User Manual
T8 LED Lamp
Always have a qualied electrician to do your electrical work!
Switch o power before starting the installation!
Instructions for mounting:
Schematic steps for removing a uorescent lamp and inserting a double-capped LED lamp
Installation instructions
This lamp is designed for general lighting service (excluding eg.explosive atmospheres)
This LED tube is compatible with Magnetic ballast only.
This lamp is not suitable for use in emergency light ttings designed for double-capped uorescent lamps.
Do not use this product in outdoor areas.
For dry locations only - not for use where exposed to the weather.
※ The overall energy eciency and light distribution of installed lamps are determined by the design of the installation.
※ Existing power factor compensation capacitors worsen the power factor, but can remain within the light tting.
Notice:
Environment: 10°C to +30°C ,<95% humidity ,no guarantee for water proof
1200mm L-Tube suitable for G13 Base Socket
Replacement: 1200mm 16.5W/19.0W replace uorescent lamp 36.0W
Packing details: LED tube, LED Starter, User manual
Any modication of the light tting when installing the LED lamps is not permitted.
Please do not install this Magnetic ballast compatible LED tube using a glow starter.
Please do not install this Magnetic ballast compatible LED tube using a direct connection to an AC source.
Please do not install this Magnetic ballast compatible LED tube using another independent LED driver.
Please do not replace with a dierent type of LED tube! Risk of electrical shock!
Please use only for a single lamp (do not install over a double lamp and above).
Series connection is not permitted when installing this product.
Do not use this product in outdoor areas.
For dry locations only - not for use where exposed to the weather.
Turn o power before installing or replacing lamp.
Do not touch this product with wet hands.
Do not look directly at the lamp when being used.
Do not use in totally enclosed xtures.
Do not disassemble, repair or alter in any way.
Warning:
1
2
3
4
5
6
7
8
(1) Switch o electricity.
(2) and (3) Remove the conventional lamp.
(4) and (5) Replace the old starter with the LED tube starter.
(6) Insert the LED lamp into the lamp holder.
(7) Secure it in position by turning the lamp 90˚.
(8) Switch on electricity.
EL
S
p.f.correction capacitor
October 2013 – Version 2
The installation date must be documented to make a warranty claim.
The Samsung Electronics guarantees a product life-time of 3 years after the purchase date.
If you do not have a receipt (or invoice) the warranty starts from the production date.
The Samsung Electronics guarantee does not apply to failures caused by abnormal use.
In such circumstances all service and repair costs must be paid for by the customer.
The LED tube starter is a consumable, which can be purchased from your dealer.
xy denotation : xy can be A-Z, standing for national/regional abbreviations eg. EU, CN, etc.
EU – European Union
Warranty:
Ballast Information:(One lamp)
SI-L8R17212Cxy
SI-L8T17212Cxy
SI-L8V17212Cxy
SI-L8R19112Cxy
SI-L8T19112Cxy
SI-L8V19112Cxy
D28 x L1213.6mm max
D28 x L1213.6mm max
D28 x L1213.6mm max
D28 x L1213.6mm max
D28 x L1213.6mm max
D28 x L1213.6mm max
5000K
Power consumption Size CCTModel Name
4000K
3000K
16.5W
16.5W
16.5W
19.0W
19.0W
19.0W
5000K
4000K
3000K
Maker Model Name
Helvar
Helvar
Helvar
ABB
ABB
Vossloh & Schwabe
TRIDONIC
Simens
L36A-K
L36TL4
L36A-T
VVG 36-120 CF-30
36-120 CF-55
L36I.342
EC 36-1 C501K
VVG 5LZ 363