Xt lIte™ Panel
MODEL XTL
INSTALLATION GUIDE
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.•
Increase the separation between the equipment and receiver.•
Connect the equipment into an outlet on a circuit different from that to which the receiver is •
connected.
Consult the dealer or an experienced radio/TV technician for help.•
Changesormodicationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe
user’s authority to operate the equipment.
This device has been designed to operate with the integrated PCB antenna having a maximum gain of 1.8
dB. Antennas having a gain greater than 1.8 dB are strictly prohibited for use with this device. The required
antenna impedance is 50 ohms.
If necessary, the installer should consult the dealer or an experienced radio/television technician
foradditionalsuggestions.Theinstallermayndthefollowingbooklet,preparedbytheFederal
Communications Commission, helpful:
“How to identify and Resolve Radio-TV Interference Problems.”
ThisbookletisavailablefromtheU.S.GovernmentPrintingOfce,WashingtonD.C.20402
StockNo.004-000-00345-4
©2010DigitalMonitoringProducts,Inc.
InformationfurnishedbyDMPisbelievedtobeaccurateandreliable.
This information is subject to change without notice.
XTL Installation Guide Digital Monitoring Products
i
table of Contents
Panel Specications
1.1 Power Supply .........................................1
1.2 Communication .......................................1
1.3 Keypads .................................................1
1.4 Number of Zones ....................................1
1.5 EnclosureSpecications ..........................1
Introduction
2.1 SystemCongurations .............................2
2.2 Caution Notes .........................................2
2.3 Compliance Instructions ..........................2
System Components
3.1 Accessory Devices ...................................3
Installation
4.1 MountingtheEnclosure ...........................4
Primary Power Supply
5.1 DC Input ................................................4
Secondary Power Supply
6.1 Standby Battery ......................................5
6.2 Replacement ..........................................5
6.3 Battery Supervision .................................5
LED Operation
7.1 BacklitLogo ............................................6
Reset Button
8.1 Description .............................................6
Programming Connection
9.1 ProgrammingConnection ........................6
On-Board 1100 Series Wireless
10.1 Wireless Antenna ...................................6
10.2 LED Operation ........................................6
Wireless Keypads
11.1 MountingKeypads ..................................7
11.2 Wireless Keypad Association ....................7
11.3 ExistingKeypadConrmation ...................7
Wireless Zones
12.1 Description .............................................7
Flash Load Button
13.1 Description ............................................8
Listed Compliance Specications
14.1 Introduction ...........................................9
14.2 UseMarking ...........................................9
14.3 NFPA 72 .................................................9
14.4 Types Of Service .....................................9
14.5 Bypass Reports .......................................9
14.6 Battery Standby ......................................9
Digital Monitoring Products XTL Installation Guide
ii
table of Contents
Household Burglar-Alarm System Units
ANSI/UL 1023
15.1 Bell Cutoff ..............................................9
15.2 Entry Delay ............................................9
15.3 Exit Delay ...............................................9
15.4 Wireless External Contact ........................9
15.5 Wireless Supervision Time .......................9
15.6 Wireless Audible Annunciation .................9
15.7 Panel location .........................................9
15.8 Test Frequency .......................................9
Central Station Burglar Alarm Units
ANSI/UL 1610
16.1 Standard Line Security ..........................10
16.2 Remote Disarm .....................................10
16.3 Central Station ......................................10
Household Fire Warning System
ANSI/UL 985 NFPA 72 Specications
17.1 BellOutputDenition ............................10
17.2 HouseholdSystem ................................10
17.3 Wireless External Contact ......................10
17.4 Wireless Supervision Time .....................10
17.5 WirelessFireVerication ........................10
17.6 Battery Standby ....................................10
17.7 Test Frequency .....................................10
False Alarm Reduction Programmable Options
ANSI/SIA CP-01-2007
18.1 ShippingDefaultsandRecommendedProgramming11
18.2 Entry Delay ..........................................12
18.3 Local Bell .............................................12
18.4 Minimum Installation Requirements ........12
Revisions to This Document
Listings and Approvals
XTL Installation Guide Digital Monitoring Products
1
Panel sPeCIfICatIons
Panel Specications
1.1 Power Supply
Input: 12VDC
StandbyBattery: 3.7VDCLithium
All circuits inherent power limited
1.2 Communication
Built-inCellularcommunicationtoDMPModelSCS-1RReceivers.CellularServiceisrequiredbeforeusing
theXTLforsignaltransmission.TheXTLpanelcomeswithaSIMcardreadyforactivationwithSecureCom
Wireless,LLC.Moreinformationisavailableatwww.securecomwireless.com.
1.3 Keypads
Youcanconnectupto4alphanumeric9000Serieswirelesskeypads.
1.4 Number of Zones
XTLhas28wirelessinitiatingzonesnumbered1-28•
Zonenumbers31to34and41to44cansupport1100SeriesKeyFobsorDMPwirelessoutputmodules•
1.5 Enclosure Specications
TheXTLpanelshipsinaplasticenclosurewithauser’sguideandprogrammingsheet.
Size Color
5.58”Wx3.75”Hx1”D White(W)
Digital Monitoring Products XTL Installation Guide
2
IntroduCtIon
Introduction
2.1 System Congurations
The panel can be programmed to operate as any of the following system types:
• All/Perimetersystemthatprovidesoneperimeterareaandoneinteriorarea
• Home/Sleep/Awaysystemthatprovidesoneperimeter,oneinterior,andonebedroomarea.The
bedroom area provides for any protection devices the user wants disarmed during their sleeping hours
and armed in the Away mode.
• Sixareasystemthatprovidesareasofprotectionthatcanbeindependentlyarmedordisarmed.
2.2 Caution Notes
Throughoutthisguideyouwillseecautionnotescontaininginformationyouneedtoknowwheninstalling
thepanel.Thesecautionsareindicatedwithayieldsign.Wheneveryouseeacautionnote,makesureyou
completely read and understand its information. Failing to follow the caution note can cause damage to the
equipment or improper operation of one or more components in the system.
2.3 Compliance Instructions
ForapplicationsthatmustconformtoalocalauthoritiesinstallationstandardoraNationalRecognized
TestingLaboratorycerticatedsystem,pleaseseetheListedComplianceSpecicationssectionneartheend
of this guide for additional instructions.
XTL Installation Guide Digital Monitoring Products
3
system ComPonents
System Components
3.1 Accessory Devices
DMP Two-Way Wireless Devices
1100R Repeater Provides additional range for wireless devices.
1101UniversalTransmitter Provides both internal and external contacts that may be used at the same time to yield two
individualreportingzonesfromonewirelesstransmitter.
1102UniversalTransmitter Provides one external contact.
1103UniversalTransmitter Provides both and internal and external contacts that may be used at the same time to
yieldtwoindividualreportingzonesfromonewirelesstransmitter.RequiresEOLresistorfor
external contact.
1105UniversalTransmitter Provides both internal and external contacts that may be used at the same time to yield two
individualreportingzonesfromonewirelesstransmitter.
*1114Four-ZoneExpander ProvidesfourwirelesszoneswithEOLresisters.
*1116RelayOutput Provides one Form C relay.
*1117LEDAnnunciator Provides a visual system status indicator.
*1119DoorSounder Provides a battery operated sounder
*1121PIRMotionDetector Provides motion detection with pet immunity.
1125PIRMotionDetector
Providesmultiplelenscongurations,dualcoverageareaselection,andsensitivityadjustments.
*1126C/*1126R/*1126WPIR
MotionDetector
CeilingmountmotiondetectorwithpanelprogrammablesensitivityandDisarm/Disable
functionality.
1127C/1127WPIRMotion
Detector
WallmountmotiondetectorwithpanelprogrammablesensitivityandDisarm/Disable
functionality.
*1129GlassbreakDetector Detectstheshatteringofframedglassmountedinanoutsidewallandprovidesfull-pattern
coverage and false-alarm immunity.
*1131RecessedContact
Provides concealed protection for doors, windows or other applications.
1135Siren Provides a battery operated siren
*1139BillTrap Providesasilentalarmoptionforretailandbankingcashdrawers.
1142BCTwo-buttonPanicBelt
Clip Transmitter
Provides portable two-button panic operation.
1142Two-buttonPanicTransmitter
Provides permanently mounted under-the-counter two-button panic operation.
*1145(Four-Button)
*1146(Two-Button)
*1147(One-Button)
KeyFobtransmittersdesignedtoclipontoakeyringorlanyard.
1161ResidentialSmokeDetector Residentialsmokedetectorwithsounder.
1162ResidentialSmokeDetector Residentialsmoke/heatdetectorwithsounderandxedrate-of-riseheatdetector.
Keypads
LCDkeypads Allowsyoutocontrolthepanelfromvariousremotelocationsusing9000SeriesWireless
Keypads.
* These devices have not been investigated and shall not be used in listed installations
Digital Monitoring Products XTL Installation Guide
4
InstallatIon
Installation
4.1 Mounting the Enclosure
TheenclosurefortheXTLpanelmustbemountedusingtheprovided#6screwsinthefourmountingholes
showninFigure2.Mounttheenclosureinasecure,dryplacetoprotectthepanelfromdamagedueto
tampering or the elements. It is not necessary to remove the PCB when installing the enclosure.
65555
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTL
Mounting Hole
Locations
TX RF RX
Figure 2: Mounting Hole Locations
Primary Power Supply
5.1 DC Input
MounttheXTLpanelnearawalloutletfortheModel372-500plug-inDCpowersupply.Inadditionto
poweringthepanel,theDCplug-inpowersupplyalsochargestheback-upbattery.The372-500mustbe
locatedwithin100feetofthepanelusing22AWGwireor250feetusing18AWGwire.Usethefollowing
steps to connect the plug-in power supply:
1.Using18or22AWGwire,connectthepanelPWR(J2)rstterminal(+)tothepositiveterminalon
the power supply.
2.ConnectthepanelPWR(J2)secondterminal(-)tothenegativeterminalonthepowersupply.
3.Plugthepowersupplyintoa110VoltACdedicatedoutletnotcontrolledbyaswitch.
65555
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTL
Wire Exits for DC
Power Supply
+
-
TX RF RX
Model 372-500
DC Plug-in
Power
Supply
Use 18 AWG or 22 AWG for
Power Supply connection
+
_
Figure 3: DC Power Supply Connection
XTL Installation Guide Digital Monitoring Products
5
InstallatIon
Secondary Power Supply
6.1 Standby Battery
TheXTLrechargeablebatteryisusedtoprovide24hoursofbackupbatterypowerwhenDCpowerisnot
available.ThebatteryisintendedforbackuppoweronlyandnottooperatetheXTLpanelonadailybasis.
Ifthebatteryislow,ornotpluggedintotheJ1batteryconnector,alowbatteryconditionisindicatedbythe
XTLpanel.
Note:IfremovingtheXTLpanelfromservice,disconnectthebackupbatteryfromtheXTLconnector.
6.2 Replacement
UsethefollowingstepstoreplacetheXTLstandbybattery.DMPrecommendsreplacingthebatteryevery3
years under normal use.
Top PCB Snaps
Bottom PCB Snaps
Battery
connector
3.7V
Rechargeable
Battery
Figure 4: Standby Battery Replacement
1. Unplugthebatteryconnector(J1)fromtheXTLpanel.
2. LoosenthetopPCBsnaps.
3. LeanthepanelPCBforwardandliftoutfromthebottomPCBsnaps.
4. Removeandproperlydisposeoftheusedbattery.
Caution:Riskofre,explosion,andburns.Donotdisassemble,heatabove212°F(100°C),
or incinerate. Properly dispose of used batteries.
5. PlacethenewbatteryintotheXTLhousingbasewiththebatterywiresdirectedtowardthe
bottomrightcorner.SeeFigure4.
6. SettheXTLPCBintothebottomsnapsandpressintothetopsnapstosecureinplace.
7. Plugthebatteryintothepanelconnector(J1).
6.3 Battery Supervision
ThepanelteststhebatteryonceeveryhourwhenDCpowerispresent.Thistestoccurs15minutespast
eachhourandlastsforveseconds.Aloadisplacedonthebatteryandifthebatteryvoltageislow,alow
batteryisdetected.IfDCpowerhasfailed,alowbatteryisdetectedanytimethebatteryvoltagefalls
below3.7V.
Digital Monitoring Products XTL Installation Guide
6
InstallatIon
LED Operation
7.1 Backlit Logo
ThebacklitlogoindicatesthePowerandArmedstatusofthepanel.Dependingontheoperation,theLED
displaysinRedorGreenaslistedinthetable.
Color and Activity Operation
GreenSteady PanelDisarmed,ACPowerOK,BatteryOK
GreenBlinking PanelDisarmed,ACPowerOK,BatteryFault
NoLight PanelDisarmed,ACPowerFault,BatteryOK
RedSteady PanelArmed,ACPowerOK,BatteryOK
Red/GreenAlternate PanelArmed,ACPowerOK,BatteryFault
RedBlinking PanelArmed,ACPowerFault,BatteryOK
Reset Button
8.1 Description
Theresetbutton(S1)islocatedontherightsideofthecircuitboardandisusedtoresettheXTL
microprocessor.Toresetthepanelwhenrstinstallingthesystem,presstheresetbuttonafterapplying
power to the panel.
To reset the panel while the system is operational, for example, prior to reprogramming, press the reset
buttonfor1-2secondswithoutpoweringdownthesystem.Afterresettingthepanel,beginprogramming
within30minutes.Ifyouwaitlongerthan30minutes,youmustresetthepanelagain.
Programming Connection
9.1 Programming Connection
Alocking4-pinheader(PROG)isprovidedtoconnectakeypadwhenusingaDMPModel330Programming
Cable.ThisprovidesaquickandeasyconnectionforprogrammingtheXTLpanel.Afterprogrammingis
complete,removethekeypad.
Note:ThePROGheaderdoesnotprovideaKeypadDataBusconnection.
On-Board 1100 Series Wireless
10.1 Wireless Antenna
TheXTLWirelessAntennaisintegratedintothecircuitboard.TheXTLbuilt-inwirelessreceiveroperates
withDMP1100Seriestransmitters.Seesection3.1foralistofaccessorydevices.
10.2 LED Operation
Green (TX):ThegreenLEDasheseverytimethereceivertransmits(32timespersecond).Ifahousecode
isnotprogrammedinthepanel,thepanelisreset,orthepanelispoweredoff,thegreenLEDisoff.Under
normaloperation,thegreenLEDashesconstantlywithnointerruptionorchange.
Yellow (RX):TheyellowLEDasheseverytimethereceiverhearsamessagefromaprogrammedwireless
transmitter.Whenamessageissentbyatransmitter,typicallybypressingorreleasingthetamperswitch,
theyellowLEDshouldashindicatingthatthereceiverreceivedamessagefromthetransmitter.Ifthe
LEDneverashes,thetransmitterisnotgettingthroughtothereceiver.Thiscouldbebecauseofa
misprogrammedserialnumberorthetransmitteristoofaraway.Undernormaloperation,theyellowLED
ashesateverytripofeverywirelesstransmitterandoccasionallywhenthetransmittersperformtheir
periodiccheck-in.ItisnotunusualforthisLEDtostayoffformanyminutesatatimewhennotransmitters
are communicating.
XTL Installation Guide Digital Monitoring Products
7
InstallatIon
Wireless Keypads
11.1 Mounting Keypads
DMPkeypadshaveremovablecoversthatallowthebasetobemountedonawallorotheratsurfaceusing
the screw holes provided on each corner.
11.2 Wireless Keypad Association
Pressingtheresetbutton3timeswithin5secondsenablesthekeypadassociationmode.Foroneminute
thepanellistensforwirelesskeypads.Anykeypadsnotalreadyassociatedwithanotherpanelareaccepted.
Therstkeypaddetectedisassignedtotherstopenkeypadaddress.Keypadsareautomaticallyassigned
addressesbasedupontheorderinwhichtheyaredetected.Amaximumof4keypadsmaybeassociated
with a panel.
11.3 Existing Keypad Conrmation
Duringtheoneminutetimeperiod,thepanelalsoconrmsthatprogrammedkeypadsarestillfunctioning.
Wireless Zones
12.1 Description
XTLpanelsprovide28wirelesszonesnumbered1to28.Thedefaultzonenamesaredescribedbelow.
Zone Number Zone Name Zone Type Area Assignment
1 FRONT DOOR EX PERIM
2 BACK DOOR EX PERIM
3 INTERIOR DOOR NT INT
4 UPSTAIRS DOOR EX PERIM
5 BASEMENT DOOR EX PERIM
6 GARAGE DOOR EX PERIM
7 WAREHOUSE DOOR EX PERIM
8 SHIPPING DOOR EX PERIM
9 BREAKROOM DOOR NT INT
10 STOCKROOM DOOR NT INT
11 FRONT MOTION NT INT
12 BACK MOTION NT INT
13 INTERIOR MOTION NT INT
14 UPSTAIRS MOTION NT INT
15 BASEMENT MOTION NT INT
16 GARAGE MOTION NT INT
17 GLASSBREAK NT INT
18 WATER DETECTOR AUX 1 INT
19 LOW TEMPERATURE AUX 1 INT
20 SMOKE DETECTOR FI
21 FRONT SMOKE FI
22 BACK SMOKE FI
23 INTERIOR SMOKE FI
24 UPSTAIRS SMOKE FI
25 BASEMENT SMOKE FI
26 GARAGE SMOKE FI
27 WAREHOUSE SMOKE FI
28 SHIPPING SMOKE FI
Digital Monitoring Products XTL Installation Guide
8
InstallatIon
Flash Load Button
13.1 Description
TheXTLpanelsoftwarecanbeupdatedviathepanel’sprogramming(PROG)header.Toupdatethepanel
with a new software version, complete the following steps at the protected premise:
1. ConnectaDMP399CablefromtheProgrammingHeadertotheserialportofyourPCoperating
RemoteLinkandcontainingtheXTLRUle.
3. StartRemoteLinkandcreateoropentheXTLcontrolpanelaccountthatmatchesthepaneltobe
updated.
4. SettheConnectionInformationTypetoDirectwithabaudrateof38400andchoosethe
appropriateCOMport.
5. SelectPanel>RemoteUpdate,thenselectthecorrectRUlefortheXTpanelmodel.
6. PressandholdtheLOADbutton(S2),thenpressandreleasetheRESETbutton.
7. ReleasetheLOADbuttonandclick<Update>inRemoteLink.
8. Afterthesoftwareupdateiscompleted,removethe399cableandpresstheRESETbuttonto
resume normal panel operation.
XTL Installation Guide Digital Monitoring Products
9
InstallatIon
Listed Compliance Specications
14.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstalling
theXTLinaccordancewithanyoftheANSI/ULburglarystandards.Additionalspecicationsmayberequired
by a particular standard.
14.2 Use Marking
CommercialCentralStation;HouseholdFireandBurglarWarningSystemControlUnit(Cellular)
14.3 NFPA 72
ThisequipmentshouldbeinstalledinaccordancewithChapter11oftheNationalFireAlarmCode,ANSI/
NFPA72-2002,(NationalFireProtectionAssociation,BatterymarchPark,Quincy,MA02269).Printed
information describing proper installation, operation, testing, maintenance, evacuation planning, and repair
serviceistobeprovidedwiththisequipment.Warning:Owner’sinstructionnotice,nottoberemovedby
anyone except occupant.
14.4 Types Of Service
SuitableforCentralStationStandardLineSecurity.SuitableforHouseholdFireandHouseholdBurglary.Test
weekly.
14.5 Bypass Reports
ThebypassreportsmustbeprogrammedasYESforalllistedburglaryapplications.
14.6 Battery Standby
TheXTLisshippedwithabatteryfor24hourbatterystandbyoperation.
Household Burglar-Alarm System Units
ANSI/UL 1023
15.1 Bell Cutoff
The bell cutoff time cannot be less than four minutes.
15.2 Entry Delay
Themaximumentrydelayusedmustnotbemorethan45seconds.
15.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
15.4 Wireless External Contact
Whenused,theExternalContactof1101or1102mustbeprogrammedNormallyClosed.
15.5 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).
15.6 Wireless Audible Annunciation
TheWirelessAudibleoptionmustbeselectedasDAYforresidentialapplications.
15.7 Panel location
Mountpanelinsideprotectedarea.
15.8 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
Digital Monitoring Products XTL Installation Guide
10
ComPlIanCe
Central Station Burglar Alarm Units
ANSI/UL 1610
16.1 Standard Line Security
StandardLineSecurityisprovidedwhentheCheck-intimeissetto3minutes.Whenprogrammedfor
StandardLineSecurity,ExitTimeRestartisdisabled.
Note:TheSecureComWirelesstextplanselectedforthepanelshouldmatchorexceedtheprogrammed
MonthlyLimitoradditionalcellularchargesmayapply.
16.2 Remote Disarm
REMOTEDISARMmustbeprogrammedasNO.
16.3 Central Station
MESSAGETOTRANSMITprogrammingforzonesmustnotbesettoLOCAL(L).
Household Fire Warning System
ANSI/UL 985 NFPA 72 Specications
17.1 Bell Output Denition
ThebelloutputoftheXTLpanelmustbeprogrammedtooperatesteadyonburglaryalarmsandtemporal
onrealarms.SeetheXTLProgrammingGuide.
17.2 Household System
An alarm sounding device must be installed indoors so that it is clearly heard in all sleeping areas.
17.3 Wireless External Contact
Whenused,theExternalContactof1101or1102mustbeprogrammedNormallyClosed.SeetheXTL
ProgrammingGuide.
17.4 Wireless Supervision Time
TheZoneInformationSupervisionTimemustbe3minutesforredevices.SeetheXTLProgrammingGuide.
17.5 Wireless Fire Verication
Whenused,theModel1161and1162wirelesssmokedetectorsmustnotbeprogrammedasFireVerication
(FV)zonetype.SeetheXTLProgrammingGuide.
17.6 Battery Standby
ForULlistedapplications,thepanelmusthave24hourbatterystandbyoperation.
17.7 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
XTL Installation Guide Digital Monitoring Products
11
ComPlIanCe
False Alarm Reduction Programmable Options ANSI/SIA CP-01-2007
18.1 Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT-1108
SECTION #
REQUIREMENT RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1ExitTime 8.6ExitDelay
Required
(Programmable)
45sec.-250sec.
60
Seconds
60Seconds
4.2.2.2Progress
Annunciation
13.14Prewarn
Address
Allowed
Individualkeypads
may be disabled per
zone
All
keypads
enabled
Allkeypadsenabled
4.2.2.3ExitTime
Restart
8.6ExitDelay RequiredOption
For re-entry during
exit time
Enabled Enabled
4.2.2.5AutoStayArm
onUnvacatedPremises
8.17Occupied
Premise - SeeInstall
Guide
RequiredOption
(exceptfor
remotearming)
OccupiedPremise
NO/YESoption
Enabled
EnabledYes
for Residential
Applications
4.2.4.4ExitTimeand
Progress Annunciation/
Disable-forRemote
Arm
NotAvailableon
Remote Arming
AllowedOption
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1EntryDelay(s) 8.5EntryDelay
Required
(Programmable)
30sec.–240Sec.**
30
Seconds
Atleast30Seconds**
4.2.5.1AbortWindow–
forNon-FireZones
3.3TransmitDelay RequiredOption
Disablebyzoneor
zonetype
Enabled
NTDY
EXZone
Enabled
4.2.5.1AbortWindow
Time–forNon-Fire
Zones
3.3TransmitDelay
Required
(Programmable)
20sec.,30sec.,or
40sec.**
30
Seconds
Atleast20Seconds**
4.2.5.1.2Abort
Annunciation
3.3TransmitDelay RequiredOption
Annunciate that
no alarm was
transmitted
Yes Yes
4.2.5.4.1Cancel
Annunciation
AlwaysEnabled-Not
Programmable
RequiredOption
Annunciate that
a Cancel was
transmitted(S49)
Always
Enabled
Yes
4.2.6.1&4.2.6.2
DuressFeature
UserCode+1=
AmbushCodeNot
Available
AllowedOption
No1+derivativeof
another user code/no
duplicates with other
user codes
Code+1
Always
Disabled
NotProgrammable
4.3.2SwingerShutdown
NotAvailable—
AlwaysOn
Required
Forallnon-re
zones,shutdown
after 1 trip
Always
On
AlwaysOn
4.3.2SwingerShutdown
Disable
13.13SwingerBypass Allowed
For non-police
responsezones
Yes Enabled(allzones)
4.3.3FireAlarm
Verication
13.5ZoneType RequiredOption FV Type Zone No
Yes as required
(unlesssensorscan
selfverify)
* Programming at installation may be subordinate to other listed requirements for the intended application.
**ForlistedInstallations,combinedEntryDelayandTransmitDelayshouldnotexceed1minute.
Digital Monitoring Products XTL Installation Guide
12
ComPlIanCe
False Alarm Reduction Programmable Options ANSI/SIA CP-01-2007
(continued)
18.2 Entry Delay
OnlyuseEntryDelay1.DonotuseEntryDelay2.SeetheXTLProgrammingGuide.
18.3 Local Bell
Allnon-rezonessuchasNight,Day,Exit,Aux1andAux2mustbeprogrammedforlocalbellenabledwith
a bell cutoff time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater. This
doesnotapplytomanuallyoperatedzonetypessuchasPanicandEmergency.
TherequirementsaresupercededbyanyrequirementsforCommercialBurglar,HouseholdFireWarning,or
Household Burglar applications.
18.4 Minimum Installation Requirements
SIACP-01-2007minimumsysteminstallationrequirementsincludeanXTL,an1135WirelessSiren,and
communicationtoanSCS-1Rreceiverplusa9000SeriesWirelesskeypad.
XTL Installation Guide Digital Monitoring Products
13
revIsIons
Revisions to This Document
This section explains the changes that were made to this document during this revision. This section lists
theversion,sectionnumberwithheading,andaquicksummaryofthechange.
Ver. Section Number and Heading Summary of Changes
LT-11051.01©2010DigitalMonitoringProducts,Inc.
800-641-4282
www.dmp.com
MadeintheUSA
INTRUSION•FIRE•ACCESS•NETWORKS
2500NorthPartnershipBoulevard
Springfield,Missouri65803-8877
10045
Listings and Approvals
FCCPart15ID:CCKPC0117
IndustryCanadaID:5251A-PC0117
UnderwritersLaboratories(UL)Listed
ANSI/UL1023 HouseholdBurglar
ANSI/UL985 HouseholdFireWarning
ANSI/UL1610 CentralStationBurglar
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

DMP Electronics CCKPC0117 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI