CyberData 011187 is a 2-Port PoE Gigabit Switch that provides both power and data over a single Ethernet cable. It is fully compliant with the IEEE 802.3af/at standard, making it compatible with a wide range of PoE devices. The switch has one Power Device (PD) input port and two Power Source Equipment (PSE) output ports. The PD input port can receive power from either an 802.3af or 802.3at PoE injector, while the PSE output ports can provide power to two PoE-powered devices.

The switch also supports 10/100/1000Mbps data rates, making it suitable for use in high-speed networks.

CyberData 011187 is a 2-Port PoE Gigabit Switch that provides both power and data over a single Ethernet cable. It is fully compliant with the IEEE 802.3af/at standard, making it compatible with a wide range of PoE devices. The switch has one Power Device (PD) input port and two Power Source Equipment (PSE) output ports. The PD input port can receive power from either an 802.3af or 802.3at PoE injector, while the PSE output ports can provide power to two PoE-powered devices.

The switch also supports 10/100/1000Mbps data rates, making it suitable for use in high-speed networks.

2-Port PoE Gigabit Switch
Operations Guide
Part #011187
Document Part #930591G
for Firmware Version 1.0.0
CyberData Corporation
3 Justin Court
Monterey, CA 93940
(831) 373-2601
The IP Endpoint Company
CyberData Corporation 930591G Operations Guide
2-Port PoE Gigabit Switch Operations Guide 930591G
Part # 011187
COPYRIGHT NOTICE:
© 2021, CyberData Corporation, ALL RIGHTS RESERVED.
This manual and related materials are the copyrighted property of CyberData Corporation. No part of
this manual or related materials may be reproduced or transmitted, in any form or by any means
(except for internal use by licensed customers), without prior express written permission of
CyberData Corporation. This manual, and the products, software, firmware, and/or hardware
described in this manual are the property of CyberData Corporation, provided under the terms of an
agreement between CyberData Corporation and recipient of this manual, and their use is subject to
that agreement and its terms.
DISCLAIMER: Except as expressly and specifically stated in a written agreement executed by
CyberData Corporation, CyberData Corporation makes no representation or warranty, express or
implied, including any warranty or merchantability or fitness for any purpose, with respect to this
manual or the products, software, firmware, and/or hardware described herein, and CyberData
Corporation assumes no liability for damages or claims resulting from any use of this manual or such
products, software, firmware, and/or hardware. CyberData Corporation reserves the right to make
changes, without notice, to this manual and to any such product, software, firmware, and/or
hardware.
OPEN SOURCE STATEMENT: Certain software components included in CyberData products are
subject to the GNU General Public License (GPL) and Lesser GNU General Public License (LGPL)
“open source” or “free software” licenses. Some of this Open Source Software may be owned by third
parties. Open Source Software is not subject to the terms and conditions of the CyberData
COPYRIGHT NOTICE or software licenses. Your right to copy, modify, and distribute any Open
Source Software is determined by the terms of the GPL, LGPL, or third party, according to who
licenses that software.
Software or firmware developed by CyberData that is unrelated to Open Source Software is
copyrighted by CyberData, subject to the terms of CyberData licenses, and may not be copied,
modified, reverse-engineered, or otherwise altered without explicit written permission from
CyberData Corporation.
TRADEMARK NOTICE: CyberData Corporation and the CyberData Corporation logos are
trademarks of CyberData Corporation. Other product names, trademarks, and service marks may be
the trademarks or registered trademarks of their respective owners.
Technical Support
The fastest way to get technical support for your VoIP product is to
submit a VoIP Technical Support form at the following website:
http://support.cyberdata.net/
Phone: (831) 373-2601, Ext. 333
Fax: (831) 373-4193
Company and product information is at www.cyberdata.net.
The IP Endpoint Company
Operations Guide 930591G CyberData Corporation
Revision Information
Revision 930591G, which corresponds to design version 1.0.0, was released on March 19, 2021,
and has the following changes:
Adds Section 1.1, "How to Identify This Product".
Updates Section 1.2, "Features".
Updates Section 1.3, "Specifications".
Updates Section 1.4, "Compliance".
Adds Chapter 2, “Installing the 2-Port PoE Gigabit Switch.
Updates Figure 4, "Typical Installation of the 2-Port PoE Gigabit Switch"
CyberData Corporation 930591G Operations Guide
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
11. Prior to installation, consult local building and electrical code requirements.
CyberData Corporation 930591G Operations Guide
Pictorial Alert Icons
Hazard Levels
Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury. This is limited to the most extreme situations.
Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
Caution: Indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury. It may also alert users against unsafe practices.
Notice: Indicates a statement of company policy (that is, a safety policy or protection of property).
The safety guidelines for the equipment in this manual do not purport to address all the safety issues
of the equipment. It is the responsibility of the user to establish appropriate safety, ergonomic, and
health practices and determine the applicability of regulatory limitations prior to use. Potential safety
hazards are identified in this manual through the use of words Danger, Warning, and Caution, the
specific hazard type, and pictorial alert icons.
General Alert
This pictoral alert indicates a potentially hazardous situation. This alert will be
followed by a hazard level heading and more specific information about the
hazard.
Ground
This pictoral alert indicates the Earth grounding connection point.
GENERAL ALERT
i
Operations Guide 930591G CyberData Corporation
Contents
Chapter 1 Product Overview 1
1.1 How to Identify This Product .................................................................... 1
1.2 Features .................................................................................................. 2
1.3 Specifications .......................................................................................... 3
1.4 Compliance .............................................................................................. 4
1.4.1 CE Statement ......................................................................................................... 4
1.4.2 FCC Statement ....................................................................................................... 4
Chapter 2 Installing the 2-Port PoE Gigabit Switch 5
2.1 Checklist .................................................................................................. 5
2.2 Installation ............................................................................................... 5
2.2.1 Installation Method ................................................................................................. 5
2.2.2 Desktop or Shelf Installation ................................................................................... 5
2.3 Powering on the 2-Port PoE Gigabit Switch ............................................ 6
2.3.1 How the Input Power is Distributed ........................................................................ 6
2.4 Network Connection ................................................................................ 7
Appendix A The Standard RJ-45 Introduction 8
A.1 The Standard Cable, RJ-45 Pin Assignment .......................................... 9
Appendix B Mounting 10
B.1 Dimensions and Mounting Hole Measurements ................................... 10
B.2 Mounting Option .................................................................................... 11
Appendix C Typical Installation 12
C.1 Example ................................................................................................ 12
1
Operations Guide 930591G CyberData Corporation
1 Product Overview
1.1 How to Identify This Product
To identify the 2-Port PoE Gigabit Switch, look for a product label similar to the one shown in
Figure 1-1. Confirm the following:
The part number on the label should be 011187.
The serial number on the label should begin with 187.
Figure 1-1. Product Label
OUT1 OUT2 IN
The IP Endpoint Company
2 Port Gigabit with
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
SN:
802.3at Class 4 Type 2802.3at Class 0 Type 1
PSE PSE PD
Link/ActPwr Link/ActPwr Link/ActPwr
PoE Power Splitter
187100001
PN:011187B
CyberData Corporation
www.cyberdata.net
Serial number begins with 187The part number on the label should be 011187
Product Overview
Features
Operations Guide 930591G CyberData Corporation
2
1.2 Features
Power
Fully compliant to IEEE 802.3af/at standard
1 Power Device (PD) input port 802.3af or 802.3at
2 Power Source Equipment (PSE) output ports 802.3af or 802.3at (limited PD input)
Data
All ports are 10/100/1000Mbps (10BASE-T, 100BASE-TX, 1000BASE-T) auto sensing based
upon the port's individual connection
Each port has auto MDI-X
802.11q VLAN tagging
Automatic address learning, address aging and address migration
Supports 9216-byte jumbo frame length
Notification
Link/Status and connection speed LEDs
Product Overview
Specifications
Operations Guide 930591G CyberData Corporation
3
1.3 Specifications
Specifications
Ethernet I/F 10/100/1000 Mbps, Auto MDI-X, RJ45
Power Distribution
Input
Internal Circuit Use
Output
a
PD input up to 30W:
802.3af @ 15W
802.3at @ 25W
Generic PoE Injector up to 30W
2W
Power available to share between two PSE outputs:
13W with 802.3af input
23W with 802.3at input
28W with generic 30W PoE injector input
Operating Range Temperature: -40
o
C to 55
o
C (-40
o
F to 131
o
F)
Humidity: 5-95%, non-condensing
Storage Temperature
Storage Altitude
-40
o
C to 70
o
C (-40
o
F to 158
o
F)
Up to 15,000 ft. (4573 m)
Dimensions
b
5.31 inches [134.8 millimeter] Length
3.03 inches [76.9 millimeter] Width
1.06 inches [26.9 millimeter] Height
Weight
Boxed Weight
0.56 lbs [0.25 kg]
1.0 lbs [0.54 kg]
Compliance CE: EMC Directive – Class A EN 55032 & EN 55035, LV Safety Directive
– EN 62368-1; RoHS Compliant; FCC P
art 15 Class A; IEEE 802.3 Compliant
Part Number 011187
Table 1-1. Specifications
a. Either one or both of the PSE outputs can provide PoE power as long as the overall PSE output wattage is 2W less
than the PD input.
b. Dimensions are measured from the perspective of the product being upright with the front of the product facing you.
Product Overview
Compliance
Operations Guide 930591G CyberData Corporation
4
1.4 Compliance
1.4.1 CE Statement
As of the date of manufacture, this product has been tested and found to comply with the
specifications for CE marking and standards per EMC and Radiocommunications Compliance.
EMC Directive - Class A Emissions, Immunity, and LV Safety Directive, RoHS Compliant.
Flammability rating on all components is 94V-0.
1.4.2 FCC Statement
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for
compliance could void the user's authority to operate the equipment.
5
Operations Guide 930591G CyberData Corporation
2 Installing the 2-Port PoE Gigabit Switch
2.1 Checklist
Before you start installing your equipment, verify that the package contains the following:
The 2-Port PoE Gigabit Switch
The 2-Port PoE Gigabit Switch Quick-Reference Placemat
Please notify your supplier immediately if any of the previously items are missing or damaged.
2.2 Installation
2.2.1 Installation Method
The site where you install the switch may greatly affect its performance. When installing, please take
the following into consideration.
Install the switch in a cool, dry place. See technical specifications for the acceptable
temperature and humidity operating ranges.
Install the switch on a secure, level surface that can support its weight (at least 1Kg).
Alternatively, the switch can be applied to any smooth dry surface using furnished stick-on tape.
Leave at least 10cm of space at the front and rear of the switch to ensure adequate ventilation.
2.2.2 Desktop or Shelf Installation
When installing the switch on a shelf on desktop, make sure that the previously mentioned
guidelines in
Section 2.2.1, "Installation Method" are followed for adequate ventilation.
Installing the 2-Port PoE Gigabit Switch
Powering on the 2-Port PoE Gigabit Switch
Operations Guide 930591G CyberData Corporation
6
2.3 Powering on the 2-Port PoE Gigabit Switch
The switch is powered by your existing central POE Switch. No additional power supply is required.
Simply plug your cable from your central POE switch into the PD port of the switch and your switch
will power on for use.
Figure 2. Front Panel of the 2-Port PoE Gigabit Switch
2.3.1 How the Input Power is Distributed
The PD input can be up to 30W.
A 802.3af source @ 15W
A 802.3at source @ 25W
A generic PoE injector up to 30W
The internal circuits on the splitter takes 2W to operate.
With an 802.3af input, 13W are available to share between the two PSE outputs.
With an 802.3at input, 23W are available to share between the two PSE outputs.
With a generic 30W PoE injector, 28W are available to share between the two PSE outputs.
Link / Activity (green)
PSE-1 Power ON (yellow) PSE-2 Power ON (yellow) PD Power ON (yellow)
Table 2. Powering on the 2-Port PoE Gigabit Switch
LED Status Description
PD (Orange) ON Switch has a connection from the PD port to the PSE device.
Power has been successfully applied.
OFF Connection to the PSE device is not present.
No power has been applied to the switch.
PSE (Orange) ON PD device such as IP phone is connected to the port and
drawing power.
OFF PD device is not connected or no power is being drawn from
the switch.
Link/Act (Green) ON
A valid link
is
established.
Blink Traffic is present on port.
OFF
No
link
has been established.
Installing the 2-Port PoE Gigabit Switch
Network Connection
Operations Guide 930591G CyberData Corporation
7
2.4 Network Connection
Figure 3. Front Panel of 2-Port PoE Gigabit Switch
Connect your devices (computer, router, switch, IP Phone, Wireless Access Point, IP Camera etc.) to
the ports with a CAT-5/CAT-5e/CAT-6 network cable. Since the switch supports Auto MDI/MDI-X, you
can use either a straight through or cross-over network cable.
Figure 4. Typical Installation of the 2-Port PoE Gigabit Switch
Connect the switch from the PD port to your central Gigabit PoE Switch.
Connect your IP Phone from the PSE port on the switch.
Connect your computer or other networking device to any of the PSE2 ports on the switch.
Link / Activity (green)
PSE-1 Power ON (yellow) PSE-2 Power ON (yellow) PD Power ON (yellow)
8
Operations Guide 930591G CyberData Corporation
Appendix A: The Standard RJ-45 Introduction
Regarding cable-making methods, a cable which does not meet the standards of the sequence data
will make the data transmission speed slow, unstable and even be blocked.
Tabl e A-1 represents the
standard RJ-45 jack and the connector (Figure A-1) and pin definition:
Figure A-1. Standard RJ-45 Jack / Connector
Table A-1. RJ-45 Connector Pin Definitions
Pin Number Signal
1_TX1 +(PoE Power+)
2 _TX1 - (PoE Power+)
3 _RX1 + (PoE Power-)
4_TX2 +
5_TX2 --
6 _RX1 - (PoE Power-)
7_RX2 +
8_RX2 -
The Standard Cable, RJ-45 Pin Assignment
Operations Guide 930591G CyberData Corporation
9
A.1 The Standard Cable, RJ-45 Pin Assignment
The following figures shows a straight cable and a crossover cable connection. Use a straight cable
connection to connect switch/Hub or other devices:
Figure A-2. Straight cable for the switch (uplink MDI-II port) to switch/Hub or other devices
connection.
Figure A-3. Crossover cable for switch (MDI-X port) to switch/hub or other network devices
(MDI-X port) connection.
10
Operations Guide 930591G CyberData Corporation
Appendix B: Mounting
B.1 Dimensions and Mounting Hole Measurements
Figure B-1 shows the dimensions and mounting hole measurements for the 2-Port PoE Gigabit
Switch.
Figure B-1. Dimensions and Mounting Hole Measurements
4.832 [122.7]
DIMENSIONS ARE IN INCHES [MILLIMETER]
3.033 [77.0]
1.063 [27.0]
5.305 [134.7]
Ø0.217
[Ø5.5]
PSE PSE PD
CyberData Corporation
www.cyberdata.net
Mounting Option
Operations Guide 930591G CyberData Corporation
11
B.2 Mounting Option
Figure B-2 shows a mounting option for the 2-Port PoE Gigabit Switch.
Figure B-2. Mounting
Mounting Option:
1. Mounting Screw
• Use a size 6 to 8 pan head screw.
2. Adhesive
• Peel off the adhesive backing and
attach the unit to a suitable surface.
12
Operations Guide 930591G CyberData Corporation
Appendix C: Typical Installation
C.1 Example
Figure C-1 shows a typical installation setup for the 2-Port PoE Gigabit Switch.
Figure C-1. Typical Installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

CyberData 011187 Operations Guide

Category
Network switches
Type
Operations Guide

CyberData 011187 is a 2-Port PoE Gigabit Switch that provides both power and data over a single Ethernet cable. It is fully compliant with the IEEE 802.3af/at standard, making it compatible with a wide range of PoE devices. The switch has one Power Device (PD) input port and two Power Source Equipment (PSE) output ports. The PD input port can receive power from either an 802.3af or 802.3at PoE injector, while the PSE output ports can provide power to two PoE-powered devices.

The switch also supports 10/100/1000Mbps data rates, making it suitable for use in high-speed networks.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI