Siemens SIMATIC ET 200SP HA User manual

Category
Digital & analog I/O modules
Type
User manual
SIMATIC
ET 200SP HA
Digital Input Module DI 8x230VAC
HA (6DL1131-6GF00-0PK0)
Manual
05/2017
A5E39401560-AA
Security information 1
Preface 2
Product overview 3
Wiring 4
Parameters 5
Displays and interrupts 6
Technical specifications 7
Drivers, parameters,
diagnostics messages and
address space A
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified
personnel are those who, based on their training and experience, are capable of identifying risks and avoiding
potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in
this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
A5E39401560-AA
Ⓟ 05/2017 Subject to change
Copyright © Siemens AG 2017.
All rights reserved
Table of contents
1 Security information......................................................................................................................................5
2Preface.........................................................................................................................................................7
3Product overview..........................................................................................................................................9
3.1 Properties of the I/O module DI 8x230VAC HA.......................................................................9
4Wiring.........................................................................................................................................................11
4.1 Pin assignment of the I/O module DI 8x230VAC HA.............................................................11
4.2 Schematic circuit diagram......................................................................................................13
5 Parameters.................................................................................................................................................15
5.1 Parameters of the I/O module DI 8x230VAC HA...................................................................15
5.2 Module/channel parameters...................................................................................................15
5.3 Explanation of the module/channel parameters.....................................................................15
6 Displays and interrupts...............................................................................................................................17
6.1 Status and error displays of the I/O module DI 8x230VAC HA..............................................17
6.2 Interrupts................................................................................................................................18
7 Technical specifications..............................................................................................................................21
A Drivers, parameters, diagnostics messages and address space...............................................................25
A.1 Concept of the driver and diagnostics blocks.........................................................................25
A.2 Parameter assignment...........................................................................................................26
A.3 Parameter assignment and structure of the module/channel parameters.............................27
A.4 Diagnostics messages and maintenance events...................................................................30
A.5 Address space.......................................................................................................................31
Index...........................................................................................................................................................33
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 3
Table of contents
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
4Manual, 05/2017, A5E39401560-AA
Security information 1
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines, and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines and
networks. Systems, machines and components should only be connected to the enterprise
network or the internet if and to the extent necessary and with appropriate security measures
(e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit:
http://www.siemens.com/industrialsecurity.
Siemens’ products and solutions undergo continuous development to make them more secure.
Siemens strongly recommends to apply product updates as soon as available and to always
use the latest product versions. Use of product versions that are no longer supported, and
failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under
http://www.siemens.com/industrialsecurity.
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 5
Security information
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
6Manual, 05/2017, A5E39401560-AA
Preface 2
Validity of the documentation
This device manual describes the DI 8x230VAC HA I/O module with the article number
6DL1131-6GF00-0PK0.
It complements the system manual of the ET 200SP HA Distributed I/O System.
Functions that generally relate to the system are described in this manual.
The information in this device manual and the system/function manuals enables you to put the
ET 200SP HA into operation.
Appendices
The appendices provide information that is relevant for using the ET 200SP HA outside the
PCS 7 environment.
Conventions
Please also observe notes marked as follows:
Note
A note contains important information on the product described in the documentation, on the
handling of the product and on the section of the documentation to which particular attention
should be paid.
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 7
Preface
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
8Manual, 05/2017, A5E39401560-AA
Product overview 3
3.1 Properties of the I/O module DI 8x230VAC HA
View of the module
DIAG MT



DI HA
8x230VAC
7 8
12
34
56
15 16
910
11 12
13 14
C. 6
A.0
C. 2
A.4
D.7
B.1
D. 3
B. 5
C. 6
A.0
C. 2
A.4
D.7
B.1
D. 3
B. 5
DI
N
1P1 1P2
2P1 2P 2
NC
NC
NC
NC
MAX. 10 A
.0 .1
.2 . 3
.4 .5
.6 .7
X2
3 4
V 1.0 .0
CC 42
6DL1131-6GF00-0PK0
Module type and designation Module type color coding
LED for diagnostics Product version
LED for maintenance Function status and firmware version
2D matrix code Color code for selection of the color-coded labels
Wiring diagram Serial number
LEDs for channel status Article number
Figure 3-1 View of DI 8x230VAC HA
Properties
The I/O module has the following technical properties:
8 electrically isolated digital inputs in four groups (A to D) each to two channels
Suitable for connection of switches and 2-wire sensors in accordance with IEC 61131, type
3
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 9
The I/O module supports the following functions:
Firmware update
I&M identification data
Parameter reassignment in RUN
Value status QI
You can configure the I/O module with HW Config and integrate it into your system.
Accessories
The following accessories must be ordered separately:
Labeling strips
Color-coded labels
Reference identification label
Shield connector
Product overview
3.1 Properties of the I/O module DI 8x230VAC HA
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
10 Manual, 05/2017, A5E39401560-AA
Wiring 4
4.1 Pin assignment of the I/O module DI 8x230VAC HA
Terminal blocks
You can operate the I/O module with the following terminal blocks:
6DL1193-6TP00-0DK0, light
6DL1193-6TP00-0BK0, dark
The terminal block is not included in the scope of delivery of the I/O module and must be
ordered separately.
Note
You can find additional information on the configuration in the system manual.
WARNING
Risk of death or serious injury from electric shock!
Prior to working on the system and module, always disconnect them from the power supply.
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 11
General pin assignment
Table 4-1 Pin assignment of the DI 8x230VAC HA
Terminal assignment Terminal assignment Explanations
1DI A.0 2DI B.1 DI X.n: Input signal, channel n
N X.n: Neutral conductor, channel n
NC (Not Connected) The terminals are not connected to the DI
8x230VAC HA. However, the potentials of the power bus are on these
terminals.
The letters A to D indicate the assignment of the electrically isolated
channels to one of the 4 groups, which allow for a different difference
in potential.
7
C.6
8
1
A.0
2
3
C.2
4
5
A.4
6
1P1
NC NC
1P2
2P1
NC NC
2P2
MA X. 10 A
D.7
B.1
D.3
B.5
DI
15
C.6
16
9
A.0
10
11
C.2
12
13
A.4
14
D.7
B.1
D.3
B.5
N
3DI C.2 4DI D.3
5DI A.4 6DI B.5
7DI C.6 8DI D.7
9N A.0 10 N B.1
11 N C.2 12 N D.3
13 N A.4 14 N B.5
15 N C.6 16 N D.7
1P1 NC 1P2 NC
2P1 NC 2P2 NC
2-conductor
/',;Q
1;Q
1
Wiring
4.1 Pin assignment of the I/O module DI 8x230VAC HA
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
12 Manual, 05/2017, A5E39401560-AA
4.2 Schematic circuit diagram
The following figure shows the block diagram of the DI 8x230VAC HA.
ET 200SP HA
Backplane bus
interface
Backplane bus
1
9
8
16
Figure 4-1 Block diagram DI 8x230VAC HA
Wiring
4.2 Schematic circuit diagram
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 13
Wiring
4.2 Schematic circuit diagram
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
14 Manual, 05/2017, A5E39401560-AA
Parameters 5
5.1 Parameters of the I/O module DI 8x230VAC HA
Configuring
You configure the I/O module with PCS 7 V9.0 or higher.
Parameters
You define the functioning of the I/O module via parameters.
See also
Parameter assignment (Page 26)
5.2 Module/channel parameters
Parameters of the DI 8x230VAC HA
You have the following setting options:
Table 5-1 Parameters and their default settings
Parameters Value range Default Parameter reassign‐
ment in RUN
Efficiency range
Channel activated ● Enabled
● Disabled
Enabled Yes Channel
Potential group Use potential group of the
left module
Allow new potential group
Use potential
group of the left
module
No Module
5.3 Explanation of the module/channel parameters
Channel activated
Specifies whether a digital input is activated or deactivated.
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 15
Potential group
A potential group consists of a group of directly adjacent I/O modules within an ET 200SP
station HA, which are supplied via a common supply voltage.
A potential group begins with a light terminal block, via which the required supply voltage is
fed to all I/O modules of the potential group. The light-colored terminal block interrupts the self-
assembling voltage buses to the left neighbor
All other I/O modules of this potential group are plugged into dark terminal blocks. I/O modules
on dark terminal blocks take the potential of self-assembling voltage rail from the left neighbor.
A potential group ends with the dark terminal block, which follows a light terminal block or a
server module in the station configuration.
You can find additional information on the configuration of the potential group in the system
manual
SIMATIC; Distributed I/O System; ET 200SP HA
.
Parameters
5.3 Explanation of the module/channel parameters
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
16 Manual, 05/2017, A5E39401560-AA
Displays and interrupts 6
6.1 Status and error displays of the I/O module DI 8x230VAC HA
LED displays
The following figure shows the LED displays (status and fault displays) of the I/O module.
DI HA
8x230VAC
DIAG M T
78
1DI
N
2
34
5
15
9
11
13
16
10
12
14
C. 6
A.0
C. 2
A.4
D.7
B.1
D. 3
B. 5
C. 6
A.0
C. 2
A.4
D.7
B.1
D. 3
B. 5
6
1P1
NC
NC
1P2
2P1
NC
NC
2P 2
MA X. 10 A
.0 .1
.2 . 3
.4 . 5
.6 .7
V 1.0 .0
CC 42
6DL1131-6GF00- 0PK0
X2
34
DIAG LED (green/red)
MT LED (yellow)
Channel status LED (green)
Figure 6-1 LED displays
Meaning of the LED displays
The following tables show the meaning of the status and fault displays. You can find remedies
for diagnostic messages in the section Diagnostics messages and maintenance events
(Page 30)
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 17
DIAG LED
Table 6-1 Diagnostics display of the DIAG LED
DIAG LED Meaning
Off
The power supply of the ET 200SP HA is disrupted or switched off.
Flashing
Module is not configured.
On
Module is configured, a diagnostics message is not pending.
Flashing
Module is configured, at least one diagnostic message is pending.
MT LED
Table 6-2 Maintenance display of the MT LED
MT LED Meaning
Off
No maintenance required.
On
Maintenance is required, i.e. at least one maintenance event has occurred.
Channel status LED
Table 6-3 Status display of the channel status LED
Channel status
LED
Meaning
Off
Process signal = 0 or channel disabled
On
Process signal = 1 and channel enabled
6.2 Interrupts
The I/O module supports diagnostic interrupts and maintenance messages.
Diagnostics interrupts
The I/O module generates a diagnostic interrupt for the following events:
Parameter assignment error
Channel/component temporarily unavailable
Displays and interrupts
6.2 Interrupts
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
18 Manual, 05/2017, A5E39401560-AA
Retentive memory in carrier module defective
Retentive memory in the terminal block defective
Maintenance messages
The I/O module generates a maintenance message for the following events:
Retentive memory in carrier module defective
Retentive memory in the terminal block defective
Displays and interrupts
6.2 Interrupts
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
Manual, 05/2017, A5E39401560-AA 19
Displays and interrupts
6.2 Interrupts
Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0)
20 Manual, 05/2017, A5E39401560-AA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Siemens SIMATIC ET 200SP HA User manual

Category
Digital & analog I/O modules
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI