MX40 EBL

Panasonic MX40 EBL User guide

  • Hello! I am an AI chatbot trained to assist you with the Panasonic MX40 EBL User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the EBLOne?
    What type of user interface does the EBLOne have?
    Can I perform setup without a computer?
    Is the EBLOne compatible with other Panasonic products?
www.panasonic-re-security.com
Safety innovation, our passion
App based
menu system
An easy-to-navigate
structure featuring a
clear path to all functions
at the top for efcient
task completion.
Installation
Disable Test
Maintenance
Status
Settings
Auto set-up
The EBLOne revolutionizes
commissioning with its
graphic LCD interface,
eliminating the need for a
PC and taking it to the
next level of ease.
EBLOne setup Wizard
Experience the next level
The new innovative EBLOne control unit sets a new standard in one loop re detection systems.
It features a modern and discrete design that will impress architects and end users, combined with
the most intuitive user interface to make installation and maintenance easier than ever before.
Innovative elegance
Its compact size and contemporary design makes it
suitable for a variety of environments, from hotels
to small industries or kindergartens.
Unique user interface
Built up around a color touch screen
with integrated status LEDs,
as the complete user interface.
Built-in
1 or 2*17 Ah
425x310x120mm
230 VAC -5 to +40ºC < 95%4kg IP30
2
Completely new,
but still familiar
Fully compatible with all state-of-the-art Panasonic
loop units and the cutting edge EBLWin.
CONNECTIONS
Outputs for routing equipment
2
24 V programmable voltage output
1
24 V power supply outputs
3
Programmable inputs
2
USB interface (Type C)
1
COM-LOOP
COM-loop
1
SUB-loops
Max. 4
Addresses
253
Isolators
128
Wireless devices
Max. 64
3
EN54-2
EN54-4
Integrated cable guidance
For a clean and tidy installation.
Standard DIN rail
For power supply, Gateway
and 230V connection block.
Battery holders
Use one or two batteries
depending on the load
and back up time needed.
Electronics Module
Consists of the LCD module and PCBA
and is mounted with 4 screws
for easy installation and maintenance.
2
Metal Chassis
Hot galvanized and painted
sheet metal for durability and
elimination of sharp edges.
1
Front Cover
Light weight cover in PC/ABS
with high flammability class (V0).
3
Optional lock
For fire brigade
panel functionality.
Optimised build up...
4
EN54-2
EN54-4
Integrated cable guidance
For a clean and tidy installation.
Standard DIN rail
For power supply, Gateway
and 230V connection block.
Battery holders
Use one or two batteries
depending on the load
and back up time needed.
Electronics Module
Consists of the LCD module and PCBA
and is mounted with 4 screws
for easy installation and maintenance.
2
Metal Chassis
Hot galvanized and painted
sheet metal for durability and
elimination of sharp edges.
1
Front Cover
Light weight cover in PC/ABS
with high flammability class (V0).
3
Optional lock
For fire brigade
panel functionality.
with three main parts
5
Elegance
and security
anywhere
Apartment
buildings
Wired and wireless detectors
Local alarm acknowledge units, wireless and wired
Sounder bases and sirens
Loop expander and I/O units
Restaurants
and hotels
Wireless detectors and manual call points
Integrated exit and emergency lights
Detectors with AI for kitchen and challenging areas
Sounder bases, sirens and visual alarm devices
6
Schools and
kindergartens
Wired and wireless detectors
Integrated exit and emergency lights
Sounder bases, sirens and visual alarm devices
Manual call points
Ofces and
small industry
Detectors with AI
Aspirating and EX detectors for tough areas
Integrated exit and emergency lights
Sounder bases, sirens and visual alarm devices
Loop expander and I/O units
7
Unique user interface
With the integrated and symbol
based status LEDs you instantly
get an overview of the status
of the re alarm system.
The colour touch display
is used for CIE operations
such as commissioning, test
and maintenance.
The LCD works as an alarm
presentation unit enabling re
brigade to get full information and
reset and silence alarm devices.
App based
menu system
6 main applications
Status, Settings, Disable,
Installation, Test and Maintenance
Deviations
highlighted
Clear visual menus
and sub-menus
with symbols and texts
Easy to navigate
with path function
8
Auto set-up wizard
A wizard-based graphical tool guides you through
the process, eliminating the need for a PC, and
allowing you to set up users and passwords, assign
zones and addresses, and add alarm texts.
EBLWin software
Our program can of course also be used with
EBLOne. Auto address by simply connecting
to the system and let EBLWin guide you
thru the complete process.
Two fast and easy
commissioning options
9
VAD
4381
Wall VAD
4480
Ceiling VAD
4481
Siren
4487
VAD with siren
4482
External indicator
4418
Addressable
Input unit
4462
2 monitored inputs
IP65
Local Alarm Acknowledge Unit
4445
Heat detector
4409
IP67
Input/Output unit
4461
Conventional
heat detector
6295: 57ºC
6296: 72ºC
6297: 87ºC
6298: 117ºC
IP67
Manual call point
4433
Manual call point
4439
IP66
Incl. Back box and
protective cover
24 VDC
2 x 2A
Power supply
4466
230 VAC230 VAC
opt. 12-24 VDC
Aspirating smoke detector
AE2010G-P
Consult list of available acces.
Doc. MEW01860
BLE
IS barrier
2842
Up to 20 addressable detectors
24 VDC
Heat detector
4408
Multi detector with CO
4402
Multi detector
4400
Smoke detector
4401
Detector base
3312
Detector base
3312F
Detector base
3312FL
Sounder base
3379
86 dB
Detector base
4412F
Detector base
4412S
Detector base
4412J
Smoke detector
4401I
Multi detector
4400I
Sounder base
4479
90 dB
IS smoke detector
2840
IS heat detector
2841
IP67
IS back box
2843
Input/Output unit
4461
Smoke
detector
4452
Heat
detector
4318
Conventional line
Detector base: 2324
IP67
230 VAC relay
output unit
4460
1 programmable
8A relay output
Sub-loop
COM-loop
Gateway
5088
COM-loop repeater
4585
1
Zone line input
“loop powered”
1
Monitored
input
1
Isolated
input
2
Relay
outputs
4472 EOL4472 EOL
Conventional
Expansion board
4464
Wireless base station
4620
Up to 4 stations in the loop
24 VDC
Addressable
wireless system
Up to 16 units
on each base station 4620
6 years
Local Alarm
Acknowledge Unit
4645
Smoke detector
4611
> 85 dB
Manual call point
4614
230 VAC
COM loop
SUB loops
Addresses
Isolators
Wireless devices
1
4
253
128
64
Emergency light
MX R and MX C
Exit light
MX25 and MX40
Exit light
MX25 and MX40 red X
ISO 7010
pictograms
MX25: 25 m
MX40: 40 m
ISO 7010
pictograms
MX IP65: 25 m
Exit / Emergency light
MX IP65
Outdoor Emergency Light
MX
IP65
COMPATIBLE BASES
3312W, 3312FLW LED 1h
MX Power box
External 24 VDC is required from MX Power box
230 VAC
LED 3h
Panasonic is continuously developing new loop units.
Please check our website for more details: www.panasonic-fire-security.com
System diagram
VAD
4381
Wall VAD
4480
Ceiling VAD
4481
Siren
4487
VAD with siren
4482
External indicator
4418
Addressable
Input unit
4462
2 monitored inputs
IP65
Local Alarm Acknowledge Unit
4445
Heat detector
4409
IP67
Input/Output unit
4461
Conventional
heat detector
6295: 57ºC
6296: 72ºC
6297: 87ºC
6298: 117ºC
IP67
Manual call point
4433
Manual call point
4439
IP66
Incl. Back box and
protective cover
24 VDC
2 x 2A
Power supply
4466
230 VAC230 VAC
opt. 12-24 VDC
Aspirating smoke detector
AE2010G-P
Consult list of available acces.
Doc. MEW01860
BLE
IS barrier
2842
Up to 20 addressable detectors
24 VDC
Heat detector
4408
Multi detector with CO
4402
Multi detector
4400
Smoke detector
4401
Detector base
3312
Detector base
3312F
Detector base
3312FL
Sounder base
3379
86 dB
Detector base
4412F
Detector base
4412S
Detector base
4412J
Smoke detector
4401I
Multi detector
4400I
Sounder base
4479
90 dB
IS smoke detector
2840
IS heat detector
2841
IP67
IS back box
2843
Input/Output unit
4461
Smoke
detector
4452
Heat
detector
4318
Conventional line
Detector base: 2324
IP67
230 VAC relay
output unit
4460
1 programmable
8A relay output
Sub-loop
COM-loop
Gateway
5088
COM-loop repeater
4585
1
Zone line input
“loop powered”
1
Monitored
input
1
Isolated
input
2
Relay
outputs
4472 EOL4472 EOL
Conventional
Expansion board
4464
Wireless base station
4620
Up to 4 stations in the loop
24 VDC
Addressable
wireless system
Up to 16 units
on each base station 4620
6 years
Local Alarm
Acknowledge Unit
4645
Smoke detector
4611
> 85 dB
Manual call point
4614
230 VAC
COM loop
SUB loops
Addresses
Isolators
Wireless devices
1
4
253
128
64
Emergency light
MX R and MX C
Exit light
MX25 and MX40
Exit light
MX25 and MX40 red X
ISO 7010
pictograms
MX25: 25 m
MX40: 40 m
ISO 7010
pictograms
MX IP65: 25 m
Exit / Emergency light
MX IP65
Outdoor Emergency Light
MX
IP65
COMPATIBLE BASES
3312W, 3312FLW LED 1h
MX Power box
External 24 VDC is required from MX Power box
230 VAC
LED 3h
Panasonic is continuously developing new loop units.
Please check our website for more details: www.panasonic-fire-security.com
System diagram
Doc: MEW02909 Rev: - | Date: 2023-05-16
Panasonic Fire & Security Europe AB
Jungmansgatan 12
SE-211 11 Malmö, Sweden
+46 (0) 40 697 7000
www.panasonic-re-security.com
/