FläktGroup CPT Installation guide

Type
Installation guide
INSTALLATION, OPERATION, MAINTENANCE, ADJUSTMENT AND SPARE PARTS
COOKER HOOD
CPT
Cooker hood CPT - Technical manual
2
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CONTENTS
NOTE! INSTALLATION, ADJUSTMENT AND COMMISSIONING AS DESCRIBED
IN THESE INSTRUCTIONS MUST BE CARRIED OUT BY AN INSTALLER OR SERVICE PERSONNEL.
OPERATION AND MAINTENANCE (FOR USER)
Operation - touch panel functions .................................................................................................................................. 3
Maintenance - cleaning ...................................................................................................................................................... 4
INSTALLATION (FOR INSTALLER AND SERVICE PERSONNEL)
CPTG - Installation options ................................................................................................................................................5
CPTG - Electrical connection examples .......................................................................................................................6
CPTG - Fan speed setting ...................................................................................................................................................7
CPTJ - Installation and electrical connection .............................................................................................................8
CPTR - Installation and electrical connection ............................................................................................................9
ADJUSTMENT, COMMISSIONING (FOR INSTALLER AND SERVICE PERSONNEL)
CPTG, CPTR with basic flow - airflow adjustment, basic and forced ventilation ......................................10
CPTJ, CPTR without basic flow - airflow adjustment,
forced ventilation ..................................................................................................................................................................11
MISCELLANEOUS
Spare parts ............................................................................................................................................................................ 12
EC Declaration of Conformity .......................................................................................................................................... 13
Disposal of products and packaging materials .......................................................................................................14
WARNING! THE APPLIANCE MAY BE USED BY CHILDREN OVER THE AGE OF 8, PERSONS (INCLUDING CHILDREN) WITH PHYSICAL,
SENSORY OR MENTAL DISABILITIES OR LACK OF KNOWLEDGE OR EXPERIENCE, PROVIDED THEY HAVE RECEIVED INSTRUCTION
OR INFORMATION ON SAFE USE OF THE APPLIANCE AND UNDERSTAND THE POTENTIAL RISKS. CHILDREN MAY NOT PLAY WITH
THE APPLIANCE. CHILDREN MAY NOT CLEAN OR PERFORM MAINTENANCE ON THE APPLIANCE WITHOUT SUPERVISION.
Cooker hood CPT - Technical manual
3
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
OPERATION - TOUCH PANEL FUNCTIONS
CPTG
WORKING LIGHT
Turn on and off the light with a short pressure.
Hold on the MINUS (-) symbol for dimming until
you’ve got the light you wish.
The light will always start with full brightness.
FILTER MONITOR
This fan cover is equipped with filter monitor to
ensure cleaning the grease filters.
After 30 hours operation the display switching
between “F” and “1” which means that the filters must be
cleaned. To reset the fan, hold on the ON/OFF symbol for 5 sek when
the fan is off.
FAN CONTROL
The motorized damper will be open with a
pressure on the ON/OFF symbol, as the same
time, the backlight is activated.
With a pressure on the MINUS (-) or PLUS (-)
symbol you can select speed. This hood can control the cen-
tral fan on three different speed with the following functions:
Speed 1 - Open damper. Ground flow on central fan.
Speed 2 - Open damper. Center position on central fan.
Speed 3 - Open damper. Forced mode on central fan.
The motorized damper will be closed automatically after 60 minutes
and the central fan returns to ground flow. You can always go back to
ground flow when you pressure the ON/OFF symbol.
ON/OFF LIGHTNING MINUS (–) DISPLAY PLUS (+) TIMER
Cooker hood CPT - Technical manual
4
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
OPERATION - TOUCH PANEL FUNCTIONS
CPTJ, CPTR
LIGHTNING DAMPER FILTER MONITOR
WORKING LIGHT
Turn on and off the light with a short pressure, the sign
for lamp is lighten. Hold on the Lightning symbol for dim-
ming. Release the button when you’ve satisfied with the
brightness. The light will always start with full brightness.
DAMPER
The motorized damper opens with a pressure on the
damper symbol and the damper light will be lighten up.
The damper will automatically be closed after 60 min-
utes to return to the base flow.
FILTER MONITOR
This fan cover with filter monitor is to ensure the clean-
ing of the filter monitor. After 30 hours of active operating
mode (open damper) the damper light will flash which
means that the filter will be cleaning. When the filter has
been cleaned , hold on the symbol for filter monitor in 5 sek when the
damper is closed to reset.
Cooker hood CPT - Technical manual
5
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
Reset approx.
5 seconds.
After cleaning the grease filters, reset the alarm. Depress the boost
damper button for about 5 seconds.
MAINTENANCE
A light on the panel indicates when the grease filters need cleaning.
To remove the grease filters from the cooker hood, press in-
wards, then pull down and finally pull outwards.
Do not use the cooker hood without the grease filters fitted.
1
2
33
Wash the grease filters by hand or in a dishwasher.
2
3
1
4
15 30 60
Cooker hood CPT - Technical manual
6
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTG - INSTALLATION
Ø50
176
115
33
96
min 500 mm
160
2
3
1
1 2 3
153060
JBDD
All cooker hoods must be connected directly or indirectly via the heat recovery unit/extract air fan to earth.
1
2
3
Fixed installation, see connection examples on page 6.
1 2 3
153060
1 = Orange – Supply
voltage
to fan
2 = Blue – Zero
3 = Black – Phase
4 = Yellow/Green – Earth
600 mm
2
3
1 2 3
153060
1
INSTALLATION UNDER KITCHEN CABINET
FOR CONNECTION TO EXTRACT AIR FAN JBDD, GENERATION 2
INSTALLATION BETWEEN KITCHEN CABINETS
FOR CONNECTION TO OTHER FANS
Cooker hood CPT - Technical manual
7
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTG - ELECTRICAL CONNECTION EXAMPLES
CPTG has an integrated transformer, max. 150 VA. NOTE! Installation must be carried out by a qualified electrician.
SPICE RACK FAN JBDB SPICE RACK FAN JBDC
ROOF FAN JBFG HEAT RECOVERY UNIT RDAA
1)
Also for replacement
kit JBDB-99-05-0 JBDB
1)
CPDG/CPTG
N
L
Blue
Blue White
Black
Black
Orange
JBDA-99-031
2µF, not included
Power supply
230V
Yellow / Green
Yellow / Green
JBFG
CPDG/CPTG
Power supply
230V
N
L
Blue
Brown
Black
Yellow /Green
Blue
Yellow /Green
Orange
1)
Also for replacement
kit JBDB-99-05-0 JBDC
1)
CPDG/CPTG
N
L
JBDA-99-031
2µF, not included
Power supply
230V
Brown
Black
Blue
Blue
Orange
Yellow / Green
Yellow / Green
RDAA
CPDG/CPTG
Power supply
230V
N
2 4 5 6 731
L
Orange
Black
Blue
Yellow / Green
Cooker hood CPT - Technical manual
8
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTG - FAN SPEED SETTING
It is recommended that these steps be carried out
before installing the cooker hood under/between
kitchen cabinets.
How to access the transformer and the coupling adapter:
1. Remove the grease filters.
2. Unscrew the two screws on the coupling plate at the front of the
cooker hood.
1
2
3
4
5
6
7
8
9
1
2
3
4
5
White (Trickle)
Blue
Blue
Transformer
Purple
Orange
Yellow
White
Green
Red
Black
Brown
Coupling adapter, removable
Grey (Normal speed)
Black (High speed)
Brown
N
75
123456789
90
105
120
130
150
170
230
3. Gently fold the plate down as shown in the diagram to the right.
4. Remove the detachable coupling adapter from the control card and
the transformer cable by pulling the connector apart.
Low speed, normal speed and high speed can be changed by moving
the relevant cables on the connector.
Note that the blue and brown cables must not be moved.
5. Move the cables on the connector to obtain the desired fan speed.
1 1
2 2
Cooker hood CPT - Technical manual
9
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTJ - INSTALLATION AND ELECTRICAL CONNECTION
1 2
3
2
1
RDKS
4
5
4.1 4.2
2
1
1 2 3
153060
The picture shows an RDKS unit with a right-hand configuration.
If the supply cord is damaged, it must be replaced by the manufacturer,
the distributor or a similarly qualified professional capable of performing the job safely.
THE RDKS UNIT MUST BE CONNECTED TO AN EARTHED POWER OUTLET
Cooker hood CPT - Technical manual
10
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTR - INSTALLATION AND ELECTRICAL CONNECTION
All cooker hoods must be connected directly to earth.
600 mm
2
3
1 2 3
153060
1
INSTALLATION UNDER KITCHEN CABINET INSTALLATION BETWEEN KITCHEN CABINETS
FOR CONNECTION TO ILOX AND RDAS HEAT RECOVERY UNITS
WITH A 5th MOUNTING RING
The product comes factory-fitted with a boost damper without basic
flow. Do not use the damper with basic flow that is supplied with the
product.
In order for forced airflow to be activated automatically when the
damper is opened, a cable must be connected between the CPTR and
the air heating unit.
FOR CONNECTION TO CENTRAL AIR EXTRACTION SYSTEM IN
APARTMENT BUILDINGS
In this case, the boost damper must be replaced.
The product comes ready-fitted with a damper without basic flow, but
the supplied damper with basic flow must be used instead.
Blue
CPTR Junction box
Control card
Curo
Brown 37
38
Cooker hood CPT - Technical manual
11
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTG, CPTR WITH BASIC FLOW - ADJUSTMENT
NOTE! Boost mode 11 is max.
7,5 10 12,5 15 20 25
250
200
100
50
40
30 510 20 30
30
30+1 plug
30+4 plug
(4C)
30+2 plug
(2C)
Airflow q, l/s
Measurement pressure
p, Pa
BASIC VENTILATION
FORCED VENTILATION
NOTE! The unit must be operated with forced air
flow while the cooker hood is being adjusted.
10
20
30
40
50
100
200
150
20 30 40 50 80
Airflow q, l/s
Measurement pressure
p, Pa
b = 5
a = 25 10
10
1015 15 15
25 25
25
7 9
11
p
b
a
Cooker hood CPT - Technical manual
12
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
CPTJ, CPTR WITHOUT BASIC FLOW - ADJUSTMENT
b
10
20
30
40
50
100
200
150
20 30 40 50 80
b = 7 8 9 11
Airflow q, l/s
Measurement pressure
p, Pa
FORCED VENTILATION
Damper blades without basic flow (dense blades)
NOTE! Boost mode 11 is max.
p
Cooker hood CPT - Technical manual
13
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
SPARE PARTS
Pos. Quantity Designation Name CPTG CPTJ CPTR
1 5 CPEA-99-08 Ribbon cable (not for CPTn-5) lll
2 2 CPEA-99-07 Membrane panel (not for CPTn-5) l l
2 2 CPEG-99-01 Membrane panel (not for CPTn-5) l
3 1 CPTJ-99-06 Control card (not for CPTn-5) lll
3 1 CPTJ-99-07 Control card (for CPTJ-5 and CPTR-5) l l
3 1 CPTG-99-02 Control card (for CPTG-5) l
4 1 CPTJ-99-02 Driver LED lll
5.1 2 CPTJ-99-03 LED strips lll
5.2 2 CPTJ-99-01 LED spot (only for CPTJ-3) l
6 1 CPEA-99-05 Damper actuator lll
7 1 CPCA-99-12 Throttling device, complete (with basic flow) l l
8 1 CPDH-99-02 Throttling device, complete (without basic flow) l l
9 2 CPTJ-99-04 Grease filter lll
10 1 CPTG-99-01 Transformer l
11 25 BHGA-99-48 Plastic plugs l l
Always cut the power before starting any work on the equipment. All work must be carried out by qualified personnel to avoid hazard.
2 345.1 5.2
6
11
9
7 8
5101
Cooker hood CPT - Technical manual
14
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
EC DECLARATION OF CONFORMITY
ENCLOSURE II A
FläktGroup Sweden AB
Postal Address Street Address Telephone Telefax Reg. no:
FläktGroup Sweden AB Fläktgatan 1 Nat 036 - 19 30 00 Nat 036 - 19 31 40 556239-2463
S-551 84 Jönköping Int +46 36 19 30 00 Int +46 36 19 31 40 Reg. office:
Sweden Jönköping
9920GB_CPT Declaration of conformity(2A)201901
Declaration of Conformity
In accordance with:
EU Directive for Machinery, 2006/42/EC
EU EMC Directive, 2014/30/EU
EU RoHS Directive, 2011/65/EU
Manufacturer FläktGroup Sweden AB
Fläktgatan 1
551 84 Jönköping
Herewith declares that:
Product Type: Cooker Hood, Streamline
Manufacturer: FläktGroup Sweden AB
Commercial name: CPTJ/G/R ( several versions / variants)
The machine is designed and manufactured in accordance with the following standards, in relevant parts.
EN ISO 12100 Safety of machinery General principles for design- Risk assessment and risk reduction
EN 60204-1 Safety of machinery; electrical equipment of machines; general requirements
EN 60335-1 Household and similar electrical appliances - Safety - Part 1: General requirements
EN 60335-2-31 Household and similar electrical appliances - Safety - Part 2: Particular requirements
EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
EN 61000-6-3 Emission standard for residential, commercial and light-industrial environments.
EN 50106:2008 Safety of household and similar electrical appliances - Particular rules for routine tests
referring to appliances under the scope of EN 60335-1
EN 62233:2008 Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure
EN 61347-2-13 Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules
EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with
respect to the restriction of hazardous sustances
A risk analysis has been made according to requirements of the Directive for Machinery.
Authorized To prepare technical documentation:
Ann-Sofie Andersson
Design- R&D
FläktGroup Sweden AB
Fläktgatan 1
551 84 Jönköping
The declaration applies only to the installation made according to FläkGroups instructions and assuming no
changes made to the unit.
Jönköping 2019-01-01
Björn Norling, Quality Manager, FläktGroup Sweden AB, Jönköping
Cooker hood CPT - Technical manual
15
FläktGroup DC_9410GB_20190328_R3
We reserve the right to make changes without prior notice
Separate at source according to local
regulations. Depending on the product,
the following should be removed when
disposing of it:
- Circuit boards, cables, coils, motors,
sensors etc.
- Filters other than metal ones (cooker
hoods).
- Packaging material such as corrugated
cardboard, plastic and expanded poly-
styrene.
- Everything else should be disposed of as metal. However, it
should be noted that the unit also contains a vapour barrier,
and sometimes mineral wool enclosed between the internal
and external walls, which should be removed.
- Light bulbs and fluorescent tubes
See www.flaktgroup.com for recycling instructions.
DISPOSAL OF PRODUCTS AND PACKAGING MATERIALS
FG_DC_9410GB_CPT_IN-MA-CM-SP_20190328_R3 © Copyright 2019 FläktGroup J8013868-2301
WWW.FLAKTGROUP.COM CPT
» Learn more on www.flaktgroup.com
or contact one of our offices
FläktGroup is the European market leader for smart and energy efficient
Indoor Air and Critical Air solutions to support every application area. We offer our
customers innovative technologies, high quality and outstanding performance
supported by more than a century of accumulated industry experience. The wi-
dest product range in the market, and strong market presence in 65 countri-
es worldwide, guarantee that we are always by your side, ready to deliver
Excellence in Solutions.
PRODUCT FUNCTIONS BY FLÄKTGROUP
Air Treatment | Air Movement | Air Diffusion | Air Distribution | Air Filtration
Air Management & ATD’s | Air Conditioning & Heating | Controls | Service
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

FläktGroup CPT Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI