Kampmann Verlegepläne Katherm QK nano elektromechanisch 24V Installation Plan

Type
Installation Plan
01
Katherm QK nanoProduct:
Project Title:
Cable routing plan
03.11.2023
Blatt-Nr.:
5
Projekt-Nr.:
Bearbeiter:
Erstelldatum:
Projekt:
03.11.2023 2von
General Information
Information on cable laying:
The following information on cable types and cable laying must be observed in compliance with VDE 0100.
The installation, operation and maintenance of these devices must comply with the country-specific applicable laws, standards, regulations and directives.
Without *: NYM-J. The required number of cores incl. protective conductor is indicated on the cable. Cross sections are not indicated, as the cable length is included in the calculation of the cross
section.
*): Shielded cable, J-Y(ST)Y 0.8mm. Lay separately from power lines.
**): Shielded cable stranded in pairs, e.g. UNITRONIC® BUS LD 2x2x0.22, UNITRONIC® BUS LD 3x2x0.22. Install separately from power lines.
- If other cable types are used, they must be at least equivalent.
- The connection terminals on the device are suitable for a maximum wire cross-section of 2.5 mm².
- When using residual current circuit breakers, these must be at least mixed frequency sensitive (type F). For the design of the rated residual current, the specifications from DIN VDE 0100 Parts 400
and 500 must be observed.
- For the design of the on-site mains supply and fuse protection (C16A, max. 10 devices), the electrical data in the table below must be observed.
- Lines for data or bus signals are shown with shield connected at one end. Lines for analog signals are shown with the shield not connected. Due to structural or local conditions and depending on
the type and level of interference, which can be caused by magnetic and/or electric fields in high and/or low frequency ranges, among other things, a different connection of the shield (connected at
both ends or not connected) may be necessary. This must be checked by the customer and, if necessary, carried out deviating from the specifications in the documentation!
Electromechanical:
- Cable length between speed controller and the last device: maximum 100 m, from 20 m connect shield on one side.
- Cable length between room thermostat and temperature sensor or switch contact: maximum 50 m.
- Cable length between speed controller and temperature sensor or switching contact: maximum 100 m.
KaControl:
- Cable length temperature sensor or switching contact: maximum 30m (maximum 100m with minimum wire cross-section of 1.0 mm²).
- Cable length BUS cable room control unit KaController to unit 1: maximum 30 m.
- Maximum number of devices in parallel: 6 pieces. With CANbus card type 3260301 (see accessories) required for each unit: maximum 30 units.
- BUS cable length from device 1 to device 6: maximum 30 m. With CANbus card type 3260301 (see accessories) required for each device, maximum 500 m.
Blatt-Nr.:
5
Projekt-Nr.:
Bearbeiter:
Erstelldatum:
Projekt:
03.11.2023 3von
2
1
4
24V UC GND VH GND VK
GND24V
1
2
3
1
2
3
1
2
4
1
2
1
2
2*2*4*
GNDQ3GND Q1 Q2 I1 GND I2 GND24V
W8
W7
W6
1
2
3
4
1
2
3
4
4*
W3
4*
W2
ZKK
5*
W5
1
2
3
4
1
2
3
4
1
2
3
4
ZKK
1
2
3
4
1
2
2*
W1
4*
W4
2
1
4
3
GNDQ3GND Q1 Q2 I1 GND I2 GND24V
24V UC GND VH GND VK
1
2
NO COM 1 2
Nominal voltage
24V DC
Fuse protection on site.
See the information in the
"Electrical data" table.
mains
24V DC
Katherm QK nano
electromechanical 24V
(*24)
Device no. 1
Fan connection
Nominal voltage
24V DC
+ Control
0-10V DC
Actuator
heating
Type 146906 Nominal voltage
24V DC
+ Control
0-10V DC
Fan connection
Katherm QK nano
electromechanical 24V
(*24)
Device no. 2
Actuator
heating
Type 146906
Clock thermostat
Type 30456
- Options -
For more information, see the manual of the clock
thermostat
Contact
e.g. heating/cooling Room sensor
To further devices
(Max. number see information)
Katherm QK nano, elektromechanical 24V,
2-pipe, valve drive 24V AC/DC open/close,
Clock thermostat Type 30456
Blatt-Nr.:
5
Projekt-Nr.:
Bearbeiter:
Erstelldatum:
Projekt:
03.11.2023 4von
3
1
2
4
2
4
DO
24V
DO
24V
AA
0-10V
5
5
6*
W5
5*
W1
24V GND
1
3
GND
3
1
2
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
ZKK
1
2
3
4
5
1
2
3
4
5
ZKK
1
2
3
4
5
5*
W2
5*
W4
5*
W3
24V UC GND VH GND VK 24V UC GND VH GND VK
Katherm QK nano
electromechanical 24V
(*24)
Device no. 1
Fan connection
Nominal voltage
24V DC
+ Control
0-10V DC
Actuator
heating
Type 146906
Katherm QK nano
electromechanical 24V
(*24)
Device no. 2
Fan connection
Nominal voltage
24V DC
+ Control
0-10V DC
Actuator
heating
Type 146906
To further devices
(Number depends on the maximum
current of the analogue outputs of the BA)
Building Automation (BA)
Nominal voltage
(24V DC) Fuse protection on site.
Valve drive heating
Valve drive cooling
Speed
Note the internal resistance of the
unit!
Katherm QK nano, electromechanical 24V,
2-pipe, valve drive 24V AC/DC open/close,
Control via GA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Kampmann Verlegepläne Katherm QK nano elektromechanisch 24V Installation Plan

Type
Installation Plan