FläktGroup CPD is a cooker hood designed for multiple-unit dwellings with a central extract air fan or a heat recovery unit. It is suitable for both new production and replacement of older cooker hoods. The CPD has a low energy lamp and a grease filter that should be cleaned weekly. The device has several operating modes, including basic ventilation, forced ventilation, and boosting. The basic ventilation mode is suitable for everyday cooking, while the forced ventilation mode is suitable for more intensive cooking. The boosting mode is suitable for short periods of time when extra ventilation is needed.

FläktGroup CPD is a cooker hood designed for multiple-unit dwellings with a central extract air fan or a heat recovery unit. It is suitable for both new production and replacement of older cooker hoods. The CPD has a low energy lamp and a grease filter that should be cleaned weekly. The device has several operating modes, including basic ventilation, forced ventilation, and boosting. The basic ventilation mode is suitable for everyday cooking, while the forced ventilation mode is suitable for more intensive cooking. The boosting mode is suitable for short periods of time when extra ventilation is needed.

OPERATION, MAINTENANCE, INSTALLATION, COMMISSIONING, SPARE PARTS
COOKER HOOD CPD
Cooker hood CPD - Installation and Maintenance Manual
2
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CONTENT
WARNING! THE DEVICE CAN BE USED BY CHILDREN FROM 8 YEARS UPWARDS AND PEOPLE (INCLUDING
CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPA BILITIES, OR LACK OF EXPERIENCE AND
KNOWLEDGE UNLESS THEY HAVE RECEIVED GUIDANCE OR INFORMATION ON HOW TO USE THE DEVICE SAFELY
AND UNDERSTAND THE RISKS THAT CAN OCCUR. CHILDREN SHOULD NOT PLAY WITH THE APPLIANCE. CLEANING
AND MAINTENANCE IS NOT CARRIED OUT BY CHILDREN WITHOUT SUPERVISION.
MAINTENANCE (FOR THE USER)
Cleaning ........................................................................................................ 3
Replacing of the low energy lamp ...................................................... 3
General .......................................................................................................... 3
Operating of CPDA and CPDJ ..................................................................4
Operating of CPDB, CPDC, CPDG, CPDK ............................................ 5
INSTALLATION
(FOR INSTALLERS AND SERVICE PERSONNEL)
Installation height ..................................................................................... 6
Main supply ................................................................................................ 6
General .......................................................................................................... 6
CPDA ...............................................................................................................7
CPDB .............................................................................................................. 8
CPDC ............................................................................................................. 8
CPDG ............................................................................................................. 9
CPDJ ............................................................................................................ 10
CPDK ............................................................................................................11
ELECTRICAL CONNECTIONS
(FOR INSTALLERS AND SERVICE PERSONNEL)
CPDG .................................................................................................................... 12
ADJUSTMENT, COMMISSIONING
(FOR INSTALLERS AND SERVICE PERSONNEL)
CPD(A, B, C, G)- Basic ventilation ..................................................... 13
CPD(A, B, C, G) - Forced ventilation ..................................................14
CPD(K) - Basic ventilation ................................................................... 15
CPD(J, K) - Forced ventilation ............................................................. 16
GENERAL
Spare parts CPD(A, B, C, G, J, K) ................................................................... 17
Declaration of conformity ................................................................................18
Disposal of product and packaging materials ...................................... 19
Cooker hoods CPDD and CPDL, see separate instruction (8759).
Cooker hood CPD -Installation and Maintenance Manual
3
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
MAINTENANCE
CLEANING OF COOKER HOOD
Do not use abrasive sponge or cloth.
alt.
1
2
33
CLEANING OF GREASE FILTER
REPLACING OF THE LOW ENERGY LAMP
Check the grease filter every week.
Clean if needed.
Note! Do not use the cooker hood
without grease filter fitted.
GENERAL
There is a fire risk if cleaning is not carried out
in accordance with the instructions.
Accessible parts may become hot when used
with cooking appliances.
Do not flambé under the cooker hood.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid hazard.
8 W/E14
Cooker hood CPD - Installation and Maintenance Manual
4
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
MAINTENANCE
OPERATING OF CPDA AND CDPJ
Handle for boosting Lighting
Cooker hood CPD -Installation and Maintenance Manual
5
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
NORMAL
MIN
MAX
MIN
1
2
MIN
1
2
MIN
1
2
MAINTENANCE
OPERATING OF CPDB, CPDC, CPDG AND CPDK
Handle for boosting Lighting Handle for fan speed
MIN
1
2
Cooker hood CPD - Installation and Maintenance Manual
6
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
INSTALLATION HEIGHT MAIN SUPPLY
min 400 mm
All cooker hoods has to be connected directly or indirectly via the heat
recovery unit/exhaust fan to earth.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order
to avoid hazard.
The distance between the stove and the lower edge of the cooker hood
has to be at least 450 mm, recommended distance 500 mm.
When the cooker hood is located above a gas appliance, this distance
shall be at least 650 mm. If the instructions for installation of the gas
hob specify a greater distance, this has to be taken into account.
GENERAL
The air must not be discharged into a flue that is
used for exhausting fumes from appliances burn-
ing gas or other fuels.
Regulations concerning the discharge of air have
to be fulfilled.
450
Cooker hood CPD -Installation and Maintenance Manual
7
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDA
Intended for multiple-unit dwellings with a central extract air fan or a heat recovery unit.
Suitable for both new production and replacement of older cooker hoods.
INSTALLATION BENEATH KITCHEN CABINETS
a
a
b
b
INSTALLATION BETWEEN KITCHEN CABINETS
min 500 mm
2
3
1
max
300 mm
1
2
3
54
max
300 mm
12mm
Ø 50
160 100
a
min 500 mm
a =700
a =600
a =500
200
100
100
415
365
365
255
205
205
550
550
Cooker hood CPD - Installation and Maintenance Manual
8
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDB
Replacement hood for older exhaust air fan JBDD-aa with capacitor box, manufactured before 2007.
JBDD-aa
(earlier version)
CPCB
JBDD-aa
(earlier version)
a
a
b
b
CPDC
Replacement hood for older heat recovery unit RDKG without bypass (fits RDKG-a-1-c-d-1).
1
5
6
2
3
4
3.1 3.2
Remove the old
cooker hood.
It is important to seal the grommet by putting
back the small piece of sealing material.
Remove the old cooker hood.
Cooker hood CPD -Installation and Maintenance Manual
9
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CPDG
With transformer, fits for example the new JBDH. (Fits JBDD-aa-1-2, JBFG and also as replacement
cooker hood for controlling older exhaust air fans and units, for example JBDB, JBDC and RDAA.)
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
1
2
1 = Orange - Supply
voltage
to fan
2 = Blue - Neutral
3 = Black - Phase
4 = Yellow/Green - Ground
3
2
3
1
min 500 mm
CONNECTION TO EXHAUST FAN JBDD, GENERATION 2
INSTALLATION BETWEEN KITCHEN CABINETS
CONNECTION TO OTHER FANS
For electrical installation, see wiring examples on page 12.
INSTALLATION BENEATH KITCHEN CABINETS
2
3
1
JBDD generation 2
JBDH
Ø50
176
115
33
96
min 500 mm
160
550
550
Cooker hood CPD - Installation and Maintenance Manual
10
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDJ
For heat recovery unit RDKR or RDKS.
ab
3
2
1
RDKS
RDKS
4
5
4.1 4.2
7
6
It is important to seal the grommet by put-
ting back the small piece of sealing material.
The picture illustrates a right hand unit.
Cooker hood CPD -Installation and Maintenance Manual
11
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CPDK
For heat recovery unit RDKG. (Fits RDKG-a-b-c-d-2).
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
ab
2
1
3
4
All cooker hoods must be connected directly to earth. See also page 12.
Cooker hood CPD - Installation and Maintenance Manual
12
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL)
Note! Electrical connections have to be made by authorized personnel.
EXHAUST FAN JBDB EXHAUST FAN JBDC
1)
Not for
conversion kit
JBDB-99-05-0 JBDB
1)
CPDG/CPTG
Supply 230V
JBDA-99-031
2µF, not included
N
L
Blue
Blue White
Black
Black
Yellow/Green Yellow/Green
Orange
JBFG
CPDG/CPTG
Supply 230V
N
L
Blue Blue
Brown
Black
Yellow/GreenYellow/Green
Orange
JBDC
1)
CPDG/CPTG
N
L
1)
Also for
conversion kit
JBDB-99-05-0
Supply 230V
JBDA-99-031
2µF, not included
Brown
Blue Black
Blue
Black
Yellow/Green Yellow/Green
Orange
RDAA
CPDG/CPTG
Supply 230V
N
2 4 5 6 731
L
Orange
Black
Blue
Yellow/Green
CPDG
ROOF FAN JBFG HEAT RECOVERY UNIT RDAA
Cooker hood CPD -Installation and Maintenance Manual
13
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
ADJUSTMENT
b
c
a
Pa a = 7,5 10 12,5 15 20 25
250
200
100
50
40
30 5678910 12 15 20 30
Air flow q l/s
Measuring pressure pm, Pa
30
30 + 1xC
30 + 4xC
30 + 2xC
CPDA, CPDB, CPDC AND CPDG – BASICVENTILATION
p
Cooker hood CPD - Installation and Maintenance Manual
14
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CPDA, CPDB, CPDC AND CPDG – FORCED VENTILATION
When adjusting the forced air flow the fan speed must be increased up to the forced flow.
10
20
30
40
50
100
200
150
20 30 40 50 80
m
b = 5
a = 25 10
10
10
13
25
1015 15
15
25 25
25
7 9
a b
10
14
25
a
b
a
p
ADJUSTMENT
Cooker hood CPD -Installation and Maintenance Manual
15
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CPDK – BASIC VENTILATION
The basic air flow in the hood is adjusted by removing any number of plugs in the cover plate.
1
2
3
45
6
7
8
9
10
p
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
30
10
8
6
4
2
Air flow q, l/s
Measuring pressure p
m
, Pa
2, 4, 6, 8 och 10 = number of open holes in the cover plate.
Connection of the
measuring tube
ADJUSTMENT
When forcing the air stream must be mea sured at both measurement
points (basic flow and forced flow).
Cooker hood CPD - Installation and Maintenance Manual
16
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CDPJ AND CPDK - FORCED VENTILATION
Damper blade without basic flow valve (sealed damper blade)
When adjusting the forced air flow the fan speed must be increased up to the forced flow.
ADJUSTMENT
10
20
30
40
50
100
200
150
20 30 40 50 80
Air flow q, l/s
Measuring pressure pm, Pa
b = 7
13
14
15
8 9 11
p
b
Cooker hood CPD -Installation and Maintenance Manual
17
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
CPDA, CPDB, CPDC, CPDG, CPDH, CPDJ, CPDK AND CPDR
SPARE PARTS
Pos 5. R = Rght, M = Middle, L = Left
Cut the power before start working with the unit. All work has to be carried out by qualified personnel in order to avoid hazard.
1
2
3
6
12
13
9
4
4
8
14
15
7
10
5
11
Pos No. Designation Description Passande till CPD...
A B C G H J K M R
125 CPDA-99-01 Handle xxxxxxxxx
210 CPDA-99-02 Lightning switch xxxxxxxxx
3 1 CPDA-99-03 Front board 1-handle, 500 mm x
3 1 CPDA-99-04 Front board 1-handle, 600 mm x x x
3 1 CPDA-99-05 Front board 1-handle, 700 mm x x
3 1 CPDC-99-02 Front board 2-handles, 500 mm x x
3 1 CPDC-99-03 Front board 2-handles, 600 mm x x x x x x
3 1 CPDC-99-04 Front board 2-handles, 700 mm x x x
410+10 CPDA-99-07 Black plastic corners, right and left xxxxxxxxx
5 1 CPCA-99-15 Timer with shaft: 600 mm (R, L), 700 mm (R) xxxxx xx
5 1 CPDA-99-10 Timer with shaft: 500 mm (M), 600 mm (M), 700 mm
(M, L) x x x
5 1 CPDJ-99-01 Timer w. shaft: 600, 700 mm (w. contact function) x x
610 CPCA-99-09 Lamp socket xxxxxxx
610 CPDA-99-12 Lamp socket, transverse light xxxxxxxxx
7 1 CPCA-99-12 Throttling device, complete x x x x x
7 1 CPDH-99-02 Throttling device, complete (without basic flow) xxxxx
825 BHGA-99-48 Plastic plugs x x x x x x x
910 CPDA-99-06 Lamp protecting glass xxxxxxxxx
10 1CPCA-99-13 Grease filter xxxxxxxxx
11 5CPDC-99-01 Switch x x x x x x
12 1CPDG-99-01 Transformer x x
13 1CPDH-99-01 Time relay x
14 10 CPDA-99-15 Damper eccentric, 10-pack xxxxxxxxx
15 10 CPDA-99-13 Damper gasket, 10-pack xxxxxxxxx
Cooker hood CPD - Installation and Maintenance Manual
18
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
DECLARATION OF CONFORMITY
ENCLOSURE
II A
FläktGroup Sweden AB
Postal Address Street Address Telephone Telefax Reg. no:
FläktGroup Sweden AB Fläktgatan 1 Nat 036 - 19 30 00 Nat 036 - 19 31 40 556239-2463
S-551 84 Jönköping Int +46 36 19 30 00 Int +46 36 19 31 40 Reg. office:
Sweden Jönköping
8364GB_CPD Declaration of conformity(2A)202111
Declaration of Conformity
In accordance with:
EU Directive for Machinery, 2006/42/EC
EU EMC Directive, 2014/30/EU
EU RoHS Directive, 2011/65/EU
Manufacturer FläktGroup Poland Sp. z o.o
Ul. Poludniowa 2, Oltarzew
05-850 Ozarów Mazowiecki
Herewith declares that:
Product Type: Cooker Hood
Manufacturer: FläktGroup Sweden AB
Commercial name: CPD/A/B/C/D/G/H/J/K/L/R ( several versions / variants)
The machine is designed and manufactured in accordance with the following standards, in relevant parts.
EN ISO 12100 Safety of machinery General principles for design- Risk assessment and risk reduction
EN 60204-1 Safety of machinery; electrical equipment of machines; general requirements
EN 60335-1 Household and similar electrical appliances - Safety - Part 1: General requirements
EN 60335-2-31 Household and similar electrical appliances - Safety - Part 2: Particular requirements
EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
EN 61000-6-3 Emission standard for residential, commercial and light-industrial environments.
EN 50106:2008 Safety of household and similar electrical appliances - Particular rules for routine tests
referring to appliances under the scope of EN 60335-1
EN 62233:2008 Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure
EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with
respect to the restriction of hazardous sustances
A risk analysis has been made according to requirements of the Directive for Machinery.
Authorized To prepare technical documentation:
Ann-Sofie Andersson
Design- R&D
FläktGroup Sweden AB
Fläktgatan 1
551 84 Jönköping
The declaration applies only to the installation made according to FläktGroups instructions and assuming no
changes made to the unit.
Varsova 2021-11-01
Mariusz Zakrzewski, Operational Director, FläktGroup Poland Sp, Varsova
Cooker hood CPD -Installation and Maintenance Manual
19
FläktGroup DC_8757GB_20211105_R4
Specifications are subject to alteration without notice
DISPOSAL OF PRODUCT AND PACKAGING MATERIALS
Recycling should be made in accordance
with local regulations. When the product is
scrapped the following parts/components/
materials shall be sorted. Depending on
what product it is may not all parts/com-
ponents/materials be represented.
Printed circuit boards, cables, batteries,
motors, sensors etc.
Filters, except made of pure metal (in
cooker hoods).
Packaging materials, such as
cardboard, plastic and
styrofoam.
The units casing may contain condense- or mineral wool
insulation sandwiched between the inner and outer shell.
The remaining parts shall be sorted as metallic.
Lamps and fluorescent lights.
See www.flaktgroup.com for recycling instructions.
FG_DC_8757GB_CPD_IN-MA-CM-SP_20211105_R4 © Copyright 2021 FläktGroup J8013821-2301
WWW.FLAKTGROUP.COM CPD
» Learn more on www.flaktgroup.com
or contact one of our offices
FläktGroup is the European market leader for smart and energy efficient Indoor Air
and Critical Air solutions to support every application area. We offer our customers
innovative technologies, high quality and outstanding performance supported by more
than a century of accumulated industry experience. The widest product range in
the market, and strong market presence in 65 countries worldwide, guarantee
that we are always by your side, ready to deliver Excellence in Solutions.
PRODUCT FUNCTIONS BY FLÄKTGROUP
Air Treatment | Air Movement | Air Diffusion | Air Distribution | Air Filtration
Air Management & ATD’s | Air Conditioning & Heating | Controls | Service
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

FläktGroup CPD Installation and Maintenance Manual

Category
Cooker hoods
Type
Installation and Maintenance Manual

FläktGroup CPD is a cooker hood designed for multiple-unit dwellings with a central extract air fan or a heat recovery unit. It is suitable for both new production and replacement of older cooker hoods. The CPD has a low energy lamp and a grease filter that should be cleaned weekly. The device has several operating modes, including basic ventilation, forced ventilation, and boosting. The basic ventilation mode is suitable for everyday cooking, while the forced ventilation mode is suitable for more intensive cooking. The boosting mode is suitable for short periods of time when extra ventilation is needed.