ADTRAN MX408 Job Aid

Category
Gateways/controllers
Type
Job Aid
jobAid
1
DESCRIPTION
TheMX408ePseudowireGateway(MX408e)providesthe
requisiteinterfacesandswitchingbetweena10/100Ethernetor
GigEnetworkporttofourclient10/100Ethernetportsandeight
DSX1orE1TDMports.TheDSX1/E1portsarealleightDSX1
portsoralleightE1portsandcannotbe
mixedamongtheeight
ports.TheMX408eprovidespseudowireconnectionsbetweenthe
networkandclientDSX1/E1portsandEthernetswitching
betweenthenetworkandclient10/100Ethernetports.
NetworkportsconsistofanRJ4510/100Ethernetjackanda
SmallFormfactorPluggable(SFP)cageforaGigESFP
module.
Thefourclient10/100EthernetportsareequippedwithRJ45
jacks.TheeightDSX1orE1portsareRJ48Cjackssupporting
4wireDSX1sorE1s(TransmitTip,TransmitRing,ReceiveTip,
andReceiveRing).
TheMX408efrontpanel(refertothefigureabove)alsoprovides
a
moduleslotforfutureapplications.Intheeventthatamoduleis
notdeployedintheMX408e,ablankpanel(P/N1189699G1)is
installed.
Features
TheMX408ehasthefollowingfeatures:
GigEcopper/fiberSFPor10/100EthernetNetworkports
Fourclient10/100Ethernetports
EightclientDSX1orE1shorthaul,intrabuildingports
DB9craftport(RS232)
FrontpanelLEDs
Moduleslotforfutureapplications
Dual–48VDC(±24VDC)powerinputs
18rearpanelwirewrappostsforAlarmRelaysandAux
Inputs
SFPS
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
approvedbyADTRANwiththeMX408e.ADTRANcannot
certifysystemintegritywithotherSFPs . Toensureco mpatibility,
refertothedocumentationprovidedwitheachSFP.
MX408e
Pseudowire Gateway
TheMX408eisnotfactoryequippedwithSFPs.Recommended
SFPsarelistedinthefollowingtable.
ADTRAN P/N Description
1184561P1 1000BaseLX,1310nm,singlemode,2fiberoperation,
10kmmaximumopticaldistance
1184561PG1 1000BaseLX,1310nm,singlemode,2fiberoperation,
10kmmaximumopticaldistance
1184561P3 1000BaseSX,850nm,multimode,2fiberoperation,
500metermaximumopticaldistanceusing50μm
multimodefiber,300metermaximum
opticaldista nce
using62.5μmultimodefiber
1184561PG3 1000BaseSX,850nm,multimode,2fiberoperation,
500metermaximumopticaldistanceusing50μm
multimodefiber,300metermaximumopticaldista nce
using62.5μmultimodefiber
1184561P4 1000BaseT,copper,4wire,100meteroverCAT5UTP
cable
1184562P5 1000BaseZX,1550nm,
singlemode,2fiberoperation,
80kmmaximumopticaldistance
1184562PG5 1000BaseZX,1550nm,singlemode,2fiberoperation,
80kmmaximumopticaldistance
1442110G1 1000BaseLX,1490nmtransmitter,1310nmreceiver,
singlefiberoperation,10kmmaximumopticaldis
tance
1442110G2 1000BaseLX,1310nmtransmitter,1490nmreceiver,
singlefiberoperation,
10kmmaximumopticaldis
tance
1442120G1 1000BaseLX,1490nmtransmitter,1310nmreciever,
singlefiberoperation,20kmmaximumopticaldis
tance
1442120G2 1000BaseLX,1310nmtransmitter,1490nmreciever,
singlefiberoperation,20kmmaximumopticaldis
tance
1442140G1 1000BaseLX,1490nmtransmitter,1310nmreciever,
singlefiberoperation,40
kmmaximumopticaldis
tance
1442140G2 1000BaseLX,1310nmtransmitter,1490nmreciever,
singlefiberoperation,40kmmaximumopticaldis
tance
1442320G1 1000BaseLX,1310nm,singlemode,2fiberoperation,
20kmmaximumopticaldistance
1442340G1 1000BaseLX,1310nm,singlemode,2fiberoperation,
40kmmaximumopticaldistance
CLEI: COM7V00E_ _
Product P/N: 1189608G1
Issue Date: August 2015
Document P/N: 61189608G1-22D
ACT ALM
ACO
MODULE
1234 56781234
CRAFT
10/100
MODULE
GE
DSX-1/E1
MX408e
1189608G1
10/100
NETWORK
2 61189608G1-22D
6. ConnecttheCRIT(critical),MAJOR,andMINORalarmleads
fromthefuseandalarmpaneltotheCommon(C),Normally
Open(NO),andNormallyClosed(NC)wirewrapterminals
ontheMX408erearpanelasrequired.
7. Connecttheauxiliaryinputs,labeled
AUX INPUTS,as
required.TheMX408eauxiliaryinputsconnectasfollows:
AUXINPUTterminals1and2connecttoAlarm1
AUXINPUTterminals3and4connecttoAlarm2
AUXINPUTterminals5and6connecttoAlarm3
AUXINPUTterminals7and8connecttoAlarm4
AUXINPUTterminal9isnotconnected
FRONT PANEL LEDS
Label Status Description
NETWORK
(GE & 10/100)
Off
Green
Yellow
Nolink
Linkisup
TransmitorReceiveactivity
10/100
(Clients 1 - 4)
Off
Green
Yellow
Nolink
Linkisup
TransmitorReceiveactivity
DSX-1/E1
(1 - 8)
2
2
2
Off
Green
Yellow
Flashing
Yellow
Red
FlashingRed
FlashingRed
(1second)
Portisdisabled
Portisenabledandinnormal
operation
Locallyoriginatedtestinprogress
Remotelyoriginatedtestinprog
ress
NoncriticalDSX1/E1defectin
progress(forexample,AIS,RAI)
CriticalDSX1/E1defect
(noncriticalsystemdefect;for
example,
LOS,LOF)
Singlecodeviolationorburstof
codeviolationsjustoccurred
ACT
/
/
2
Green
Green/Yellow
(alternating)
Yellow
Red/Yellow
(alternating)
Red
FlashingRed
Normaloperation
Normaloperationandconsole
open
Softwareupdateinprogress
Selftestfailedandconsoleopen
Selftestfailed
Cardhasfailed
ALM
2
2
Green
Yellow
Flashing
Yellow
Red
FlashingRed
Nocritical,major,orminoralarms
Activeacknowledgednoncritical
alarm
Activeacknowledgedcritical
alarm
Majororminoralarminprogress
Criticalalarminprogress
MODULE
2
Off
Green
Red
FlashingRed
Modulenotinstalled
Modulenormaloperation
Modulealarm
Modulefailed
INSTALLATION
Afterunpackingtheunit,inspectitfordamage.Ifdamageis
noted,fileaclaimwiththecarrierandthencontactADTRAN.For
moreinformation,refertothewarranty.
Followthestepslistedbelowtowallmountorrackmount
theMX408e.
1. AttachmountingbracketstothesideoftheMX408einthe
correctorientation
foreitherrackmountorwallmountusing
thetwoscrewsprovidedforeachbracket.
WARNING
!
Donotupsetthestabilityoftheequipmentrackafterinstallation
iscomplete.
2. SecuretheMX408etotherackorwall.
ForRackmount:SecuretheMX408etotheequipment
rackwiththeappropriatescrews.
ForWallmount:Preparethemountingsurfaceby
attachingaboard(typicallyplywood,3/4”to1”thick)to
awallstudusingappropriatelagbolts.Securethe
MX408etotheplywoodusingtwo3/32”to1/8”wood
screwsatleast1”inlength.
3. Connecttheframegroundfromtheframegroundlug
onthe
upperrightrearpaneloftheMX408etotheequipmentrack
groundingscreworotherappropriategrounding
connection.
4. MakepowerconnectionstotheMX408e.
NOTE
Areadilyaccessibledisconnectde vice,suchasarackmount
fuseandalarmpanel thatissuitablyapprovedandrated,
shouldbeincorporatedintothefixedwiring.
Con necttoareliablygrounded–48VDCor±24VDCsource
whichiselectricallyisolatedfromtheACsource.
Thebranchcircuitovercurrentprot ectio nshouldbea2amp,
slowblowfuseorcircuitbreaker.
a. Determinewhichfusepairsaretosupplypowertothe
MX408e.
b. RemovethefusesfromtheAandBslotsforthepair.
c. Connect
RETA,PWR A,RETB,andPWRB tothepow e r
connector.
PWR referstorespective–48VDCor±24VDC
powersources,while
RET referstorespectivereturns.
5. Checkvoltagesandapplypower.
a. Usingavoltmeter,verifythattheoperatingvoltageis
withinthespecificationsforAorBpowerfeeds.For
moreinformation,refertotheSpecifications.
WARNING
!
Installingfusesinthefuseandalarmpanelatthisstageprovides
powertotheMX408epinsandconnectorsontherearpaneland
insidetheMX408e.Exercisecautiontoavoidelectricalshock.
b. Installappropriatefuses(2amp,slowblow)intheslots
inthefuseandalarmpanelthatservicestheMX408e.
61189608G1-22D 3
FRONT PANEL PUSHBUTTON
CONNECT AND LOGIN TO SYSTEM
ConnecttothefrontpanelRS232,DB9connectorlabeledCRAFT
tologonandprovisiontheMX408ebywayofVT100terminalor
VT100terminalemulationsoftwaresuchasHyperTerminalor
ProCommPlus.
CRAFTportdefaultsareasfollows:
DataRate:Auto(upto115.2kbps)
AsynchronousDataFormat:8databits,noparity,1stopbit,
andnoflowcontrol
Press
ENTERtoactivatetheCLI.
TheMX408ecanalsobeaccessedviaTelnetthroughanEthernet
interface.
10/100port(Ethernet)defaultsareasfollows:
IPAddress:192.168.100.1
SubnetMask:255.255.0.0
DefaultGateway:192.168.1.1
NOTE
Thedefault usernameandpassword are “A D M I N and
“PASSWORD”inallcapitalletters.
MAINTENANCE
TheMX408edoesnotrequireroutinehardwaremaintenancefor
normaloperation.ADTRANdoesnotrecommendthatrepairsbe
attemptedinthefield.Repairservicesmaybeobtainedby
returningthedefectiveunittoADTRAN.Refertothewarranty
forfurtherinformation.Fieldsupportforsoftwareisprovided
throughupgradefacilities.
Label Description
ACO
ThefrontpanelACO(AlarmCutOff)switchdisablesthe
alarmindications.
SPECIFICATIONS
SpecificationsfortheMX408eareasfollows:
Electrical
MaximumInputCurrent:
1amp@24VDC
500mA@48VDC
OperatingVoltageRange:
–48VDCsystems:–42VDCto–56.7VDC
±24VDCsystems:±20VDCto±27VDC
MaximumHeatDissipation:24watts
Physical
Height:1.75inches
Width:17.25inches
Depth:8.5inches
Weight:5lbs,7oz
Environmental
OperatingTemperatureRange:–40°Cto+65°C
StorageTemperatureRange:–40°Cto+85°C
RelativeHumidity:95%noncondensing
SAFETY AND REGULATORY COMPLIANCE
RefertotheMX408ePseudowireGatewaySafetyandRegulatory
ComplianceNotice(P/N61189608G117)fordetailedsafetyand
regulatoryinformation.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can be
found online at www.adtran.com/warranty
.
©2015 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61189608G1-22D*
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

ADTRAN MX408 Job Aid

Category
Gateways/controllers
Type
Job Aid

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI