ABB Welcome M25102 CR Series User manual

  • Hello! I am an AI chatbot trained to assist you with the ABB Welcome M25102 CR Series User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
VER:1.1 10.09.2015
ABB-Welcome
Pos: 2 /DinA4 - A nleitungen Onlin e/Inhalt/KNX/D oorEntry/832 20-AP-xxx/Ti telblatt - 83 220-AP-xxx - ABB @ 19\ mod_1323249 806476_15.doc x @ 111084 @ @ 1
M25102xC
M25102xA-x-
M25102xPx.
M25102xK-x.
M25102xCR.
5102xDN
5101xPx
Outdoor station
Module family
=== Ende der List e für Textmarke Cover ===
Audio module
Audio module
1/2 button
Audio module
2/4 button
Nameplate module
Round pushbutton
2 button
Camera module
Round pushbutton
1 button
Round pushbutton
3 button
Pushbutton
3/6 button
Pushbutton
4/8 button
Round pushbutton
1 button, with NFC/IC
Round pushbutton
2 button, with NFC/IC
Round pushbutton
3 button, with NFC/IC
Keypad (3 versions)
Stainless steel
Aluminum
White
ABB-Welcome
|
3
Pos: 4 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/In haltsverzeichnis ( --> Für alle Dokumente <--)/Inhalts verzeichnis @ 19\mod_1320 649044386_1 5.docx @ 109653 @ @ 1
1 Safety ............................................................................................................ 5
2 Intended use .................................................................................................. 5
3 Environment .................................................................................................. 5
3.1 ABB devices ................................................................................. 5
4 Terminal description ...................................................................................... 7
4.1 Audio module ................................................................................ 7
4.1.1 Lock connected with terminals 3 and 4 ....................................... 13
4.2 Camera module .......................................................................... 14
4.2.1 Analog camera connected with terminal 1 .................................. 15
4.2.2 Detached camera connection ..................................................... 16
4.3 Round pushbutton module .......................................................... 17
4.4 Pushbutton module ..................................................................... 19
4.5 Keypad module ........................................................................... 21
4.6 Display and card reader module ................................................. 23
4.7 Nameplate module ..................................................................... 25
5 Operation ..................................................................................................... 27
5.1 Pushbutton outdoor station ......................................................... 27
5.1.1 Addressing .................................................................................. 27
5.1.2 Setting the language for the voice messages (if the audio module
has a speech synthesis function) ................................................ 31
5.2 Pushbutton outdoor station with display module ......................... 34
5.3 Pushbutton outdoor station with keypad module ........................ 36
5.4 Round pushbutton outdoor station with IC/NFC ......................... 38
5.5 Keypad outdoor station ............................................................... 42
5.5.1 Call a resident (3 types) .............................................................. 42
5.5.2 Call the guard unit ...................................................................... 44
5.5.3 If an indoor station is in “leave home mode” ............................... 44
5.5.4 If a guard unit is in "intercept mode" ........................................... 45
5.5.5 System settings .......................................................................... 46
5.6 Keypad outdoor station without display (camera + audio +
keypad) ....................................................................................... 56
5.6.1 Calling a resident by inputting physical address ......................... 56
5.6.2 Call guard unit ............................................................................ 56
5.6.3 System settings .......................................................................... 56
6 Advanced configuration ............................................................................... 58
7 Technical data ............................................................................................. 59
8 Mounting/installation .................................................................................... 60
ABB-Welcome
|
4
8.1 Requirements for the electrician ................................................. 60
8.2 General installation instructions .................................................. 61
8.3 Mounting ..................................................................................... 62
=== Ende der List e für Textmarke TOC ===
ABB-Welcome
Safety
|
5
Pos: 6 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Übers chriften (--> Für alle Dokum ente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_13 02612791790 _15.docx @ 10335 7 @ 1 @ 1
1 Safety
Pos: 7 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Sich erheit (--> Für alle Doku mente <--)/Warnhin weise/Sicherheit - 2 30 V @ 18\m od_1302606816 750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
Work on the 100-240V supply system may only be performed by
authorized electricians!
Disconnect the mains power supply prior to installation and/or
disassembly!
Pos: 8 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Übers chriften (--> Für alle Dokum ente <--)/1. Ebene/A - F/Bestim mungsgemäßer Gebrauch @ 18\mo d_13027633213 16_15.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /DinA4 - A nleitungen Onlin e/Inhalt/KNX/D oorEntry/832 20-AP-xxx/B estimmungsg emaesser Ge brauch - 83220-AP-xxx- 500 @ 20\mod_1 32456116869 9_15.docx @ 1 12728 @ @ 1
The outdoor station is an integral part of the ABB-Welcome door entry system and
operates exclusively with components from this system. The device must only be used
with suitable ABB flush-mounted installation sockets and rain hood.
Pos: 10 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Übersc hriften (--> Für alle Doku mente <--)/1. Ebene/U - Z/Umwelt @ 18\mod_1302 614158967_1 5.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 11 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/U mwelt (--> Für alle Dokumente <--)/Hi nweise/Hi nweis - Umwelt - Hi nweis Elektrog eräte @ 18\mod_1302 763973434_1 5.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
household waste.
The device contains valuable raw materials that can be recycled.
Therefore, dispose of the device at the appropriate collecting
facility.
Pos: 12 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/2./ABB G eraete @ 19\m od_13231628438 32_15.docx @ 110875 @ 2 @ 1
3.1 ABB devices
Pos: 13 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/U mwelt (--> Für alle Dokumente <--)/Hi nweise/Hi nweis - Umwelt - A BB Elektrogeräte @ 19\ mod_13231627 45839_15.doc x @ 110867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packing materials and electric devices and their
components via an authorized collection facility or disposal company.
ABB-Welcome
Environment
|
6
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)
ABB-Welcome
Terminal description
|
7
4 Terminal description
4.1 Audio module
No.
Function
1
LED flashes slowly, indicating a call has been established
LED flashes fast, indicating that the system is busy
2
LED illuminates, indicating possible communication.
3
LED illuminates, indicating the door is unlocked
4
Call pushbuttons
ABB-Welcome
Terminal description
|
8
No.
Functions
1
Connector for camera module
2
Connector for device software update
3
Plug-in clamps (COM-NC-NO) for floating output, door opener (30VAC/DC
1A)
4
Plug-in clamps (Lock-GND) for door opener (18V 4A impulsive, 250 mA
holding)
5
Plug-in clamps (DC-GND) for additional power supply
6
Plug-in clamps (a-b) for bus connection
7
Connector for induction loop module
8
Connector for next module
9
Connector for exit push button
10
Connector for sensor for checking the door status
11
Rotary switch for setting the address of OS (1-9)
12
Set feedback tones for push buttons and for outdoor station when making a
call: ON/OFF
13
Configure push buttons in a single column or double column mode (ON=
double column; OFF= single column)
It only affects the bar pushbutton, not the round pushbutton.
14
Configure functions of the 1st/2nd pushbuttons.
3->OFF, 4->OFF=call indoor station/call indoor station
3->ON, 4->OFF=switch on lighting/call indoor station
ABB-Welcome
Terminal description
|
9
3->OFF, 4->ON=call guard unit/call indoor station
3->ON, 4->ON=switch on lighting/call guard unit
15
Adjust the loudspeaker volume.
16
*Adjust the door lock release time, 1-10s (available for the
lock connected with the default lock)
ABB-Welcome
Terminal description
|
10
*Default lock (1st lock): Released by “Unlockbutton of the indoor station. Factory setting is
LOCK-GND.
2nd lock: Released by programmable button1” of the indoor station. Factory setting is COM-
NC-NO.
1
ABB-Welcome
Terminal description
|
11
Change default lock
Default lock can be set at either "Lock-GND" or "NO-NC-COM"
Short circuit the "Exit" two terminals for 3s to enter the setting mode
(3 LED flashes green to show the setting mode for aluminum outdoor station)
(prompt tone di for stainless outdoor station)
Tones for indication:
Lock 1 (LOCK-GND) = default lock
Lock 2 (NC-NO-COM) = default lock
Set outdoor station address ="0"
30s overtime to save the setting and exit the programming mode
Short-circuit Exit terminal on outdoor station to switch the default lock
ABB-Welcome
Terminal description
|
12
Set the lock time of the default lock
Set the time by the potentiometer, from 1-10s
Set the lock time of the 2nd lock
Short circuit the DS two terminals for 3s to enter the setting mode
(3 LED flashes green to show the setting mode for aluminum outdoor station)
(Prompt tone di for stainless outdoor station)
Set outdoor station address ="0"
Record the time for 1st lock
Then set the time for 2nd-Lock from 1-10s
30s overtime to save the setting and exit the programming mode
At last set the time back for 1st-Lock
Recover the time to the original time for 1st lock
ABB-Welcome
Terminal description
|
13
4.1.1 Lock connected with terminals 3 and 4
ABB-Welcome
Terminal description
|
14
4.2 Camera module
No.
Functions
1
Connector for additional analog camera
2
Connector for audio module
3
Jumper for setting the video format: PAL /NTSC
4
Adjust the camera view area
ABB-Welcome
Terminal description
|
15
4.2.1 Analog camera connected with terminal 1
All the cameras with the video output of 1Vp-p 75Ω ,CVBS (composite video broadcast signal)
can be connected with the camera module.
Generally, the transmission distance from the analog camera to the outdoor station can reach
up to 50 meters by coax cables or about 10 meters by other types of cables.
Two types of connections:
Option 1: The analog camera is powered on all the time
Option 2: The analog camera is powered on only during working hours
ABB-Welcome
Terminal description
|
16
4.2.2 Detached camera connection
Camera module can be used as a detached camera. Wiring is shown below.
3 pairs 2-wire bus
together
Max:10 metres
ABB-Welcome
Terminal description
|
17
4.3 Round pushbutton module
No.
Functions
1
Program button
2
Connector for previous module
3
Connector for device software update
4
Connector for Wiegand output.
Default format is 26 bits, it can also be extended to 34 bits.
5
Connector for next module
1
2
3
4
5
2
ABB-Welcome
Terminal description
|
18
No.
Functions
1
Regardless of the structure of the pushbutton module, button numbers
are listed from top to bottom.
2
Lighting switch/call guard unit function is always assigned to the 1st/2nd
button, which is set by audio module.
3
User names can be printed by using the labellling tool of the ABB-Welcome
configuration software.
4
The round pushbutton module with NFC/IC card reader supports the
NFC/IC card. A mobile phone with NFC function is acceptable. (“Door
OpenAPP required.)
ABB-Welcome
Terminal description
|
19
4.4 Pushbutton module
No.
Functions
1
Connector for previous module
2
Connector for next module
No.
Functions
1
Regardless of the structure of the pushbutton module, the button numbers
are listed from top to bottom and from left to right (in the double column
mode.)
ABB-Welcome
Terminal description
|
20
2
Lighting switch / call guard unit function is always assigned to the 1st/2nd
button.
3
User names can be printed by the using the labelling tool of the ABB-
Welcome configuration software.
/