NEC Express5800/320La Upgrade Guide

Category
KVM switches
Type
Upgrade Guide
320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
Page
Page Page
Page 1
11
1 of
of of
of 6
66
6
Express5800/320La Software Notes
Windows 2000 Service Pack 4
Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
Page
Page Page
Page 2
22
2 of
of of
of 6
66
6
Proprietary Notice and Liability Disclaimer
The information disclosed in this document, including all designs and related materials, is
the valuable property of NEC Solutions (America), Inc. and/or its licensors. NEC
Solutions (America), Inc. and/or its licensors, as appropriate, reserve all patent, copyright
and other proprietary rights to this document, including all design, manufacturing,
reproduction, use, and sales rights thereto, except to the extent said rights are expressly
granted to others.
The NEC Solutions (America), Inc. product(s) discussed in this document are warranted
in accordance with the terms of the Warranty Statement accompanying each product.
However, actual performance of each product is dependent upon factors such as system
configuration, customer data, and operator control. Since implementation by customers of
each product may vary, the suitability of specific product configurations and applications
must be determined by the customer and is not warranted by NEC Solutions (America),
Inc.
To allow for design and specification improvements, the information in this document is
subject to change at any time, without notice. Reproduction of this document or portions
thereof without prior written approval of NEC Solutions (America), Inc. is prohibited.
Trademarks
Microsoft, Windows, and Windows 2000 are registered trademarks of Microsoft
Corporation.
VERITAS Volume Manager is a trademark of VERITAS Software Corporation.
All other trademarks and registered trademarks are the property of their respective
trademark owners.
PN: 455-01709-001 February 2004
Copyright 2004
NEC Solutions (America), Inc
10850 Gold Center Drive, Suite 200,
Rancho Cordova, CA 95670
All Rights Reserved
320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
Page
Page Page
Page 3
33
3 of
of of
of 6
66
6
Windows 2000 Service Pack 4 Upgrade Procedure for 320La
Prerequisites for Upgrade
A. FT Control Software Version 1.3 or higher is installed.
B. Back up the system boot disks prior to performing this upgrade in the event of
the rare occurrence that the OS fails to start during or after the upgrade.
C. The 363-01668-000 320La Windows 2000 Service Pack 4 Upgrade CD.
NOTE: This CD does not include the Microsoft Windows 2000 Service Pack
4 release.
D. A Microsoft Windows 2000 Service Pack 4 CD (not included in this kit).
E. The 455-01709-000 Windows 2000 Service Pack 4 Upgrade Procedure for
320La (this document).
F. The 363-01597-004 EXPRESSBUILDER Version 2.002b-Gb CD.
G. The Veritas Volume Manager Version 3.1 License Key.
H. Document the Network (LAN) teaming configuration in the Intel PROSet II
utility so that they can be restored after the upgrade, if necessary.
I. Document the disk mirroring configuration so that it can be restored after the
upgrade, if necessary.
J. Review the documentation below.
Cautions and Restrictions
a. The 320La may appear to hang with a blank screen when shutting down prior
to a restart. This behavior has typically been noted when a USB to PS2
converter is used for the mouse and/or keyboard, with or without a KVM
switch. As a workaround for this situation, remove and replace the
keyboard/mouse USB cable in the USB port. System operation should
continue after the cable is removed.
b. The VERITAS Volume Manager Hot Relocation and Hot Spare functions,
which are installed by default, are not supported on the NEC Express5800/ft
series.
c. Do not read or write data on the system during the upgrade process.
d. During the update process, the screen may flicker for a couple of seconds.
This is normal.
e. The procedures documented in these instructions refer to the CD-ROM drive
as <CD>. Substitute the actual drive letter of your CD-ROM drive wherever
<CD> is referenced in this document.
f. After each system restart the server MUST be in full duplex mode before
proceeding to the next step. NOTE: It may take several minutes to complete
the synchronization.
320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
Page
Page Page
Page 4
44
4 of
of of
of 6
66
6
Windows 2000 Service Pack 4 Upgrade Procedure
1. Confirm that the installed FT Control Software version is version 1.3 or
higher. From Windows Explorer, run FTVERCHK.EXE from the
\FTSVTOOL\VERSION directory of 363-01597-004 EXPRESSBUILDER
Version 2.002b-Gb CD. The installed version is displayed. If the version
displayed is not 1.3 or higher, perform the FT Control Software Upgrade
Procedure (see Page 5) before continuing with the Windows 2000 Service
Pack 4 Upgrade Procedure.
2. Apply Windows 2000 Hot Fix W2K03002.
a. Logon as Administrator.
b. Insert the 363-01668-000 320La Windows 2000 Service Pack 4 Upgrade
CD into the CD-ROM drive.
c. Copy the directory W2K03002 from the CD to C:\.
NOTE: The W2K03002 directory may be removed from C:\ upon
completion of the application of Windows 2000 Hot Fix W2K03002.
d. Select Start->Run C:\W2K03002\update.exe.
e. Follow the prompts on the screen until the Hot Fix installation is
completed.
3. Remove any installed Veritas Volume Manager 2.7 Hot Fixes using the
Control Panel Add/Remove Programs applet. Follow the prompts on the
screen to remove the Hot Fix, including restarting the system when prompted.
NOTE: If multiple hot fixes are installed, the hot fixes should be removed in
descending order (i.e. remove HotFix07 before HotFix06).
4. Remove Veritas Volume Manager Version 2.7 using the Control Panel
Add/Remove Programs applet. Follow the prompts on the screen to remove
Veritas Volume Manager Version 2.7, including rebooting the server as
necessary when prompted.
5. Install Veritas Volume Manager Version 3.1.
a. Logon as Administrator.
b. Insert the 363-01668-000 320La Windows 2000 Service Pack 4 Upgrade
CD into the CD-ROM drive.
c. Select Start->Run <CD>\VXVM31\launch.exe.
d. Follow the prompts on the screen until the Veritas Volume Manager
Version 3.1 installation is completed, including rebooting the server when
prompted. The installation Setup Type is Server. NOTE: The Veritas
Volume Manager Version 3.1 License Key will be required during this
process.
320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
Page
Page Page
Page 5
55
5 of
of of
of 6
66
6
6. Install Veritas Volume Manager Version 3.1 Service Pack 1.
a. Logon as Administrator.
b. Insert the 363-01668-000 320La Windows 2000 Service Pack 4 Upgrade
CD into the CD-ROM drive.
c. Select Start->Run <CD>\VXVM31SP1\VXVM\VMW2K31SP01a.msi.
d. Follow the prompts on the screen until the Veritas Volume Manager
Version 3.1 Service Pack 1 installation is completed.
e. Reboot the server as prompted.
7. Install Windows 2000 Service Pack 4 following the instructions provided with
your Service Pack 4 distribution.
8. Apply Windows 2000 Hot Fix W2K03005.
a. Logon as Administrator.
b. Insert the 363-01668-000 320La Windows 2000 Service Pack 4 Upgrade
CD into the CD-ROM drive.
c. Open a command prompt window.
d. Change directory to the root directory of the CD.
e. Run update.bat.
f. Follow the prompts on the screen until the Hot Fix installation is
completed.
9. The 320La Windows 2000 Service Pack 4 Upgrade Procedure is complete.
FT Control Software Version 1.3 Upgrade Procedure
An FT Control Software Version 1.3 upgrade is available on the 363-01597-004
EXPRESSBUILDER Version 2.002b-Gb CD. To install the update:
1. Login as administrator.
2. Insert the EXPRESSBUILDER Version 2.002b-G CD into your CD-ROM
drive. The CD auto-runs to the main menu.
3. At the EXPRESSBUILDER Master Control Menu, click Setup.
4. On the fly-out menu, select “Update NEC Express5800 system.”
5. When prompted to apply Service Pack 3, click “Cancel” so that only the NEC
modules are installed (Service Pack 3 is not installed).
6. Click OK at the Setup Message “The system is being updated” dialog box.
7. Another dialog box displays, click OK. Respond “Yes” to any prompts to
replace files, including overwriting newer files.
8. NEC drivers and software modules are installed.
9. At the completion of the update process, the system will reboot. Remove the
EXPRESSBUILDER CD while Windows is shutting down.
10. After the Reboot, the Found New Hardware wizard may run. If it does, click
on all defaults to complete the process. If prompted to restart Windows, DO
NOT RESTART the system.
11. Check disk mirroring, if disabled, enable it again. During disk
resynchronization, DO NOT shut down the system.
a. Launch Veritas Volume Manager
b. Check if Disk Mirroring is enabled, if not re-enable mirroring, recreating
as necessary (follow FTNOTES Step 2, if needed).
320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure320La Windows 2000 Service Pack 4 Upgrade Procedure
320La Windows 2000 Service Pack 4 Upgrade Procedure
Page
Page Page
Page 6
66
6 of
of of
of 6
66
6
12. Start the Windows 2000 Device Manager, and select View>Device by
Connection.
a. Uninstall the “Stratus Enclosure Services NEC GEM Processor ” device.
b. Uninstall the “Stratus Fault Tolerant Virtual 69000 video “ device.
c. Uninstall the “Stratus Virtual Host Bus Adapter Device” entry, which has
no sub-tree.
13. Reboot your system.
14. Insert the EXPRESSBUILDER CD and install/update the ESMPRO Agent
from the EXPRESSBUILDER Master Control Menu.
15. Reboot your system.
16. Check the teaming configuration on your network cards using PROSET and
restore if needed (follow FTNOTES Step 1).
17. Install the NEC ESMPRO report service for Volume Manager from the
EXPRESSBUILDER Master Control Menu.
18. The system update to FT Control Software Version 1.3 has been completed.
19. If your system has any options installed, run the appropriate batch file
associated with that option. See the following table.
Options Batch File
NU515 / Pro 100+ NIC CD\WINNT\W2K\N850475.BAT
062-02021-000 / QLA12160 HBA CD\WINNT\W2K\N8803001.BAT
NU516 / QLA1080 HBA CD\WINNT\W2K\N8803002.BAT
062-02020-000 / FT DEU 2X13 HDD D\WINNT\W2K\N8890001.BAT
062-02173-000 / S1200 HOST HBA PKG CD\WINNT\W2K\N8803030.BAT
NU570/N570-P/NU571/NU571-P Pro1000
Copper / Fiber
CD\WINNT\W2K\N810484.BAT
Note: Shutdown and Restart your system after
running batch files.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

NEC Express5800/320La Upgrade Guide

Category
KVM switches
Type
Upgrade Guide

Ask a question and I''ll find the answer in the document