4 Table of Contents WAGO I/O System 750 XTR
750-495/040-010 3-Phase POM 20KV 300A XTR
Manual
Version 1.0.0
5.1 Overview of the Process Data ............................................................... 47
5.2 Output Data............................................................................................ 48
5.2.1 Definition of the Control Words ......................................................... 48
5.2.2 Definition of the Output Data Words .................................................. 49
5.3 Input Data .............................................................................................. 50
5.3.1 Definition of the Status Words ........................................................... 50
5.3.2 Definition of the Input Data Words .................................................... 55
5.4 Descriptions for the Process Image ....................................................... 59
5.4.1 AC Measured Value Collection (010) ................................................ 60
5.4.2 Harmonic Analysis Collections (020, 021, 022) ................................. 61
5.4.3 Transient Reaction Measured Values ............................................... 63
5.5 Measured Value Collections .................................................................. 64
5.5.1 Collection 010 – AC Measured Values .............................................. 64
5.5.2 Collections 020, 021 and 022 – Harmonic Analysis .......................... 68
5.6 Examples of the Calculation of the Measured Values from the
Process Values ...................................................................................... 69
6 Mounting ................................................................................................... 71
6.1 Mounting Sequence ............................................................................... 72
6.2 Inserting and Removing Devices ........................................................... 73
6.2.1 Inserting the I/O Module .................................................................... 73
6.2.2 Removing the I/O Module.................................................................. 74
7 Connect Devices ....................................................................................... 75
7.1 Protection against Hazardous Touch Voltages ...................................... 75
7.2 Shielding ................................................................................................ 76
7.2.1 General ............................................................................................. 76
7.2.2 Fieldbus Cables................................................................................. 76
7.2.3 Shielded Signal Lines ........................................................................ 77
7.3 Connecting a Conductor to the CAGE CLAMP
®
.................................... 78
7.4 Measurement of Voltage, Current and Power ........................................ 79
8 Commissioning ......................................................................................... 81
8.1 General .................................................................................................. 81
8.1.1 Software Interface ............................................................................. 82
8.1.2 “Start” Ribbon .................................................................................... 84
8.1.3 “Measured Value Views” Menu ......................................................... 84
8.1.4 Status Bar ......................................................................................... 85
8.1.5 “Settings” Dialog ................................................................................ 86
8.1.6 Setting Measurement Units ............................................................... 88
8.2 Settings and Measured Values .............................................................. 89
8.2.1 “I/O Module” Tab ............................................................................... 89
8.2.2 Tabs “Phase L1,” “Phase L2” and “Phase L3” ................................... 91
8.2.3 “Energy” Tab ..................................................................................... 92
8.2.4 “Factory Settings” Tab ....................................................................... 94
8.2.5 Displaying the Measured Values with WAGO-I/O-CHECK ............... 96
8.2.5.1 “Overview” View ........................................................................... 96
8.2.5.2 “Current/Voltages” View ............................................................... 98
8.2.5.3 “Powers” View .............................................................................. 99
8.2.5.4 “Energies” View .......................................................................... 100
8.2.5.5 “Upper Harmonics” View ............................................................ 101