rev B
V-Junction
Style No. C120VJ
1. Once the transom structure and
skin assembly is complete, measure
the distance from the floor to the
ceiling track
.
2. Cut the V-trim 7/8" longer than the
dimension found in step 1.
3. Snap the V-trim on to the trim
holders, putting the cut end inside the
ceiling track.
Note: The transom trim holder can be
mounted above or below the factory-
provided location by using the junction
bracket as a template and drilling
two (2) 9/64" diameter pilot holes.
Tip: Position the transom trim holder
with item 15 to the best support the
trim.
1
1
5
1
1.
7/8"
84"
66"
7
6
6
6
Page 9 of 14
939500174 Rev B
End of Run Trim
Style No. C120ERT
1. Once the transom structure and
skin assembly is complete, measure
the distance from the floor to the
ceiling track
.
2. Cut the End of Run trim 5/8"
longer than the dimension found in
step 1.
3. Stand the trim adjaqcent to the
end of the panel and mark the clip
locations on the back side.
4. Slide the clips on to the trim from
the end to the proper position.
5. Snap the trim on to the frame,
putting the cut end inside the ceiling
track.
Note: Position the clips to best
support the trim based on the available
9
8
8
8
8
1.
5/8"
84"
66"
Page 10 of 14
939500174 Rev B
Change of Height Trim
Style No. C78CCT
1. Once the transom structure and
skin assembly is complete, measure
the distance from the top cap to the
ceiling track
.
2. Cut the End of Run trim 5/8" longer
than the dimension found in step 1.
3. Stand the trim adjacent to the end
of the panel and mark the clip locations
on the back side.
4. Slide the clips on to the trim from
the end to the proper position.
5. Snap the trim on to the frame,
putting the cut end inside the ceiling
track.
Note: Position the clips to best support
the trim based on the available clip
locations.
1.
5/8"
84"
66"
9
8
8
8
Page 11 of 14
939500174 Rev B
T-Junction trim
Change of Height Trim
Style No. C78CTSJ
1. Once the transom structure and
skin assembly is complete, measure
the distance from the frame top to the
ceiling track
.
2. Cut the T-trim 7/8" longer than the
dimension found in step 1.
3. Measure the distance from the
frame top to the top of the trim holder
above.
4. Secure the aligner bracket from
the bottom (uncut end) of the T-trim
1/16" greater than the dimension
found in step 3.
5. Snap the T-trim on to the trim
holders, putting the cut end inside the
ceiling track.
Note: The transom trim holder can be
mounted above or below the factory-
provided location by using the junction
bracket as a template and drilling two
(2) 9/64" diameter pilot holes.
Tip: Position the transom trim holder
with item 15 to the best support the
trim.
1.
7/8"
1/16"
84"
66"
11
19
3
3
20
17
3.
1
2
1
14
2
13
TOP VIEW
TOP VIEW
Page 12 of 14
939500174 Rev B
Style No. C78CLSJ
1. Once the transom
structure and skin assembly
is complete, measure the
distance from the frame top
to the ceiling track
.
2. Cut the L-trim 7/8"
longer than the dimension
found in step 1.
3. Measure the distance
from the floor to the frame
top.
4. Cut the T-trim 1/16" 
shorter than the dimension
found in step 3.
5. Secure the aligner
bracket between the L and T
trim, putting the cut ends of
the trims at the floor and the
ceiling.
6. Snap the trim on to the
trim holders.
Note: The transom trim
holder can be mounted
above or below the factory-
provided location by using
the junction bracket as a
template and drilling two (2)
9/64" diameter pilot holes.
Tip: Position the transom
trim holder with item 15 to
the best support the trim.
1.
3.
7/8"
84"
66"
11
17
18
3
1
2
3
L-Junction trim
Change of Height Trim
3
1 2
TOP VIEW
4
1 1
TOP VIEW
Style No. C78CVSJ
1. Once the transom
structure and skin assembly is
complete, measure the
distance from the frame top to
the ceiling track
.
2. Cut the V-trim 7/8" longer
than the dimension found in
step 1.
3. Measure the distance
from the frame top to the top
of the trim holder above.
4. Secure the aligner bracket
from the bottom uncut end of
the V-trim 1/16" greater than
the dimension found in step 3.
5. Snap the V-trim on to
the trim holders, putting the
cut end inside the ceiling
track.
Note: The transom trim
holder can be mounted
above or below the factory-
provided location by using
the junction bracket as a
template and drilling two (2)
9/64" diameter pilot holes.
Tip: Position the transom
trim holder with item 15 to
the best support the trim.
V-Junction trim
Change of Height Trim
1.
3.
7/8"
1/16"
84"
66"
1
1
1
5
6
6
6
21
17
7
1
5
12
Page 13 of 14
939500174 Rev B
Page 14 of 14
939500174 Rev B
Light Seals
1. Install all partial height light
seals before the transom stackers
are assembled, reference
assembly instruction 939501684.
2. Cut the light seal to length for
the transom area, putting a 45
o
bevel on the lower end.
3. Install the light seal in a similar
manner as partial height, tucking
the bevelled end behind the partial
height seal.
Tip: Ceiling tiles may be removed
to aid the assembly of the transom
light seals.
45
o
45
o
13 14
or
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Steelcase Technology Wall - Floor to Ceiling, Junctions and Trims User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI