Triton Systems FT5000 Xscale Series Owner's manual

Type
Owner's manual
CORPORATE HEADQUARTERS: RMA (RETURN MATERIAL AUTHORIZATION)
R
ETURN A DDRESS:
522 E. Railroad Street 21405 Avenue “B”
Long Beach, MS 39560 Long Beach, MS 39560
PHONE: (228) 868-1317
FAX: (228) 868-0437
MODEL FT5000
A
UTOMATED TELLER MACHINE
SITE PREPARATION AND
INSTALLATION GUIDE
VERSION 4.0
TDN 07100-00004D 02/2006
COPYRIGHT NOTICE
© 2003 - 2006 Delaware Capital Formation, Inc. All Rights Reserved. TRITON,
TRITON WHERE MONEY COMES FROM, TRITON WAVES, DOVER and DO-
VER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned
subsidiary of Dover Corporation.
2
FEDERAL COMMUNICATIONS COMMISSION (FCC) COMPLIANCE
Statement of Compliance: This equipment complies with Part 68 of the FCC rules.
Located in the control area of the Automated Teller Machine (ATM) is the product
label. This label lists the FCC registration number and ringer equivalence number of
the unit. If requested, this information must be provided to the telephone company.
USCO/FIC Codes: When ordering service from the telephone company for the
FT5000 ATM, the following information should be supplied:
Universal Service Order Code (USOC): RJ-11C
The Facility Interface Code (FIC): 02LS2
Plug and Jack: The plug and jack used to connect this equipment to premise wiring
and telephone network must comply with the applicable FCC Part 68 rules and
requirements adopted by ACTA. A compliant telephone cord and modular plug is
provided with this product. The telephone cord is designed to be connected to a
compatible modular jack that is also compliant.
Ringer Equivalent Number (REN): The REN is used to determine the number of the
devices that may be connected to a telephone line. Excessive RENs on a telephone
line may result in the devices not ringing in response to an incoming call. In most but
not all areas, the sum of the RENs should not exceed five (5). To be certain of the
number devices that may be connected to a line, as determined by the local RENs,
contact the local telephone company.
Harm to the Network: If the FT5000 ATM causes harm to the telephone network, the
telephone company will notify the customer that a temporary discontinuous of
service may be required. If advanced notice is not possible, the telephone company
will notify the customer as soon as possible. You will be advised of your right to file
a complaint with the FCC if you believe it’s necessary.
Notification of Changes in Telephone Company Equipment: The telephone company
may make changes in its facilities, equipment, operations, or procedures that could
affect the operation of the equipment. If this happens, the telephone company will
provide advanced notice in order for you to make necessary modifications to maintain
uninterrupted service.
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
** CAUTION **
Changes or modifications not expressly approved by Triton
Systems could void the regulatory compliance approval
and the warranty. Use of this product in a manner other
than those described in this manual may result in personal
injury!
3
If the equipment is causing harm to the network, the telephone company may request
that you disconnect the equipment until the problem is resolved. Repairs should be
made only by qualified factory representatives.
Party Lines: The FT5000 ATM must not be used on party lines.
Alarm Equipment: The FT5000 ATM should have its own dedicated phone line. Do
not install the FT5000 on the same line as alarm equipment.
Electrical Safety Advisory: telephone companies report that electrical surges, typically
lightening transients, are very destructive to customer equipment connected to AC
power sources. This has been identified as a major nationwide problem. A
commercially available, power surge suppressor, is recommended for use with the
FT5000 to minimize damage in the event of an electrical surge.
CANADIAN IC COMPLIANCE
NOTICE:
The Industry Canada label identifies certified equipment. This certification means
that the equipment meets telecommunications network protective, operational and
safety requirements as prescribed in the appropriate terminal equipment technical
requirements document(s). The department does not guarantee the equipment will
operate to the users satisfaction.
Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The equip-
ment must also be installed using an acceptable method of connection. The cus-
tomer should be aware that compliance with the above conditions may not prevent
degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative desig-
nated by the supplier. Any repairs or alterations made by the user to this equipment,
or equipment malfunctions, may give the telecommunications company cause to
request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections
of the power utility, telephone lines, and internal metallic water pipe system, if present,
are connected together. This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should
contact the appropriate electric inspection authority, or electrician, as appropriate.
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
Repairs and Returns: If telecom compatibility trouble is experienced with the FT5000
ATM, you may contact for repairs and warranty information: Triton at 1-228-868-
1317
Triton Systems of Delaware, Inc.
522 East Railroad Street
Long Beach, MS 39560
4
NOTICE:
The REN assigned to each terminal device provides an indication of the maximum
number of terminals allowed to be connected to a telephone interface. The termina-
tion on an interface may consist of any combination of devices subject only to the
requirement that the sum of the RENs of all the devices does not exceed 5.
AVIS:
L’étiquette d’Industrie Canada identific le matériel homologué. Cette étiquette certifie
que le matériel est conforme aux normes de protection, d’exploitation et de sécurité
des réseaux de télécommunications, comme le prescrivent les documents concernant
les exigences techniques relatives au matériel terminal. Le Ministère n’assure toutefois
pas que le matériel fonctionnera à la satisfaction de l’utilisateur.
Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder
aux installations de 1’entreprise locale de télécommunication. Le maté-riel doit
également être installé en suivant une méthode acceptée de raccordement. L’abonné
ne doit pas oublier qu’il est possible que la comformité aux conditions énoncées ci-
dessus n’empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel homologué doivent être coordonnées par un représentant
désigné par le fournisseur. L’entreprise de télécommunications peut demander à
I’utilisateur de débrancher un appareil à la suite de réparations ou de modifications
effectuées par l’utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la
terre de la source d’énergie électrique, des lignes téléphoniques et des canalisations
d’eau métalliques, s’fl y en a, sont raccordés ensemble. Cette précaution est
particulièrement importante dans les régions rurales. Avertissement: L’utilisateur ne
doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à an service
d’inspection des installations électriques, ou à un électricien, selon le cas.
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
UNITED KINGDOM
This equipment has been approved in accordance with Council Decision 98/482/EC
for pan-European single terminal connection to the Public Switched Telephone
Network (PSTN). However, due to differences between the individual PSTNs pro-
vided in the different countries, the approval does not, of itself, give unconditional
assurance of successful operation on every PSTN network termination point. In the
event of problems, contact your equipment supplier in the first instance. This unit
uses only Dual-Tone Multi-Frequency (DTMF) address signaling.
5
EMISSIONS (EMI)
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two (2) conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that
may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the users authority to operate the equipment.
CANADIAN EMISSION REQUIREMENTS
This digital apparatus does not exceed the Class A limits for radio noise emissions
from digital apparatus set in the Radio Interference Regulations of the Canadian
Department of Communications. This Class A digital apparatus complies with
Canadian ICES-003.
Le present appareil numerique n’emet pas de bruits radioelectriques depassant les
limites applicables aux appareils numeriques de la Class A prescrites dans le Reglement
sur le brouillage radioelectrique edicte par le ministere des Communications du
Canada. Cet appareil numerique de la classe A est conforme a la norme NMB-003
Canada.
UK / AUSTRALIAN EMISSION REQUIREMENTS
Warning:
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
AVIS:
L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal
indique le nombre maximal de terminaux qui peuvent étre raccordés à une interface.
La terminaison d’une interface téléphonique peut consister en une combinaison de
quelques dispositifs, à la seule condition que la somme d’indices d’équivalence de
la sonnerie de tous les dispositifs n’exède pas 5.
6
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
What’s in This Installation Guide
This Installation Guide provides information for the preparation and installation of
the FT5000 ATM. It contains requirements for site preparation, electrical specifica-
tions, and cabinet accessibility that comply with all relevant codes, laws and regu-
lations. The Installation Guide is divided into the following sections:
Introduction. Summarizes the basic steps that must be completed to physically
install a FT5000 ATM. Configuration of operating parameters is not covered!
Refer to the applicable Configuration and/or Service Manual for instructions
on configuring the operating parameters.
ATM Installation for Accessibility. Describes the basic Americans with
Disabilities Act (ADA) requirements for ATM location and access. Note: These
are the general requirements that should be applicable to most installation
locations. Please verify the specific requirements with the state where the
ATM is to be installed, prior to installation. For state contact information, you
may call the ADA information line at 1-800-514-0301.
ATM Environmental Precautions Checklist. Describes the general
environmental precautions considered when installing the ATM. To help ensure
proper operation of the ATM, ensure the environmental criteria listed in this
checklist are met.
Site Preparation/Installation. Describes site preparation for exterior wall or
vestibule locations. Instructions provide dimensions/clearances needed to
install the FT5000 and procedures for installing the cabinet and front fascia.
NEW - Optional platforms (“plinths”) available in 2 sizes expediate raising
the unit, if needed. [ P/N 06100-00071 (2-3/8") and P/N 06100-00072 (4-
3/4")] Also, cabinets now come with their own leveling feet .
Power and Communication. Describes how to connect the ATM to the facility
power and telephone connections.
Dispensing Mechanism Installation. Describes how to install/remove the
dispensing mechanism into the ATM security cabinet.
Installing the Rear Service Panel (RSP). Describes how to install and connect
the RSP to the cabinet sleeve.
TCP/IP (Ethernet) Cable Installation. Describes where to install the
10Base-T CAT-5 cable for Ethernet communication.
VSAT Cable Installation. Describes where to install the optional VSAT cable.
7
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
INTRODUCTION
This document contains the information necessary for the preparation and
installation of a FT5000 Triton ATM. It’s important that the site complies with the
requirements specified in this document. In addition, electrical wiring and
mechanical systems must also comply with all relevant laws and regulations.
The site must be prepared by the customer or his agent who is fully conversant
with the requirements of installing through-the-wall ATM equipment. The
responsibility for ensuring that the site is prepared in compliance with this
document remains with the customer.
For information and guidance only, a list is provided in general terms of those
matters for which the customer is responsible. The list is not intended to be
comprehensive and in no way modifies, alters, or limits the responsibility of the
customer for all aspects of adequate site preparation.
1. Location of the equipment and site preparation.
2. Site wiring (power, communication).
3. Location of other equipment that may cause electrical, electromagnetic, or
heat induced interference.
4. Make building alterations to meet wiring and other site requirements.
5. Install all communication cables, wall jacks, and associated hardware.
6. Provide and install necessary power distribution boxes, conduits and
grounds.
7. Ensure all applicable codes, regulations and laws (electrical, building, safety)
are adhered to.
8. Ensure the environmental requirements of this unit are met.
9. Install the unit at a height which meets the ADA accessibility regulations
for the state/country installed.
THIS PAGE INTENTIONALLY LEFT BLANK
8
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
9
ATM INSTALLATION FOR ACCESSIBILITY
A Guide to the New ADA-ABA Accessibility Guidelines
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
On July 23, 2004, the U.S. Access Board, an independent Federal agency,
issued updated accessibility guidelines for new or altered facilities covered by
Americans with Disabilities Act and the Architectural Barriers Act. These
guidelines address a wide range of facilities in the private and public sectors.
Presented here is an overview of the new guidelines that also highlights sig-
nificant changes.The following guidelines (305 and 308) pertain to floor/
ground space and reach ranges.
When will the new guidelines take effect?
The Board’s guidelines are not mandatory on the public, but instead serve as
the baseline for enforceable standards (which are) maintained by other Federal
agencies. In this respect, they are similar to a model building code in that they
are not required to be followed except as adopted by an enforcing authority.
Under the ADA, the Department of Justice (and in the case of transit facilities,
the Department of Transportation) are responsible for enforceable standards
based on the Board’s guidelines. These agencies will update their ADA stan-
dards based on the new guidelines. In doing so, they will indicate when the new
standards are to be followed. Several other agencies (the General Services Ad-
ministration, Department of Defense, Department of Housing and Urban Devel-
opment, and the U.S. Postal Service) hold a similar responsibility for standards
used to enforce the ABA.
Existing Facilities
The ADA and ABA guidelines cover new construction and planned alterations
and generally do not apply to existing facilities except where altered. Facilities
built or altered according to earlier versions of the ADA or ABA standards will
not necessarily have to meet the updated version except where they are subse-
quently altered or renovated. The Department of Justice, which regulates re-
quirements for existing facilities under the ADA, intends to address coverage of
facilities built or altered according to the original ADA standards in its rulemaking
to update the standards. It will also address facilities retrofitted under ADA
provisions for existing facilities, such as the requirement for barrier removal in
places of public accommodation. With respect to ABA facilities, the Board has
clarified in the guidelines that facilities built to earlier ABA standards are subject
to the new requirements only in relation to planned alterations.
10
ATM INSTALLATION FOR A CCESSIBILITY
305 Clear Floor or Ground Space
305.1 General. Clear floor or ground space shall comply with 305.
305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or
ground space shall comply with 302. Changes in level are not permitted.
EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) mini-
mum by 48 inches (1220 mm) minimum.
305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or
ground space shall be permitted to include knee and toe clearance com-
plying with 306.
305.5 Position. Unless otherwise specified, clear floor or ground space shall be
positioned for either forward or parallel approach to an element.
305.6 Approach. One full unobstructed side of the clear floor or ground space
shall adjoin an accessible route or adjoin another clear floor or ground
space.
Figure 305.3 Clear Floor or Ground Space
Figure 305.5 Position of Clear Floor or Ground Space
11
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
305.7 Maneuvering Clearance. Where a clear floor or ground space is located
in an alcove or otherwise confined on all or part of three sides, additional
maneuvering clearance shall be provided in accordance with 305.7.1 and
305.7.2.
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm)wide mini
mum where the depth exceeds 24 inches (610 mm).
Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide mini-
mum where the depth exceeds 15 inches (380 mm).
Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
308 Reach Ranges
308.1 General. Reach ranges shall comply with 308.
308.2 Forward Reach.
308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward
reach shall be 48 inches (1220 mm) maximum and the low forward reach
shall be 15 inches (380 mm) minimum above the finish floor or ground.
12
ATM INSTALLATION FOR A CCESSIBILITY
Figure 308.2.1 Unobstructed Forward Reach
308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruc-
tion, the clear floor space shall extend beneath the element for a distance
not less than the required reach depth over the obstruction. The high for-
ward reach shall be 48 inches (1220 mm) maximum where the reach depth
is 20 inches (510 mm) maximum. Where the reach depth exceeds 20 inches
(510 mm), the high forward reach shall be 44 inches (1120 mm) maxi-
mum and the reach depth shall be 25 inches (635 mm) maximum.
Figure 308.2.2 Obstructed High Forward Reach
308.3 Side Reach.
308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel ap-
proach to an element and the side reach is unobstructed, the high side
reach shall be 48 inches (1220 mm) maximum and the low side reach
shall be 15 inches (380 mm) minimum above the finish floor or ground.
EXCEPTIONS: 1. An obstruction shall be permitted between the clear floor or
ground space and the element where the depth of the obstruction is 10 inches (255
mm) maximum.
2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm)
maximum measured from the surface of the vehicular way where fuel dispensers are
installed on existing curbs.
13
14
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
Figure 308.3.1 Unobstructed Side Reach
308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a
parallel approach to an element and the high side reach is over an obstruc-
tion, the height of the obstruction shall be 34 inches (865 mm) maximum
and the depth of the obstruction shall be 24 inches (610 mm) maximum.
The high side reach shall be 48 inches (1220 mm) maximum for a reach
depth of 10 inches (255 mm) maximum. Where the reach depth exceeds
10 inches (255 mm), the high side reach shall be 46 inches (1170 mm)
maximum for a reach depth of 24 inches (610 mm) maximum.
EXCEPTIONS: 1. The top of washing machines and clothes dryers shall be permit-
ted to be 36 inches (915 mm) maximum above the finish floor.
2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm)
maximum measured from the surface of the vehicular way where fuel dispensers are
installed on existing curbs.
Figure 308.3.2 Obstructed High Side Reach
15
ATM INSTALLATION FOR
ACCESSIBILITY
1. This document supersedes all other
information provided by Triton for
ATM installation for accessibility.
2. Information provided in this
manual is based on federal guide-
lines (ADA Accessibility Guidelines
for Buildings and Facilities –
ADAAG)as amended through
January 1998. You should verify it
has not been amended. States may
also have accessibility codes.
These codes may be more restric-
tive than the federal guidelines.
Please verify this with the state
where the ATM is to be installed
prior to installation. For state con-
tact information, you may call the
ADA information line.
3. For countries other than the US,
please use the guidelines for ac-
cessibility for that country.
4. A complete copy of the ADAAG
referred to here can be found at
http://www.access-board.gov. In-
cluded in this document is the sec-
tion of the ADAAG specifically for
ATMs. For additional information
on floor surfaces and other
ADAAG requirements, please see
the complete specification.
4.34 Automated Teller Machines.
4.34.1 General. Each machine re-
quired to be accessible by 4.1.3
shall be on an accessible route and
shall comply with 4.3.4.
4.34.2 Clear Floor Space. The auto-
mated teller machine shall be lo-
cated so that clear floor space com-
plying with 4.2.4 is provided to al-
low a person using a wheelchair to
make a forward approach, a parallel
approach, or both to the machine.
4.34.3 Reach Ranges.
(1) Forward Approach Only. If only a
forward approach is possible, operable
parts of all controls shall be placed within
the forward reach range specified in
4.2.5.
(2) Parallel Approach Only. If only a
parallel approach is possible, operable
parts of controls shall be placed as fol-
lows:
(a) Reach Depth Not More Than 10
inches (255 mm). Where the reach
depth to the operable parts of all con-
trols as measured from the vertical plane
perpendicular to the edge of the unob-
structed clear floor space at the farthest
protrusion of the automated teller ma-
chine or surround is not more than 10
inches (255 mm), the maximum height
above the finished floor or grade shall
be 54 inches (1370 mm).
ATM INSTALLATION FOR A CCESSIBILITY
16
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
(b) Reach Depth More Than 10 inches
(255 mm). Where the reach depth to
the operable parts of any control as mea-
sured from the vertical plane perpen-
dicular to the edge of the unobstructed
clear floor space at the farthest protru-
sion of the automated teller machine or
surround is more than 10 inches (255
mm), the maximum height above the fin-
ished floor or grade shall be as follows:
(3) Forward and Parallel Approach. If
both a forward and parallel approach
are possible, operable parts of controls
shall be placed within at least one of the
reach ranges in paragraphs (1) or (2) of
this section.
SNOITACIFICEPSYTILIBISSECCA
HTPEDHCAERTHGIEHMUMIXAM
sehcnI sretemilliM sehcnI sretemilliM
01552450731
110822/1350631
21503355431
310332/1255331
415532/1150131
51083155921
615042/1055821
71034050721
815542/1945521
9158
4945421
020152/1840321
125352/1745021
22065745911
325852/1640811
42016640711
EXCEPTION: Where a function can be
performed in a substantially equivalent
manner by using an alternate control,
only one of the controls needed to per-
form that function is required to comply
with this section. If the controls are iden-
tified by tactile markings, such markings
shall be provided on both controls.
4.34.4 Controls. Controls for user
activation shall comply with 4.27.4.
4.34.5 Equipment for Persons with
Vision Impairments. Instructions and
all information for use shall be made ac-
cessible to and independently usable
by persons with vision impairments.
(20) Where automated teller ma-
chines (ATMs) are provided, each ATM
shall comply with the requirements of
4.34 except where two or more are pro-
vided at a location, then only one must
comply.
EXCEPTION: Drive-up-only automated
teller machines are not required to com-
ply with 4.27.2, 4.27.3 and 4.34.3.
4.2.4* Clear Floor or Ground
Space for Wheelchairs.
4.2.4.1 Size and Approach. The mini-
mum clear floor or ground space re-
quired to accommodate a single, sta-
tionary wheelchair and occupant is 30
inches by 48 inches (760 mm by 1220
mm) (see Fig. 4a). The minimum clear
floor or ground space for wheelchairs
may be positioned for forward or paral-
lel approach to an object (see Fig. 4b
and 4c). Clear floor or ground space for
wheelchairs may be part of the knee
space required under some objects.
(4) Bins. Where bins are provided for
envelopes, waste paper, or other pur-
poses, at least one of each type pro-
vided shall comply with the applicable
reach ranges in paragraph (1), (2), or (3)
of this section.
17
4.2.4.2 Relationship of Maneuvering
Clearance to Wheelchair Spaces. One
full unobstructed side of the clear floor
or ground space for a wheelchair shall
adjoin or overlap an accessible route or
adjoin another wheelchair clear floor
space. If a clear floor space is located in
an alcove or otherwise confined on all
or part of three sides, additional maneu-
vering clearances shall be provided as
shown in Fig. 4(d) and 4(e).
4.2.4.3 Surfaces for Wheelchair
Spaces. Clear floor or ground spaces
for wheelchairs shall comply with 4.5.
4.2.5* Forward Reach. If the clear
floor space only allows forward ap-
proach to an object, the maximum high
forward reach allowed shall be 48 inches
(1220 mm) (see Fig. 5(a)). The minimum
low forward reach is 15 inches (380 mm).
If the high forward reach is over an ob-
struction, reach and clearances shall be
as shown in Fig. 5(b).
4.2.6* Side Reach. If the clear floor
space allows parallel approach by a per-
son in a wheelchair, the maximum high
side reach allowed shall be 54 inches
(1370 mm) and the low side reach shall
be no less than 9 inches (230 mm) above
the floor (Fig. 6(a) and 6(b)). If the side
reach is over an obstruction, the reach
and clearances shall be as shown in Fig
6(c).
Figure 4a. Clear floor space.
Figure 4b. Forward approach.
Figure 4c. Parallel approach.
ATM INSTALLATION FOR A CCESSIBILITY
18
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
For a front approach, where the depth
of the alcove is equal to or less than 24
inches (610 mm), the required clear floor
space is 30 inches by 48 inches (760 mm
by 1220 mm).
For a side approach, where the depth of
the alcove is equal to or less than 15
inches (380 mm), the required clear floor
space is 30 inches by 48 inches (760 mm
by 1220 mm).
Figures 4d. Clear Floor Space in
Alcoves.
For a front approach, if the depth of the
alcove is greater than 24 inches (610 mm),
then in addition to the 30-inch (760 mm)
width, a maneuvering clearance of 6
inches (150 mm) in width is required.
For a side approach, where the depth of
the alcove is greater than 15 inches (380
mm), then in addition to the 48-inch (1220
mm) length, an additional maneuvering
clearance of 12 inches (350 mm) is
required.
Figures 4e. Clear Floor Space in
Alcove.
19
Figure 6a. Parallel approach - side
reach.
Figure 6b. Parallel approach - high/
low side reach.
Figure 5a. Forward reach, unobstructed.
Figure 5b. Forward reach, obstructed.
ATM INSTALLATION FOR A CCESSIBILITY
20
Figure 6c. Side reach, obstructed.
Figure 7. ADA access dimensions for through-
the-wall ATM.
Ground exterior
Floor Interior
Rear Service Panel
aerAsseccApacidnaHedistuO
"84
)mm9121(
-ssorcA-
"03
)mm267(
-peeD-
*
derusaeM
foretnecmorf
lenaPlortnoC
*aicsaF
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60