Invacare®XPO
XPO100,XPO100B
enPortableOxygenConcentrator
UserManual................................3
esConcentradordeoxígenoportátil
Manualdelusuario...........................41
frConcentrateurd'oxygèneportatif
Manueld'utilisation..........................83
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuturereference.
©2014Invacare®Corporation
Allrightsreserved.Republication,duplicationormodificationinwholeorinpartisprohibitedwithout
priorwrittenpermissionfromInvacare.Trademarksareidentifiedby™and®.Alltrademarksare
ownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted.
Pine-solandLestoilaretrademarksofTheCloroxCompany.
DawnisatrademarkofTheProctorandGambleCompany.
Contents
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuture
reference.
1General........................................4
1.1Symbols.....................................4
1.2IntendedUse..................................5
1.2.1Description................................5
1.3Features.....................................6
1.3.1UserInterface..............................6
1.3.2Indicators,Warnings,andAlarms.................7
1.3.3Filters....................................7
1.3.4PowerSupplies..............................8
2Safety..........................................9
2.1TypicalProductParameters.......................9
2.2RegulatoryListing..............................11
2.3GeneralGuidelines.............................12
2.4RadioFrequencyInterference......................16
2.5TravelingwiththeXPO
2
.........................17
3Accessories.....................................20
3.1OptionalAccessories............................20
4Setup..........................................21
4.1Unpacking....................................21
4.2Inspection....................................21
4.3Location.....................................21
5Usage..........................................22
5.1GettingStarted................................22
5.2Connecting/PositioningtheNasalCannula.............22
5.3UsingtheXPO
2
PortableConcentrator..............23
5.4AdjustingthePulseFlowSetting....................24
5.5CheckingChargeLevelofInternalBattery.............25
5.6ChargingtheInternalBattery......................25
5.7ChargingtheSupplementalBattery..................26
5.8ChargingtheInternalandSupplementalBatteryPack
Simultaneously...............................27
5.9BatteryLifeandManagement......................28
6Maintenance....................................29
6.1CleaningtheCabinet............................29
6.2CleaningtheAirIntakeFilter......................29
6.3CleaningtheCarryingBag........................30
6.4MaintenanceChecklist...........................31
7AfterUse.......................................32
7.1Storage......................................32
7.2Disposal.....................................32
8Troubleshooting.................................33
8.1Troubleshooting...............................33
9Warranty.......................................38
9.1NorthAmericanLimitedWarranty..................38
Invacare®XPO
1General
1.1Symbols
Signalwordsareusedinthismanualandapplytohazardsorunsafe
practiceswhichcouldresultinpersonalinjuryorpropertydamage.
Refertothefollowingtablefordefinitionsofthesignalwords.
DANGER!Dangerindicatesanimminentlyhazardous
situationwhich,ifnotavoided,willresultindeathor
seriousinjury.
WARNING!Warningindicatesapotentially
hazardoussituationwhich,ifnotavoided,could
resultindeathorseriousinjury.
CAUTION!Cautionindicatesapotentially
hazardoussituationwhich,ifnotavoided,mayresult
inpropertydamageorminorinjuryorboth.
Givesusefultips,recommendationsandinformation
forefficient,trouble-freeuse.
IMPORTANTindicatesahazardoussituationthat
couldresultindamagetopropertyifitisnotavoided.
ThisproductcomplieswithDirective93/42/EEC
concerningmedicaldevices.
ThelaunchdateofthisproductisstatedintheCE
declarationofconformity.
Consulttheusermanual.
DirectCurrent
TypeBFequipment
DONOTsmoke
ClassIIequipment
PowerOn/Off
DONOTdisposeofinhouseholdwaste
Recycle
DONOTuseoilorgrease
Keepdry
Protectedagainstdrippingwater
Restrictedtosalebyoronorderofamedical
professional
4
1148112-F~12
General
1.2IntendedUse
TheInvacareportableoxygenconcentratoristobeusedbypatients
withrespiratorydisorderswhorequiresupplementaloxygen.The
deviceisnotintendedtosustainorsupportlife.
DANGER!
RISKOFINJURYORDEATH
Thisproductistobeusedasanoxygensupplementand
isnotintendedtobelife-supportingorlife-sustaining.
ONLYusethisproductifthepatientiscapableof
spontaneousbreath,abletoinhaleandexhalewithout
theuseofamachine.
DONOTuseinparallelorserieswithotheroxygen
concentratorsoroxygentherapydevices.
WARNING!
RISKOFINJURYORDAMAGE
Useofthisproductoutsideoftheintendeduseand
productparametershasnotbeentestedandmayleadto
productdamage,lossofproductfunction,orpersonal
injury.
DONOTusethisproductinanywayotherthan
describedintheproductparametersandintendeduse
sectionsofthismanual.
1.2.1Description
Theoxygenconcentrationleveloftheoutputgasrangesfrom87%
to95.6%.Theoxygenisdeliveredtothepatientthroughtheuse
ofanasalcannula.Whenthedemandforoxygenisdetected,the
oxygenisdeliveredthroughpulsedflowwithpulseflowsettingsof1
through5.
TheInvacareportableconcentratoriscapableofoperationbythe
patientinahomeenvironment,inaninstitutionalenvironmentor
inavehicleorothermobileenvironment.Devicestandardpower
optionsincludeanACtoDCswitchingpowersupplyoperatingfrom
ACpoweroutlet(120VAC/60Hertzor230VAC/50Hertznominal),
aDCtoDCswitchingpowersupplyoperatingfromaccessory
outletstypicallyfoundinamobilevehicletypeenvironment(12VDC
nominal)andasupplementalrechargeablebattery.
1148112-F~125
Invacare®XPO
1.3Features
1.3.1UserInterface
A
On/offbutton
DecreaseB
IncreaseC
FlowSelectionbuttons
TheXPO
2
concentratorcan
beadjustedtoyourprescribed
flowsettingbypressingtheflow
selection(+or–).Theselected
flowsettingisilluminatedbya
blueindicatorlight.
D
BatteryStatusbutton
Pressoncetodeterminethe
chargeleveloftheinternal
battery.
E
AlarmIndicator
Indicatesabnormalconditions
andwarnstheuser.Referto
8.1Troubleshooting,page33
formoredetails.
F
BatteryGaugeDisplay
Indicatesthelevelofbattery
chargeremaining.
61148112-F~12
General
1.3.2Indicators,Warnings,andAlarms
Start-UpIndicator TheXPO
2
concentratorwillturnonalllightsbrieflyandcheckforstuckbuttonsuponpowerup.Itwill
thenoutputabriefaudiblebeepwhenfirstturnedontoindicatetheunitisoperational.
BreathDetectIndicator
TheXPO
2
concentratorwilldeliverameasuredpulseofoxygeneachtimeitdetectsaninhalation.The
blueflowsettingindicatorlightwillblinkeachtimeaninhalationisdetectedandtheXPO
2
concentrator
outputsapulseofoxygen.
InternalBatteryChargingIndicator Whentheconcentratorisnotturnedon,buttheAC,orDC,chargerisconnectedtotheconcentrator
andprovidingpower,theBatteryGaugeDisplaywillsequentiallyilluminateeachofthefoursegments.
Periodicallythesequentialilluminationwillbeinterruptedbytheactualbatterychargedisplay.
Iftheconcentratorisfullycharged,allfoursegmentswillbeilluminatedcontinuouslyuntilthe
concentratoristurnedon,orremovedfromchargerpower.IfnoBatteryGaugeDisplaysegments
areilluminated,theconcentratorisnotcharging.Thelackofchargingcouldbeduetoeitheralossof
power,loosechargerconnectionsortheinternalbatteryisnotatthepropertemperatureforcharging.
Allowtheunittowarm,orcool,torecommendedchargingtemperaturerange(see2.1TypicalProduct
Parameters,page9),checkforlooseconnectionsand/ortryadifferentpoweroutlet.
AudibleAlarms Totemporarilysilencetheaudiblealarms,quicklypresstheOn/Offbutton.ExceptforthesystemToo
Hot/TooColdalarms,thisfeaturewillresetitself,every30seconds,eachtimeanewalarmistriggered,
oriftheunitisturnedOff.WhenperformedduringthesystemTooHot/TooColdalarms,theaudible
alarmwillbesilenceduntilanewalarmistriggered,ortheconcentratoristurnedOff.
Forallalarmsandwarnings,referto8.1Troubleshooting,
page33.
1.3.3Filters
AirenterstheXPO
2
concentratorthroughanairintakefilterlocated
underthecoveronthefrontoftheunit.Thisfilterpreventshairand
otherlargeparticlesintheairfromenteringtheunit.Beforeyou
operatetheXPO
2
concentrator,makesurethisfilterisclean,dry
andproperlypositioned.
Toclean/replacetheairintakefilter,referto6.2CleaningtheAir
IntakeFilter,page29.
1148112-F~127
Invacare®XPO
1.3.4PowerSupplies
WARNING!
RiskofInjuryorDamage
Toavoidinjuryordamagewhichwillvoidwarranty:
UseonlyInvacarespecifiedpowersupplies.
TheXPO
2
concentratorcanbesuppliedpowerfromafactory
installedinternalbattery,fromanACpoweradapterconnectedto
thewalloutlet,fromaDCpoweradapterconnectedtoaDCoutlet
likethatfoundinanautomobile,orfromasupplementalbatterypack.
InternalBattery:Arechargeable,internalbatteryislocatedinside
theXPO
2
concentrator.Whenfullycharged,itsuppliespowerfor
upto3.5hours.Anaudiblealarmsoundswhenthebatterypoweris
gettinglow.Referto1.3.2Indicators,Warnings,andAlarms,page7.
ACPowerAdapter:AnACpoweradapterallowstheXPO
2
concentratortobeconnectedtoa100-230volt50/60hertzoutlet.
UseoftheACpoweradapterwillallowtheXPO
2
concentratorto
beoperatedandsimultaneouslyrechargetheinternalbattery.This
ACpoweradaptercanalsobeusedtorechargethesupplemental
batterypack.Referto5.6ChargingtheInternalBattery,page25,5.7
ChargingtheSupplementalBattery,page26and5.8Chargingthe
InternalandSupplementalBatteryPackSimultaneously,page27.
DCPowerAdapter:ADCpoweradapterallowstheXPO
2
concentratortobeconnectedtoanautomobile’s(boat,motorhome,
etc.…)12-voltDCoutlet.UseoftheDCpoweradapterwillallow
theXPO
2
concentratortobeoperatedandsimultaneouslyrecharge
theinternalbattery.ThisDCpoweradaptercanalsobeusedto
rechargethesupplementalbatterypack.Referto5.6Chargingthe
InternalBattery,page25,5.7ChargingtheSupplementalBattery,
page26and5.8ChargingtheInternalandSupplementalBatteryPack
Simultaneously,page27.
SupplementalBatteryPack:TheXPO
2
concentratorcanbe
poweredbyasupplementalbatterypackC.Thisbatterypackcanbe
attachedtotheXPO
2
carryingbagandconnectedtothepowerinput
connectoroftheunit.Thesupplementalbatterypackwillprovideup
to3.5hoursofadditionalruntime.Thesupplementalbatterypack
hasitsownbatterystatusbuttonBandbatterygaugeAtoidentify
thelevelofbatterycharge.
Thesupplementalbatterycannotbeusedtochargethe
internalbattery.
81148112-F~12
Safety
2Safety
2.1TypicalProductParameters
ElectricalRequirements:
ACPowerSupply:120VAC60Hzand230VAC50Hz
DCPowerSupply:11VDC,6.5A
RatedCurrentInput:3.8Aat18VDC
SoundLevelatsetting2:< 42.7dBAweighted
Altitude:Upto10,000ft(3046m)abovesealevel
OxygenConcentration:*
*Basedonanatmosphericpressureof14.7psi(101kPa)at70°F(21°C)
87%to95.6%,afterinitialwarm-upperiod(approximately5minutes)
ConserverTriggerSensitivity:
Factorysetnoadjustment
Pressureactivated
< 0.20cmH
2
Opressuredrop
Allsettingsusing7ft(2.1m)cannula
ConserverTriggerDelay:
Factorysetnoadjustment
50mSec
Nominalvalueusing7ft(2.1m)cannula
ConserverBreathRateCapacity:Upto,andincluding,35BPMwithoutreductionofbolusminutevolume
ConserverBolusDelivery:
Fixedminutevolume
Setting1:300cc
Setting2:460cc
Setting3:620cc
Setting4:740cc
Setting5:840cc
Dimensions:
10”highx7”widex4”deep(25.4cmhighx17.8cmwidex10.2
cmwide)
1148112-F~129
Invacare®XPO
Weight:6.40lbs(2.90kg);1.20lbs(0.54kg)forsupplementalbattery
BatteryDuration:
Setting1=3:40hrs
*Timesareapproximate(Hr:Min)
Setting2=2:40hrs
Setting3=2:00hrs
Setting4=1:40hrs
Setting5=1:20hrs
BatteryRechargeTime:
Rechargetimeincreasesifbatteryischargingwhileunitis
running.
4hours
Humidity
OperatingHumidity:15%to60%noncondensing
StorageHumidity:upto95%noncondensing
TemperatureRange:
(Allpowersources)
Operatingtemperature:41°Fto95°F(5°Cto35°C)
Storagetemperature:-2°Fto140°F(-20°Cto60°C)
ExtendedTemperatureRange:
(UsingACorDCadapters)
OperatingTemperature:
95°Fto104°(35°Cto40°C)
Continuoususe-allsettings
101148112-F~12
Safety
ExtendedTemperatureRange
(UsingInternalBattery)
*Timesareapproximate(Hr:Min)
OperatingTemperature:
95°Fto104°F(35°Cto40°C)
Settings1=3:40hrs
Setting2=2:40hrs
Setting3=2:00hrs
Setting4=1:45hr
Setting5=1:10hr
2.2RegulatoryListing
ETLcertifiedcomplyingwith:EN55011:2009
CISPR11:2009
IEC60601-1;2nded.
IEC60601-1-2;3rded.2007
IEC61000-3-2:2006
IEC61000-3-3:2008
UL60601-1,1sted.
CSA601.1M90
EN60601-1-2:2007
EN61000-3-2:2006
EN61000-3-3:2008
93/42/EECClassIIa
CENELECEN60601–1:1990
1148112-F~12
11
Invacare®XPO
2.3GeneralGuidelines
Inordertoensurethesafeinstallation,assemblyandoperationofthe
XPO
2
concentratortheseinstructionsMUSTbefollowed.
DANGER!
RiskOfDeath,Injury,OrDamage
Improperuseoftheproductmaycausedeath,injuryor
damage.Thissectioncontainsimportantinformationfor
thesafeoperationanduseofthisproduct.
DONOTusethisproductoranyavailableoptional
equipmentwithoutfirstcompletelyreadingand
understandingtheseinstructionsandanyadditional
instructionalmaterialsuchasusermanuals,service
manualsorinstructionsheetssuppliedwiththis
productoroptionalequipment.
Ifyouareunabletounderstandthewarnings,cautions
orinstructions,contactahealthcareprofessional,
dealerortechnicalpersonnelbeforeattemptingto
usethisequipment.
CheckALLexternalcomponentsandcartonfor
damage.Incaseofdamage,oriftheproductisnot
workingcorrectly,contactatechnicianorInvacare
forrepair.
THEINFORMATIONINTHISDOCUMENTIS
SUBJECTTOCHANGEWITHOUTNOTICE.
DANGER!
RiskOfDeath,Injury,OrDamageFromFire
Textiles,oilorpetroleumsubstances,grease,greasy
substancesandothercombustiblesareeasilyignited
andburnwithgreatintensityinoxygenenrichedairand
whenincontactwithoxygenunderpressure.Toavoid
fire,death,injuryordamage:
DONOTSMOKEwhileusingthisdevice.
DONOTusenearOPENFLAMEorIGNITION
SOURCES.
DONOTuseanylubricantsonconcentratorunless
recommendedbyInvacare.
NOSMOKINGsignsshouldbeprominentlydisplayed.
Avoidcreationofanysparknearoxygenequipment.
Thisincludessparksfromstaticelectricitycreatedby
anytypeoffriction.
Keepallmatches,lightedcigarettesorothersources
ofignitionoutoftheroominwhichthisconcentrator
islocatedandawayfromwhereoxygenisbeing
delivered.
Keeptheoxygentubing,cord,andconcentratorout
fromundersuchitemsasblankets,bedcoverings,
chaircushions,clothing,andawayfromheatedorhot
surfacesincludingspaceheaters,stoves,andsimilar
electricalappliances.
12
1148112-F~12
Safety
DANGER!
RiskofDeath,Injury,fromElectricShock
Toreducetheriskofburns,electrocution,deathor
injurytopersons:
DONOTdisassemble.Referservicingtoqualified
servicepersonnel.Therearenouserserviceable
parts.
Avoidusingwhilebathing.Ifcontinuoususage
isrequiredbythephysician'sprescription,the
concentratormustbelocatedinanotherroomat
least7ft(2.5m)fromthebath.
DONOTcomeincontactwiththeconcentrator
whilewet.
DONOTplaceorstoreconcentratorwhereitcan
dropintowaterorotherliquid.
DONOTreachforconcentratorthathasfalleninto
water.UnplugIMMEDIATELY.
DONOTusefrayedordamagedACadaptercords.
WARNING!
RiskOfInjuryOrDamage
Invacareproductsarespecificallydesignedand
manufacturedforuseinconjunctionwithInvacare
accessories.Accessoriesdesignedbyother
manufacturershavenotbeentestedbyInvacareand
arenotrecommendedforusewithInvacareproducts.
CAUTION!
Federal(statutory)lawrestrictsthisdevicetosaleby
orontheorderofamedicalpractitionerlicensedbya
governmentalagencywherehe/shepractices.
ONLYalicensedmedicalpractitionermayorderthe
purchaseoruseofthisdevice.
DANGER!
RiskofInjuryorDeath
Toavoidchokingoringestionofchemicalsfromairway
contamination:
DONOTusetheconcentratorinthepresenceof
pollutants,smoke,fumes,flammableanesthetics,
cleaningagents,orchemicalvapors.
WARNING!
RiskofInjuryorDeath
Topreventinjuryordeathfromproductmisuse:
Closelysupervisewhenthisconcentratorisusedby
ornearchildrenorphysically-challengedindividuals.
Monitorpatientsusingthisdevicewhoareunableto
hearorseealarmsorcommunicatediscomfort.
WARNING!
RiskofInjuryorDeath
Toreducetheriskofinjuryordeathfromillness:
Replacethenasalcannulaonaregularbasis.Check
withyourequipmentproviderorphysicianto
determinehowoftenthecannulashouldbereplaced.
DONOTsharecannulasbetweenpatients.
1148112-F~1213
Invacare®XPO
WARNING!
RiskofInjury
Itisimportanttoplanaheadfortravelandother
situationsinwhichyoumaynothaveaccesstoadditional
oxygenorpowersupplies.Topreventinjuryfrom
oxygendeprivation:
Carrysupplementalbatterieswithyou.
Stowtheconcentratorproperlyduringtravel.For
properstorageinstructionswhentravellingreferto
thetravelguide.
Obtainandcarryalicensedphysician’ssigned
statementonastandardform(p/n1154266),the
doctor’sletterhead,oranairline-approvedform
duringtravel.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamagefromcordmisuse:
DONOTmoveorrelocateconcentratorbypulling
onthecord.
DONOTuseextensioncordswithACpower
adaptersprovided.
Properlystoreandpositionelectricalcordsand/or
tubingtopreventatrippinghazard.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamagefrommisuse:
NEVERleaveconcentratorunattendedwhenplugged
in.
Makesureconcentratorisoffwhennotinuse.
OutdooruseMUSTbeconductedwithinternalor
supplementalbatterypoweronly.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamageduringuse:
Ifyoufeelilloruncomfortable,oriftheconcentrator
doesnotsignalanoxygenpulseandyouareunable
tohearand/orfeeltheoxygenpulse,consult
yourequipmentproviderand/oryourphysician
IMMEDIATELY.
Foroptimumperformance,Invacarerecommendsthat
eachconcentratorbeonandrunningforaminimum
of30minutes.Shorterperiodsofoperationmay
reducemaximumproductlife.
Formaximumoxygenoutput,theconcentratorshould
beusedinanuprightposition.
TheXPO
2
concentratorcannotbeusedinconjunction
withPAP,Bi-Level,mechanicalventilatororother
suchdevices.
14
1148112-F~12
Safety
WARNING!
RiskofInjury
Achangeinaltitudemayaffecttotaloxygenavailableto
you.Topreventoxygendeprivation:
Consultyourphysicianbeforetravelingtohigheror
loweraltitudestodetermineifyourflowsettings
shouldbechanged.
WARNING!
RiskofInjuryorDamage
Asasafetyfeature,thisappliancemayhaveapolarized
plug(onebladeiswiderthantheother).Toavoidinjury
ordamagefromelectricalshock:
Thisplugwillfitinapolarizedoutletonlyoneway.
Iftheplugdoesnotfitfullyintheoutlet,reverse
theplug.Ifitstilldoesnotfit,contactaqualified
electrician.
DONOTalterthepluginanyway.
DONOTuseifthecordorplugaredamaged.Calla
qualifiedelectricianforrepair.
WARNING!
RiskofInjuryorDamage
Invacareoxygenconcentratorsarespecificallydesigned
tominimizeroutinepreventivemaintenance.Toprevent
injuryordamage:
Onlyprofessionalsofthehealthcarefieldor
personsfullyconversantwiththisprocesssuchas
factorytrainedpersonnelshouldperformpreventive
maintenanceorperformanceadjustmentsonthe
oxygenconcentrator,exceptfortasksdescribedin
thismanual.
UsersshouldcontactyourdealerorInvacarefor
service.
CAUTION!
RiskofMinorInjuryorDiscomfort
Duringtheinitialstartuptime(app.30minutes)oxygen
outputisnotwithinspecificationslistedinTypical
ProductParameters.
Concentratormaybeusedduringstartuptime.
1148112-F~1215
Invacare®XPO
CAUTION!
RiskofDamage
Topreventdamagefromliquidingress:
IftheXPO
2
concentratorisnotworkingproperly,
ifithasbeendroppedordamaged,ordroppedinto
water,callequipmentprovider/qualifiedtechnicianfor
examinationandrepair.
NEVERdroporinsertanyobjectorliquidintoany
opening.
InvacarerecommendstheXPO
2
concentratornotbe
usedintherain.
TheXPO
2
concentratorisnotdesignedtobe
usedwithahumidifier.Useofthisdevicewitha
humidifiermayimpairperformanceand/ordamage
theequipment.
CAUTION!
RiskofDamage
Topreventdamagefromtemperaturevariations:
DONOToperateintemperaturesbelow41°F(5°C)
orabove104°F(40°C)forextendedperiodsoftime.
WhenyourautomobileisturnedOff,disconnectthe
caraccessorypowersupplyandremovetheXPO
2
concentratorfromtheautomobile.NEVERallow
theXPO
2
concentratortobestoredinaveryhot
orcoldautomobileorinothersimilar,highorlow,
temperatureenvironments.Referto2.1Typical
ProductParameters,page9.
2.4RadioFrequencyInterference
ThisequipmenthasbeentestedandfoundtocomplywithEMClimits
specifiedbyIEC/EN60601-1-2.Theselimitsaredesignedtoprovide
areasonableprotectionagainstelectromagneticinterferenceina
typicalmedicalinstallation.
Otherdevicesmayexperienceinterferencefromeventhelowlevels
ofelectromagneticemissionspermittedbytheabovestandards.To
determineiftheemissionsfromtheXPO
2
concentratorarecausing
theinterference,turntheXPO
2
concentratorOff.Iftheinterference
withtheotherdevice(s)stops,thentheXPO
2
concentratoriscausing
theinterference.Insuchrarecases,interferencemaybereducedor
correctedbyoneofthefollowingmeasures:
Reposition,relocate,orincreasetheseparationbetweenthe
equipment.
Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichtheotherdevice(s)isconnected.
DONOTconnecttheconcentratorinparallelorserieswithother
oxygenconcentratorsoroxygentherapydevices.
161148112-F~12
Safety
2.5TravelingwiththeXPO
2
BeforeTraveling
1.Contactyourtravelcarrierand/ortourguideaboutyourtravel
plansandprovideinformationaboutyourintenttouseaportable
oxygenconcentrator(POC)duringyourtravels.Thecarrier
willletyouknowifyouwillbepermittedtouseyourXPO
2
concentratorduringyourtravelandifthereareanyrestrictions
foruse.
IfyouarenotpermittedtouseyourXPO
2
concentrator
ontheairlineofchoiceandstillwanttotakeitwithyou:
Carryitandanysupplementalbatteriesonboard
withyou.
Ensuretheunitisturnedoff.
Stowitproperlyfortheflight.
DONOTplacetheXPO
2
concentratororany
supplementalbatterymodulesincheckedbaggage.
2.Contacttheairlinetoseeiftheyhaveseatswithapoweroutlet
thatyoucanusetopowertheXPO
2
concentratorduringthe
flight.Ifapoweroutletisnotavailable,besuretobringenough
supplementalbatteriestolast150%oftheflighttime.
Theremaybeunexpecteddelaysbeyondscheduled
flighttimes.Carryyourpoweradapterswithyousoyou
canrechargebatteriesbeforeandaftertheflight.
3.Ensureyouhavealicensedphysician’ssignedstatementona
standardform(p/n1154266),thedoctor’sletterheadoran
airline-approvedformthatcontainsthefollowinginformation:
Yourneedforoxygenduringtaxi,takeoff,flighttimes,
landing,ortheentiretimeyouaretraveling.
Theflowrate(s)thatyouwilluseduringyourtrip.
Yourunderstanding,orthatofyourtravelcompanion,
ofallthecautions,warnings,andalarmsoftheXPO
2
concentratorandwhattodoifthereisanalarmsituation
withthedevice.
Yourpersonalinformationsuchasname,dateofbirth,and
themodelnameornumberoftheportableconcentrator.
YouMUSThavethisformwithyouatalltimes
duringyourtravel.
4.ChargetheinternalbatteryoftheXPO
2
concentratorandany
supplementalbatteriesfullybeforeyoudepart,thusextending
theoperatingtimeoftheXPO
2
concentratorduringtravel.
RefertoRechargingtheBatteryintheowner’smanual.
5.Ensuretheunitisfreeofallgrease,oil,orotherpetroleum
productsandthattheunitisingoodworkingorder,isfreeof
damage,andtheairfilterisclean.RefertoMaintenanceinthe
owner’smanual.
6.Contactyouroxygensuppliertomakearrangementsifyouneed
tohavebackupoxygenatyourdestination.
1148112-F~1217
Invacare®XPO
ArrivingattheAirport
1.AllowthesecurityagenttoinspectyourXPO
2
concentrator,
evenifyouareusingit,whengoingthroughthesecurity
checkpoint.
Theyarerequiredtoallowyoutotravelthroughthe
checkpointwithyourPOC,buttheyMUSTinspectit
forsecurityreasons.
2.UseyourACpoweradapterwhileyouareintheairport,if
possible.Thiswillkeepthebatteriesatfullchargeandgiveyou
themostbatterypoweredoperatingtimeontheaircraft.
BoardingthePlane
Youarenotpermittedtositinanexitrowifyouplantouse
yourXPO
2
concentratoratanytimeduringtheflight.
1.IfyouplanonusingtheXPO
2
concentratortheentiretime
youaretheplane,verifythatyourXPO
2
concentratordoes
notblockaccesstoanemergencyexitoraisleway.Ifitdoes,
requestaseatchange.
2.Showthepilotorflightcrewyoursignedphysician’sstatement
regardingyouruseoftheXPO
2
concentrator,ifasked.
3.Inorderfortheflightcrewtoensurethesafetyofyouandall
oftheotherpassengersontheflight,allowthemtoinspect
theXPO
2
concentratortoconfirmthatitisFAAapprovedfor
useontheflight.
4.IfyouarenotplanningtouseyourXPO
2
concentratorduring
taxi,takeoff,orlanding,youMUSTstoreitinanapproved
storageareasoitdoesnotblocktheroworaisleaccess.
Contacttheflightcrewaboutlocationofapproved
storageareas.
OnthePlane
YouMUSTstorethesupplementalbatteryeithersecurely
connectedtotheXPO
2
concentratororinyourcarry-on
baggage.ThesupplementalbatteryMUSTbeprotectedfrom
damageandshortingouttheexternalpowerconnector.
1.YoumayuseyourXPO
2
concentratorwhenmovingaboutthe
cabin,ONLYafterthepilotturnsoffthe“FastenSeatBelt”sign.
2.TurnofftheunitiftheXPO
2
concentratoralarmsduringthe
flight,unlessthealarmresetsitself.Ifthealarmdoesnotreset,
theXPO
2
concentratorMUSTbeturnedoffandstoredinan
approvedstoragearea.
3.IfanACpoweroutletisavailableontheflight,performthe
following:
a.ConnectthepoweradaptertotheXPO
2
concentrator.
b.Pluginthepoweradapterintotheairlinepoweroutlet.
c.Turntheuniton.
Ifyouhaveanytroublemakingtheconnectionstotheplane’s
poweroutlet,contacttheflightcrewforassistance.
AftertheFlight
1.EnsureyouhaveenoughpowertorunyourXPO
2
concentrator
whileleavingtheairport.Rechargethebatteries,ifnecessary.
RefertoRechargingtheBatteryintheowner’smanual.
2.Contactyourmedicalgassuppliertoobtainyourbackupoxygen
supply,ifnecessary.
TravelingbyBoat
Contactthecruiselineandinformthemyouaretravelingwitha
POC.ThereshouldbenorestrictionsonyouruseoftheXPO
2
concentratorduringyourtravelbutitiswisetocheckwiththem
181148112-F~12
Safety
aheadoftime.PowershouldbeavailableforuseofyourACpower
adapterduringyourtravels,butcheckfirst.
TravelingbyTrain
Contactthetrainauthoritiesatleasttwelvehoursaheadofarrival
thatyouaregoingtouseyourPOC.Thereshouldbenorestrictions
onyouruseoftheXPO
2
concentrator,butpoweronthetrainmay
notbeavailableforyouruseduringtraveltimes.Ensurethereis
enoughbatterylifeforyourtripbeforeyouleave.
TravelingbyBus
ContactthebuslineaboutusingaPOC.Thereshouldbeno
restrictionsonyouruseoftheXPO
2
concentratorduringyourtrip,
butpowermaynotbeavailableforyouruseduringtraveltimes.
Ensurethereisenoughbatterylifeforyourtripbeforeyouleave.
1148112-F~1219
Invacare®XPO
3Accessories
3.1OptionalAccessories
Thefollowingoptionalaccessoriesandreplacementparts(listed
below)arealsoavailable:
Supplementalbattery(providesuptoadditional2.40(Hr:Min)
onSetting2ofextendedbatterylife),modelnumberXPO110
CarryingBag,modelnumberXPO150
Wheeledcartwithhandle,modelnumberXPO120
Airintakefilter,partnumber1157692
DCpoweradapter,modelnumberXPO140
Accessorybag,modelnumberXPO160(UnitmodelXPO100B
only)
ACpoweradapter,powercordstyle:
NorthAmerica,JapanmodelnumberXPO130
EuropemodelnumberXPO132
Australia,NewZealandmodelnumberXPO134
UnitedKingdom,HongKong,Vietnammodelnumber
XPO136
201148112-F~12
/