Electric Winches

Porter Electric Winches Operating instructions

  • Hello! I've reviewed the mounting instructions for the Porter FITG712WMC electric winch provided and I'm ready to help. The document details how to install the winch on concrete masonry walls, emphasizing safety measures like proper cable feed and the necessary anchor types. It also includes mounting height requirements and critical architect notes. Ask me anything about its installation or specifications.
  • What is the minimum height above the finished floor for mounting the winch?
    What is the minimum cable travel required?
    How many anchors are required for mounting a concrete masonry wall?
12 1/2"
5 1/2"
26"
1 1
2
"
4 1
4
"
24"
R
9
32
"
A
A
CABLE
DRUM
2x6 WOOD PAD
2x6 WOOD PAD
MOUNTING
HARDWARE,
BY OTHERS
1 1
2
"
20.0°
MAX.
SECTION A-A
CABLE TRAVEL
WARNING: CABLE FEED
MUST NEVER BE
PERPENDICULAR TO WALL!
712 WINCH
EXISTING
CMU WALL
SPACER
TUBS00656
12'-0"
MIN.
ABOVE
FINISHED
FLOOR
NOTES:
1 HP WINCH SHOULD NOT BE WALL-MOUNTED.
WALL DESCRIPTION, INCLUDING MATERIALS, THICKNESS, AND ASSEMBLY (IF APPLICABLE) SHALL BE INCLUDED IN FIELD
CHECK.
INSTALLER TO DRILL HOLES FOR 1/2" DIA. MOUNTING HARDWARE IN WOOD PADS. HOLE LOCATIONS MAY VARY PER
APPLICATION. CONSULT WITH ARCHITECT OR ENGINEER BEFORE DRILLING HOLES.
ARCHITECT NOTE:
ELECTRIC WINCH MAY BE LOCATED ABOVE OR BELOW PULLEY LOCATION, WITH A MINIMUM OF 3'-0" CABLE TRAVEL TO
ENSURE PROPER CABLE WRAP ON WINCH DRUM. WINCH MAY ALSO BE MOUNTED TO OVERHEAD STRUCTURE (MUST BE
INDICATED ON FIELD CHECK).
WHEN LOCATING ELECTRIC WINCH ON WALL, CHECK TO ENSURE WINCH WILL NOT INERFERE WITH THE MODEL 219 CROSS
FLATS ON BACKSTOP WHEN BACKSTOP IS FOLDED UP.
LOCATE CENTER OF WINCH DRUM AT LEAST 12'-0" ABOVE FINISHED FLOOR ELEVATION.
CONFIRM WALL IS SUFFICIENTLY BRACEDAND REINFORCED TO SUPPORT OPERATING WINCH. DESIGN EACH ANCHORS
FOR AT LEAST 600 LBS SHEAR COMBINED WITH 210 LBS TENSION.
FOR MOUNTING TO CMU WALLS, ANCHOR TO WALL WITH AT LEAST (8) 1/2" DIA. MASONRY ANCHORS, IN FULLY GROUTED
CELLS. THERE SHOULD BE ONLY ONE ANCHOR PER CELL. REFER TO ANCHOR MANUFACTURER TO DETERMINE
ANCHORAGE DESIGN AND DETAILS. AS NECESSARY, CONSULT WITH STRUCTURAL ENGINEER TO CONFIRM ANCHOR AND
WALL DESIGNS ARE ADEQUATE.
ELECTRICIAN NOTE:
MOUNT 4" SQUARE JUNCTION BOX WITHIN 3'-0" OF ELECTRIC WINCH FOR NEMA L14-20 4 POLE TWIST-LOCK RECEPTACLE.
C
L
OF PULLEY
WOOD PADS ARE AVAILABLE IN 2'-0", 4'-0", AND 5'-0" LENGTHS.
2'-0" PADS, AS SHOWN, STANDARD. CONTACT PORTER DEALER OR SALES
REPRESENTATIVE FOR OTHER OPTIONS.
FITG712WMC:
PARTS PROVIDED
Quantity
Part Number
Description
2
XPAD2060200B
WOOD PAD- 2X6 X 2FT-0IN
2
TUBS00656
1 1/2 X 3/4 X 14G; 8" LG
REQUIRED PARTS - BY OTHERS
Quantity
Description
8
WALL ANCHORS
www.porterathletic.com
Copyright
2017 by Porter Athletic.
All rights reserved.
888-277-7778
6/9/2017
INST00712055
Page 1 of 2
3/4 HP ELECTRIC WINCH
CONCRETE MASONRY WALL MOUNTING INSTRUCTIONS
18"
4 1
4
"
30"
R
9
32
"
5 1
2
"
12 1
2
"
MOUNTING
HARDWARE,
BY OTHERS
ELECTRIC WINCH
2x10 (SHOWN)
OR 2x8 WOOD PAD
CONSULT ARCHITECT
OR ENGINEER FOR
ANCHOR SELECTION
AND PLACEMENT
20.0°
MAX.
BLOCKING, BY OTHERS
EXISTING STUD WALL
SPACER
TUBS00656
12'-0"
MIN.
ABOVE
FINISHED
FLOOR
NOTES:
1 HP WINCH SHOULD NOT BE WALL-MOUNTED.
WALL DESCRIPTION, INCLUDING MATERIALS, THICKNESS, AND ASSEMBLY (IF APPLICABLE) SHALL BE INCLUDED IN
FIELD CHECK.
INSTALLER TO DRILL HOLES FOR 1/2" DIA. MOUNTING HARDWARE IN WOOD PADS. HOLE LOCATIONS MAY VARY PER
APPLICATION. CONSULT WITH ARCHITECT OR ENGINEER BEFORE DRILLING HOLES.
ARCHITECT NOTE:
ELECTRIC WINCH MAY BE LOCATED ABOVE OR BELOW PULLEY LOCATION, WITH A MINIMUM OF 3'-0" CABLE TRAVEL TO
ENSURE PROPER CABLE WRAP ON WINCH DRUM. WINCH MAY ALSO BE MOUNTED TO OVERHEAD STRUCTURE (MUST
BE INDICATED ON FIELD CHECK).
WHEN LOCATING ELECTRIC WINCH ON WALL, CHECK TO ENSURE WINCH WILL NOT INERFERE WITH THE MODEL 219
CROSS FLATS ON BACKSTOP WHEN BACKSTOP IS FOLDED UP.
LOCATE CENTER OF WINCH DRUM AT LEAST 12'-0" ABOVE FINISHED FLOOR ELEVATION.
CONFIRM WALL IS SUFFICIENTLY BRACEDAND REINFORCED TO SUPPORT OPERATING WINCH. DESIGN EACH
ANCHORS FOR AT LEAST 600 LBS SHEAR COMBINED WITH 210 LBS TENSION.
FOR MOUNTING TO STUD WALLS, PROVIDE BLOCKING AS REQUIRED AND USE AT LEAST (8) POSITIVE FASTENER
CONNECTIONS TO THE WALL STUDS OR BLOCKING. WOOD PADS PROVIDED ARE NOT TO BE CONSIDERED BLOCKING
OR BRACING. AS NECESSARY, CONSULT WITH STRUCTURAL ENGINEER TO CONFIRM BLOCKING AND CONNECTIONS
ARE ADEQUATE.
ELECTRICIAN NOTE:
MOUNT 4" SQUARE JUNCTION BOX WITHIN 3'-0" OF ELECTRIC WINCH FOR NEMA L14-20 4 POLE TWIST-LOCK RECEPTACLE.
C
L
OF PULLEY
2x10x30" WOOD PAD STANDARD. 2x8 WOOD PADS IN 4'-0" OR 5'-0"
LENGTHS AVAILABLE. CONTACT PORTER DEALER OR SALES
REPRESENTATIVE FOR OTHER OPTIONS.
CABLE TRAVEL
WARNING: CABLE FEED
MUST NEVER BE
PERPENDICULAR TO WALL!
FITG712WMS:
PARTS PROVIDED
Quantity
Part Number
Description
1
XPAD2100260B
WOOD PAD; 2X10 X 2FT-6IN
2
TUBS00656
1 1/2 X 3/4 X 14G; 8" LG
REQUIRED PARTS - BY OTHERS
Quantity
Description
8
WALL ANCHORS
www.porterathletic.com
Copyright
2017 by Porter Athletic.
All rights reserved.
888-277-7778
6/9/2017
INST00712055
Page 2 of 2
3/4 HP ELECTRIC WINCH
STUD WALL MOUNTING INSTRUCTIONS
/