FSR SB-100 Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide
FSR 244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
43232 LIT1600
CAN FIT UP
TO 4 BOXES
STANDARD RACO 192 4" ELECTRICAL BOX
FSR P/N 48771 (3 BOXES SHOWN - SOLD SEPARATELY)
7.75 3.50 7.75
19.00
22.00
5.00
SECTION
6.00
9.63
#8-32 BOX MOUNTING HOLES
(HARDWARE SUPPLIED)
SB-100 MOUNTING HOLE
(8) .563 DIA HOLE
SB-100 INSTALLATION INSTRUCTIONS
NOTES:
COMBINED WEIGHT OF ALL LIGHTING/EQUIPMENT ATTACHED TO SB-100'S CENTER CROSS TUBE MUST NOT EXCEED 1,000 LBS.
ACCESSIBLE
KO LOCATIONS
WLL 1000lbs MAX
COMBINED WEIGHT OF ALL LIGHTING/EQUIPMENT
ATTACHED TO SB-100'S CENTER CROSS TUBE
MUST NOT EXCEED 1,000 LBS.
CONSULT A STRUCTURAL
ENGINEER TO VERIFY LOAD
RATING OF BUILDING STRUCTURE
AND ATTACHMENT MEANS.
ENSURE ALL MECHANICAL AND ELECTRICAL FITTINGS, WIRING, CONNECTORS AND INSTALLATION DETAILS CONFORM TO ALL
APPLICABLE CODES.
BUILDING STRUCTURE MUST BE ABLE TO WITHSTAND A LOAD OF 1,500 POUNDS MINIMUM AND UP TO 5,000 POUNDS FOR A BRIEF
PERIOD WITHOUT PERMANENT DEFORMATION TO ANY PART OF THE STRUCTURE, IN ORDER TO MAINTAIN A 5X SAFETY RATING.
CONSULT A STRUCTURAL ENGINEER TO VERIFY LOAD RATING OF BUILDING STRUCTURE.
MOUNTING HARDWARE SIZE USED MUST BE 1/2-13 GRADE 2 OR BETTER (or M12 x 1.75 CLASS 4.8 OR BETTER), WITH WASHERS
AND LOCK WASHERS/THREADLOCKING COMPOUND AS REQUIRED.
THE SB-100'S FOUR CENTER MOUNTING HOLES MUST BE USED, AND FSR RECOMMENDS ALL EIGHT MOUNTING HOLES BE USED
FOR SAFEST AND MOST SECURE INSTALLATION.
*
*
*
*
*
SB-100 MUST BE SECURED TO THE BUILDING STRUCTURE, AND BE PLUMB AND LEVEL.
*
14.30(8)
SB-100 MOUNTING HOLE
HOLE #8-32 BOX MOUNTING HOLES
(HARDWARE SUPPLIED)
196.85 88.90 196.85
482.60
558.80
SECTION
152.40
244.48
127.00
CAN FIT UP
TO 4 BOXES
STANDARD BS 4662
72mm SQ ELECTRICAL BOX
INTERNATIONAL CONFIGURATIONS INC
FSR P/N 48777
(1 BOX SHOWN - SOLD SEPARATELY)
STANDARD BS 4662
135mm x 75mm ELECTRICAL BOX
INTERNATIONAL CONFIGURATIONS INC
FSR P/N 48778
(2 BOXES SHOWN - SOLD SEPARATELY)
ACCESSIBLE
KO LOCATIONS
  • Page 1 1
  • Page 2 2

FSR SB-100 Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI