Invacare POC1–100B, Platinum Mobil, POC1–100B-C User manual

  • Hello! I am an AI chatbot trained to assist you with the Invacare POC1–100B User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Invacare®Platinum™Mobile
POC1–100B,POC1–100B-C
enOxygenConcentrator
UserManual
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuturereference.
©2016InvacareCorporation
Allrightsreserved.Republication,duplicationormodificationinwholeorinpartisprohibitedwithout
priorwrittenpermissionfromInvacare.Trademarksareidentifiedby™and®.Alltrademarksare
ownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted.
PlatinumisaregisteredtrademarkintheU.S.A.,EuropeandAustralia.
MakingLife’sExperiencesPossibleisaregisteredtrademarkintheU.S.A.
Pine-sol,LestoilandCloroxareregisteredtrademarksofTheCloroxCompany.
DawnisaregisteredtrademarkofTheProctorandGambleCompany.
Contents
1General........................................5
1.1QuickStartGuide..............................5
1.2Symbols.....................................9
1.3IndicationsForUse.............................11
1.4IntendedUse..................................11
1.5Contraindications..............................11
1.6Features.....................................12
1.6.1ControlPanel...............................12
1.6.2Input/OutputConnections.....................13
1.6.3Filters....................................13
1.6.4PowerOptions..............................13
1.6.5CarryBag..................................14
1.7OptionalAccessoriesandReplacementParts...........14
2Safety..........................................15
2.1LabelLocations................................15
2.2GeneralGuidelines.............................16
2.3RadioFrequencyInterference......................20
2.4TravelingwiththeConcentrator....................21
3Setup..........................................23
3.1Unpacking....................................23
3.2Inspection....................................23
3.3PoweringtheOxygenConcentrator.................23
3.3.1InstallingtheBattery(s)........................23
3.3.2ChargingtheBattery(s)........................24
3.3.3ReadingtheBatteryGaugeforInstalledand
UninstalledBattery(s)........................25
3.3.4RemovingtheBattery(s).......................26
3.3.5ExternalACPower...........................27
3.3.6ExternalDCPower..........................27
3.4CarryBagSetup................................28
3.4.1InstallingtheCarryBag........................28
3.4.2RemovingtheCarryBag.......................29
3.4.3InstallingShoulderStraps.......................29
3.5Connecting/PositioningtheNasalCannula.............30
4Usage..........................................32
4.1Location.....................................32
4.2ConcentratorOperatingPosition...................32
4.3UsingtheCarryBag.............................32
4.4TurningOntheConcentrator.....................33
4.5TurningOfftheConcentrator.....................33
4.6WarmUpPeriod...............................34
4.7BreathingwiththeUseoftheConcentrator...........34
4.8ReadingtheDisplayScreen........................34
4.9AdjustingthePulseFlowSetting....................35
4.10BatteryLifeandManagement.....................36
5Maintenance....................................37
5.1Maintenance..................................37
5.2ServiceLife...................................37
5.3CleaningtheCabinet............................37
5.4CleaningtheAirIntakeFilterScreen.................38
5.5CleaningtheCarryBag..........................38
5.6CleaningandDisinfectionBetweenPatients............39
5.7ViewingHourMeter............................40
5.8PreventativeMaintenanceChecklist.................41
6AfterUse.......................................43
6.1Storage......................................43
6.2Disposal.....................................43
6.3WearandTear................................44
7Troubleshooting.................................45
7.1Troubleshooting...............................45
7.2AlarmConditions..............................47
7.2.1OperationalAlarms..........................47
7.2.2ShutDownAlarms...........................55
8TechnicalData..................................60
8.1TechnicalDescription...........................60
8.2Specifications..................................60
8.3RegulatoryListing..............................64
8.4ElectromagneticCompliance(EMC).................65
9Warranty.......................................69
9.1NorthAmericanLimitedWarranty..................69
General
1General
1.1QuickStartGuide
IMPORTANT!
TheQuickStartGuideisforreferenceONLY.Itis
imperativetoreadthemanualititsENTIRETYfor
fullinstructions.
DANGER!
RiskofDeath,Injury,fromElectricShock
Toreducetheriskofburns,electrocution,deathor
injurytopersons:
DONOTdisassemble.Referservicingtoqualified
servicepersonnel.Therearenouserserviceable
parts.
WARNING!
RiskofInjuryorDamage
Useofthisproductoutsideoftheintendeduseand
specificationshasnotbeentestedandmayleadto
productdamage,lossofproductfunction,orinjury.
DONOTusethisproductinanywayotherthan
describedinthespecificationsandintendeduse
sectionsofthismanual.
DANGER!
RiskofDeath,InjuryOrDamageFromFire
Textiles,oilorpetroleumsubstances,grease,greasy
substancesandothercombustiblesareeasilyignited
andburnwithgreatintensityinoxygenenrichedairand
whenincontactwithoxygenunderpressure.Smoking
duringoxygentherapyisdangerousandislikelytoresult
inburnsordeath.Toavoidfire,death,injuryordamage:
DONOTSMOKEwhileusingthisdevice.DONOT
usenearOPENFLAMEorIGNITIONSOURCES.
NOSMOKINGsignsshouldbeprominentlydisplayed.
Avoidcreationofanysparknearoxygenequipment.
Thisincludessparksfromstaticelectricitycreatedby
anytypeoffriction.
Useonlyoxygencompatiblewater-basedlotions
orsalvesbeforeandduringoxygentherapy.To
verify,refertothelotion/salvecontainerforoxygen
compatiblewater-basedstatement.Ifnecessary,
contactthemanufacturer.DONOTuseany
lubricantsonconcentratorunlessrecommendedby
Invacare.
Keeptheoxygentubing,cord,ACadapter,and
concentratoroutfromundersuchitemsasblankets,
bedcoverings,chaircushions,clothing,andawayfrom
heatedorhotsurfacesincludingspaceheaters,stoves,
andsimilarelectricalappliances.
Makesureconcentratorisoffwhennotinuse.
1194969-A-005
Invacare®Platinum™Mobile
DANGER!
RiskOfDeath,InjuryOrDamage
Improperuseoftheproductmaycausedeath,injuryor
damage.Thissectioncontainsimportantinformationfor
thesafeoperationanduseofthisproduct.
DONOTusethisproductoranyavailableoptional
equipmentwithoutfirstcompletelyreadingand
understandingtheseinstructionsandanyadditional
instructionalmaterialsuchasusermanuals,service
manualsorinstructionsheetssuppliedwiththis
productoroptionalequipment.
Ifyouareunabletounderstandthewarnings,cautions
orinstructions,contactahealthcareprofessional,
dealerortechnicalpersonnelbeforeattemptingto
usethisequipment.
CheckALLexternalcomponentsandcartonfor
damage.Incaseofdamage,oriftheproductisnot
workingcorrectly,contactatechnicianorInvacare
forrepair.
Thisproductisintendedtobeusedbyadultsonly
afterreadingandunderstandingtheinstructionsand
warningsofthisusermanual.
THEINFORMATIONINTHISDOCUMENTIS
SUBJECTTOCHANGEWITHOUTNOTICE.
61194969-A-00
General
1.Openthebatterycompartmentdoor.Withbatteryfuelgauge
labelfacingtowardthefrontoftheoxygenconcentrator,slowly
lowerbatteryAstraightdownintooneofthetwoslotsinthe
batterycompartment.
RefertoInstallingtheBattery(s)inSetup.
2.ConnecttheACPowerAdaptertotheexternalpowerinput
connectorB.PlugtheACcordintotheelectricaloutlet.
RefertoExternalACPowerinSetup.
Usingtheconcentratorforthefirsttimerequires
thebattery(s)tobecharged.RefertoChargingthe
Battery(s)inSetup.
3.Connectthenasalcannulatotheconcentratoroxygenoutlet
portonyourconcentratorC.Oxygenwillonlybedelivered
whileyouarebreathingthroughthenasalcannulaconnected
tothisdevice.
RefertoConnecting/PositioningtheNasalCannulainSetup.
1194969-A-007
Invacare®Platinum™Mobile
4.
TurnontheconcentratorbypressingtheOn/OffButtonDuntil
thecontrolpanelindicatorslightup.
RefertoTurningontheConcentratorinUsage.
5.
Adjustthepulseflowsettingtotheoneprescribedbyyour
clinicalprofessional.Thepulseflowsettingcanbechangedby
pressingtheflowselectionbuttonE.Placethenasalcannula
overyourearsandpositiontheprongsinyournoseasinstructed
byyourhealthcareprovider.
RefertoAdjustingthePulseFlowSettinginUsage.
81194969-A-00
General
1.2Symbols
Signalwordsareusedinthismanualandapplytohazardsorunsafe
practiceswhichcouldresultinpersonalinjuryorpropertydamage.
Refertotheinformationbelowfordefinitionsofthesignalwords.
DANGER!
Dangerindicatesanimminentlyhazardoussituation
which,ifnotavoided,willresultindeathorserious
injury.
WARNING!
Warningindicatesapotentiallyhazardoussituation
which,ifnotavoided,couldresultindeathorserious
injury.
CAUTION!
Cautionindicatesapotentiallyhazardoussituation
which,ifnotavoided,mayresultinpropertydamage
orminorinjuryorboth.
IMPORTANT!
Importantindicatesahazardoussituationthatcould
resultindamagetopropertyifitisnotavoided.
Givesusefultips,recommendationsandinformationfor
efficient,trouble-freeuse.
Refertothefollowingtableforthemeaningofsymbolsmarkedon
theequipmentand/orpackaging.
GeneralWarningSign
Thebackgroundcolorinsidethetriangleis
yellowonproductlabels.
FollowInstructionsforUse
Thecolorofthesymbolbackgroundisblue
onproductlabels.
Noopenflame
Thecolorofthecirclewithdiagonalbaris
redonproductlabels.
DONOTSmoke
Thecolorofthecirclewithdiagonalbaris
redonproductlabels.
ConsultInstructionsforUse
Thissymbolislocatedonthecannula
packing.
DirectCurrent
TypeBFAppliedPart
ClassIIEquipment
1194969-A-009
Invacare®Platinum™Mobile
PowerOn/Off
DataOutputTerminal
DONOTdisposeofinhouseholdwaste
Manufacturer
DateofManufacture
Recycle
SerialNumber
DONOTReuse(SinglePatientUseOnly)
Thissymbolreferstothecannulawhichis
forsinglepatientuseonly.
LatexFree
IndoorUseONLY
ThissymbolisincludedontheACpower
adapter.
DONOTuseoilorgrease
Keepdry
Protectedagainstsolidforeignobjectsof12.5mm
diameterandgreater.
Protectedagainstverticallyfallingwaterdropswhen
enclosuretiltedupto15°.
Protectedagainstsolidforeignobjectsof12.5mm
diameterandgreater.
Protectedagainstverticallyfallingwaterdrops.
TransportandStorageTemperature
TransportandStorageHumidity
74103
ElectricalSafetyAgencyCertificationMark
101194969-A-00
General
1.3IndicationsForUse
TheInvacare®Platinum™MobileOxygenConcentratorisintended
toprovidesupplementaloxygentopatientswithrespiratory
disorders.Thedevicecanbeusedinahome,institution,vehicle,or
otherenvironmentsoutsidethehome.
1.4IntendedUse
TheInvacare®Platinum™MobileOxygenConcentratorisintended
toprovidesupplementaloxygentopatientswithrespiratory
disorders.TheInvacare®Platinum™MobileOxygenConcentrator
canbeusedinahome,institution,vehicle,orotherenvironments
outsidethehome.Thedeviceisnotintendedtobelife-supportingor
life-sustaining.
WARNING!
RiskofInjuryorDamage
Useofthisproductoutsideoftheintendeduseand
specificationshasnotbeentestedandmayleadto
productdamage,lossofproductfunction,orpersonal
injury.
DONOTusethisproductinanywayotherthan
describedinthespecificationsandintendeduse
sectionsofthismanual.
1.5Contraindications
WARNING!
RiskofInjury
Thisproductistobeusedasanoxygensupplementand
isnotintendedtobelife-supportingorlife-sustaining.
ONLYusethisproductifthepatientiscapableof
spontaneousbreath,abletoinhaleandexhalewithout
theuseofamachine
DONOTuseinparallelorserieswithotheroxygen
concentratorsoroxygentherapydevices.
WARNING!
RiskofMinorInjuryorDiscomfort
Theconserving,orpulsedose,oxygendeliverytechnique
usedbythisdeviceiscontraindicatedinpersonswhose
breathingduringnormalrestingwouldbeunableto
triggerthedevice.
Properdevicetriggering,setupandoperationmust
beconfirmedbyanexperiencedclinicianorother
respiratoryprofessional.
Notforpediatricuse.
Notforusebytracheotomizedpatients.
1194969-A-00
11
Invacare®Platinum™Mobile
1.6Features
1.6.1ControlPanel
A
On/OffButton
Pressforonesecondtoturnconcentratoronoroff.
B
FlowSelectionButton
Presstoadjustthepulsedoxygenflowtoyourprescribed
setting.Theselectedflowsettingisshownonthedisplay
screen.RefertoAdjustingthePulseFlowSettinginUsage
formoredetails.
C
DisplayBacklightButton
Pressoncetoilluminatethedisplayscreenfor5seconds.
D
AudioOffButton
Presstomutetheaudiblesignal(beep)forbothalarms
andstatusindications.Theblueindicatorlightnextto
thebuttonilluminateswhenactivated.Audiooffcanbe
activatedduringorpriortoanalarmconditionoccurring.
E
DisplayScreen
Displaysinformationabouttheoperatingstatusofthe
concentrator.
F
AlarmIndicator
Theyellowindicatorlightatthecenterofthetriangular
symbolilluminatestoindicateabnormaloperating
conditions.RefertoAlarmConditionsinTroubleshooting
formoredetails.
G
BatteryGauge
Indicatesthechargestatusofthebattery(s).Referto
ReadingtheBatteryGaugeforInstalledandUninstalled
Battery(s)inSetupformoredetails.
H
ExternalPowerIndicator
Theorangeindicatorlightnexttotheplugsymbol
illuminateswhenanexternalpowersourceisconnected
totheconcentrator.
I
BatteryCompartmentDoor
Usedtoaccesstheremovablebattery(s).
Not
Shown
AudibleSignal(Beep)
Indicatesachangeinoperatingstatusoracondition
whichrequirestheoperator’sattention.
12
1194969-A-00
General
1.6.2Input/OutputConnections
A
OxygenOutletPort
Usedtoconnectthenasalcannulatotheconcentrator.
B
ExternalPowerInputConnector
Usedtoconnectanexternalpowersourcetothe
concentrator.
C
USBPort
Usedforserviceonly.
1.6.3Filters
Airenterstheconcentratorthroughanairintakefilterlocatedonthe
carrybag.Thisfilterpreventshairandotherlargeparticlesintheair
fromenteringtheunit.Beforeyouoperatetheconcentrator,make
surethisfilteriscleananddry,andtheconcentratorisproperly
installedinthecarrybag.
Tocleantheairintakefilter,refertoCleaningtheAirIntakeFilter
ScreeninMaintenance.
Toensuretheconcentratorisproperlyinstalledinthecarrybag,
refertoInstallingtheCarryBaginSetup.
1.6.4PowerOptions
WARNING!
RiskofInjuryorDamage
Toavoidinjuryordamagewhichwillvoidwarranty:
UseonlyInvacarespecifiedpowersupplies.
Battery(s):Uptotworechargeablebatteriescanbeinstalledinthe
batterycompartmentoftheconcentrator.Whenfullycharged,a
singlebatterysuppliespowerforuptofivehours(uptotenhours
fortwobatteries).Visibleandaudiblealarmsignalsoccurwhen
thebatterypowerisgettinglow.RefertoAlarmConditionsin
TroubleshootingandChargingtheBattery(s)inSetup.
ACPowerAdapter:AnACpoweradapterallowsthe
concentratortobeconnectedtoa100–240volt50–60hertzoutlet.
UseoftheACpoweradapterwillallowtheconcentratortooperate
andsimultaneouslyrechargetheinstalledbattery.RefertoCharging
theBattery(s)inSetup.
DCPowerCable:ADCpowercableallowstheconcentratorto
beconnectedtoanautomobile’s(boat,motorhome,etc.)12-volt
DCoutlet.UseoftheDCpowercablewillallowtheconcentrator
tooperateandsimultaneouslyrechargeaninstalledbattery(s).Refer
toChargingtheBattery(s)inSetup.
1194969-A-0013
Invacare®Platinum™Mobile
1.6.5CarryBag
Thecarrybagprovidesaconvenientmeanstoholdtheconcentrator
whileperformingdailyactivities.
Itcanbeconfiguredasamessengerbagorbackpackusingthe
shoulderstrapsprovided.RefertoInstallingtheCarryBaginSetup.
1.7OptionalAccessoriesandReplacement
Parts
ThefollowingoptionalaccessoriesareavailablefromInvacare:
Additionalbatteries,modelnumber:POC1–110
Externalbatterychargerwithpowersupply:POC1–115
ThefollowingreplacementpartsareavailablefromInvacare:
Battery,modelnumber:POC1–110
CarryBag,modelnumber:POC1–150
DCpowercable,modelnumber:POC1–140
ACpoweradapterwithpowercord:POC1–130
Thesepartsarebasemodels.PleasecontactInvacareor
yourproviderforcountryspecificmodels.
14
1194969-A-00
Safety
2Safety
2.1LabelLocations
Platinum Mob ile
Oxyg en Concent rator
Mod e l # POC1-100B
USA
One Invacare W ay
Elyria, Ohio USA
44035-2125
Tel: 44 0-3 29 -6000
800-333-6900
Tec h n ic a l Services
Tel: 44 0-3 29 -6593
800-832-4707
Manufacturer:
Invacare Corporation
2101 E. Lake Mary Blvd
Sanford, FL 32773
Tel: 40 7-3 21 -5630
Inva c a re Co rpo ratio n
www .invacare.com
Co n fo rm s to AAMI S TD ES 6 0601-1 , ISO S TDS 80601-2-67 , 8060 1-2-69, IEC S TDS 60601-1-8, 60601-1-11, 6 0601-1 -6
Ce rt ifie d to CSA STD C22 .2 No . 60601-1
DANGER - RISK OF FIRE
NO SMOKING -
Kee p ALL s ourc e s of ig n it io n ou t o f th e a re a in whic h th is p rod u c t is loc a t e d an d awa y fro m a re a s
wh e re o xygen is b e in g d e livere d .
Te xtile s , o ils a n d oth e r c o m b u s tib le s a re e a s ily ig n ite d and b u rn with g re a t in t e n s ity in o xyg e n en rich e d a ir.
The b a tte ry u s e d in this d e vic e m a y p re s en t a ris k o f fire . DO NOT d is as s e mb le , in c in e rate , s h o rt te rm in a ls o r h e a t
ab o ve 6 0° C (140° F).
DANGER - RISK OF ELECTRIC SHOCK
DO NOT dis a s se m b le . Refer s e rvic in g to qu a lifie d s ervice p e rs o n n e l. No u s er s e rvic e a b le p a rts in s ide .
WARNING - RISK OF INJ URY
The d e vice is n o t in te n d e d to be life -s u p p o rtin g o r life -s us ta in in g .
CAUTION - DO NOT a d ju s t t h e flow s e ttin g u n le s s a c h a n g e h a s b e e n pre s c ribe d by yo ur p h ys ic ia n o r th e ra p is t.
Prote c ted a g a in s t s olid fo r e ig n o b je c ts o f 12.5m m diam e te r a n d g r e a t e r.
Prote c ted a g a in s t v e rtic a lly fa llin g wa ter drops wh e n e n c lo s ur e tilte d up to 15°.
Fo r pres c riptio n u s e O NLY. DO NOT us e o il o r g r e a s e.
The m a n u fa c tu rer of th is POC h a s d e te rmine d th is d e vic e con fo rm s to all a p p lic a b le FAA re q u ire m e n ts for P OC
car riag e an d us e o n b o a rd a ir c ra ft.
118 75 25 ~A~07
74103
O
2
% = 87 % - 95.6%
Follow Ins truc tions
For Us e
DO NO T
SMOKE
NO O P EN
FLAME
Re cyc le Type BF
Applie d Pa rt
Cla ss II
Equipm e nt
Thelabelislocatedonthebackoftheconcentrator.Theserialnumberislocatedontherightsideoflabelshownhere.
1194969-A-0015
Invacare®Platinum™Mobile
2.2GeneralGuidelines
Inordertoensurethesafeinstallation,assemblyandoperationofthe
concentratortheseinstructionsMUSTbefollowed.
DANGER!
RiskOfDeath,InjuryOrDamage
Improperuseoftheproductmaycausedeath,injuryor
damage.Thissectioncontainsimportantinformationfor
thesafeoperationanduseofthisproduct.
DONOTusethisproductoranyavailableoptional
equipmentwithoutfirstcompletelyreadingand
understandingtheseinstructionsandanyadditional
instructionalmaterialsuchasusermanuals,service
manualsorinstructionsheetssuppliedwiththis
productoroptionalequipment.
Ifyouareunabletounderstandthewarnings,cautions
orinstructions,contactahealthcareprofessional,
dealerortechnicalpersonnelbeforeattemptingto
usethisequipment.
CheckALLexternalcomponentsandcartonfor
damage.Incaseofdamage,oriftheproductisnot
workingcorrectly,contactatechnicianorInvacare
forrepair.
Thisproductisintendedtobeusedbyadultsonly
afterreadingandunderstandingtheinstructionsand
warningsofthisusermanual.
THEINFORMATIONINTHISDOCUMENTIS
SUBJECTTOCHANGEWITHOUTNOTICE.
DANGER!
RiskofDeath,InjuryOrDamageFromFire
Textiles,oilorpetroleumsubstances,grease,greasy
substancesandothercombustiblesareeasilyignited
andburnwithgreatintensityinoxygenenrichedairand
whenincontactwithoxygenunderpressure.Smoking
duringoxygentherapyisdangerousandislikelytoresult
inburnsordeath.Toavoidfire,death,injuryordamage:
DONOTSMOKEwhileusingthisdevice.DONOT
usenearOPENFLAMEorIGNITIONSOURCES.
NOSMOKINGsignsshouldbeprominentlydisplayed.
Keepallopenflames,matches,lightedcigarettes,
electroniccigarettesorothersourcesofignitionat
least10ft(3m)awayfromthisconcentratororany
oxygencarryingaccessoriessuchascannulasortanks.
Ifyoudisregardthesewarningsaboutthesevere
hazardofoxygenusewhileyoucontinuetosmoke,
youmustalwaysturnofftheconcentrator,remove
thecannulaandthenwaittenminutesbeforesmoking
orleavetheroomwhereeithertheconcentratoror
anyoxygencarryingaccessoriessuchascannulasor
tanksarelocated.
DONOTSMOKEwhileusingtheconcentrator.
CAUTION!
Federal(statutory)lawrestrictsthisdevicetosaleby
orontheorderofamedicalpractitionerlicensedbya
governmentalagencywherehe/shepractices.
ONLYalicensedmedicalpractitionermayorderthe
purchaseoruseofthisdevice.
161194969-A-00
Safety
DANGER!
RiskofDeath,InjuryOrDamageFromFire
Textiles,oilorpetroleumsubstances,grease,greasy
substancesandothercombustiblesareeasilyignited
andburnwithgreatintensityinoxygenenrichedairand
whenincontactwithoxygenunderpressure.Toavoid
fire,death,injuryordamage:
Avoidcreationofanysparknearoxygenequipment.
Thisincludessparksfromstaticelectricitycreatedby
anytypeoffriction.
Useonlyoxygencompatiblewater-basedlotions
orsalvesbeforeandduringoxygentherapy.To
verify,refertothelotion/salvecontainerforoxygen
compatiblewater-basedstatement.Ifnecessary,
contactthemanufacturer.DONOTuseany
lubricantsonconcentratorunlessrecommendedby
Invacare.
Keeptheoxygentubing,cord,ACadapter,and
concentratoroutfromundersuchitemsasblankets,
bedcoverings,chaircushions,clothing,andawayfrom
heatedorhotsurfacesincludingspaceheaters,stoves,
andsimilarelectricalappliances.
Makesureconcentratorisoffwhennotinuse.
CAUTION!
RiskofMinorInjuryorDiscomfort
Itisimportanttoplanaheadfortravelandother
situationsinwhichyoumaynothaveaccesstoadditional
oxygenorpowersupplies.Topreventinjuryfrom
oxygendeprivation:
Carrysupplementalbatterieswithyou.
Stowtheconcentratorproperlyduringtravel.For
properstorageinstructionswhentravellingreferto
thetravelguide.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamagefrommisuse:
NEVERleaveconcentratorunattendedwhen
connectedtopower.
Makesureconcentratorisoffwhennotinuse.
OutdooruseMUSTbeconductedwithinternal
batterypoweronly.
WARNING!
RiskOfInjuryOrDamage
Invacareproductsarespecificallydesignedand
manufacturedforuseinconjunctionwithInvacare
providedorInvacarespecifiedaccessories.Anyother
accessorieshavenotbeentestedbyInvacareandare
notrecommendedforusewithInvacareproducts.
Nomodificationofthisequipmentisallowed.
1194969-A-0017
Invacare®Platinum™Mobile
CAUTION!
RiskofMinorInjuryorDiscomfort
Achangeinaltitudemayaffecttotaloxygenavailableto
you.Topreventoxygendeprivation:
Consultyourphysicianbeforetravelingtohigheror
loweraltitudestodetermineifyourflowsettings
shouldbechanged.
DANGER!
RiskofDeath,Injury,fromElectricShock
Toreducetheriskofburns,electrocution,deathor
injurytopersons:
DONOTdisassemble.Referservicingtoqualified
servicepersonnel.Therearenouserserviceable
parts.
Avoidusingwhilebathing.Ifcontinuoususage
isrequiredbythephysician'sprescription,the
concentratormustbelocatedinanotherroomat
least7ft(2.5m)fromthebath.
DONOTcomeincontactwiththeconcentrator
whilewet.
DONOTplaceorstoreconcentratorwhereitcan
dropintowaterorotherliquid.
DONOTreachforconcentratorthathasfalleninto
water.UnplugIMMEDIATELY.
DONOTblockaccesstopoweroutletneededto
unplugtheACpowercord.
DONOTusefrayedordamagedpowercords.
DONOTuseACpoweradapterifitshousingis
crackedorseparated.
WARNING!
RiskofInjuryorDeath
Topreventinjuryordeathfromproductmisuse:
Closelysupervisewhenthisconcentratorisusedby
impairedindividualsornearchildrenand/orimpaired
individuals.
Monitorpatientsusingthisdevicewhoareunableto
hearorseealarmsorcommunicatediscomfort.
CAUTION!
RiskofMinorInjuryorDiscomfort
WhileInvacarestrivestoproducethebestoxygen
concentratorinthemarkettoday,thisoxygen
concentratorcanfailtoproduceoxygenduetopower
failureordevicemalfunction.
ALWAYShaveabackupsourceofoxygenreadily
available.
Intheeventtheconcentratorfailstoproduceoxygen,
theconcentratorwillbrieflyalarmsignalingthepatient
toswitchtotheirbackupsourceofoxygen.Referto
Troubleshootingformoredetail.
Invacarerecommendskeepingatleastonebattery
installedintheconcentratorevenwhenoperating
fromanexternalpowersource.
181194969-A-00
Safety
WARNING!
RiskofDeath,InjuryorDamage
Topreventinjuryordamagefromcordmisuse:
DONOTmoveorrelocateconcentratorbypulling
onthecord.
DONOTuseextensioncordswithACpower
adaptersprovided.
Properlystoreandpositionelectricalcordsand/or
tubingtopreventatrippingandstrangulationhazards.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamageduringuse:
Ifyoufeelilloruncomfortable,oriftheconcentrator
doesnotsignalanoxygenpulseandyouareunable
tohearand/orfeeltheoxygenpulse,consult
yourequipmentproviderand/oryourphysician
IMMEDIATELY.
Foroptimumperformance,Invacarerecommendsthat
eachuseoftheconcentratorbeaminimumof30
minutes.Shorterperiodsofoperationmayreduce
maximumproductlife.
Theconcentratorshouldbeusedinanupright
position.
Theconcentratorcannotbeusedinconjunctionwith
PAP,Bi-Level,mechanicalventilatororothersuch
devices.
CAUTION!
RiskofMinorInjury,DiscomfortorDamage
Useofthisdeviceatanaltitudeabove10,000ft(3048
m)oroutsideatemperatureof41°Fto104°F(5°Cto
40°C)orarelativehumidityabove90%isexpected
toadverselyeffecttheflowrateandthepercentageof
oxygenandconsequentlythequalityoftherapy.
WARNING!
RiskofInjuryorDamage
Asasafetyfeature,thisappliancemayhaveapolarized
plug(onebladeiswiderthantheother).Toavoidinjury
ordamagefromelectricalshock:
Thisplugwillfitinapolarizedoutletonlyoneway.
Iftheplugdoesnotfitfullyintheoutlet,reverse
theplug.Ifitstilldoesnotfit,contactaqualified
electrician.
DONOTalterthepluginanyway.
DONOTuseifthecordorplugaredamaged.Calla
qualifiedelectricianforrepair.
1194969-A-0019
Invacare®Platinum™Mobile
CAUTION!
RiskofDamage
Topreventdamagefromtemperaturevariations:
DONOToperateintemperaturesbelow41°F(5°C)
orabove104°F(40°C).
Whenyourautomobileisturnedoff,disconnect
thecaraccessorypowercordandremovethe
concentratorfromtheautomobile.NEVERallow
theconcentratortobestoredinaveryhotor
coldautomobileorinothersimilar,highorlow,
temperatureenvironments.RefertoSpecificationsin
TechnicalData.
WARNING!
RiskofInjuryorDamage
Topreventdamagefromliquidingress:
Iftheconcentratorisnotworkingproperly,ifit
hasbeendroppedordamaged,ordroppedinto
water,callequipmentprovider/qualifiedtechnicianfor
examinationandrepair.
NEVERdroporinsertanyobjectorliquidintoany
opening.
Invacarerecommendstheconcentratornotbeused
intherain.
Theconcentratorisnotdesignedtobeusedwitha
humidifier.Useofthisdevicewithahumidifiermay
impairperformanceand/ordamagetheequipment.
DONOTuseifcabinetofconcentratororhousingof
ACpoweradapteriscrackedorseparated.
2.3RadioFrequencyInterference
MedicalElectricalEquipmentneedstobeinstalledandusedaccording
totheEMCinformationinthismanual.
ThisequipmenthasbeentestedandfoundtocomplywithEMClimits
specifiedbyIEC/EN60601-1-2.Theselimitsaredesignedtoprovide
areasonableprotectionagainstelectromagneticinterferenceina
typicalhomehealthcareenvironment.
PortableandmobileRFcommunicationsequipmentcanaffectthe
operationofthisequipment.Useofthisequipmentadjacenttoor
stackedwithotherequipmentshouldbeavoidedasitcouldresultin
improperoperation.Theconcentratoroperationshouldbeobserved
toverifynormaloperationinthepresenceofsuchequipment.
Otherdevicesmayexperienceinterferencefromeventhelowlevels
ofelectromagneticemissionspermittedbytheabovestandards.To
determineiftheemissionsfromtheconcentratorarecausingthe
interference,turntheconcentratoroff.Iftheinterferencewith
theotherdevice(s)stops,thentheconcentratoriscausingthe
interference.Insuchrarecases,interferencemaybereducedor
correctedbyoneofthefollowingmeasures:
Reposition,relocate,orincreasetheseparationbetweenthe
equipment.
Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichtheotherdevice(s)isconnected.
RefertoElectromagneticCompliance(EMC)inTechnicalDatafor
additionalinformation.
201194969-A-00
/