Digital Watchdog Spot DW-HDSPOTMOD16 User manual

Type
User manual

This manual is also suitable for

Before operating the system, please read this user manual and retain it for future
reference.
The picture might differ according to the specification and model.
Copyright © DW. All rights reserved. Specifications and pricing are subject to change without notice.
Rev: 07/20
USER MANUAL
DW Spot™ Monitoring Module
[2]
WARNING
TO REDUCE FIRE OR SHOCK HAZARD,
DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE.
The installation should be made by a qualified service
person and conformed to all local codes.
[3]
Cautions
Read Before System Operation
Follow these details to prevent material damage or personal injury.
Signs of Caution and Warning
Warning: This sign indicates that the user could die or be seriously wounded if not
used or installed properly.
Caution: This sign indicates that the user could be wounded or could expect property damage if not used or installed
properly.
Warning: Do not expose the product to fog, rain, or too much humid to decrease the danger from electric shock or fire
.
General Warning
Warning
1. Use the power cord, which is supplied or recommended by the supplier, or it may cause a fire.
2. Do not disassemble or reassemble the product. It may cause malfunction or fire.
3. Enquire to your vendor for repair. It may cause electric shock or fire if the repair is not done properly.
4. Do not touch the product with wet hands. It may cause malfunction or electric shock.
5. Product installation must be ensured to a professional for product installation, or it may cause malfunction, electric shock, or fire.
6. Ground applies to video products equipped with a 3-wire grounding type plug having a third (grounding) pin. This plug only fits
into a grounding-type power outlet. If grounding is not done, it may cause malfunction or electric shock.
7. A ground connection must not touch the gas pipe, water pipe, or telephone line. If grounding is not done properly, it may cause
electric shock.
8. Prevent metallic foreign substances from going inside the product. It may cause malfunction or electric shock.
9. Do not spray insecticide or flammable spray while driving. It may cause a fire.
10. Place the system in an open place where air ventilation is guaranteed, or it may cause over-heating and seriously damage the system
to be fired.
11. Prevent water from instilling inside electrical parts. Clean with a dry towel or malfunction or electric shock could result.
Caution
1. Use the power cord, which is supplied or recommended by the supplier. The internal fan rotates at high speed and may cause an
accident.
2. Do not drop, give strong vibration or shock to the product. It may cause malfunction.
3. The air inhaler of the front panel and air outlet of the back panel must not be blocked during installation.
The internal temperature of the product would be greater than allowable and could cause malfunction or fire.
4. Do not touch the product or the power cord when there is thunder. It may cause an electric shock.
5. Do not install the product near or on top of the heating source. The internal temperature of the product would be greater than
allowable and could cause malfunction or fire.
6. Do not install the product on an inclined or unstable location or where vibration could be committed. It may cause malfunction.
Cautions about the Power
Warning
1. Must use the outlet of the grounding to connect the power cord, or it may cause a fire.
2. Do not connect in the middle of the power cord or use the extension cord. It may generate heat or cause a fire.
3. Do not touch the power cord with wet hands. It may cause an electric shock.
4. Keep the power cord dry and protect from humidity. It may generate heat or cause a fire. The power cord is not waterproof.
5. Hold the body of the plug while removing the power plug. Do not pull the power cord. Damage to the power cord may generate
heat or cause a fire.
6. Check the power plug regularly. Humidity and moderation in smoking may cause a fire.
7. Remove the power cord from the outlet when the product is not used for a long time. It may cause short-circuit or electric shock.
Caution
1. Do not turn off the power by removal of the power plug.
To turn off the power, click the power button from the front panel.
When the system stops abnormally, the power button might not work. Click the power button for 5 full seconds to turn the power off.
2. Do not cut off the power artificially, or give shock or vibration to the unit while the hard disk is activating. It may cause hard disk
failure or loss of data.
Remarks
Pictures and buttons are subject to be changed or modified up to different models.
Function or configuration is subject to be changed or modified without prior notice for improvement of the product.
User Manual
[4]
Ta b l e o f Contents
1.
GETTING STARTED ................................................................................................................................. 5
1.1 Checking Supplied Items .................................................................................................................................... 5
1.2 System Startup ....................................................................................................................................................... 6
1.3 System Shutdown ................................................................................................................................................. 6
1.4 System Overview ................................................................................................................................................... 7
2.
STARTUP WIZARD .................................................................................................................................. 9
2.1 Language ................................................................................................................................................................. 9
2.2 Network .................................................................................................................................................................... 9
2.3 Camera Management .......................................................................................................................................... 11
2.4 Finish........................................................................................................................................................................ 12
3.
OPERATION .............................................................................................................................................. 12
3.1 User Log-in ............................................................................................................................................................ 12
3.2 DVR/NVR/CAM Registration ........................................................................................................................... 13
3.3 Deleting Devices .................................................................................................................................................. 15
3.4 Live Display Mode ............................................................................................................................................... 15
4.
SETTING .................................................................................................................................................... 19
4.1 System .................................................................................................................................................................... 20
4.2 Monitoring ............................................................................................................................................................. 26
4.3 Network ..................................................................................................................................................................27
5.
WEB SURVEILLANCE THROUGH INTERNET EXPLORER ............................................................ 31
5.1 Web Login.............................................................................................................................................................. 31
5.2 Web Setup ............................................................................................................................................................ 32
6.
Q & A ......................................................................................................................................................... 34
7.
PRODUCT SPECIFICATIONS ............................................................................................................... 35
8.
WARRANTY INFORMATION ................................................................................................................ 36
9.
LIMITS AND EXCLUSIONS ................................................................................................................... 37
Spot™ Monitoring Module
[5]
1.
Getting Started
1.1
Checking Supplied Items
Make sure that you have the following items supplied with your module. If any of these items are missing
or damaged, notify your vendor immediately. Keep the packing utilities for moving or storage purposes.
Items
Photo
Quick setup and
download guides
1 set
12V D/C power cable
1 set
USB mouse
1
User Manual
[6]
1.2
System Startup
After connecting peripheral devices such as monitors and a mouse to the module, power up the
module by connecting DC12V adaptor/ power cable to the power jack on the rear panel. The boot
logo will display. Please wait until the boot process completes.
When the system is up, the password change window is displayed. The user must set the password to
a minimum of 8 characters with at least 3 combinations of uppercase letters, lower case letters, numbers
and special characters. Acceptable special characters are ~ ‘ ! $ ^ ( ) _ - | { } [ ] ; . ? /. To login, right-
click anywhere on the screen and enter the username and password in the popup screen. There is only
one Administrator Account configurable in the module. It is assigned with an unchangeable User ID
marked as ‘admin’. The administrator account has full access to the module and its configurable
parameters and can also create new users and assign rights to the new user accounts.
If the module is set as AUTO LOGIN, the login process is not necessary.
Caution
1) It may take a few minutes to start up the system after turning on the power, in case the
user sets the network configuration as DHCP mode but under the situation that there is
no DHCP server in the network or the network is not connected.
2) The mouse is included. In case you need to replace it, it is highly recommended to
choose well-known major brands such as DELL, MICROSOFT, LOGITECH, or
SAMSUNG.
Note
1) Contact DW’s technical support to reset your password.
2) Refer to “Section 4.1.2 User” for AUTO LOGIN and AUTO LOGOFF.
1.3
System Shutdown
To turn off the power, click the exit button [ ] the toolbar, then select SHUTDOWN in the Exit
screen.
Input the password and click the OK button to shut down the system. Click the YES button to confirm
shutdown.
Note
Input passwords using the virtual keyboard.
Spot™ Monitoring Module
[7]
1.4
System Overview
Front Panel
1. USB Port: for USB mouse, import, and export settings and firmware upgrade.
2. LED Indicator: Indicates system status. (Power, Record and Network status)
Back Panel
1. VGA out: connect a VGA monitor to the unit (cables not included).
2. HD out: Connect a true HD monitor to the unit (cables not included).
3. LAN: Connect an RJ45 cable to the unit to connect it to the local network (cables not
included).
4. Power: Connect the 12V DC power cable to the unit and then to an adequate power supply.
User Manual
[8]
Tool Bar
In live view, move the mouse cursor to the bottom of the screen to show the menu bar.
Menu
Click on the menu button to access the module’s main menu screen. See “4. Setting” for details.
Display Mode
Select the display split mode from the available options. Select 1CH, 4CH, 9CH or 16CH mode.
Sequence
Start/stop the sequence mode in live mode. The sequence is disabled if all channels are displayed.
Channel
Switch to a single-channel view of a specific channel by pressing the corresponding number.
Exit
Exit the module with three different options: Log Off, Reboot and Shutdown.
Pin
When selected, the menu bar will be fixed on the screen permanently, regardless of the mouse’s
position.
Spot™ Monitoring Module
[9]
2.
Startup Wizard
When the module is launched for the first time, the STARTUP WIZARD will appear. This wizard helps
you setup the module’s most basic settings for proper functioning. You can access the Startup Wizard
screen at any time by clicking the Startup Wizard button under the MENU>SYSTEM>SETTINGS menu.
(See “4.1.5 SETTINGS”). If “DISPLAY ON SYSTEM STARTUP” is selected, Startup Wizard will appear
every time the system reboots.
2.1
Language
Select the language from the available drop-down options. Click APPLY to save the changes and
NEXT to move to the next screen.
.
2.2
Network
Setup the module’s network settings for remote connection.
Network Type
DHCP: The module will acquire all the network settings automatically according to the current
network requirements. Click the IP DETECT’ button to automatically fill out all the network settings.
Static IP: manually enter all the network settings. For proper configuration, it is recommended to
assign the module a DHCP address and let it auto-discover all the proper network settings, and
then change the Network Type back to Static IP and save the changes. Contact your Network
User Manual
[10]
Administrator for more information.
IP Address
If DHCP is selected, the IP address will automatically adjust to match the network’s requirements.
You may manually change the IP address as needed (Network Type must be set to Static).
Subnet Mask
Subnet Mask address classifies the subnet that the system belongs to. Contact your Network
Administrator for more information.
Gateway
This is the IP address of the router or gateway server. It is required when connecting to the module
through the external router over the internet (from another network). Contact your Network
Administrator for more information.
DNS Server
Enter the IP address of the Domain Name Server. You should input the DNS Server information to
use DDNS, E-mail notifications and NTP Server. Contact your Network Administrator for more
information.
WEB Port
Input the port number to use when connecting from the Web Browser. The default is 80. Contact
your Network Administrator for more information.
Auto IP
Displays the system’s IP address.
Use UPnP (Universal Plug and Play)
UPnP is a plug-and-play feature that allows the module to be automatically discovered by a PC on
the same network. To locate the module, go to “My Network” on your PC. The computer will scan
your network for all supported devices. The first five characters of the file name of a detected
module represent the model number, followed by the module’s IP address
Once the PC discovered the module, double click on the icon to open the module’s web client.
Enter your User ID and Password to login and click ‘Connect’ to connect.
Spot™ Monitoring Module
[11]
2.3
Camera Management
The Camera Management menu allows you to search, register and manage your IP cameras, DVRs and
NVRs. See “3.2 Camera Registration” for more information.
Search (DVR/NVR)
The module will scan the network for all supported DVR/NVR. Select the devices you wish to register
from the search results and press the ‘GET INFO’ button.
‘DETAIL INFO’ allows you to get more information on the device’s streams.
Enter the user ID and password for the devices you are registering.
You can also select which channels to register.
Click ‘APPLY’ to register the device.
Search (CAM)
The module will scan the network for all supported IP cameras automatically. From the results, you can
drag cameras to the viewing channel to assign them to channels.
5. Click the START button to search the camera.
6. Select a camera and while clicking on the camera, drag it to a channel to assign it. If needed,
enter the user ID and password for the device you are registering.
7. Click the CLOSE button to finish the process.
User Manual
[12]
2.4
Finish
Complete the setup of your module by registering your product.
When the setup wizard is completed, click the FINISH button to close the setup wizard.
3.
Operation
3.1
User Log-in
Enter the user ID and password. Use the hint button to check for your password hint if needed.
Note
1) The login window displays permanently until a user logs in with the right user ID and
password.
2) If the module is set as AUTO LOGON, the login process is not necessary. See “4.1.2 User
for more information.
Note
The key in the virtual keyboard includes common words, such as Admin, root, http://,
rtsp://, www., .com, .net, .org etc.
Spot™ Monitoring Module
[13]
3.2
DVR/NVR/CAM Registration
Recorder Connection through the Network
The module will scan the network for all supported DVR/NVR automatically. Select the DVR/NVR you
wish to register from the search results and press the ‘GET INFO’ button to obtain the device’s
streaming profile. ‘DETAIL INFO’ allows you to get more information on the device’s streams. If
necessary, enter the user ID and password for the device you are registering. You can also select which
channels from the DVR/NVR you wish to register. Click ‘APPLY’ to register the device.
Camera Connection through the Network
1. Click the START button to search the camera. The module will search the network for
cameras and display all results in the table on the right.
2. Select the camera in the list and drag and drop it to the channel you want to assign to the
camera. (While moving, the mouse pointer is changed to ).
3. Click the CLOSE button to save the registration.
Add DVR/NVR Manually
If a user wants to connect to DVR/NVR in a different network, DVR/NVR can be added manually using
the ADD DVR/NVR MANUALLY button.
1. Click the SEARCH button to open the camera property window.
User Manual
[14]
2. Select channel number to register.
3. Input necessary information with button and click the GET INFO button to get streams
information.
4. Select the channel to register.
5. Click the APPLY button to register DVR/NVR.
Manually add Cameras
If a user wants to connect to an IP camera in a different network, the cameras can be added
manually using the ADD CAMERAS MANUALLY button.
1. Click the ADD CAMERAS MANUALLY button to open the camera property window.
2. Select channel number to register.
3. Select protocol (ONVIF, RTSP, FOCUS and VHT) of the camera. Registration is available with
one of the following. IP Address, RTSP URL or ONVIF URL
4. Input necessary information with button and click the GET STREAM button to get streams
information.
5. Click the APPLY button to register the camera.
Adding a recorder or camera using RTSP
1. Click on the ADD CAMERAS MANUALLY button.
2. Enter the DVR’s user ID and password.
3. Select which channel you want to add to the Spot Monitoring Module.
4. Under Protocol, select RTSP instead of ONVIF (default).
5. Enter the DVR’s model and brand names (optional).
6. Enter the DVR’s RTSP URL in the first RTSP field.
a. To add DW’s VMAX® A1 DVR, the RTSP URL should be as follow:
rtsp://xxx.xxx.xxx.xxx:port/rtsp/unicast/live/profile-x
For example: rtsp://192.168.1.100:80/rtsp/unicast/live/profile-1
7. Enter the devices IP address: xxx.xxx.xxx.xxx.
8. Port: Use the device’s web port (default value is 80).
9. Profile-x: Enter the channel number you want to add.
10. Press the APPLY button to save changes.
Spot™ Monitoring Module
[15]
3.3
Deleting Devices
1. Click the delete ( ) button for deleting each DVR/NVR or camera.
2. Click the DELETE PAGE for deleting devices on the same page and click the DELETE ALL for
deleting all devices.
3.4
Live Display Mode
Channel Selection
The live image can be seen by easy button operation after power-up. The images can be seen in 1, 4, 9
and 16 screen splits (some split options may not be available according to the module’s number of
channels). Whenever the screen display mode button ( ) on the toolbar is clicked, the
screen will change to display the next channel or sequence of channels.
To switch from a multi-channel view to a single camera, click on the selected channel. To return to the
previous screen mode, click on the left mouse button again.
“VIDEO LOSS” is shown on the display screen when no camera is connected or disconnects suddenly.
When a camera is disconnected, a warning sound shall be generated depending on the system setting.
Admin users can set different levels of authorization for each user, granting them specific access to
specific channels. If a certain user is not authorized to view a channel, no image is shown on the display
screen as below.
User Manual
[16]
Icons
The Spot Monitoring Module shows the channel’s current status based on the settings in the DVR or
NVR.
Icons at the right-upper corner on each
channel screen
Icons at the right-bottom corner on fullscreen
Continuous Recording
No HDD detected
Motion Detection Recording
Emergency Recording is in use
Sensor Activated Recording
PTZ is enabled
Continuous + Motion Alarm
Recording
Warning for exceeding the set
temperature
Continuous + Sensor Activated
Recording
Sequence mode is enabled
Motion Detection + Sensor
Activated Recording
Digital zoom is enabled
Sensor Activated
Motion Detected
Audio Channel
PTZ Camera
Note
If you cannot find any recording icon in the right corner of the screen, then the system is not
recording. Check the recording schedule or camera in the main setup menu.
Pop-up Menu
Users can click the right button of the mouse to pop up sub-menu as below. If the user wants to
control a specific channel, put the mouse cursor on that channel and then click the right button.
Display Mode
Users can change the screen display mode from the available split options.
Change Next CH
View the next channel or next group of cameras in the current split
mode.
Sequence
When “SEQUENCE” is selected, icon will appear on the right-
bottom corner of the screen. The display screen will be sequentially
changed.
Digital Zoom
Digital Zoom is available in a single-channel view only. When
“ZOOM” is selected, icon will appear on the bottom-right
corner of the screen and digital zoom control is available.
To zoom in, drag the mouse’s cursor on the desired area to create
a zoom box. You can also control zoom-in and zoom-out by mouse scrolling the mouse’s
wheel up and down. Once the image is zoomed-in, the user can move the zoom area by
clicking on the edge of the square and dragging it.
Spot™ Monitoring Module
[17]
To exit from the zoom mode, click the right and select “ZOOM EXITon the menu.
PTZ
Enable PTZ mode. (Please refer to “3.6 PTZ Operation” for detail.) The available PTZ options
depend on the camera’s ONVIF integration. See the camera’s manual for more information.
Freeze
Freeze the current live view. System clock (date/time information) will continue running at the
bottom of the screen. Select “FREEZE” again to resume the live view.
Camera Setup
View the setup camera menu.
Users can setup resolution, frame, etc. The available options depend on the camera’s ONVIF
integration. See the camera’s manual for more information.
1. Click the GET STREAM button and get the current camera status.
2. Click the CAMERA INFO button to check the camera’s information such as model name, IP
address, port, MAC Address, etc.
3. MAINTENANCE User can camera reset, reboot, firmware upgrade and setup to use the live
buffering function on NVR.
Reset
Soft Reset: Reset camera settings except for basic network settings like IP address,
subnet and gateway or DHCP settings.
Hard Reset: Reset all camera settings (factory reset).
Reboot
- Reboot the camera
Scheduled Reboot: Set the schedule to reboot the camera
F/W Upgrade
: Upgrade the camera firmware
User Manual
[18]
Network
: Set the camera network setting.
System Status
See the system status, including information on the network condition, the number of clients
currently connected to the module, etc. A green line means the connection is live and working.
Menu
Open the main menu setup screen.
Spot™ Monitoring Module
[19]
4.
Setting
The general setting structure consists of “System”, “Monitoring”, and “Network”. Each Setup menu
consists of sub-menus and additional categories.
Main Classification
Sub Classification
SYSTEM
INFORMATION
USER
DI SP LAY
SETTINGS
MONITORING
REGISTRATION
NETWORK
NETWORK
DDNS
To access the setup menu, click the button in the menu bar or right-click anywhere on the
screen and select the Setup Menu.
User Manual
[20]
4.1
System
Information
Site Name
Enter a site name to differentiate the module from other sites.
Date/Time
Using the available options, manually adjust the date and time, select the display mode for the time
and the date, and select the appropriate time zone. If applicable, check the ‘USE DST’ box.
There are four types of time sync modes:
Server Mode: The operating module is set as a Time Sync Server, which can synchronize the
time to another module (s) connected over the same network.
Client Mode: Input the IP address of a designated module or PC running Remote Software as
a Time Sync Server in “SYNC SERVER”. The modules time clock will be synchronized with
the server by interval time set in “TIME SYNC CYCLE”.
NTP Mode: “pool.ntp.org” is the recommended NTP Server. To activate, set the TIME ZONE of
your local area and then click the SYNC NOW button.
GPS Mode: Connect USB type GPS device and click the SYNC NOW button.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Digital Watchdog Spot DW-HDSPOTMOD16 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI