Installation Instructions
Install the mounting tabs
Drill the holes and cut the door frame
as indicated by the template
Connect to the power and test the
electric strike before finally mounting
the unit
Mark the position of the latch bolt on
the door frame as shown in figure
Align the installation template
to the marked line
Measure the vertical and horizontal position
of the latch bolt on the door leaf
Installing on Wood Frame and Hollow Metal Frame:
Copyright © All Rights Reserved. P-MU-GK450 Published: 2017.03.31
17mm
LP-050 LP-025
2"(50mm)
1" (25mm)
Please ensure that there is no back pressure on the keeper from the latch. As with most strike this may cause the strike
to bind and malfunction. It could also cause undo pressure on the solenoid and eventual failure of the strike.
Note
In case of over-cutting, use the enclosed trim
plate to cover up any errors.
*Factory default setting is Fail-Secure.
Using the Trim Plate
Optional Lip Extension Brackets
Fail-Secure / Fail-Safe Reversible
Place the wire inside the connector and use pliers
to press down on the head of the connector evenly.
Installing the Crimp Connectors
9/16” (123.8mm)
3 3/8” (85.5mm)
1 1/4”(31.75mm)
11/16” (17mm)
CL
CL
7 15/16” (201.6mm)
1 7/16” (36.5mm)
11
/16” (17mm)
CL
CL
3 3/8” (85.5mm)
2. Reverse the round screw.
3. Put back the round
screw and plug.
Fail-Secure
when " 2"
facing up
Fail-Safe when
"1" facing up
1. Remove the plug and
take out the round
screw.